메뉴 건너뛰기




Volumn 59, Issue , 2012, Pages 16-23

Non-bar, an optical calibration system for five-axis CNC machine tools

Author keywords

Five axis CNC machine tool; ISO CD 10791 6; Optical calibration system

Indexed keywords

BALL LENS; DETECTOR MODULE; FIVE-AXIS CNC MACHINES; HIGH REPRODUCIBILITY; ISO/CD 10791-6; MEASUREMENT METHODS; MEASUREMENT SYSTEM; MULTI-AXIS; OPTICAL CALIBRATION; WORK PIECES;

EID: 84860521995     PISSN: 08906955     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijmachtools.2012.01.004     Document Type: Article
Times cited : (56)

References (24)
  • 3
    • 84861631860 scopus 로고    scopus 로고
    • 2011 (20.01.11)
    • 〈http://www.heidenhain.com/machtool.html〉, 2011 (20.01.11).
  • 5
    • 18744370482 scopus 로고    scopus 로고
    • Development of a laser-based high-precision six-degrees-of-freedom motion errors measuring system for linear stage
    • C.H. Liu, W.Y. Jywe, C.C. Hsu, and T.H. Hsu Development of a laser-based high-precision six-degrees-of-freedom motion errors measuring system for linear stage Review of Scientific Instruments 76 5 2005 055110-1 055110-6
    • (2005) Review of Scientific Instruments , vol.76 , Issue.5 , pp. 0551101-0551106
    • Liu, C.H.1    Jywe, W.Y.2    Hsu, C.C.3    Hsu, T.H.4
  • 7
    • 84861635106 scopus 로고    scopus 로고
    • 2011 (20.01.11)
    • 〈http://www.renishaw.com/en/rx10-rotary-axis-calibrator - 6805〉, 2011 (20.01.11).
  • 8
    • 84861615451 scopus 로고    scopus 로고
    • 2011 (20.01.11)
    • 〈http://www.apisensor.com/swivelcheck〉, 2011 (20.01.11).
  • 9
    • 0001449925 scopus 로고
    • A simple method for separating spindle error from test ball sphericity error
    • R. Donaldson A simple method for separating spindle error from test ball sphericity error CIRP Annals 21 1972 125 126
    • (1972) CIRP Annals , vol.21 , pp. 125-126
    • Donaldson, R.1
  • 10
    • 0027205869 scopus 로고
    • Four-point method of sphericity and spindle error measurements
    • G.X. Zhang, and R.K. Wang Four-point method of sphericity and spindle error measurements CIRP Annals - Manufacturing Technology 42 1 1993 593 596
    • (1993) CIRP Annals - Manufacturing Technology , vol.42 , Issue.1 , pp. 593-596
    • Zhang, G.X.1    Wang, R.K.2
  • 11
    • 24944504773 scopus 로고    scopus 로고
    • Application of a diffraction grating and position sensitive detectors to the measurement of error motion and angular indexing of an indexing table
    • C.H. Liu, W.Y. Jywe, L.H. Shyu, and Chun-Jen Chen Application of a diffraction grating and position sensitive detectors to the measurement of error motion and angular indexing of an indexing table Precision Engineering 29 4 2005 440 448
    • (2005) Precision Engineering , vol.29 , Issue.4 , pp. 440-448
    • Liu, C.H.1    Jywe, W.Y.2    Shyu, L.H.3    Chen, C.-J.4
  • 12
    • 35948978954 scopus 로고    scopus 로고
    • An optoelectronic measurement system for measuring 6-degree-of-freedom motion error of rotary parts
    • C.J. Chen, P.D. Lin, and W.Y. Jywe An optoelectronic measurement system for measuring 6-degree-of-freedom motion error of rotary parts Optics Express 15 22 2007 14601 14617
    • (2007) Optics Express , vol.15 , Issue.22 , pp. 14601-14617
    • Chen, C.J.1    Lin, P.D.2    Jywe, W.Y.3
  • 15
    • 77957943630 scopus 로고    scopus 로고
    • Kinematic error separation on five-axis NC machine tool based on telescoping double ball bar
    • M. Wang, J. Hu, and T. Zan Kinematic error separation on five-axis NC machine tool based on telescoping double ball bar Frontiers of Mechanical Engineering in China 5 4 2010 431 437
    • (2010) Frontiers of Mechanical Engineering in China , vol.5 , Issue.4 , pp. 431-437
    • Wang, M.1    Hu, J.2    Zan, T.3
  • 16
    • 0036686211 scopus 로고    scopus 로고
    • Accuracy test of five-axis CNC machine tool with 3D probe-ball. Part II: Errors estimation
    • W.T. Lei, and Y.Y. Hsu Accuracy test of five-axis CNC machine tool with 3D probe-ball. Part II: errors estimation International Journal of Machine Tools and Manufacture 42 10 2002 1163 1170
    • (2002) International Journal of Machine Tools and Manufacture , vol.42 , Issue.10 , pp. 1163-1170
    • Lei, W.T.1    Hsu, Y.Y.2
  • 17
    • 3142684582 scopus 로고    scopus 로고
    • R-test, a new device for accuracy measurements on five axis machine tools
    • S. Weikert R-test, a new device for accuracy measurements on five axis machine tools CIRP Annals - Manufacturing Technology 53 1 2004 429 432
    • (2004) CIRP Annals - Manufacturing Technology , vol.53 , Issue.1 , pp. 429-432
    • Weikert, S.1
  • 18
    • 33745144135 scopus 로고    scopus 로고
    • Model-based 'Chase-the-Ball' calibration of a 5-axes machining center
    • B. Bringmann, and W. Knapp Model-based 'Chase-the-Ball' calibration of a 5-axes machining center CIRP Annals - Manufacturing Technology 55 1 2006 531 534
    • (2006) CIRP Annals - Manufacturing Technology , vol.55 , Issue.1 , pp. 531-534
    • Bringmann, B.1    Knapp, W.2
  • 19
    • 67349173912 scopus 로고    scopus 로고
    • On-the-y calibration of linear and rotary axes of machine tools and CMMs using a tracking interferometer
    • H. Schwenke, R. Schmitt, P. Jatzkowski, and C. Warmann On-the-y calibration of linear and rotary axes of machine tools and CMMs using a tracking interferometer CIRP Annals - Manufacturing Technology 58 1 2009 477 480
    • (2009) CIRP Annals - Manufacturing Technology , vol.58 , Issue.1 , pp. 477-480
    • Schwenke, H.1    Schmitt, R.2    Jatzkowski, P.3    Warmann, C.4
  • 22
    • 84861643568 scopus 로고    scopus 로고
    • 2011 (05.08.11)
    • 〈http://seagull.ukzn.ac.za/mukaror/L9.pdf〉, 2011 (05.08.11).
  • 23
    • 84861615453 scopus 로고    scopus 로고
    • 2011 (05.08.11)
    • 〈http://refractiveindex.info/?group=LIQUIDS&material= BK7-MATCHING〉, 2011 (05.08.11).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.