메뉴 건너뛰기




Volumn 30, Issue 5, 2012, Pages 627-640

Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus

Author keywords

Deep brain stimulation; Multiecho FLASH; Parkinson's disease; Subthalamic nucleus; Susceptibility weighted imaging

Indexed keywords

ADULT; ARTICLE; BASAL GANGLION; BRAIN DEPTH STIMULATION; CASE REPORT; CLINICAL PROTOCOL; CONTRAST ENHANCEMENT; CONTRAST NOISE RATIO; CONTROLLED STUDY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE PROCESSING; IMAGE QUALITY; IN VIVO STUDY; MALE; MULTICONTRAST MULTIECHO FAST LOW ANGLE SHOT MAGNETIC RESONANCE IMAGING; NEURONAVIGATION; NOISE MEASUREMENT; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PARKINSON DISEASE; PRIORITY JOURNAL; PROCESS OPTIMIZATION; PROTON NUCLEAR MAGNETIC RESONANCE; RADIOLOGICAL PARAMETERS; SIGNAL NOISE RATIO; SIMULATION; SUBTHALAMIC NUCLEUS; SUSCEPTIBILITY WEIGHTED IMAGING;

EID: 84860464802     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2012.02.006     Document Type: Article
Times cited : (37)

References (34)
  • 2
    • 0042922748 scopus 로고    scopus 로고
    • Long-term follow up of bilateral deep brain stimulation of the subthalamic nucleus in patients with advanced Parkinson disease
    • Kleiner-Fisman G., Fisman D.N., Sime E., Saint-Cyr J.A., Lozano A.M., Lang A.E. Long-term follow up of bilateral deep brain stimulation of the subthalamic nucleus in patients with advanced Parkinson disease. J Neurosurg 2003, 99(3):489-495.
    • (2003) J Neurosurg , vol.99 , Issue.3 , pp. 489-495
    • Kleiner-Fisman, G.1    Fisman, D.N.2    Sime, E.3    Saint-Cyr, J.A.4    Lozano, A.M.5    Lang, A.E.6
  • 3
    • 1442307165 scopus 로고    scopus 로고
    • Determining the position and size of the subthalamic nucleus based on magnetic resonance imaging results in patients with advanced Parkinson disease
    • Richter E.O., Hoque T., Halliday W., Lozano A.M., Saint-Cyr J.A. Determining the position and size of the subthalamic nucleus based on magnetic resonance imaging results in patients with advanced Parkinson disease. J Neurosurg 2004, 100(3):541-546.
    • (2004) J Neurosurg , vol.100 , Issue.3 , pp. 541-546
    • Richter, E.O.1    Hoque, T.2    Halliday, W.3    Lozano, A.M.4    Saint-Cyr, J.A.5
  • 5
    • 33644858984 scopus 로고    scopus 로고
    • Direct visualization of the human subthalamic nucleus with 3T MR imaging
    • Slavin K.V., Thulborn K.R., Wess C., Nersesyan H. Direct visualization of the human subthalamic nucleus with 3T MR imaging. AJNR Am J Neuroradiol 2006, 27(1):80-84.
    • (2006) AJNR Am J Neuroradiol , vol.27 , Issue.1 , pp. 80-84
    • Slavin, K.V.1    Thulborn, K.R.2    Wess, C.3    Nersesyan, H.4
  • 6
    • 79551687582 scopus 로고    scopus 로고
    • Comparison of different targeting methods for subthalamic nucleus deep brain stimulation. Medical image computing and computer-assisted intervention: MICCAI
    • Guo T., Finnis K.W., Deoni S.C., Parrent A.G., Peters T.M. Comparison of different targeting methods for subthalamic nucleus deep brain stimulation. Medical image computing and computer-assisted intervention: MICCAI. Int Conf Med Image Comput Comput-Assist Interv 2006, 9(Pt 1):768-775.
    • (2006) Int Conf Med Image Comput Comput-Assist Interv , vol.9 , Issue.PART 1 , pp. 768-775
    • Guo, T.1    Finnis, K.W.2    Deoni, S.C.3    Parrent, A.G.4    Peters, T.M.5
  • 7
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    • Deoni S.C., Rutt B.K., Peters T.M. Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med 2003, 49(3):515-526.
    • (2003) Magn Reson Med , vol.49 , Issue.3 , pp. 515-526
    • Deoni, S.C.1    Rutt, B.K.2    Peters, T.M.3
  • 8
    • 12144277049 scopus 로고    scopus 로고
    • High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2
    • Deoni S.C., Peters T.M., Rutt B.K. High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2. Magn Reson Med 2005, 53(1):237-241.
    • (2005) Magn Reson Med , vol.53 , Issue.1 , pp. 237-241
    • Deoni, S.C.1    Peters, T.M.2    Rutt, B.K.3
  • 9
    • 67651174306 scopus 로고    scopus 로고
    • A high resolution and high contrast MRI for differentiation of subcortical structures for DBS targeting: the fast gray matter acquisition T1 inversion recovery (FGATIR)
    • Sudhyadhom A., Haq I.U., Foote K.D., Okun M.S., Bova F.J. A high resolution and high contrast MRI for differentiation of subcortical structures for DBS targeting: the fast gray matter acquisition T1 inversion recovery (FGATIR). NeuroImage 2009, 47(Suppl 2):T44-52.
    • (2009) NeuroImage , vol.47 , Issue.SUPPL. 2
    • Sudhyadhom, A.1    Haq, I.U.2    Foote, K.D.3    Okun, M.S.4    Bova, F.J.5
  • 11
    • 0037810601 scopus 로고    scopus 로고
    • Three-dimensional database of subcortical electrophysiology for image-guided stereotactic functional neurosurgery
    • Finnis K.W., Starreveld Y.P., Parrent A.G., Sadikot A.F., Peters T.M. Three-dimensional database of subcortical electrophysiology for image-guided stereotactic functional neurosurgery. IEEE Trans Med Imaging 2003, 22(1):93-104.
    • (2003) IEEE Trans Med Imaging , vol.22 , Issue.1 , pp. 93-104
    • Finnis, K.W.1    Starreveld, Y.P.2    Parrent, A.G.3    Sadikot, A.F.4    Peters, T.M.5
  • 12
    • 33744799452 scopus 로고    scopus 로고
    • Development and application of functional databases for planning deep-brain neurosurgical procedures. Medical image computing and computer-assisted intervention: MICCAI
    • Guo T., Finnis K.W., Parrent A.G., Peters T.M. Development and application of functional databases for planning deep-brain neurosurgical procedures. Medical image computing and computer-assisted intervention: MICCAI. Int Conf Med Image Comput Comput-Assist Int 2005, 8(Pt 1):835-842.
    • (2005) Int Conf Med Image Comput Comput-Assist Int , vol.8 , Issue.PART 1 , pp. 835-842
    • Guo, T.1    Finnis, K.W.2    Parrent, A.G.3    Peters, T.M.4
  • 13
    • 70349894964 scopus 로고    scopus 로고
    • Localization of the subthalamic nucleus: optimization with susceptibility-weighted phase MR imaging
    • Vertinsky A.T., Coenen V.A., Lang D.J., Kolind S., Honey C.R., Li D., Rauscher A. Localization of the subthalamic nucleus: optimization with susceptibility-weighted phase MR imaging. AJNR Am J Neuroradiol 2009, 30(9):1717-1724.
    • (2009) AJNR Am J Neuroradiol , vol.30 , Issue.9 , pp. 1717-1724
    • Vertinsky, A.T.1    Coenen, V.A.2    Lang, D.J.3    Kolind, S.4    Honey, C.R.5    Li, D.6    Rauscher, A.7
  • 16
    • 74049143836 scopus 로고    scopus 로고
    • Susceptibility weighted imaging with multiple echoes
    • Denk C., Rauscher A. Susceptibility weighted imaging with multiple echoes. J Magn Reson Imaging: JMRI 2010, 31(1):185-191.
    • (2010) J Magn Reson Imaging: JMRI , vol.31 , Issue.1 , pp. 185-191
    • Denk, C.1    Rauscher, A.2
  • 17
    • 57049102449 scopus 로고    scopus 로고
    • Advantages of using multiple-echo image combination and asymmetric triangular phase masking in magnetic resonance venography at 3 T
    • Brainovich V., Sabatini U., Hagberg G.E. Advantages of using multiple-echo image combination and asymmetric triangular phase masking in magnetic resonance venography at 3 T. Magn Reson Imaging 2009, 27(1):23-37.
    • (2009) Magn Reson Imaging , vol.27 , Issue.1 , pp. 23-37
    • Brainovich, V.1    Sabatini, U.2    Hagberg, G.E.3
  • 18
    • 60349117378 scopus 로고    scopus 로고
    • Increased SNR and reduced distortions by averaging multiple gradient echo signals in 3D FLASH imaging of the human brain at 3T
    • Helms G., Dechent P. Increased SNR and reduced distortions by averaging multiple gradient echo signals in 3D FLASH imaging of the human brain at 3T. J Magn Reson Imaging: JMRI 2009, 29(1):198-204.
    • (2009) J Magn Reson Imaging: JMRI , vol.29 , Issue.1 , pp. 198-204
    • Helms, G.1    Dechent, P.2
  • 19
    • 33748658691 scopus 로고    scopus 로고
    • Reliability of MRI-derived measurements of human cerebral cortical thickness: the effects of field strength, scanner upgrade and manufacturer
    • Han X., Jovicich J., Salat D., van der Kouwe A., Quinn B., Czanner S., Busa E., Pacheco J., Albert M., Killiany R., et al. Reliability of MRI-derived measurements of human cerebral cortical thickness: the effects of field strength, scanner upgrade and manufacturer. NeuroImage 2006, 32(1):180-194.
    • (2006) NeuroImage , vol.32 , Issue.1 , pp. 180-194
    • Han, X.1    Jovicich, J.2    Salat, D.3    van der Kouwe, A.4    Quinn, B.5    Czanner, S.6    Busa, E.7    Pacheco, J.8    Albert, M.9    Killiany, R.10
  • 22
    • 58249096160 scopus 로고    scopus 로고
    • Susceptibility-weighted imaging: technical aspects and clinical applications, part 1
    • Haacke E.M., Mittal S., Wu Z., Neelavalli J., Cheng Y.C. Susceptibility-weighted imaging: technical aspects and clinical applications, part 1. AJNR Am J Neuroradiol 2009, 30(1):19-30.
    • (2009) AJNR Am J Neuroradiol , vol.30 , Issue.1 , pp. 19-30
    • Haacke, E.M.1    Mittal, S.2    Wu, Z.3    Neelavalli, J.4    Cheng, Y.C.5
  • 23
    • 74049149737 scopus 로고    scopus 로고
    • A population-specific symmetric phase model to automatically analyze susceptibility-weighted imaging (SWI) phase shifts and phase symmetry in the human brain
    • Grabner G., Haubenberger D., Rath J., Beisteiner R., Auff E., Trattnig S., Barth M. A population-specific symmetric phase model to automatically analyze susceptibility-weighted imaging (SWI) phase shifts and phase symmetry in the human brain. J Magn Reson Imaging: JMRI 2010, 31(1):215-220.
    • (2010) J Magn Reson Imaging: JMRI , vol.31 , Issue.1 , pp. 215-220
    • Grabner, G.1    Haubenberger, D.2    Rath, J.3    Beisteiner, R.4    Auff, E.5    Trattnig, S.6    Barth, M.7
  • 25
    • 70049114375 scopus 로고    scopus 로고
    • Comparison of pulsed arterial spin labeling encoding schemes and absolute perfusion quantification
    • Cavusoglu M., Pfeuffer J., Ugurbil K., Uludag K. Comparison of pulsed arterial spin labeling encoding schemes and absolute perfusion quantification. Magn Reson Imaging 2009, 27(8):1039-1045.
    • (2009) Magn Reson Imaging , vol.27 , Issue.8 , pp. 1039-1045
    • Cavusoglu, M.1    Pfeuffer, J.2    Ugurbil, K.3    Uludag, K.4
  • 27
    • 38749108583 scopus 로고    scopus 로고
    • Magnetic resonance imaging: physical principles and sequence design
    • New York: Wiley-Liss
    • Haacke EM. Magnetic resonance imaging: physical principles and sequence design. New York: Wiley-Liss; 1999. xxvii, 914 p. p.
    • (1999) , vol.27 , pp. 914
    • Haacke, E.M.1
  • 29
    • 0033013737 scopus 로고    scopus 로고
    • MR imaging of human brain at 3.0 T: preliminary report on transverse relaxation rates and relation to estimated iron content
    • Gelman N., Gorell J.M., Barker P.B., Savage R.M., Spickler E.M., Windham J.P., Knight R.A. MR imaging of human brain at 3.0 T: preliminary report on transverse relaxation rates and relation to estimated iron content. Radiology 1999, 210(3):759-767.
    • (1999) Radiology , vol.210 , Issue.3 , pp. 759-767
    • Gelman, N.1    Gorell, J.M.2    Barker, P.B.3    Savage, R.M.4    Spickler, E.M.5    Windham, J.P.6    Knight, R.A.7
  • 30
    • 0035157986 scopus 로고    scopus 로고
    • Interregional variation of longitudinal relaxation rates in human brain at 3.0 T: relation to estimated iron and water contents
    • Gelman N., Ewing J.R., Gorell J.M., Spickler E.M., Solomon E.G. Interregional variation of longitudinal relaxation rates in human brain at 3.0 T: relation to estimated iron and water contents. Magn Reson Med 2001, 45(1):71-79.
    • (2001) Magn Reson Med , vol.45 , Issue.1 , pp. 71-79
    • Gelman, N.1    Ewing, J.R.2    Gorell, J.M.3    Spickler, E.M.4    Solomon, E.G.5
  • 32
    • 0030726766 scopus 로고    scopus 로고
    • Signal-to-noise measurements in magnitude images from NMR phased arrays
    • Constantinides C.D., Atalar E., McVeigh E.R. Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med 1997, 38(5):852-857.
    • (1997) Magn Reson Med , vol.38 , Issue.5 , pp. 852-857
    • Constantinides, C.D.1    Atalar, E.2    McVeigh, E.R.3
  • 33
    • 0346373773 scopus 로고    scopus 로고
    • Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla
    • de Zwart J.A., Ledden P.J., van Gelderen P., Bodurka J., Chu R., Duyn J.H. Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla. Magn Reson Med 2004, 51(1):22-26.
    • (2004) Magn Reson Med , vol.51 , Issue.1 , pp. 22-26
    • de Zwart, J.A.1    Ledden, P.J.2    van Gelderen, P.3    Bodurka, J.4    Chu, R.5    Duyn, J.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.