메뉴 건너뛰기




Volumn 43, Issue 5, 2001, Pages 364-369

High-resolution blood oxygen-level dependent MR venography (HRBV): A new technique

Author keywords

Magnetic resonance angiography; Vascular malformations

Indexed keywords

CONTRAST MEDIUM; OXYGEN;

EID: 0035006134     PISSN: 00283940     EISSN: None     Source Type: Journal    
DOI: 10.1007/s002340000503     Document Type: Article
Times cited : (91)

References (14)
  • 1
  • 2
    • 0030981629 scopus 로고    scopus 로고
    • Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent
    • Reichenbach JR, Venkatesan R, Schillinger DJ, Kido D, Haacke EM (1997) Small vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent. Radiology 204: 272-277
    • (1997) Radiology , vol.204 , pp. 272-277
    • Reichenbach, J.R.1    Venkatesan, R.2    Schillinger, D.J.3    Kido, D.4    Haacke, E.M.5
  • 4
    • 0025336246 scopus 로고
    • Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
    • Ogawa S, Lee TM, Nayak AS, Glynn P (1990) Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields. Magn Reson Med 14: 68-78
    • (1990) Magn Reson Med , vol.14 , pp. 68-78
    • Ogawa, S.1    Lee, T.M.2    Nayak, A.S.3    Glynn, P.4
  • 5
    • 0026447235 scopus 로고
    • Venous angioma of the brain: History, significance, and imaging findings
    • Truwit CL (1992) Venous angioma of the brain: history, significance, and imaging findings. Am J Roentgenol 159: 1299-1307
    • (1992) Am J Roentgenol , vol.159 , pp. 1299-1307
    • Truwit, C.L.1
  • 6
    • 0031841957 scopus 로고    scopus 로고
    • The caput medusae sign
    • Saba PR (1998) The caput medusae sign. Radiology 207: 599-600
    • (1998) Radiology , vol.207 , pp. 599-600
    • Saba, P.R.1
  • 8
    • 0032795041 scopus 로고    scopus 로고
    • MR high-resolution blood oxygenation level-dependent venography of occult (low-flow) vascular lesions
    • Lee BCP, Vo KD, Kido DK, Mukherjee P, Reichenbach J, Lin W, Yoon MS, Haacke M (1999) MR high-resolution blood oxygenation level-dependent venography of occult (low-flow) vascular lesions. AJNR 20: 1239-1242
    • (1999) AJNR , vol.20 , pp. 1239-1242
    • Lee, B.C.P.1    Vo, K.D.2    Kido, D.K.3    Mukherjee, P.4    Reichenbach, J.5    Lin, W.6    Yoon Ms, H.M.7
  • 10
    • 0031907748 scopus 로고    scopus 로고
    • Dural sinus thrombosis: Findings on CT and MR imaging and diagnostic pitfalls
    • Provenzale JM, Joseph GJ, Barboriak DP (1998) Dural sinus thrombosis: findings on CT and MR imaging and diagnostic pitfalls. Am J Roentgenol 170: 777-783
    • (1998) Am J Roentgenol , vol.170 , pp. 777-783
    • Provenzale, J.M.1    Joseph, G.J.2    Barboriak, D.P.3
  • 12
    • 0030986897 scopus 로고    scopus 로고
    • MRA of venous sinus thrombosis
    • Wang AM. (1997) MRA of venous sinus thrombosis. Clin Neurosci 4: 158-164
    • (1997) Clin Neurosci , vol.4 , pp. 158-164
    • Wang, A.M.1
  • 13
    • 0027251821 scopus 로고
    • Cavernous hemangiomas: Dipolar susceptibility artifacts at MR imaging
    • Kim JK, Kucharczyk W, Henkelman RM (1993) Cavernous hemangiomas: dipolar susceptibility artifacts at MR imaging. Radiology 187: 735-741
    • (1993) Radiology , vol.187 , pp. 735-741
    • Kim, J.K.1    Kucharczyk, W.2    Henkelman, R.M.3
  • 14
    • 0032773630 scopus 로고    scopus 로고
    • Improving high-resolution MR BOLD venography imaging using a T1 reducing contrast agent
    • Lin W, Mukherjee P, An H, Yu Y, Wang Y, Vo K, Lee B, Kido D, Haacke EM (1999) Improving high-resolution MR BOLD venography imaging using a T1 reducing contrast agent. JMRI 10: 118-123
    • (1999) JMRI , vol.10 , pp. 118-123
    • Lin, W.1    Mukherjee, P.2    An, H.3    Yu, Y.4    Wang, Y.5    Vo, K.6    Lee, B.7    Kido, D.8    Haacke, E.M.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.