메뉴 건너뛰기




Volumn 69, Issue 12, 2011, Pages 2990-2994

The effect of splinting implant-supported restorations on stress distribution of different crown-implant ratios and crown height spaces

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE SCREW; BONE STRESS; DENTAL SURGERY; SPLINTING; TOOTH CROWN; TOOTH IMPLANTATION;

EID: 84860400860     PISSN: 02782391     EISSN: 15315053     Source Type: Journal    
DOI: 10.1016/j.joms.2011.06.210     Document Type: Article
Times cited : (40)

References (27)
  • 2
    • 0032608886 scopus 로고    scopus 로고
    • Clinical rationale for tooth stabilization and splinting
    • F.G. Serio Clinical rationale for tooth stabilization and splinting Dent Clin North Am 43 1999 1
    • (1999) Dent Clin North Am , vol.43 , pp. 1
    • Serio, F.G.1
  • 3
    • 20444390462 scopus 로고    scopus 로고
    • The prosthodontic concept of crown-to-root ratio: A review of the literature
    • Y. Grossmann, and A. Sadan The prosthodontic concept of crown-to-root ratio: A review of the literature J Prosthet Dent 93 2005 559
    • (2005) J Prosthet Dent , vol.93 , pp. 559
    • Grossmann, Y.1    Sadan, A.2
  • 4
    • 0031264284 scopus 로고    scopus 로고
    • Splinting osseointegrated implants and natural teeth in rehabilitation of partially edentulous patients Part I: Laboratory and clinical studies
    • M. Gross, and B.Z. Laufer Splinting osseointegrated implants and natural teeth in rehabilitation of partially edentulous patients Part I: Laboratory and clinical studies J Oral Rehabil 24 1997 863
    • (1997) J Oral Rehabil , vol.24 , pp. 863
    • Gross, M.1    Laufer, B.Z.2
  • 5
    • 0032020453 scopus 로고    scopus 로고
    • In vivo horizontal bending moments on implants
    • E.J. Richter In vivo horizontal bending moments on implants J Oral Maxillofac Implants 13 1998 232
    • (1998) J Oral Maxillofac Implants , vol.13 , pp. 232
    • Richter, E.J.1
  • 6
    • 33644878374 scopus 로고    scopus 로고
    • Consensus conference panel report: Crown-height space guidelines for implant dentistryPart 1
    • C.E. Misch, C.J. Goodacre, and J.M. Finley Consensus conference panel report: Crown-height space guidelines for implant dentistryPart 1 Implant Dent 14 2005 312
    • (2005) Implant Dent , vol.14 , pp. 312
    • Misch, C.E.1    Goodacre, C.J.2    Finley, J.M.3
  • 7
    • 0031088442 scopus 로고    scopus 로고
    • Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible
    • L. Barbier, and E. Schepers Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible Int J Oral Maxillofac Implants 12 1997 215
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 215
    • Barbier, L.1    Schepers, E.2
  • 8
    • 0026740505 scopus 로고
    • Biomechanical factors affecting the bone-dental implant interface
    • J.B. Brunski Biomechanical factors affecting the bone-dental implant interface Clin Mater 10 1992 153
    • (1992) Clin Mater , vol.10 , pp. 153
    • Brunski, J.B.1
  • 9
    • 0031629719 scopus 로고    scopus 로고
    • Reduction of implant loading using a modified centric occlusal anatomy
    • L.A. Weinberg Reduction of implant loading using a modified centric occlusal anatomy Int J Prosthod 11 1998 550
    • (1998) Int J Prosthod , vol.11 , pp. 550
    • Weinberg, L.A.1
  • 10
    • 0030155422 scopus 로고    scopus 로고
    • Loss of osseointegration caused by occlusal load of oral implants A clinical and radiographic study in monkeys
    • F. Isidor Loss of osseointegration caused by occlusal load of oral implants A clinical and radiographic study in monkeys Clin Oral Implants Res 7 1996 143
    • (1996) Clin Oral Implants Res , vol.7 , pp. 143
    • Isidor, F.1
  • 12
    • 33748290174 scopus 로고    scopus 로고
    • Influence of forces on peri-implant bone
    • F. Isidor Influence of forces on peri-implant bone Clin Oral Implants Res 17 2006 8
    • (2006) Clin Oral Implants Res , vol.17 , pp. 8
    • Isidor, F.1
  • 13
    • 0033630481 scopus 로고    scopus 로고
    • Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future developments
    • J.B. Brunski, D.A. Puleo, and A. Nanci Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future developments Int J Oral Maxillofac Implants 15 2000 15
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 15
    • Brunski, J.B.1    Puleo, D.A.2    Nanci, A.3
  • 14
    • 33847768640 scopus 로고    scopus 로고
    • Does the type of implant prosthesis affect outcomes in the partially edentulous patient?
    • H.P. Weber, and C. Sukotjo Does the type of implant prosthesis affect outcomes in the partially edentulous patient? Int J Oral Maxillofac Implants 22 suppl 2007 140
    • (2007) Int J Oral Maxillofac Implants , vol.22 , Issue.SUPPL. , pp. 140
    • Weber, H.P.1    Sukotjo, C.2
  • 15
    • 35948961526 scopus 로고    scopus 로고
    • A 10-year prospective study of ITI dental implants placed in the posterior region II: Influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss
    • R.J. Blanes, J.P. Bernard, and Z.M. Blanes A 10-year prospective study of ITI dental implants placed in the posterior region II: Influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss Clin Oral Implants Res 18 2007 707
    • (2007) Clin Oral Implants Res , vol.18 , pp. 707
    • Blanes, R.J.1    Bernard, J.P.2    Blanes, Z.M.3
  • 16
    • 0030635617 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry
    • K.S. Hebel, and R.C. Gajjar Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry J Prosthet Dent 77 1997 28
    • (1997) J Prosthet Dent , vol.77 , pp. 28
    • Hebel, K.S.1    Gajjar, R.C.2
  • 17
    • 24744432121 scopus 로고    scopus 로고
    • Occlusal considerations for implant-supported prostheses
    • Mosby St Louis, MO
    • C.E. Misch Occlusal considerations for implant-supported prostheses Dental Implant Prosthetics 2005 Mosby St Louis, MO 472 510
    • (2005) Dental Implant Prosthetics , pp. 472-510
    • Misch, C.E.1
  • 18
    • 0036513568 scopus 로고    scopus 로고
    • Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: A numeric analysis
    • T.M. Wang, L.J. Leu, and J. Wang Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: A numeric analysis Int J Oral Maxillofac Implants 17 2002 231
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 231
    • Wang, T.M.1    Leu, L.J.2    Wang, J.3
  • 19
    • 0036559427 scopus 로고    scopus 로고
    • Effect of splinting and interproximal contact tightness on load transfer by implant restorations
    • D.L. Guichet, D. Yoshinobu, and A.A. Caputo Effect of splinting and interproximal contact tightness on load transfer by implant restorations J Prosthet Dent 87 2002 528
    • (2002) J Prosthet Dent , vol.87 , pp. 528
    • Guichet, D.L.1    Yoshinobu, D.2    Caputo, A.A.3
  • 20
    • 34447266635 scopus 로고    scopus 로고
    • Crown-to-implant ratios of single tooth implant-supported restorations
    • J. Schulte, A.M. Flores, and M. Weed Crown-to-implant ratios of single tooth implant-supported restorations J Prosthet Dent 98 2007 1
    • (2007) J Prosthet Dent , vol.98 , pp. 1
    • Schulte, J.1    Flores, A.M.2    Weed, M.3
  • 21
    • 14844362992 scopus 로고    scopus 로고
    • An assessment of crown-to-root ratios with short sintered porous-surfaced implants supporting prostheses in partially edentulous patients
    • S. Rokni, R. Todescan, and P. Watson An assessment of crown-to-root ratios with short sintered porous-surfaced implants supporting prostheses in partially edentulous patients Int J Oral Maxillofac Implants 20 2005 69
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 69
    • Rokni, S.1    Todescan, R.2    Watson, P.3
  • 22
    • 33646257306 scopus 로고    scopus 로고
    • Influence of prosthetic parameters on the survival and complication rates of short implants
    • G. Tawil, N. Aboujaoude, and R. Younan Influence of prosthetic parameters on the survival and complication rates of short implants Int J Oral Maxillofac Implants 21 2006 275
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 275
    • Tawil, G.1    Aboujaoude, N.2    Younan, R.3
  • 23
    • 11444270167 scopus 로고    scopus 로고
    • Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone
    • M. Stpideler, S.E. Eckert, and M. Zobitz Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone Int J Oral Maxillofac Implants 19 2004 819
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 819
    • Stpideler, M.1    Eckert, S.E.2    Zobitz, M.3
  • 24
    • 33748568156 scopus 로고    scopus 로고
    • Short dental implants in posterior partial edentulism: A multicenter retrospective 6-year case series study
    • C.E. Misch, J. Steignga, and E. Barboza Short dental implants in posterior partial edentulism: A multicenter retrospective 6-year case series study J Periodontol 77 2006 1340
    • (2006) J Periodontol , vol.77 , pp. 1340
    • Misch, C.E.1    Steignga, J.2    Barboza, E.3
  • 25
    • 0036560086 scopus 로고    scopus 로고
    • Two dental implants designed for immediate loading: A finite element analysis
    • L. Pierrisnard, G. Hure, and M. Barquins Two dental implants designed for immediate loading: A finite element analysis Int J Oral Maxillofac Implants 17 2002 353
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 353
    • Pierrisnard, L.1    Hure, G.2    Barquins, M.3
  • 26
    • 0036134211 scopus 로고    scopus 로고
    • Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone
    • H. plikioglu, and K. Aka Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone J Dent 30 2002 41
    • (2002) J Dent , vol.30 , pp. 41
    • Plikioglu, H.1    Aka, K.2
  • 27
    • 25444523255 scopus 로고    scopus 로고
    • Biomechanical rationale for intentionally inclined implants in the posterior mandible using 3D finite element analysis
    • T. Satoh, Y. Maeda, and Y. Komiyama Biomechanical rationale for intentionally inclined implants in the posterior mandible using 3D finite element analysis Int J Oral Maxillofac Implants 20 2005 533
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 533
    • Satoh, T.1    Maeda, Y.2    Komiyama, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.