메뉴 건너뛰기




Volumn 76, Issue , 2012, Pages 129-139

Model-integrated process development demonstrated on the optimization of a robotic cation exchange step

Author keywords

Chromatography; Downstream processing; Mathematical modeling; Optimization; Scale up; Simulation

Indexed keywords

CATION EXCHANGES; CYTOCHROME C; DESIGNED EXPERIMENTS; DOWNSTREAM-PROCESSING; ELUTION GRADIENT; HIGH PRECISION; HIGH-THROUGHPUT SCREENING; MATHEMATICAL MODELING; MECHANISTIC MODELING; MULTI-COMPONENT SEPARATION; OPTIMAL SETTING; PEAK RESOLUTION; PERFORMANCE VARIABLES; PH CONDITION; PROCESS DEVELOPMENT; RETENTION TIME; RIBONUCLEASE A; ROBUSTNESS ANALYSIS; SCALE-UP; SIMULATION;

EID: 84860534665     PISSN: 00092509     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ces.2012.04.004     Document Type: Article
Times cited : (46)

References (45)
  • 1
    • 84860422179 scopus 로고    scopus 로고
    • Omics tools in accelerated purification process development: multidimensional fractionation and characterization of crude protein mixtures
    • Ahamed T., Nfor B., van der Wielen L., Verhaert P., van Dedem G., Eppink M., van de Sandt E., Ottens M. Omics tools in accelerated purification process development: multidimensional fractionation and characterization of crude protein mixtures. J. Biosci. Bioeng. 2009, 108(1):S58.
    • (2009) J. Biosci. Bioeng. , vol.108 , Issue.1
    • Ahamed, T.1    Nfor, B.2    van der Wielen, L.3    Verhaert, P.4    van Dedem, G.5    Eppink, M.6    van de Sandt, E.7    Ottens, M.8
  • 2
    • 0142171804 scopus 로고    scopus 로고
    • Parameter estimation for the simulation of liquid chromatography
    • Altenhoener U., Meurer M., Strube J., Schmidt-Traub H. Parameter estimation for the simulation of liquid chromatography. J. Chromatogr. A 1997, 769(1):59-69.
    • (1997) J. Chromatogr. A , vol.769 , Issue.1 , pp. 59-69
    • Altenhoener, U.1    Meurer, M.2    Strube, J.3    Schmidt-Traub, H.4
  • 4
    • 70449393573 scopus 로고    scopus 로고
    • Rational and systematic protein purification process development: the next generation
    • Beckley K., Verhaert P., van der Wielen L., Hubbuch J., Ottens M. Rational and systematic protein purification process development: the next generation. Trends Biotechnol. 2009, 27(12):673-679.
    • (2009) Trends Biotechnol. , vol.27 , Issue.12 , pp. 673-679
    • Beckley, K.1    Verhaert, P.2    van der Wielen, L.3    Hubbuch, J.4    Ottens, M.5
  • 5
    • 28244461283 scopus 로고    scopus 로고
    • High throughput screening of chromatographic phases for rapid process development
    • Bensch M., Schulze Wierling P., von Lieres E., Hubbuch J. High throughput screening of chromatographic phases for rapid process development. Chem. Eng. Technol. 2005, 28(11):1274-1284.
    • (2005) Chem. Eng. Technol. , vol.28 , Issue.11 , pp. 1274-1284
    • Bensch, M.1    Schulze Wierling, P.2    von Lieres, E.3    Hubbuch, J.4
  • 6
    • 45149083380 scopus 로고    scopus 로고
    • High-throughput process development: determination of dynamic binding capacity using microtiter filter plates filled with chromatography resin
    • Bergander T., Nilsson-Välimaa K., Öberg K., Lacki K. High-throughput process development: determination of dynamic binding capacity using microtiter filter plates filled with chromatography resin. Biotechnol. Prog. 2008, 24:632-639.
    • (2008) Biotechnol. Prog. , vol.24 , pp. 632-639
    • Bergander, T.1    Nilsson-Välimaa, K.2    Öberg, K.3    Lacki, K.4
  • 7
    • 0026799147 scopus 로고
    • Steric mass-action ion exchange: displacement profiles and induced salt gradients
    • Brooks C., Cramer S. Steric mass-action ion exchange: displacement profiles and induced salt gradients. AIChE J. 1992, 38:1969-1978.
    • (1992) AIChE J. , vol.38 , pp. 1969-1978
    • Brooks, C.1    Cramer, S.2
  • 8
    • 42049092298 scopus 로고    scopus 로고
    • A systematic approach for modeling chromatographic processes - application to protein purification
    • Chan S., Titchener-Hooker N., Bracewell D., Sorensen E. A systematic approach for modeling chromatographic processes - application to protein purification. AIChE J. 2008, 54(4):965-977.
    • (2008) AIChE J. , vol.54 , Issue.4 , pp. 965-977
    • Chan, S.1    Titchener-Hooker, N.2    Bracewell, D.3    Sorensen, E.4
  • 9
    • 46249092863 scopus 로고    scopus 로고
    • High-throughput screening of chromatographic separations: I. Method development and column modeling
    • Coffman J., Kramarczyk J., Kelley B. High-throughput screening of chromatographic separations: I. Method development and column modeling. Biotechnol. Bioeng. 2008, 100(4):605-618.
    • (2008) Biotechnol. Bioeng. , vol.100 , Issue.4 , pp. 605-618
    • Coffman, J.1    Kramarczyk, J.2    Kelley, B.3
  • 10
    • 24444437044 scopus 로고
    • Continuous flow systems: distribution of residence times
    • Danckwerts P. Continuous flow systems: distribution of residence times. Chem. Eng. Sci. 1953, 2(1):1-13.
    • (1953) Chem. Eng. Sci. , vol.2 , Issue.1 , pp. 1-13
    • Danckwerts, P.1
  • 11
    • 74949107000 scopus 로고    scopus 로고
    • 3D structure-based protein retention prediction for ion-exchange chromatography
    • Dismer F., Hubbuch J. 3D structure-based protein retention prediction for ion-exchange chromatography. J. Chromatogr. A 2010, 1217(8):1343-1353.
    • (2010) J. Chromatogr. A , vol.1217 , Issue.8 , pp. 1343-1353
    • Dismer, F.1    Hubbuch, J.2
  • 14
    • 84861424923 scopus 로고    scopus 로고
    • F.D.A.U.S. Department of Health and Human Services, (Ed.), Guidance for Industry PAT-A Framework for Innovative Pharmaceutical Manufacturing and Quality Assurance.
    • F.D.A.U.S. Department of Health and Human Services, 2004. (Ed.), Guidance for Industry PAT-A Framework for Innovative Pharmaceutical Manufacturing and Quality Assurance.
    • (2004)
  • 15
    • 0027528419 scopus 로고
    • Characterization of non-linear adsorption properties of dextran-based polyelectrolyte displacers in ion-exchange systems
    • Gadam S., Jayaraman G., Cramer S. Characterization of non-linear adsorption properties of dextran-based polyelectrolyte displacers in ion-exchange systems. Journal of Chromatography A 1993, 630(1-2):37-52.
    • (1993) Journal of Chromatography A , vol.630 , Issue.1-2 , pp. 37-52
    • Gadam, S.1    Jayaraman, G.2    Cramer, S.3
  • 16
    • 0030969458 scopus 로고    scopus 로고
    • Productivity and operating regimes in protein chromatography using low-molecular-mass displacers
    • Gallant S., Cramer S. Productivity and operating regimes in protein chromatography using low-molecular-mass displacers. J. Chromatogr. A 1997, 771:9-22.
    • (1997) J. Chromatogr. A , vol.771 , pp. 9-22
    • Gallant, S.1    Cramer, S.2
  • 17
    • 0029031318 scopus 로고
    • Modeling non-linear elution of proteins in ion-exchange chromatography
    • Gallant S., Kundu A., Cramer S. Modeling non-linear elution of proteins in ion-exchange chromatography. J. Chromatogr. A 1995, 702(1-2):125-142.
    • (1995) J. Chromatogr. A , vol.702 , Issue.1-2 , pp. 125-142
    • Gallant, S.1    Kundu, A.2    Cramer, S.3
  • 18
    • 77957675442 scopus 로고    scopus 로고
    • Integration of scale-down experimentation and general rate modelling to predict manufacturing scale chromatographic separations
    • Gerontas S., Asplund M., Hjorth R., Bracewell D. Integration of scale-down experimentation and general rate modelling to predict manufacturing scale chromatographic separations. J. Chromatogr. A 2010, 1217(44):6917-6926.
    • (2010) J. Chromatogr. A , vol.1217 , Issue.44 , pp. 6917-6926
    • Gerontas, S.1    Asplund, M.2    Hjorth, R.3    Bracewell, D.4
  • 19
    • 0037008247 scopus 로고    scopus 로고
    • Preparative liquid chromatography
    • Guiochon G. Preparative liquid chromatography. J. Chromatogr. A 2002, 965(1-2):129-161.
    • (2002) J. Chromatogr. A , vol.965 , Issue.1-2 , pp. 129-161
    • Guiochon, G.1
  • 20
    • 80053051745 scopus 로고    scopus 로고
    • A label-free methodology for selective protein quantification by means of absorption measurements
    • Hansen S.K., Skibsted E., Staby A., Hubbuch J. A label-free methodology for selective protein quantification by means of absorption measurements. Biotechnol. Bioeng. 2011, 108(11):2661-2669.
    • (2011) Biotechnol. Bioeng. , vol.108 , Issue.11 , pp. 2661-2669
    • Hansen, S.K.1    Skibsted, E.2    Staby, A.3    Hubbuch, J.4
  • 21
    • 33745040493 scopus 로고    scopus 로고
    • Generation of equally sized particle plaques using solid-liquid suspensions
    • Herrmann T., Schroeder M., Hubbuch J. Generation of equally sized particle plaques using solid-liquid suspensions. Biotechnol. Prog. 2006, 22(3):914-918.
    • (2006) Biotechnol. Prog. , vol.22 , Issue.3 , pp. 914-918
    • Herrmann, T.1    Schroeder, M.2    Hubbuch, J.3
  • 22
    • 0032969577 scopus 로고    scopus 로고
    • Use of the steric mass action model in ion-exchange chromatographic process development
    • Iyer H., Tapper S., Lester P., Wolk B., van Reis R. Use of the steric mass action model in ion-exchange chromatographic process development. J. Chromatogr. A 1999, 832:1-9.
    • (1999) J. Chromatogr. A , vol.832 , pp. 1-9
    • Iyer, H.1    Tapper, S.2    Lester, P.3    Wolk, B.4    van Reis, R.5
  • 23
    • 11344294824 scopus 로고    scopus 로고
    • Using computer simulation to assist in the robustness analysis of an ion-exchange chromatography step
    • Jakobsson N., Karlsson D., Axelsson J., Zacchi G., Nilsson B. Using computer simulation to assist in the robustness analysis of an ion-exchange chromatography step. J. Chromatogr. A 2005, 1063(1-21-2):99-109.
    • (2005) J. Chromatogr. A , vol.1063 , Issue.1-21 , pp. 99-109
    • Jakobsson, N.1    Karlsson, D.2    Axelsson, J.3    Zacchi, G.4    Nilsson, B.5
  • 24
    • 33748057502 scopus 로고    scopus 로고
    • Exploiting bootstrap method for quantifying parameter confidence intervals in dynamical systems
    • Joshi M., Seidel-Morgenstern A., Kremling A. Exploiting bootstrap method for quantifying parameter confidence intervals in dynamical systems. Metab. Eng. 2006, 8:447-455.
    • (2006) Metab. Eng. , vol.8 , pp. 447-455
    • Joshi, M.1    Seidel-Morgenstern, A.2    Kremling, A.3
  • 25
    • 84970064105 scopus 로고
    • Chromatography: 1989 report
    • Knight P. Chromatography: 1989 report. Biotechnology 1989, 7:243-249.
    • (1989) Biotechnology , vol.7 , pp. 243-249
    • Knight, P.1
  • 26
    • 23844493072 scopus 로고    scopus 로고
    • A priori prediction of adsorption isotherm parameters and chromatographic behavior in ion-exchange systems
    • Ladiwala A., Rege K., Breneman C., Cramer S., Prausnitz J. A priori prediction of adsorption isotherm parameters and chromatographic behavior in ion-exchange systems. Proc. Natl. Acad. Sci. USA 2005, 102(33):11710-11715.
    • (2005) Proc. Natl. Acad. Sci. USA , vol.102 , Issue.33 , pp. 11710-11715
    • Ladiwala, A.1    Rege, K.2    Breneman, C.3    Cramer, S.4    Prausnitz, J.5
  • 28
    • 35348910088 scopus 로고    scopus 로고
    • Development, modelling, optimisation and scale-up of chromatographic purification of a therapeutic protein
    • Mollerup J., Hansen T., Kidal S., Sejergaard L., Staby A. Development, modelling, optimisation and scale-up of chromatographic purification of a therapeutic protein. Fluid Phase Equilib. 2007, 261(1-2):133-139.
    • (2007) Fluid Phase Equilib. , vol.261 , Issue.1-2 , pp. 133-139
    • Mollerup, J.1    Hansen, T.2    Kidal, S.3    Sejergaard, L.4    Staby, A.5
  • 29
    • 84858617284 scopus 로고    scopus 로고
    • Determination of parameters for the steric mass action model-a comparison between two approaches
    • Osberghaus A., Hepbildikler S., Nath S., Haindl M., von Lieres E., Hubbuch J. Determination of parameters for the steric mass action model-a comparison between two approaches. J. Chromatogr. A 2012, 1233(1):54-65.
    • (2012) J. Chromatogr. A , vol.1233 , Issue.1 , pp. 54-65
    • Osberghaus, A.1    Hepbildikler, S.2    Nath, S.3    Haindl, M.4    von Lieres, E.5    Hubbuch, J.6
  • 30
    • 84859652583 scopus 로고    scopus 로고
    • Optimizing a chromatographic three component separation: a comparison of mechanistic and empiric modeling approaches
    • Osberghaus A., Hepbildikler S., Nath S., Haindl M., von Lieres E., Hubbuch J. Optimizing a chromatographic three component separation: a comparison of mechanistic and empiric modeling approaches. J. Chromatogr. A 2012, 1237(1):86-95.
    • (2012) J. Chromatogr. A , vol.1237 , Issue.1 , pp. 86-95
    • Osberghaus, A.1    Hepbildikler, S.2    Nath, S.3    Haindl, M.4    von Lieres, E.5    Hubbuch, J.6
  • 31
    • 4143077454 scopus 로고    scopus 로고
    • D-optimal onion designs in statistical molecular design
    • Olsson I., Gottfries J., Wold S. D-optimal onion designs in statistical molecular design. Chemomet. Intell. Lab. Syst. 2004, 73(1):37-46.
    • (2004) Chemomet. Intell. Lab. Syst. , vol.73 , Issue.1 , pp. 37-46
    • Olsson, I.1    Gottfries, J.2    Wold, S.3
  • 32
    • 0037725285 scopus 로고    scopus 로고
    • Whey proteins as a model system for chromatographic separation of proteins
    • Pedersen L., Mollerup J., Hansen E., Jungbauer A. Whey proteins as a model system for chromatographic separation of proteins. J. Chromatogr. B 2003, 790(1-2):161-173.
    • (2003) J. Chromatogr. B , vol.790 , Issue.1-2 , pp. 161-173
    • Pedersen, L.1    Mollerup, J.2    Hansen, E.3    Jungbauer, A.4
  • 33
    • 33646802922 scopus 로고    scopus 로고
    • Aspects of estimating parameter dependencies in a detailed chromatography model based on frontal experiments
    • Persson P., Gustavsson P., Zacchi G., Nilsson B. Aspects of estimating parameter dependencies in a detailed chromatography model based on frontal experiments. Process Biochem. 2006, 41(8):1812-1821.
    • (2006) Process Biochem. , vol.41 , Issue.8 , pp. 1812-1821
    • Persson, P.1    Gustavsson, P.2    Zacchi, G.3    Nilsson, B.4
  • 34
    • 0032194261 scopus 로고    scopus 로고
    • Synthesis and characterization of high-affinity, low molecular weight displacers for cation-exchange chromatography
    • Shukla A., Bae S., Moore J., Barnthouse K., Cramer S. Synthesis and characterization of high-affinity, low molecular weight displacers for cation-exchange chromatography. Ind. Eng. Chem. Res. 1998, 37(1010):4090-4098.
    • (1998) Ind. Eng. Chem. Res. , vol.37 , Issue.1010 , pp. 4090-4098
    • Shukla, A.1    Bae, S.2    Moore, J.3    Barnthouse, K.4    Cramer, S.5
  • 35
    • 60649086983 scopus 로고    scopus 로고
    • High throughput screening for the design and optimization of chromatographic processes assessment of model parameter determination from high throughput compatible data
    • Susanto A., Knieps-Grünhagen E., von Lieres E., Hubbuch J. High throughput screening for the design and optimization of chromatographic processes assessment of model parameter determination from high throughput compatible data. Chem. Eng. Technol. 2008, 31(12):1846-1855.
    • (2008) Chem. Eng. Technol. , vol.31 , Issue.12 , pp. 1846-1855
    • Susanto, A.1    Knieps-Grünhagen, E.2    von Lieres, E.3    Hubbuch, J.4
  • 36
    • 60849096390 scopus 로고    scopus 로고
    • High throughput screening for the design and optimization of chromatographic processes: automated optimization of chromatographic phase systems
    • Susanto A., Treier K., Knieps-Grünhagen E., von Lieres E., Hubbuch J. High throughput screening for the design and optimization of chromatographic processes: automated optimization of chromatographic phase systems. Chem. Eng. Technol. 2009, 32:140-154.
    • (2009) Chem. Eng. Technol. , vol.32 , pp. 140-154
    • Susanto, A.1    Treier, K.2    Knieps-Grünhagen, E.3    von Lieres, E.4    Hubbuch, J.5
  • 37
    • 84861433906 scopus 로고    scopus 로고
    • (Ed.), Preparative Chromatography. Wiley-VCH, Weinheim, Germany.
    • Schmidt-Traub, H. (Ed.), 2006. Preparative Chromatography. Wiley-VCH, Weinheim, Germany.
    • (2006)
    • Schmidt-Traub, H.1
  • 38
    • 67650938987 scopus 로고    scopus 로고
    • Predictive chromatographic simulations for the optimization of recovery and aggregate clearance during the capture of monoclonal antibodies
    • Teeters M., Benner T., Bezila D., Shen H., Velayudhan A., Alred P. Predictive chromatographic simulations for the optimization of recovery and aggregate clearance during the capture of monoclonal antibodies. J. Chromatogr. A 2009, 1216:6134-6140.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 6134-6140
    • Teeters, M.1    Benner, T.2    Bezila, D.3    Shen, H.4    Velayudhan, A.5    Alred, P.6
  • 39
    • 0035339873 scopus 로고    scopus 로고
    • Experimental verification and optimisation of a detailed dynamic high performance liquid chromatography column model
    • Teoh H., Turner M., Titchener-Hooker N., Sorensen E. Experimental verification and optimisation of a detailed dynamic high performance liquid chromatography column model. Comput. Chem. Eng. 2001, 25(4-6):893-903.
    • (2001) Comput. Chem. Eng. , vol.25 , Issue.4-6 , pp. 893-903
    • Teoh, H.1    Turner, M.2    Titchener-Hooker, N.3    Sorensen, E.4
  • 41
    • 42049092298 scopus 로고    scopus 로고
    • A systematic approach for modeling chromatographic processes: application to protein purification
    • Titchener-Hooker N., Chan S., Bracewell D. A systematic approach for modeling chromatographic processes: application to protein purification. AIChE J. 2008, 54(4):965-977.
    • (2008) AIChE J. , vol.54 , Issue.4 , pp. 965-977
    • Titchener-Hooker, N.1    Chan, S.2    Bracewell, D.3
  • 42
    • 0037625875 scopus 로고    scopus 로고
    • Predicting column performance in displacement chromatography from high throughput screening batch experiments
    • Tugcu N., Cramer S., Rege K. Predicting column performance in displacement chromatography from high throughput screening batch experiments. Sep. Sci. Technol. 2003, 38(7):1499-1517.
    • (2003) Sep. Sci. Technol. , vol.38 , Issue.7 , pp. 1499-1517
    • Tugcu, N.1    Cramer, S.2    Rege, K.3
  • 43
    • 46049105929 scopus 로고    scopus 로고
    • High throughput screening for the design and optimization of chromatographic processes: miniaturization, automation and parallelization of breakthrough and elution studies
    • Wiendahl M., Wierling P.S., Nielsen J., Christensen D.F., Krarup J., Staby A., Hubbuch J. High throughput screening for the design and optimization of chromatographic processes: miniaturization, automation and parallelization of breakthrough and elution studies. Chem. Eng. Technol. 2008, 31(6):893-903.
    • (2008) Chem. Eng. Technol. , vol.31 , Issue.6 , pp. 893-903
    • Wiendahl, M.1    Wierling, P.S.2    Nielsen, J.3    Christensen, D.F.4    Krarup, J.5    Staby, A.6    Hubbuch, J.7
  • 44
    • 36849043669 scopus 로고    scopus 로고
    • Prediction of pH-dependent chromatographic behavior in ion-exchange systems
    • Yang T., Sundling M., Freed A., Breneman C., Cramer S. Prediction of pH-dependent chromatographic behavior in ion-exchange systems. Anal. Chem. 2007, 79(23):8927-8939.
    • (2007) Anal. Chem. , vol.79 , Issue.23 , pp. 8927-8939
    • Yang, T.1    Sundling, M.2    Freed, A.3    Breneman, C.4    Cramer, S.5
  • 45
    • 77955551928 scopus 로고    scopus 로고
    • A fast and accurate solver for the general rate model of column liquid chromatography
    • von Lieres E., Andersson J. A fast and accurate solver for the general rate model of column liquid chromatography. Comput. Chem. Eng. 2010, 34(8):1180-1191.
    • (2010) Comput. Chem. Eng. , vol.34 , Issue.8 , pp. 1180-1191
    • von Lieres, E.1    Andersson, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.