메뉴 건너뛰기




Volumn 8, Issue 4, 2004, Pages 266-268

Coverage of distal radius internal fixation and wrist fusion devices with AlloDerm

Author keywords

AlloDerm; Distal radius fracture; Dorsal plating; Wrist arthrodesis

Indexed keywords

ARTHRITIS; ARTHRODESIS; ARTICLE; BONE GRAFT; BONE PLATE; BONE SCREW; DEVICE; FRACTURE FIXATION; HUMAN; OSTEOSYNTHESIS; PRIORITY JOURNAL; RADIUS FRACTURE; SURGICAL TECHNIQUE; SUTURING METHOD; SYNOVITIS; TENDON RUPTURE;

EID: 12344260484     PISSN: 10893393     EISSN: None     Source Type: Journal    
DOI: 10.1097/00130911-200412000-00011     Document Type: Article
Times cited : (6)

References (24)
  • 1
    • 0034948987 scopus 로고    scopus 로고
    • Wrist arthrodesis with excision of proximal carpal bones using the AO/ASIF wrist fusion plate and local bone graft
    • Hartigan B, Nagle D, Foley M. Wrist arthrodesis with excision of proximal carpal bones using the AO/ASIF wrist fusion plate and local bone graft. J Hand Surg Br. 2001; 26B:247-251.
    • (2001) J. Hand Surg. Br. , vol.26 B , pp. 247-251
    • Hartigan, B.1    Nagle, D.2    Foley, M.3
  • 2
    • 17944367096 scopus 로고    scopus 로고
    • A wrist arthrodesis with the AO titanium wrist fusion plate: A consectutive series of 42 cases
    • Housian S, Schroder H. A wrist arthrodesis with the AO titanium wrist fusion plate: a consectutive series of 42 cases. J Hand Surg Br. 2001;26B:355-359.
    • (2001) J. Hand Surg. Br. , vol.26 B , pp. 355-359
    • Housian, S.1    Schroder, H.2
  • 3
    • 0028969484 scopus 로고
    • Complications following AO/ASIF wrist arthrodesis
    • Zachary S, Stern P. Complications following AO/ASIF wrist arthrodesis. J Hand Surg Am. 1995;20A:339-344.
    • (1995) J. Hand Surg. Am. , vol.20 A , pp. 339-344
    • Zachary, S.1    Stern, P.2
  • 4
    • 0032467256 scopus 로고    scopus 로고
    • Open reduction and internal fixation of unstable distal radius fractures with a low profile plate: A multicenter study of 73 fractures
    • Carter P, Frederick H, Laseter G. Open reduction and internal fixation of unstable distal radius fractures with a low profile plate: a multicenter study of 73 fractures. J Hand Surg Am. 1998;23A:300-307.
    • (1998) J. Hand Surg. Am. , vol.23 A , pp. 300-307
    • Carter, P.1    Frederick, H.2    Laseter, G.3
  • 5
    • 0038722227 scopus 로고    scopus 로고
    • Dorsal plating for displaced intraarticular fractures of the distal radius
    • Herron M, Faraj A, Craigen M. Dorsal plating for displaced intraarticular fractures of the distal radius. Injury. 2003;34: 497-502.
    • (2003) Injury , vol.34 , pp. 497-502
    • Herron, M.1    Faraj, A.2    Craigen, M.3
  • 6
    • 0032460038 scopus 로고    scopus 로고
    • Complications of the AO/ASIF titanium distal radius plate system in internal fixation of the distal radius: A brief report
    • Kambouroglou G, Axelrod T. Complications of the AO/ASIF titanium distal radius plate system in internal fixation of the distal radius: a brief report. J Hand Surg Am. 1998;23A:737-741.
    • (1998) J. Hand Surg. Am. , vol.23 A , pp. 737-741
    • Kambouroglou, G.1    Axelrod, T.2
  • 7
    • 0141889322 scopus 로고    scopus 로고
    • Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius
    • Rozental T, Beredjiklian P, Bozentka D. Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius. J Bone Joint Surg Am. 2003;85A:1956-1960.
    • (2003) J. Bone Joint Surg. Am. , vol.85 A , pp. 1956-1960
    • Rozental, T.1    Beredjiklian, P.2    Bozentka, D.3
  • 8
    • 0024835736 scopus 로고
    • Rupture of extensor pollicis longus following fixation of distal radius fracture
    • Wong-Chung J, Quinlan W. Rupture of extensor pollicis longus following fixation of distal radius fracture. Injury. 1989;20:375-376.
    • (1989) Injury , vol.20 , pp. 375-376
    • Wong-Chung, J.1    Quinlan, W.2
  • 9
    • 0031951657 scopus 로고    scopus 로고
    • Rupture of the flexor pollicis longus tendon: A complication of volar plating of the distal radius
    • Bell J, Wollstein R, Citron N. Rupture of the flexor pollicis longus tendon: a complication of volar plating of the distal radius. J Bone Joint Surg Br. 1998;80B: 225-226.
    • (1998) J. Bone Joint Surg. Br. , vol.80 B , pp. 225-226
    • Bell, J.1    Wollstein, R.2    Citron, N.3
  • 10
    • 0242336574 scopus 로고    scopus 로고
    • Fixation of distal radius fractures using AO titanium volar distal radius plate
    • Lee H, Wong Y, Chan B, et al. Fixation of distal radius fractures using AO titanium volar distal radius plate. Hand Surg. 2003;8:7-15.
    • (2003) Hand Surg. , vol.8 , pp. 7-15
    • Lee, H.1    Wong, Y.2    Chan, B.3
  • 11
    • 0032720912 scopus 로고    scopus 로고
    • Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius
    • Nunley J, Rowan P. Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius. J Hand Surg Am. 1999;24A:1279-1280.
    • (1999) J. Hand Surg. Am. , vol.24 A , pp. 1279-1280
    • Nunley, J.1    Rowan, P.2
  • 12
    • 0019478449 scopus 로고
    • Arthrodesis of the wrist-complications and their management
    • Clendinin M, Green D. Arthrodesis of the wrist-complications and their management. J Hand Surg Am. 1981;6A: 253-257.
    • (1981) J. Hand Surg. Am. , vol.6 A , pp. 253-257
    • Clendinin, M.1    Green, D.2
  • 15
    • 0019409452 scopus 로고
    • The advantages of titanium alloy over stainless steel plates for internal fixation of fractures in dogs. An experimental study
    • Uhthoff H, Bardos D, Liskova-Kiar M. The advantages of titanium alloy over stainless steel plates for internal fixation of fractures in dogs. An experimental study. J Bone Joint Surg Br. 1981;63B:427-434.
    • (1981) J. Bone Joint Surg. Br. , vol.63 B , pp. 427-434
    • Uhthoff, H.1    Bardos, D.2    Liskova-Kiar, M.3
  • 16
    • 0037209882 scopus 로고    scopus 로고
    • Immuno-inflammatory tissue reaction to stainless steel and titanium plates used for the fixation of long bones
    • Voggenreiter G, Leiting S, Brauer H, et al. Immuno-inflammatory tissue reaction to stainless steel and titanium plates used for the fixation of long bones. Biomaterials. 2003;24: 247-254.
    • (2003) Biomaterials , vol.24 , pp. 247-254
    • Voggenreiter, G.1    Leiting, S.2    Brauer, H.3
  • 17
    • 0034754123 scopus 로고    scopus 로고
    • Tissue engineered skin. Current status in wound healing
    • Bello Y, Falabella A, Eaglstein W. Tissue engineered skin. Current status in wound healing. Am J Dermatol. 2001;3: 305-313.
    • (2001) Am. J. Dermatol. , vol.3 , pp. 305-313
    • Bello, Y.1    Falabella, A.2    Eaglstein, W.3
  • 18
    • 0345269943 scopus 로고    scopus 로고
    • Use of allogenic dermis for radial forearm free flap donor site coverage
    • Wax M, Winslow C, Anderson P. Use of allogenic dermis for radial forearm free flap donor site coverage. J Otolaryngol. 2002;31:341-345.
    • (2002) J. Otolaryngol. , vol.31 , pp. 341-345
    • Wax, M.1    Winslow, C.2    Anderson, P.3
  • 19
    • 0034215445 scopus 로고    scopus 로고
    • Revascularization of acellular human dermis (AlloDerm) in subcutaneous implantation
    • Eppley B. Revascularization of acellular human dermis (AlloDerm) in subcutaneous implantation. J Asthet Surg. 2000;20:291-295.
    • (2000) J. Asthet. Surg. , vol.20 , pp. 291-295
    • Eppley, B.1
  • 20
    • 0035318887 scopus 로고    scopus 로고
    • Evaluation of acellular dermal graft (AlloDerm) sheet for soft tissue augmentation: A 1 year follow-up of clinical observations and histological findings
    • Sclafani A, Romo T 3rd, Jacono A, et al. Evaluation of acellular dermal graft (AlloDerm) sheet for soft tissue augmentation: a 1 year follow-up of clinical observations and histological findings. Arch Facial Plast Surg. 2001;3: 101-103.
    • (2001) Arch. Facial Plast. Surg. , vol.3 , pp. 101-103
    • Sclafani, A.1    Romo III, T.2    Jacono, A.3
  • 21
    • 0033869920 scopus 로고    scopus 로고
    • Both matrix and epidermis contribute to an inhibition of wound contraction
    • Walden J, Garcia H, Hawkins H, et al. Both matrix and epidermis contribute to an inhibition of wound contraction. Surgery. 2000;45:162-166.
    • (2000) Surgery , vol.45 , pp. 162-166
    • Walden, J.1    Garcia, H.2    Hawkins, H.3
  • 22
    • 0031728990 scopus 로고    scopus 로고
    • Augmentation of soft tissue defects with AlloDerm dermal graft
    • Achauer B, Vanderkam V, Celikoz B, et al. Augmentation of soft tissue defects with AlloDerm dermal graft. Ann Plast Surg. 2001;41:503-507.
    • (2001) Ann. Plast. Surg. , vol.41 , pp. 503-507
    • Achauer, B.1    Vanderkam, V.2    Celikoz, B.3
  • 23
    • 0030994750 scopus 로고    scopus 로고
    • Use of a permanent dermal allograft in full thickness burns of the hand and report of three cases
    • Lattari V, Jones L, Varcelotti J, et al. Use of a permanent dermal allograft in full thickness burns of the hand and report of three cases. J Burn Care Rehabil. 1997;18:147-155.
    • (1997) J. Burn Care Rehabil. , vol.18 , pp. 147-155
    • Lattari, V.1    Jones, L.2    Varcelotti, J.3
  • 24
    • 0029053696 scopus 로고
    • Use of an acellular allograft dermal matrix (AlloDerm) in the management of full-thickness burns
    • Wainright D. Use of an acellular allograft dermal matrix (AlloDerm) in the management of full-thickness burns. Burns. 1995;21:243-248.
    • (1995) Burns , vol.21 , pp. 243-248
    • Wainright, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.