메뉴 건너뛰기




Volumn 28, Issue 2, 2012, Pages 185-198

Avoiding and Treating Perioperative Complications of Distal Radius Fractures

Author keywords

Distal radius; Fracture; Perioperative complication; Treatment

Indexed keywords

ANTIBIOTIC AGENT; ASCORBIC ACID;

EID: 84860449957     PISSN: 07490712     EISSN: 15581969     Source Type: Journal    
DOI: 10.1016/j.hcl.2012.03.004     Document Type: Review
Times cited : (29)

References (107)
  • 1
    • 0034837212 scopus 로고    scopus 로고
    • Assessment of complications of distal radius fractures and development of a complication checklist
    • McKay S.D., MacDermid J.C., Roth J.H., et al. Assessment of complications of distal radius fractures and development of a complication checklist. J Hand Surg Am 2001, 26(5):916-922.
    • (2001) J Hand Surg Am , vol.26 , Issue.5 , pp. 916-922
    • McKay, S.D.1    MacDermid, J.C.2    Roth, J.H.3
  • 2
    • 0018411141 scopus 로고
    • Rupture of the extensor pollicis longus tendon after fracture of the lower end of the radius-a clinical and microangiographic study
    • Engkvist O., Lundborg G. Rupture of the extensor pollicis longus tendon after fracture of the lower end of the radius-a clinical and microangiographic study. Hand 1979, 11(1):76-86.
    • (1979) Hand , vol.11 , Issue.1 , pp. 76-86
    • Engkvist, O.1    Lundborg, G.2
  • 3
    • 79959834851 scopus 로고    scopus 로고
    • Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study
    • Yu Y.R., Makhni M.C., Tabrizi S., et al. Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. J Hand Surg Am 2011, 36(7):1135-1141.
    • (2011) J Hand Surg Am , vol.36 , Issue.7 , pp. 1135-1141
    • Yu, Y.R.1    Makhni, M.C.2    Tabrizi, S.3
  • 4
    • 0030928604 scopus 로고    scopus 로고
    • Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures
    • Ring D., Jupiter J.B., Brennwald J., et al. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg Am 1997, 22(5):777-784.
    • (1997) J Hand Surg Am , vol.22 , Issue.5 , pp. 777-784
    • Ring, D.1    Jupiter, J.B.2    Brennwald, J.3
  • 5
    • 0141889322 scopus 로고    scopus 로고
    • Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius
    • Rozental T.D., Beredjiklian P.K., Bozentka D.J. Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius. J Bone Joint Surg Am 2003, 85(10):1956-1960.
    • (2003) J Bone Joint Surg Am , vol.85 , Issue.10 , pp. 1956-1960
    • Rozental, T.D.1    Beredjiklian, P.K.2    Bozentka, D.J.3
  • 6
    • 0036068485 scopus 로고    scopus 로고
    • Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures
    • Chiang P.P., Roach S., Baratz M.E. Failure of a retinacular flap to prevent dorsal wrist pain after titanium Pi plate fixation of distal radius fractures. J Hand Surg Am 2002, 27(4):724-728.
    • (2002) J Hand Surg Am , vol.27 , Issue.4 , pp. 724-728
    • Chiang, P.P.1    Roach, S.2    Baratz, M.E.3
  • 7
    • 12344260484 scopus 로고    scopus 로고
    • Coverage of distal radius internal fixation and wrist fusion devices with AlloDerm
    • Althausen P.L., Szabo R.M. Coverage of distal radius internal fixation and wrist fusion devices with AlloDerm. Tech Hand Up Extrem Surg 2004, 8(4):266-268.
    • (2004) Tech Hand Up Extrem Surg , vol.8 , Issue.4 , pp. 266-268
    • Althausen, P.L.1    Szabo, R.M.2
  • 8
    • 78650758688 scopus 로고    scopus 로고
    • Fracture of the distal radius: risk factors for complications after locked volar plate fixation
    • Soong M., van Leerdam R., Guitton T.G., et al. Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am 2011, 36(1):3-9.
    • (2011) J Hand Surg Am , vol.36 , Issue.1 , pp. 3-9
    • Soong, M.1    van Leerdam, R.2    Guitton, T.G.3
  • 9
    • 34248229716 scopus 로고    scopus 로고
    • Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
    • Arora R., Lutz M., Hennerbichler A., et al. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007, 21(5):316-322.
    • (2007) J Orthop Trauma , vol.21 , Issue.5 , pp. 316-322
    • Arora, R.1    Lutz, M.2    Hennerbichler, A.3
  • 10
    • 70149109412 scopus 로고    scopus 로고
    • Complications of volar plate fixation for managing distal radius fractures
    • Berglund L.M., Messer T.M. Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg 2009, 17(6):369-377.
    • (2009) J Am Acad Orthop Surg , vol.17 , Issue.6 , pp. 369-377
    • Berglund, L.M.1    Messer, T.M.2
  • 11
    • 33749446244 scopus 로고    scopus 로고
    • Two potential causes of EPL rupture after distal radius volar plate fixation
    • Benson E.C., DeCarvalho A., Mikola E.A., et al. Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 2006, 451:218-222.
    • (2006) Clin Orthop Relat Res , vol.451 , pp. 218-222
    • Benson, E.C.1    DeCarvalho, A.2    Mikola, E.A.3
  • 12
    • 58749103204 scopus 로고    scopus 로고
    • Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: a cadaveric study
    • Thomas A.D., Greenberg J.A. Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: a cadaveric study. J Hand Surg Am 2009, 34(2):258-261.
    • (2009) J Hand Surg Am , vol.34 , Issue.2 , pp. 258-261
    • Thomas, A.D.1    Greenberg, J.A.2
  • 13
    • 77952267492 scopus 로고    scopus 로고
    • Re: Pichler et al. Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur. 2009, 34: 598-602
    • Jacob J., Clay N.R. Re: Pichler et al. Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur. 2009, 34: 598-602. J Hand Surg Eur Vol 2010, 35(4):335-336.
    • (2010) J Hand Surg Eur Vol , vol.35 , Issue.4 , pp. 335-336
    • Jacob, J.1    Clay, N.R.2
  • 14
    • 80053562284 scopus 로고    scopus 로고
    • The dorsal horizon view: detecting screw protrusion at the distal radius
    • Joseph S.J., Harvey J.N. The dorsal horizon view: detecting screw protrusion at the distal radius. J Hand Surg Am 2011, 36(10):1691-1693.
    • (2011) J Hand Surg Am , vol.36 , Issue.10 , pp. 1691-1693
    • Joseph, S.J.1    Harvey, J.N.2
  • 15
    • 84860488463 scopus 로고    scopus 로고
    • Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation
    • [Epub ahead of print]
    • Riddick A.P., Hickey B., White S.P. Accuracy of the skyline view for detecting dorsal cortical penetration during volar distal radius fixation. J Hand Surg Eur 2011, [Epub ahead of print].
    • (2011) J Hand Surg Eur
    • Riddick, A.P.1    Hickey, B.2    White, S.P.3
  • 16
    • 34547581677 scopus 로고    scopus 로고
    • Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study
    • Maschke S.D., Evans P.J., Schub D., et al. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand (N Y) 2007, 2(3):144-150.
    • (2007) Hand (N Y) , vol.2 , Issue.3 , pp. 144-150
    • Maschke, S.D.1    Evans, P.J.2    Schub, D.3
  • 17
    • 0028152719 scopus 로고
    • Extensor indicis proprius transfer for loss of extensor pollicis longus function
    • Noorda R.J., Hage J.J. Extensor indicis proprius transfer for loss of extensor pollicis longus function. Arch Orthop Trauma Surg 1994, 113(6):327-329.
    • (1994) Arch Orthop Trauma Surg , vol.113 , Issue.6 , pp. 327-329
    • Noorda, R.J.1    Hage, J.J.2
  • 18
    • 0032967863 scopus 로고    scopus 로고
    • Evaluation of restoration of extensor pollicis function by transfer of the extensor indicis
    • Lemmen M.H., Schreuders T.A., Stam H.J., et al. Evaluation of restoration of extensor pollicis function by transfer of the extensor indicis. J Hand Surg Br 1999, 24(1):46-49.
    • (1999) J Hand Surg Br , vol.24 , Issue.1 , pp. 46-49
    • Lemmen, M.H.1    Schreuders, T.A.2    Stam, H.J.3
  • 19
    • 33847082876 scopus 로고    scopus 로고
    • Extensor indicis-transfer compared with palmaris longus transplantation in reconstruction of extensor pollicis longus tendon: a retrospective study
    • Schaller P., Baer W., Carl H.D. Extensor indicis-transfer compared with palmaris longus transplantation in reconstruction of extensor pollicis longus tendon: a retrospective study. Scand J Plast Reconstr Surg Hand Surg 2007, 41(1):33-35.
    • (2007) Scand J Plast Reconstr Surg Hand Surg , vol.41 , Issue.1 , pp. 33-35
    • Schaller, P.1    Baer, W.2    Carl, H.D.3
  • 20
    • 39149097204 scopus 로고    scopus 로고
    • Flexor tendon injuries following locked volar plating of distal radius fractures
    • Cross A.W., Schmidt C.C. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 2008, 33(2):164-167.
    • (2008) J Hand Surg Am , vol.33 , Issue.2 , pp. 164-167
    • Cross, A.W.1    Schmidt, C.C.2
  • 21
    • 69049095148 scopus 로고    scopus 로고
    • Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius
    • Casaletto J.A., Machin D., Leung R., et al. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur Vol 2009, 34(4):471-474.
    • (2009) J Hand Surg Eur Vol , vol.34 , Issue.4 , pp. 471-474
    • Casaletto, J.A.1    Machin, D.2    Leung, R.3
  • 22
    • 72449165501 scopus 로고    scopus 로고
    • Flexor tendon problems after volar plate fixation of distal radius fractures
    • Adham M.N., Porembski M., Adham C. Flexor tendon problems after volar plate fixation of distal radius fractures. Hand (N Y) 2009, 4(4):406-409.
    • (2009) Hand (N Y) , vol.4 , Issue.4 , pp. 406-409
    • Adham, M.N.1    Porembski, M.2    Adham, C.3
  • 23
    • 0038651175 scopus 로고    scopus 로고
    • Osteosynthesis of distal radial fractures with a volar locking screw plate system
    • Drobetz H., Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 2003, 27(1):1-6.
    • (2003) Int Orthop , vol.27 , Issue.1 , pp. 1-6
    • Drobetz, H.1    Kutscha-Lissberg, E.2
  • 24
    • 38949184263 scopus 로고    scopus 로고
    • Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures. A report of three cases
    • Bhattacharyya T., Wadgaonkar A.D. Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures. A report of three cases. J Bone Joint Surg Am 2008, 90(2):401-403.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.2 , pp. 401-403
    • Bhattacharyya, T.1    Wadgaonkar, A.D.2
  • 25
    • 80055037456 scopus 로고    scopus 로고
    • Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge
    • Tanaka Y., Aoki M., Izumi T., et al. Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge. J Hand Surg Am 2011, 36(11):1790-1797.
    • (2011) J Hand Surg Am , vol.36 , Issue.11 , pp. 1790-1797
    • Tanaka, Y.1    Aoki, M.2    Izumi, T.3
  • 26
    • 33646840103 scopus 로고    scopus 로고
    • Current concepts in volar fixed-angle fixation of unstable distal radius fractures
    • Orbay J.L., Touhami A. Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 2006, 445:58-67.
    • (2006) Clin Orthop Relat Res , vol.445 , pp. 58-67
    • Orbay, J.L.1    Touhami, A.2
  • 27
    • 79951932617 scopus 로고    scopus 로고
    • Volar locking plate implant prominence and flexor tendon rupture
    • Soong M., Earp B.E., Bishop G., et al. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am 2011, 93(4):328-335.
    • (2011) J Bone Joint Surg Am , vol.93 , Issue.4 , pp. 328-335
    • Soong, M.1    Earp, B.E.2    Bishop, G.3
  • 28
    • 84858392521 scopus 로고    scopus 로고
    • Prevention of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures
    • Tada K., Ikeda K., Shigemoto K., et al. Prevention of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures. Hand Surg 2011, 16(3):271-275.
    • (2011) Hand Surg , vol.16 , Issue.3 , pp. 271-275
    • Tada, K.1    Ikeda, K.2    Shigemoto, K.3
  • 29
    • 0034578071 scopus 로고    scopus 로고
    • The treatment of unstable distal radius fractures with volar fixation
    • Orbay J.L. The treatment of unstable distal radius fractures with volar fixation. Hand Surg 2000, 5(2):103-112.
    • (2000) Hand Surg , vol.5 , Issue.2 , pp. 103-112
    • Orbay, J.L.1
  • 30
    • 84860463730 scopus 로고    scopus 로고
    • Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture: pronator quadratus plate coverage may not adequately protect tendons
    • Brown E.N., Lifchez S.D. Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture: pronator quadratus plate coverage may not adequately protect tendons. Eplasty 2011, 11:e43.
    • (2011) Eplasty , vol.11
    • Brown, E.N.1    Lifchez, S.D.2
  • 31
    • 79958054537 scopus 로고    scopus 로고
    • Removal of locked volar plates after distal radius fractures
    • Gyuricza C., Carlson M.G., Weiland A.J., et al. Removal of locked volar plates after distal radius fractures. J Hand Surg Am 2011, 36(6):982-985.
    • (2011) J Hand Surg Am , vol.36 , Issue.6 , pp. 982-985
    • Gyuricza, C.1    Carlson, M.G.2    Weiland, A.J.3
  • 32
    • 0021018067 scopus 로고
    • Flexor superficialis tendon transfers to the thumb-an alternative to the free tendon graft for treatment of chronic injuries within the digital sheath
    • Posner M.A. Flexor superficialis tendon transfers to the thumb-an alternative to the free tendon graft for treatment of chronic injuries within the digital sheath. J Hand Surg Am 1983, 8(6):876-881.
    • (1983) J Hand Surg Am , vol.8 , Issue.6 , pp. 876-881
    • Posner, M.A.1
  • 33
    • 0020687484 scopus 로고
    • Restoration of flexor pollicis longus function by flexor digitorum superficialis transfer
    • Schneider L.H., Wiltshire D. Restoration of flexor pollicis longus function by flexor digitorum superficialis transfer. J Hand Surg Am 1983, 8(1):98-101.
    • (1983) J Hand Surg Am , vol.8 , Issue.1 , pp. 98-101
    • Schneider, L.H.1    Wiltshire, D.2
  • 34
    • 34548487815 scopus 로고    scopus 로고
    • Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report
    • Klug R.A., Press C.M., Gonzalez M.H. Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report. J Hand Surg Am 2007, 32(7):984-988.
    • (2007) J Hand Surg Am , vol.32 , Issue.7 , pp. 984-988
    • Klug, R.A.1    Press, C.M.2    Gonzalez, M.H.3
  • 36
    • 20944431776 scopus 로고    scopus 로고
    • Fragment-specific fixation of distal radius fractures using the Trimed device
    • Schumer E.D., Leslie B.M. Fragment-specific fixation of distal radius fractures using the Trimed device. Tech Hand Up Extrem Surg 2005, 9(2):74-83.
    • (2005) Tech Hand Up Extrem Surg , vol.9 , Issue.2 , pp. 74-83
    • Schumer, E.D.1    Leslie, B.M.2
  • 37
    • 0036130725 scopus 로고    scopus 로고
    • Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report
    • Orbay J.L., Fernandez D.L. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 2002, 27(2):205-215.
    • (2002) J Hand Surg Am , vol.27 , Issue.2 , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2
  • 38
    • 0742270693 scopus 로고    scopus 로고
    • Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient
    • Orbay J.L., Fernandez D.L. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 2004, 29(1):96-102.
    • (2004) J Hand Surg Am , vol.29 , Issue.1 , pp. 96-102
    • Orbay, J.L.1    Fernandez, D.L.2
  • 39
    • 77952707717 scopus 로고    scopus 로고
    • Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study
    • Mehling I., Muller L.P., Delinsky K., et al. Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg Am 2010, 35(6):885-891.
    • (2010) J Hand Surg Am , vol.35 , Issue.6 , pp. 885-891
    • Mehling, I.1    Muller, L.P.2    Delinsky, K.3
  • 40
    • 72449205194 scopus 로고    scopus 로고
    • Influence of an additional locking screw on fracture reduction after volar fixed-angle plating-introduction of the "protection screw" in an extra-articular distal radius fracture model
    • Weninger P., Schueller M., Drobetz H., et al. Influence of an additional locking screw on fracture reduction after volar fixed-angle plating-introduction of the "protection screw" in an extra-articular distal radius fracture model. J Trauma 2009, 67(4):746-751.
    • (2009) J Trauma , vol.67 , Issue.4 , pp. 746-751
    • Weninger, P.1    Schueller, M.2    Drobetz, H.3
  • 41
    • 78549295173 scopus 로고    scopus 로고
    • Volar fixed-angle plating of extra-articular distal radius fractures-a biomechanical analysis comparing threaded screws and smooth pegs
    • Weninger P., Dall'Ara E., Leixnering M., et al. Volar fixed-angle plating of extra-articular distal radius fractures-a biomechanical analysis comparing threaded screws and smooth pegs. J Trauma 2010, 69(5):E46-E55.
    • (2010) J Trauma , vol.69 , Issue.5
    • Weninger, P.1    Dall'Ara, E.2    Leixnering, M.3
  • 42
    • 0025987859 scopus 로고
    • Ligamentotaxis for comminuted distal radial fractures modified by primary cancellous grafting and functional bracing: long-term results
    • Leung K.S., So W.S., Chiu V.D., et al. Ligamentotaxis for comminuted distal radial fractures modified by primary cancellous grafting and functional bracing: long-term results. J Orthop Trauma 1991, 5(3):265-271.
    • (1991) J Orthop Trauma , vol.5 , Issue.3 , pp. 265-271
    • Leung, K.S.1    So, W.S.2    Chiu, V.D.3
  • 43
    • 0024437626 scopus 로고
    • Ligamentotaxis and bone grafting for comminuted fractures of the distal radius
    • Leung K.S., Shen W.Y., Leung P.C., et al. Ligamentotaxis and bone grafting for comminuted fractures of the distal radius. J Bone Joint Surg Br 1989, 71(5):838-842.
    • (1989) J Bone Joint Surg Br , vol.71 , Issue.5 , pp. 838-842
    • Leung, K.S.1    Shen, W.Y.2    Leung, P.C.3
  • 44
    • 44949083508 scopus 로고    scopus 로고
    • Bone grafts and bone substitutes for treating distal radial fractures in adults
    • CD006836
    • Handoll H.H., Watts A.C. Bone grafts and bone substitutes for treating distal radial fractures in adults. Cochrane Database Syst Rev 2008, 2. CD006836.
    • (2008) Cochrane Database Syst Rev , vol.2
    • Handoll, H.H.1    Watts, A.C.2
  • 45
    • 79956196529 scopus 로고    scopus 로고
    • The use of beta-tricalcium phosphate bone graft substitute in dorsally plated, comminuted distal radius fractures
    • Jakubietz M.G., Gruenert J.G., Jakubietz R.G. The use of beta-tricalcium phosphate bone graft substitute in dorsally plated, comminuted distal radius fractures. J Orthop Surg Res 2011, 6:24.
    • (2011) J Orthop Surg Res , vol.6 , pp. 24
    • Jakubietz, M.G.1    Gruenert, J.G.2    Jakubietz, R.G.3
  • 46
    • 50249099846 scopus 로고    scopus 로고
    • Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit
    • Buzzell J.E., Weikert D.R., Watson J.T., et al. Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am 2008, 33(7):1144-1152.
    • (2008) J Hand Surg Am , vol.33 , Issue.7 , pp. 1144-1152
    • Buzzell, J.E.1    Weikert, D.R.2    Watson, J.T.3
  • 47
    • 22544455333 scopus 로고    scopus 로고
    • Combined internal and external fixation of distal radius fractures
    • McAuliffe J.A. Combined internal and external fixation of distal radius fractures. Hand Clin 2005, 21(3):395-406.
    • (2005) Hand Clin , vol.21 , Issue.3 , pp. 395-406
    • McAuliffe, J.A.1
  • 48
    • 18144386939 scopus 로고    scopus 로고
    • Use of a distraction plate for distal radial fractures with metaphyseal and diaphyseal comminution
    • Ruch D.S., Ginn T.A., Yang C.C., et al. Use of a distraction plate for distal radial fractures with metaphyseal and diaphyseal comminution. J Bone Joint Surg Am 2005, 87(5):945-954.
    • (2005) J Bone Joint Surg Am , vol.87 , Issue.5 , pp. 945-954
    • Ruch, D.S.1    Ginn, T.A.2    Yang, C.C.3
  • 49
    • 0033019593 scopus 로고    scopus 로고
    • Tilted lateral radiographs in the evaluation of intra-articular distal radius fractures
    • Lundy D.W., Quisling S.G., Lourie G.M., et al. Tilted lateral radiographs in the evaluation of intra-articular distal radius fractures. J Hand Surg Am 1999, 24(2):249-256.
    • (1999) J Hand Surg Am , vol.24 , Issue.2 , pp. 249-256
    • Lundy, D.W.1    Quisling, S.G.2    Lourie, G.M.3
  • 50
    • 0742288127 scopus 로고    scopus 로고
    • Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation
    • Boyer M.I., Korcek K.J., Gelberman R.H., et al. Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation. J Hand Surg Am 2004, 29(1):116-122.
    • (2004) J Hand Surg Am , vol.29 , Issue.1 , pp. 116-122
    • Boyer, M.I.1    Korcek, K.J.2    Gelberman, R.H.3
  • 51
    • 77952744019 scopus 로고    scopus 로고
    • Lateral tilt wrist radiograph using the contralateral hand to position the wrist after volar plating of distal radius fractures
    • Matullo K.S., Dennison D.G. Lateral tilt wrist radiograph using the contralateral hand to position the wrist after volar plating of distal radius fractures. J Hand Surg Am 2010, 35(6):900-904.
    • (2010) J Hand Surg Am , vol.35 , Issue.6 , pp. 900-904
    • Matullo, K.S.1    Dennison, D.G.2
  • 52
    • 0035695437 scopus 로고    scopus 로고
    • Tangential views of the articular surface of the distal radius-aid to open reduction and internal fixation of fractures
    • Kumar D., Breakwell L., Deshmukh S.C., et al. Tangential views of the articular surface of the distal radius-aid to open reduction and internal fixation of fractures. Injury 2001, 32(10):783-786.
    • (2001) Injury , vol.32 , Issue.10 , pp. 783-786
    • Kumar, D.1    Breakwell, L.2    Deshmukh, S.C.3
  • 53
    • 33750631979 scopus 로고    scopus 로고
    • Arthroscopic management of distal radius fractures
    • Wiesler E.R., Chloros G.D., Mahirogullari M., et al. Arthroscopic management of distal radius fractures. J Hand Surg Am 2006, 31(9):1516-1526.
    • (2006) J Hand Surg Am , vol.31 , Issue.9 , pp. 1516-1526
    • Wiesler, E.R.1    Chloros, G.D.2    Mahirogullari, M.3
  • 54
    • 4544359393 scopus 로고    scopus 로고
    • Loss of fixation of the volar lunate facet fragment in fractures of the distal part of the radius
    • Harness N.G., Jupiter J.B., Orbay J.L., et al. Loss of fixation of the volar lunate facet fragment in fractures of the distal part of the radius. J Bone Joint Surg Am 2004, 86(9):1900-1908.
    • (2004) J Bone Joint Surg Am , vol.86 , Issue.9 , pp. 1900-1908
    • Harness, N.G.1    Jupiter, J.B.2    Orbay, J.L.3
  • 55
    • 84855851845 scopus 로고    scopus 로고
    • The effects of a displaced dorsal rim fracture on outcomes after volar plate fixation of a distal radius fracture
    • Kim J.K., Cho S.W. The effects of a displaced dorsal rim fracture on outcomes after volar plate fixation of a distal radius fracture. Injury 2012, 43(2):143-146.
    • (2012) Injury , vol.43 , Issue.2 , pp. 143-146
    • Kim, J.K.1    Cho, S.W.2
  • 56
    • 0032935566 scopus 로고    scopus 로고
    • Wire-loop fixation of volar displaced osteochondral fractures of the distal radius
    • Chin K.R., Jupiter J.B. Wire-loop fixation of volar displaced osteochondral fractures of the distal radius. J Hand Surg Am 1999, 24(3):525-533.
    • (1999) J Hand Surg Am , vol.24 , Issue.3 , pp. 525-533
    • Chin, K.R.1    Jupiter, J.B.2
  • 57
    • 0024194380 scopus 로고
    • Open reduction and internal fixation of volar lip fractures of the distal radius
    • Smith R.S., Crick J.C., Alonso J., et al. Open reduction and internal fixation of volar lip fractures of the distal radius. J Orthop Trauma 1988, 2(3):181-187.
    • (1988) J Orthop Trauma , vol.2 , Issue.3 , pp. 181-187
    • Smith, R.S.1    Crick, J.C.2    Alonso, J.3
  • 58
    • 33846624729 scopus 로고    scopus 로고
    • Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model
    • Grindel S.I., Wang M., Gerlach M., et al. Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model. J Hand Surg Am 2007, 32(2):194-199.
    • (2007) J Hand Surg Am , vol.32 , Issue.2 , pp. 194-199
    • Grindel, S.I.1    Wang, M.2    Gerlach, M.3
  • 59
    • 57149137888 scopus 로고    scopus 로고
    • Fluoroscopic evaluation of intra-articular screw placement during locked volar plating of the distal radius: a cadaveric study
    • Soong M., Got C., Katarincic J., et al. Fluoroscopic evaluation of intra-articular screw placement during locked volar plating of the distal radius: a cadaveric study. J Hand Surg Am 2008, 33(10):1720-1723.
    • (2008) J Hand Surg Am , vol.33 , Issue.10 , pp. 1720-1723
    • Soong, M.1    Got, C.2    Katarincic, J.3
  • 60
    • 7444263390 scopus 로고    scopus 로고
    • The 45 degrees pronated oblique view for volar fixed-angle plating of distal radius fractures
    • Smith D.W., Henry M.H. The 45 degrees pronated oblique view for volar fixed-angle plating of distal radius fractures. J Hand Surg Am 2004, 29(4):703-706.
    • (2004) J Hand Surg Am , vol.29 , Issue.4 , pp. 703-706
    • Smith, D.W.1    Henry, M.H.2
  • 61
    • 77949918204 scopus 로고    scopus 로고
    • Rotational fluoroscopy assists in detection of intra-articular screw penetration during volar plating of the distal radius
    • Tweet M.L., Calfee R.P., Stern P.J. Rotational fluoroscopy assists in detection of intra-articular screw penetration during volar plating of the distal radius. J Hand Surg Am 2010, 35(4):619-627.
    • (2010) J Hand Surg Am , vol.35 , Issue.4 , pp. 619-627
    • Tweet, M.L.1    Calfee, R.P.2    Stern, P.J.3
  • 62
    • 33847127052 scopus 로고    scopus 로고
    • Ulnar nerve palsy associated with fracture of the distal radius
    • Soong M., Ring D. Ulnar nerve palsy associated with fracture of the distal radius. J Orthop Trauma 2007, 21(2):113-116.
    • (2007) J Orthop Trauma , vol.21 , Issue.2 , pp. 113-116
    • Soong, M.1    Ring, D.2
  • 63
    • 0242336574 scopus 로고    scopus 로고
    • Fixation of distal radius fractures using AO titanium volar distal radius plate
    • Lee H.C., Wong Y.S., Chan B.K., et al. Fixation of distal radius fractures using AO titanium volar distal radius plate. Hand Surg 2003, 8(1):7-15.
    • (2003) Hand Surg , vol.8 , Issue.1 , pp. 7-15
    • Lee, H.C.1    Wong, Y.S.2    Chan, B.K.3
  • 64
    • 79951768784 scopus 로고    scopus 로고
    • Hand numbness and carpal tunnel syndrome after volar plating of distal radius fracture
    • Ho A.W., Ho S.T., Koo S.C., et al. Hand numbness and carpal tunnel syndrome after volar plating of distal radius fracture. Hand (N Y) 2011, 6(1):34-38.
    • (2011) Hand (N Y) , vol.6 , Issue.1 , pp. 34-38
    • Ho, A.W.1    Ho, S.T.2    Koo, S.C.3
  • 65
    • 53249119641 scopus 로고    scopus 로고
    • Predictors of acute carpal tunnel syndrome associated with fracture of the distal radius
    • Dyer G., Lozano-Calderon S., Gannon C., et al. Predictors of acute carpal tunnel syndrome associated with fracture of the distal radius. J Hand Surg Am 2008, 33(8):1309-1313.
    • (2008) J Hand Surg Am , vol.33 , Issue.8 , pp. 1309-1313
    • Dyer, G.1    Lozano-Calderon, S.2    Gannon, C.3
  • 66
    • 50249168302 scopus 로고    scopus 로고
    • A prospective plan to minimise median nerve related complications associated with operatively treated distal radius fractures
    • Henry M., Stutz C. A prospective plan to minimise median nerve related complications associated with operatively treated distal radius fractures. Hand Surg 2007, 12(3):199-204.
    • (2007) Hand Surg , vol.12 , Issue.3 , pp. 199-204
    • Henry, M.1    Stutz, C.2
  • 67
    • 0034886935 scopus 로고    scopus 로고
    • Prophylactic carpal tunnel decompression during buttress plating of the distal radius-is it justified?
    • Odumala O., Ayekoloye C., Packer G. Prophylactic carpal tunnel decompression during buttress plating of the distal radius-is it justified?. Injury 2001, 32(7):577-579.
    • (2001) Injury , vol.32 , Issue.7 , pp. 577-579
    • Odumala, O.1    Ayekoloye, C.2    Packer, G.3
  • 68
    • 50249083999 scopus 로고    scopus 로고
    • Comparison of 2 surgical approaches for volar locking plate osteosynthesis of the distal radius
    • Lattmann T., Dietrich M., Meier C., et al. Comparison of 2 surgical approaches for volar locking plate osteosynthesis of the distal radius. J Hand Surg Am 2008, 33(7):1135-1143.
    • (2008) J Hand Surg Am , vol.33 , Issue.7 , pp. 1135-1143
    • Lattmann, T.1    Dietrich, M.2    Meier, C.3
  • 70
    • 78649914457 scopus 로고    scopus 로고
    • Median nerve fibrosis at the distal forearm after volar plate fixation of distal radius fracture
    • Nourbakhsh A., Tan V. Median nerve fibrosis at the distal forearm after volar plate fixation of distal radius fracture. J Hand Surg Eur Vol 2010, 35(9):768-769.
    • (2010) J Hand Surg Eur Vol , vol.35 , Issue.9 , pp. 768-769
    • Nourbakhsh, A.1    Tan, V.2
  • 71
    • 77954680591 scopus 로고    scopus 로고
    • Complications of distal radius fracture fixation
    • Patel V.P., Paksima N. Complications of distal radius fracture fixation. Bull NYU Hosp Jt Dis 2010, 68(2):112-118.
    • (2010) Bull NYU Hosp Jt Dis , vol.68 , Issue.2 , pp. 112-118
    • Patel, V.P.1    Paksima, N.2
  • 72
    • 71549135212 scopus 로고    scopus 로고
    • Complications of distal radius fractures
    • Turner R.G., Faber K.J., Athwal G.S. Complications of distal radius fractures. Hand Clin 2010, 26(1):85-96.
    • (2010) Hand Clin , vol.26 , Issue.1 , pp. 85-96
    • Turner, R.G.1    Faber, K.J.2    Athwal, G.S.3
  • 73
    • 0021167387 scopus 로고
    • Carpal tunnel pressures and wrist position in patients with Colles' fractures
    • Gelberman R.H., Szabo R.M., Mortensen W.W. Carpal tunnel pressures and wrist position in patients with Colles' fractures. J Trauma 1984, 24(8):747-749.
    • (1984) J Trauma , vol.24 , Issue.8 , pp. 747-749
    • Gelberman, R.H.1    Szabo, R.M.2    Mortensen, W.W.3
  • 74
    • 77954044433 scopus 로고    scopus 로고
    • Volar plate osteosynthesis of distal radius fractures with concurrent prophylactic carpal tunnel release using a hybrid flexor carpi radialis approach
    • Gwathmey F.W., Brunton L.M., Pensy R.A., et al. Volar plate osteosynthesis of distal radius fractures with concurrent prophylactic carpal tunnel release using a hybrid flexor carpi radialis approach. J Hand Surg Am 2010, 35(7):1082-1088.e4.
    • (2010) J Hand Surg Am , vol.35 , Issue.7
    • Gwathmey, F.W.1    Brunton, L.M.2    Pensy, R.A.3
  • 75
    • 0035210792 scopus 로고    scopus 로고
    • The extended flexor carpi radialis approach: a new perspective for the distal radius fracture
    • Orbay J.L., Badia A., Indriago I.R., et al. The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Up Extrem Surg 2001, 5(4):204-211.
    • (2001) Tech Hand Up Extrem Surg , vol.5 , Issue.4 , pp. 204-211
    • Orbay, J.L.1    Badia, A.2    Indriago, I.R.3
  • 76
    • 0031684372 scopus 로고    scopus 로고
    • Acute carpal tunnel syndrome
    • ix
    • Szabo R.M. Acute carpal tunnel syndrome. Hand Clin 1998, 14(3):419-429. ix.
    • (1998) Hand Clin , vol.14 , Issue.3 , pp. 419-429
    • Szabo, R.M.1
  • 77
    • 0030936641 scopus 로고    scopus 로고
    • Flexor carpi radialis approach for carpal tunnel release
    • Weber R.A., Sanders W.E. Flexor carpi radialis approach for carpal tunnel release. J Hand Surg Am 1997, 22(1):120-126.
    • (1997) J Hand Surg Am , vol.22 , Issue.1 , pp. 120-126
    • Weber, R.A.1    Sanders, W.E.2
  • 78
    • 75149176669 scopus 로고    scopus 로고
    • Single-incision extensile volar approach to the distal radius and concurrent carpal tunnel release: cadaveric study
    • Pensy R.A., Brunton L.M., Parks B.G., et al. Single-incision extensile volar approach to the distal radius and concurrent carpal tunnel release: cadaveric study. J Hand Surg Am 2010, 35(2):217-222.
    • (2010) J Hand Surg Am , vol.35 , Issue.2 , pp. 217-222
    • Pensy, R.A.1    Brunton, L.M.2    Parks, B.G.3
  • 79
    • 80052132716 scopus 로고    scopus 로고
    • Percutaneous pinning for non-comminuted extra-articular fractures of distal radius
    • Das A.K., Sundaram N., Prasad T.G., et al. Percutaneous pinning for non-comminuted extra-articular fractures of distal radius. Indian J Orthop 2011, 45(5):422-426.
    • (2011) Indian J Orthop , vol.45 , Issue.5 , pp. 422-426
    • Das, A.K.1    Sundaram, N.2    Prasad, T.G.3
  • 80
    • 12344290443 scopus 로고    scopus 로고
    • Superficial radial nerve damage due to Kirschner wiring of the radius
    • Singh S., Trikha P., Twyman R. Superficial radial nerve damage due to Kirschner wiring of the radius. Injury 2005, 36(2):330-332.
    • (2005) Injury , vol.36 , Issue.2 , pp. 330-332
    • Singh, S.1    Trikha, P.2    Twyman, R.3
  • 81
    • 67651008618 scopus 로고    scopus 로고
    • Percutaneous pinning of distal radius fractures: an anatomic study demonstrating the proximity of K-wires to structures at risk
    • Chia B., Catalano L.W.3rd, Glickel S.Z., et al. Percutaneous pinning of distal radius fractures: an anatomic study demonstrating the proximity of K-wires to structures at risk. J Hand Surg Am 2009, 34(6):1014-1020.
    • (2009) J Hand Surg Am , vol.34 , Issue.6 , pp. 1014-1020
    • Chia, B.1    Catalano, L.W.3.2    Glickel, S.Z.3
  • 82
    • 0028870063 scopus 로고
    • Percutaneous Kirschner wire fixation through the snuff box: an anatomic study
    • Steinberg B.D., Plancher K.D., Idler R.S. Percutaneous Kirschner wire fixation through the snuff box: an anatomic study. J Hand Surg Am 1995, 20(1):57-62.
    • (1995) J Hand Surg Am , vol.20 , Issue.1 , pp. 57-62
    • Steinberg, B.D.1    Plancher, K.D.2    Idler, R.S.3
  • 83
    • 80054794485 scopus 로고    scopus 로고
    • Evaluation of the safe zone for percutaneous Kirschner-wire placement in the distal radius: cadaveric study
    • Korcek L., Wongworawat M. Evaluation of the safe zone for percutaneous Kirschner-wire placement in the distal radius: cadaveric study. Clin Anat 2011, 24(8):1005-1009.
    • (2011) Clin Anat , vol.24 , Issue.8 , pp. 1005-1009
    • Korcek, L.1    Wongworawat, M.2
  • 84
    • 0032833570 scopus 로고    scopus 로고
    • Safety of the limited open technique of bone-transfixing threaded-pin placement for external fixation of distal radial fractures: a cadaver study
    • Hassan D.M., Johnston G.H. Safety of the limited open technique of bone-transfixing threaded-pin placement for external fixation of distal radial fractures: a cadaver study. Can J Surg 1999, 42(5):363-365.
    • (1999) Can J Surg , vol.42 , Issue.5 , pp. 363-365
    • Hassan, D.M.1    Johnston, G.H.2
  • 85
    • 0033739451 scopus 로고    scopus 로고
    • A safer pin position for external fixation of distal radial fractures
    • Emami A., Mjoberg B. A safer pin position for external fixation of distal radial fractures. Injury 2000, 31(9):749-750.
    • (2000) Injury , vol.31 , Issue.9 , pp. 749-750
    • Emami, A.1    Mjoberg, B.2
  • 86
    • 34250809697 scopus 로고    scopus 로고
    • Open reduction and internal locked fixation of unstable distal ulna fractures with concomitant distal radius fracture
    • Dennison D.G. Open reduction and internal locked fixation of unstable distal ulna fractures with concomitant distal radius fracture. J Hand Surg Am 2007, 32(6):801-805.
    • (2007) J Hand Surg Am , vol.32 , Issue.6 , pp. 801-805
    • Dennison, D.G.1
  • 87
    • 79952200088 scopus 로고    scopus 로고
    • The anatomy of the dorsal cutaneous branch of the ulnar nerve
    • Puna R., Poon P. The anatomy of the dorsal cutaneous branch of the ulnar nerve. J Hand Surg Eur Vol 2010, 35(7):583-585.
    • (2010) J Hand Surg Eur Vol , vol.35 , Issue.7 , pp. 583-585
    • Puna, R.1    Poon, P.2
  • 88
    • 0026752892 scopus 로고
    • Features of algodystrophy ten years after Colles' fracture
    • Field J., Warwick D., Bannister G.C. Features of algodystrophy ten years after Colles' fracture. J Hand Surg Br 1992, 17(3):318-320.
    • (1992) J Hand Surg Br , vol.17 , Issue.3 , pp. 318-320
    • Field, J.1    Warwick, D.2    Bannister, G.C.3
  • 89
    • 27744593058 scopus 로고    scopus 로고
    • Complex regional pain syndrome type 1 after fractures of the distal radius: a prospective study of the role of psychological factors
    • Puchalski P., Zyluk A. Complex regional pain syndrome type 1 after fractures of the distal radius: a prospective study of the role of psychological factors. J Hand Surg Br 2005, 30(6):574-580.
    • (2005) J Hand Surg Br , vol.30 , Issue.6 , pp. 574-580
    • Puchalski, P.1    Zyluk, A.2
  • 90
    • 34848833547 scopus 로고    scopus 로고
    • Delayed recovery and late development of complex regional pain syndrome in patients with an isolated fracture of the distal radius: prediction of a regional inflammatory response by early signs
    • Goris R.J., Leixnering M., Huber W., et al. Delayed recovery and late development of complex regional pain syndrome in patients with an isolated fracture of the distal radius: prediction of a regional inflammatory response by early signs. J Bone Joint Surg Br 2007, 89(8):1069-1076.
    • (2007) J Bone Joint Surg Br , vol.89 , Issue.8 , pp. 1069-1076
    • Goris, R.J.1    Leixnering, M.2    Huber, W.3
  • 91
    • 34447279670 scopus 로고    scopus 로고
    • Can vitamin C prevent complex regional pain syndrome in patients with wrist fractures? A randomized, controlled, multicenter dose-response study
    • Zollinger P.E., Tuinebreijer W.E., Breederveld R.S., et al. Can vitamin C prevent complex regional pain syndrome in patients with wrist fractures? A randomized, controlled, multicenter dose-response study. J Bone Joint Surg Am 2007, 89(7):1424-1431.
    • (2007) J Bone Joint Surg Am , vol.89 , Issue.7 , pp. 1424-1431
    • Zollinger, P.E.1    Tuinebreijer, W.E.2    Breederveld, R.S.3
  • 92
    • 0034116834 scopus 로고    scopus 로고
    • Vitamin C reduced the incidence of reflex sympathetic dystrophy after wrist fracture
    • Amadio P.C. Vitamin C reduced the incidence of reflex sympathetic dystrophy after wrist fracture. J Bone Joint Surg Am 2000, 82(6):873.
    • (2000) J Bone Joint Surg Am , vol.82 , Issue.6 , pp. 873
    • Amadio, P.C.1
  • 93
    • 70350532896 scopus 로고    scopus 로고
    • Use of oral vitamin C after fractures of the distal radius
    • Shah A.S., Verma M.K., Jebson P.J. Use of oral vitamin C after fractures of the distal radius. J Hand Surg Am 2009, 34(9):1736-1738.
    • (2009) J Hand Surg Am , vol.34 , Issue.9 , pp. 1736-1738
    • Shah, A.S.1    Verma, M.K.2    Jebson, P.J.3
  • 94
    • 3042856169 scopus 로고    scopus 로고
    • Kirschner wire pin tract infection rates: a randomized controlled trial between percutaneous and buried wires
    • Hargreaves D.G., Drew S.J., Eckersley R. Kirschner wire pin tract infection rates: a randomized controlled trial between percutaneous and buried wires. J Hand Surg Br 2004, 29(4):374-376.
    • (2004) J Hand Surg Br , vol.29 , Issue.4 , pp. 374-376
    • Hargreaves, D.G.1    Drew, S.J.2    Eckersley, R.3
  • 95
    • 0032897234 scopus 로고    scopus 로고
    • Pin-tract complications in external fixation of fractures of the distal radius
    • Ahlborg H.G., Josefsson P.O. Pin-tract complications in external fixation of fractures of the distal radius. Acta Orthop Scand 1999, 70(2):116-118.
    • (1999) Acta Orthop Scand , vol.70 , Issue.2 , pp. 116-118
    • Ahlborg, H.G.1    Josefsson, P.O.2
  • 96
    • 0026582810 scopus 로고
    • Complications of smooth pin fixation of fractures and dislocations in the hand and wrist
    • Botte M.J., Davis J.L., Rose B.A., et al. Complications of smooth pin fixation of fractures and dislocations in the hand and wrist. Clin Orthop Relat Res 1992, (276):194-201.
    • (1992) Clin Orthop Relat Res , Issue.276 , pp. 194-201
    • Botte, M.J.1    Davis, J.L.2    Rose, B.A.3
  • 97
    • 31844453329 scopus 로고    scopus 로고
    • Treatment of external fixation pins about the wrist: a prospective, randomized trial
    • Egol K.A., Paksima N., Puopolo S., et al. Treatment of external fixation pins about the wrist: a prospective, randomized trial. J Bone Joint Surg Am 2006, 88(2):349-354.
    • (2006) J Bone Joint Surg Am , vol.88 , Issue.2 , pp. 349-354
    • Egol, K.A.1    Paksima, N.2    Puopolo, S.3
  • 98
    • 0017076151 scopus 로고
    • Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses
    • Gustilo R.B., Anderson J.T. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses. J Bone Joint Surg Am 1976, 58(4):453-458.
    • (1976) J Bone Joint Surg Am , vol.58 , Issue.4 , pp. 453-458
    • Gustilo, R.B.1    Anderson, J.T.2
  • 100
    • 79959844399 scopus 로고    scopus 로고
    • Open fractures of the distal radius: the effects of delayed debridement and immediate internal fixation on infection rates and the need for secondary procedures
    • Kurylo J.C., Axelrad T.W., Tornetta P., et al. Open fractures of the distal radius: the effects of delayed debridement and immediate internal fixation on infection rates and the need for secondary procedures. J Hand Surg Am 2011, 36(7):1131-1134.
    • (2011) J Hand Surg Am , vol.36 , Issue.7 , pp. 1131-1134
    • Kurylo, J.C.1    Axelrad, T.W.2    Tornetta, P.3
  • 101
    • 68949133040 scopus 로고    scopus 로고
    • Factors associated with infection following open distal radius fractures
    • Glueck D.A., Charoglu C.P., Lawton J.N. Factors associated with infection following open distal radius fractures. Hand (N Y) 2009, 4(3):330-334.
    • (2009) Hand (N Y) , vol.4 , Issue.3 , pp. 330-334
    • Glueck, D.A.1    Charoglu, C.P.2    Lawton, J.N.3
  • 102
    • 77955669280 scopus 로고    scopus 로고
    • Open fractures of the distal radius
    • Jawa A. Open fractures of the distal radius. J Hand Surg Am 2010, 35(8):1348-1350.
    • (2010) J Hand Surg Am , vol.35 , Issue.8 , pp. 1348-1350
    • Jawa, A.1
  • 103
    • 0038174609 scopus 로고    scopus 로고
    • Acute volar and dorsal compartment syndrome after a distal radius fracture: a case report
    • Kupersmith L.M., Weinfeld S.B. Acute volar and dorsal compartment syndrome after a distal radius fracture: a case report. J Orthop Trauma 2003, 17(5):382-386.
    • (2003) J Orthop Trauma , vol.17 , Issue.5 , pp. 382-386
    • Kupersmith, L.M.1    Weinfeld, S.B.2
  • 104
    • 0030888246 scopus 로고    scopus 로고
    • Compartment syndrome of the pronator quadratus: a case report
    • Summerfield S.L., Folberg C.R., Weiss A.P. Compartment syndrome of the pronator quadratus: a case report. J Hand Surg Am 1997, 22(2):266-268.
    • (1997) J Hand Surg Am , vol.22 , Issue.2 , pp. 266-268
    • Summerfield, S.L.1    Folberg, C.R.2    Weiss, A.P.3
  • 106
    • 62549155358 scopus 로고    scopus 로고
    • Compartment syndrome associated with distal radial fracture and ipsilateral elbow injury
    • Hwang R.W., de Witte P.B., Ring D. Compartment syndrome associated with distal radial fracture and ipsilateral elbow injury. J Bone Joint Surg Am 2009, 91(3):642-645.
    • (2009) J Bone Joint Surg Am , vol.91 , Issue.3 , pp. 642-645
    • Hwang, R.W.1    de Witte, P.B.2    Ring, D.3
  • 107
    • 0034777462 scopus 로고    scopus 로고
    • Effects of limb elevation and increased intramuscular pressure on human tibialis anterior muscle blood flow
    • Zhang Q., Styf J., Lindberg L.G. Effects of limb elevation and increased intramuscular pressure on human tibialis anterior muscle blood flow. Eur J Appl Physiol 2001, 85(6):567-571.
    • (2001) Eur J Appl Physiol , vol.85 , Issue.6 , pp. 567-571
    • Zhang, Q.1    Styf, J.2    Lindberg, L.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.