메뉴 건너뛰기




Volumn 36, Issue 10, 2011, Pages 1691-1693

The dorsal horizon view: Detecting screw protrusion at the distal radius

Author keywords

dorsal screw protrusion; Radius fracture; volar plate

Indexed keywords

ADULT; ARTICLE; BONE RADIOGRAPHY; BONE SCREW; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; FLUOROSCOPY; FRACTURE FIXATION; HUMAN; IMAGE INTENSIFIER; INTRAOPERATIVE PERIOD; MALE; OSTEOSYNTHESIS; PRIORITY JOURNAL; RADIUS FRACTURE; RETROSPECTIVE STUDY;

EID: 80053562284     PISSN: 03635023     EISSN: 15316564     Source Type: Journal    
DOI: 10.1016/j.jhsa.2011.07.020     Document Type: Article
Times cited : (60)

References (10)
  • 1
    • 0025216870 scopus 로고
    • Clinical and microangiographic studies on rupture of the E.P.L. tendon after distal radial fractures
    • Y. Hirsawa, Y. Katsumi, T. Akiyoshi, K. Tamai, and T. Tokioka Clinical and microangiographic studies on rupture of the E.P.L. tendon after distal radial fractures J Hand Surg 15B 1990 51 57 (Pubitemid 20125498)
    • (1990) Journal of Hand Surgery , vol.15 B , Issue.1 , pp. 51-57
    • Hirasawa, Y.1    Katsumi, Y.2    Akiyoshi, T.3    Tamai, K.4    Tokioka, T.5
  • 2
    • 34248229716 scopus 로고    scopus 로고
    • Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
    • DOI 10.1097/BOT.0b013e318059b993, PII 0000513120070500000005
    • R. Arora, M. Lutz, A. Hennerbichler, D. Krappinger, D. Espen, and M. Gabl Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate J Orthop Trauma 21 2007 316 322 (Pubitemid 46718027)
    • (2007) Journal of Orthopaedic Trauma , vol.21 , Issue.5 , pp. 316-322
    • Arora, R.1    Lutz, M.2    Hennerbichler, A.3    Krappinger, D.4    Espen, D.5    Gabl, M.6
  • 3
    • 0036130725 scopus 로고    scopus 로고
    • Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    • DOI 10.1053/jhsu.2002.32081
    • J.L. Orbay, and D.L. Fernandez Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report J Hand Surg 27A 2002 205 215 (Pubitemid 34241185)
    • (2002) Journal of Hand Surgery , vol.27 , Issue.2 , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2
  • 4
    • 33845734224 scopus 로고    scopus 로고
    • Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures
    • DOI 10.1302/0301-620X.88B12.17696
    • M. Al-Rashid, K. Theivendran, and M.A. Craigen Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures J Bone Joint Surg 88B 2006 1610 1612 (Pubitemid 44970689)
    • (2006) Journal of Bone and Joint Surgery - Series B , vol.88 , Issue.12 , pp. 1610-1612
    • Al-Rashid, M.1    Theivendran, K.2    Craigen, M.A.C.3
  • 5
    • 0027216787 scopus 로고
    • Extensor pollicis longus rupture at the tip of a prominent fixation screw: Report of three cases
    • J.M. Failla, M.P. Koniuch, and B.R. Moed Extensor pollicis longus rupture at the tip of a prominent screw: report of three cases J Hand Surg 18A 1993 648 651 (Pubitemid 23215646)
    • (1993) Journal of Hand Surgery , vol.18 , Issue.4 , pp. 648-651
    • Failla, J.M.1    Koniuch, M.P.2    Moed, B.R.3
  • 6
    • 34547581677 scopus 로고    scopus 로고
    • Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: A cadaveric study
    • S.D. Maschke, P.J. Evans, D. Schub, R. Drake, and J.N. Lawton Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study Hand 2 2007 144 150
    • (2007) Hand , vol.2 , pp. 144-150
    • Maschke, S.D.1    Evans, P.J.2    Schub, D.3    Drake, R.4    Lawton, J.N.5
  • 7
    • 58749103204 scopus 로고    scopus 로고
    • Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: A cadaveric study
    • A.D. Thomas, and J.A. Greenberg Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: a cadaveric study J Hand Surg 34A 2009 258 261
    • (2009) J Hand Surg , vol.34 A , pp. 258-261
    • Thomas, A.D.1    Greenberg, J.A.2
  • 8
    • 70449853877 scopus 로고    scopus 로고
    • Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis
    • W. Pichler, G. Windisch, G. Shaffler, R. Rienmller, and W. Grechenig Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis J Hand Surg 34B 2009 598 602
    • (2009) J Hand Surg , vol.34 B , pp. 598-602
    • Pichler, W.1    Windisch, G.2    Shaffler, G.3    Rienmller, R.4    Grechenig, W.5
  • 10
    • 55549113543 scopus 로고    scopus 로고
    • Screw impingement on the extensor tendons in distal radius fractures treated by volar plating: Sonographic appearance
    • S. Bianchi, J. van Aaken, T. Glauser, C. Martinoli, J.Y. Beaulieu, and D. Della Santa Screw impingement on the extensor tendons in distal radius fractures treated by volar plating: sonographic appearance Am J Roentgenol 191 2008 W199 W203
    • (2008) Am J Roentgenol , vol.191
    • Bianchi, S.1    Van Aaken, J.2    Glauser, T.3    Martinoli, C.4    Beaulieu, J.Y.5    Della Santa, D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.