-
2
-
-
33750473404
-
Dorsal (AO/ASIF) Pi-plate Osteosynthesis in the Treatment of Distal Intraarticular Radius Fractures
-
DOI 10.1016/j.jhsb.2006.08.007, PII S0266768106003998
-
A. Suckel, S. Spies, and P. Mnst Dorsal (AO/ASIF) pi-plate osteosynthesis in the treatment of distal intraarticular radius fractures J Hand Surg 31B 2006 673 679 (Pubitemid 44645139)
-
(2006)
Journal of Hand Surgery
, vol.31
, Issue.6
, pp. 673-679
-
-
Suckel, A.1
Spies, S.2
Munst, P.3
-
3
-
-
30644457769
-
Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-plate
-
V. Khanduja, L. Ng, Z. Dannawi, and L. Heras Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate Acta Orthop Belg 71 2005 672 677 (Pubitemid 43088375)
-
(2005)
Acta Orthopaedica Belgica
, vol.71
, Issue.6
, pp. 672-677
-
-
Khanduja, V.1
Ng, L.2
Dannawi, Z.3
Heras, L.4
-
4
-
-
22544478434
-
Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates
-
DOI 10.1016/j.jhsa.2005.03.006, PII S0363502305002327
-
D.S. Musgrave, and R.S. Idler Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates J Hand Surg 30A 2005 743 749 (Pubitemid 41019211)
-
(2005)
Journal of Hand Surgery
, vol.30
, Issue.4
, pp. 743-749
-
-
Musgrave, D.S.1
Idler, R.S.2
-
5
-
-
34248229716
-
Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
-
DOI 10.1097/BOT.0b013e318059b993, PII 0000513120070500000005
-
R. Arora, M. Lutz, A. Hennerbichler, D. Krappinger, D. Espen, and M. Gabl Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate J Orthop Trauma 21 2007 316 322 (Pubitemid 46718027)
-
(2007)
Journal of Orthopaedic Trauma
, vol.21
, Issue.5
, pp. 316-322
-
-
Arora, R.1
Lutz, M.2
Hennerbichler, A.3
Krappinger, D.4
Espen, D.5
Gabl, M.6
-
6
-
-
37549053244
-
Complications of volar plating of distal radius fractures
-
M. Rampoldi, and S. Marsico Complications of volar plating of distal radius fractures Acta Orthop Belg 73 2007 714 719
-
(2007)
Acta Orthop Belg
, vol.73
, pp. 714-719
-
-
Rampoldi, M.1
Marsico, S.2
-
7
-
-
68249089236
-
Technical difficulties in hardware removal in titanium compression plates with locking screws
-
M. Ehlinger, P. Adam, P. Simon, and F. Bonnomet Technical difficulties in hardware removal in titanium compression plates with locking screws Orthop Traumatol Surg Res 95 2009 373 376
-
(2009)
Orthop Traumatol Surg Res
, vol.95
, pp. 373-376
-
-
Ehlinger, M.1
Adam, P.2
Simon, P.3
Bonnomet, F.4
-
8
-
-
56249085217
-
Technical difficulties of removal of locking screw after locking compression plating
-
J.H. Bae, J.K. Oh, C.W. Oh, and C.R. Hur Technical difficulties of removal of locking screw after locking compression plating Arch Orthop Trauma Surg 129 2009 91 95
-
(2009)
Arch Orthop Trauma Surg
, vol.129
, pp. 91-95
-
-
Bae, J.H.1
Oh, J.K.2
Oh, C.W.3
Hur, C.R.4
-
9
-
-
77953154707
-
Technical problems and complications in the removal of the less invasive stabilization system
-
T. Suzuki, W.R. Smith, P.F. Stahel, S.J. Morgan, A.J. Baron, and D.J. Hak Technical problems and complications in the removal of the less invasive stabilization system J Orthop Trauma 24 2010 369 373
-
(2010)
J Orthop Trauma
, vol.24
, pp. 369-373
-
-
Suzuki, T.1
Smith, W.R.2
Stahel, P.F.3
Morgan, S.J.4
Baron, A.J.5
Hak, D.J.6
-
10
-
-
70149109412
-
Complications of volar plate fixation for managing distal radius fractures
-
L.M. Berglund, and T.M. Messer Complications of volar plate fixation for managing distal radius fractures J Am Acad Orthop Surg 17 2009 369 377
-
(2009)
J Am Acad Orthop Surg
, vol.17
, pp. 369-377
-
-
Berglund, L.M.1
Messer, T.M.2
-
11
-
-
39149097204
-
Flexor Tendon Injuries Following Locked Volar Plating of Distal Radius Fractures
-
DOI 10.1016/j.jhsa.2007.11.011, PII S0363502307010337
-
A.W. Cross, and C.C. Schmidt Flexor tendon injuries following locked volar plating of distal radius fractures J Hand Surg 33A 2008 164 167 (Pubitemid 351253734)
-
(2008)
Journal of Hand Surgery
, vol.33
, Issue.2
, pp. 164-167
-
-
Cross, A.W.1
Schmidt, C.C.2
-
12
-
-
0031951657
-
Rupture of flexor pollicis longus tendon: A complication of volar plating of the distal radius
-
J.S. Bell, R. Wollstein, and N.D. Citron Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius J Bone Joint Surg 80B 1998 225 226 (Pubitemid 128472082)
-
(1998)
Journal of Bone and Joint Surgery - Series B
, vol.80
, Issue.SUPPL. 2
, pp. 225-226
-
-
Bell, J.S.P.1
Wollstein, R.2
Citron, N.D.3
-
13
-
-
34548487815
-
Rupture of the Flexor Pollicis Longus Tendon After Volar Fixed-Angle Plating of a Distal Radius Fracture: A Case Report
-
DOI 10.1016/j.jhsa.2007.05.006, PII S0363502307004959
-
R.A. Klug, C.M. Press, and M.H. Gonzalez Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report J Hand Surg 32A 2007 984 988 (Pubitemid 47371184)
-
(2007)
Journal of Hand Surgery
, vol.32
, Issue.7
, pp. 984-988
-
-
Klug, R.A.1
Press, C.M.2
Gonzalez, M.H.3
-
14
-
-
68349146803
-
Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation: A prospective randomized trial
-
T.D. Rozental, P.E. Blazar, O.I. Franko, A.T. Chacko, B.E. Earp, and C.S. Day Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation A prospective randomized trial J Bone Joint Surg 91A 2009 1837 1846
-
(2009)
J Bone Joint Surg
, vol.91
, pp. 1837-1846
-
-
Rozental, T.D.1
Blazar, P.E.2
Franko, O.I.3
Chacko, A.T.4
Earp, B.E.5
Day, C.S.6
|