메뉴 건너뛰기




Volumn 363, Issue 4, 2010, Pages 311-320

Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes

(12)  Bergenstal, Richard M a   Tamborlane, William V b   Ahmann, Andrew c   Buse, John B d   Dailey, George e   Davis, Stephen N g   Joyce, Carol h   Peoples, Tim f   Perkins, Bruce A i   Welsh, John B f   Willi, Steven M j   Wood, Michael A k  


Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE; GLYCOSYLATED HEMOGLOBIN; INSULIN ASPART; INSULIN GLARGINE;

EID: 77954830051     PISSN: 00284793     EISSN: 15334406     Source Type: Journal    
DOI: 10.1056/NEJMoa1002853     Document Type: Article
Times cited : (781)

References (13)
  • 1
    • 0027998781 scopus 로고
    • Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications Trial
    • Diabetes Control and Complications Trial Research Group
    • Diabetes Control and Complications Trial Research Group. Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications Trial. J Pediatr 1994;125:177-88.
    • (1994) J Pediatr , vol.125 , pp. 177-188
  • 2
    • 67749084303 scopus 로고    scopus 로고
    • Modern-day clinical course of type 1 diabetes mellitus after 30 years' duration: The Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications and Pittsburgh Epidemiology of Diabetes Complications experience (1983-2005)
    • Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Research Group
    • Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Research Group. Modern-day clinical course of type 1 diabetes mellitus after 30 years' duration: the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications and Pittsburgh Epidemiology of Diabetes Complications experience (1983-2005). Arch Intern Med 2009;169:1307-16.
    • (2009) Arch Intern Med , vol.169 , pp. 1307-1316
  • 3
    • 29144453326 scopus 로고    scopus 로고
    • Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
    • Idem
    • Idem. Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes. N Engl J Med 2005;353:2643-53.
    • (2005) N Engl J Med , vol.353 , pp. 2643-2653
  • 4
    • 77950902799 scopus 로고    scopus 로고
    • Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus
    • CD005103
    • Misso ML, Egberts KJ, Page M, O'Connor D, Shaw J. Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus. Cochrane Database Syst Rev 2010;1:CD005103.
    • (2010) Cochrane Database Syst Rev , vol.1
    • Misso, M.L.1    Egberts, K.J.2    Page, M.3    O'Connor, D.4    Shaw, J.5
  • 5
    • 77949272947 scopus 로고    scopus 로고
    • Sensor augmented pump therapy substantially lowers HbA1c: A randomized controlled trial
    • abstract
    • Hermanides J, Nørgaard K, Bruttomesso D, et al. Sensor augmented pump therapy substantially lowers HbA1c: a randomized controlled trial. Diabetologia 2009;52:Suppl 1:S43. abstract.
    • (2009) Diabetologia , vol.52 , Issue.SUPPL. 1
    • Hermanides, J.1    Nørgaard, K.2    Bruttomesso, D.3
  • 6
    • 50049127632 scopus 로고    scopus 로고
    • Sensor-augmented insulin pump therapy: Results of the first randomized treat-to-target study
    • Hirsch IB, Abelseth J, Bode BW, et al. Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Ther 2008;10:377-83.
    • (2008) Diabetes Technol Ther , vol.10 , pp. 377-383
    • Hirsch, I.B.1    Abelseth, J.2    Bode, B.W.3
  • 7
    • 72249116711 scopus 로고    scopus 로고
    • Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: The RealTrend study
    • Raccah D, Sulmont V, Reznik Y, et al. Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: the RealTrend study. Diabetes Care 2009;32:2245-50.
    • (2009) Diabetes Care , vol.32 , pp. 2245-2250
    • Raccah, D.1    Sulmont, V.2    Reznik, Y.3
  • 8
    • 54849147700 scopus 로고    scopus 로고
    • Continuous glucose monitoring and intensive treatment of type 1 diabetes
    • The Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group
    • The Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 2008;359:1464-76.
    • (2008) N Engl J Med , vol.359 , pp. 1464-1476
  • 9
    • 77949383313 scopus 로고    scopus 로고
    • STAR 3 randomized controlled trial to compare sensor-augmented insulin pump therapy with multiple daily injections in the treatment of type 1 diabetes: Research design, methods, and baseline characteristics of enrolled subjects
    • Davis SN, Horton ES, Battelino T, Rubin RR, Schulman KA, Tamborlane WV. STAR 3 randomized controlled trial to compare sensor-augmented insulin pump therapy with multiple daily injections in the treatment of type 1 diabetes: research design, methods, and baseline characteristics of enrolled subjects. Diabetes Technol Ther 2010;12:249-55.
    • (2010) Diabetes Technol Ther , vol.12 , pp. 249-255
    • Davis, S.N.1    Horton, E.S.2    Battelino, T.3    Rubin, R.R.4    Schulman, K.A.5    Tamborlane, W.V.6
  • 10
    • 78651338445 scopus 로고    scopus 로고
    • Standards of medical care in diabetes - 2010
    • American Diabetes Association
    • American Diabetes Association. Standards of medical care in diabetes - 2010. Diabetes Care 2010;33:Suppl 1:S11-S61.
    • Diabetes Care 2010 , vol.33 , Issue.SUPPL. 1
  • 11
    • 70449378190 scopus 로고    scopus 로고
    • Factors predictive of use and of benefit from continuous glucose monitoring in type 1 diabetes
    • Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group
    • Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. Factors predictive of use and of benefit from continuous glucose monitoring in type 1 diabetes. Diabetes Care 2009;32:1947-53.
    • (2009) Diabetes Care , vol.32 , pp. 1947-1953
  • 12
    • 49649112407 scopus 로고    scopus 로고
    • Severe hypoglycaemia and glycaemic control in Type 1 diabetes: Meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion
    • Pickup JC, Sutton AJ. Severe hypoglycaemia and glycaemic control in Type 1 diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion. Diabet Med 2008;25:765-74.
    • (2008) Diabet Med , vol.25 , pp. 765-774
    • Pickup, J.C.1    Sutton, A.J.2
  • 13
    • 11844250564 scopus 로고    scopus 로고
    • Insulin analogues
    • Hirsch IB. Insulin analogues. N Engl J Med 2005;352:174-83.
    • (2005) N Engl J Med , vol.352 , pp. 174-183
    • Hirsch, I.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.