메뉴 건너뛰기




Volumn 77, Issue 8, 2006, Pages 1340-1347

Short dental implants in posterior partial edentulism: A multicenter retrospective 6-year case series study

Author keywords

Dental implants; Prostheses

Indexed keywords

ADULT; AGED; ARTICLE; BIOMECHANICS; CANINE TOOTH; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DENTAL SURGERY; FEMALE; FOLLOW UP; HEALING; HUMAN; MAJOR CLINICAL STUDY; MALE; MECHANICAL STRESS; MULTICENTER STUDY; PERIODONTAL DISEASE; PROSTHESIS FAILURE; RETROSPECTIVE STUDY; SURGICAL APPROACH; SURVIVAL RATE; TOOTH IMPLANTATION; TOOTH OCCLUSION; TOOTH PROSTHESIS; BONE DENSITY; DENTAL CARE; DENTURE; EDENTULOUSNESS; METHODOLOGY; MIDDLE AGED; MOLAR TOOTH; PREMOLAR TOOTH; SPLINT; SURFACE PROPERTY;

EID: 33748568156     PISSN: 00223492     EISSN: None     Source Type: Journal    
DOI: 10.1902/jop.2006.050402     Document Type: Article
Times cited : (161)

References (35)
  • 1
    • 0024724096 scopus 로고
    • Osseointegrated implants in the treatment of partially edentulous patients: A preliminary study on 876 consecutively placed fixtures
    • Jemt T, Lekholm U, Adell R. Osseointegrated implants in the treatment of partially edentulous patients: A preliminary study on 876 consecutively placed fixtures. Int J Oral Maxillofac implants 1989;4:211-217.
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 211-217
    • Jemt, T.1    Lekholm, U.2    Adell, R.3
  • 2
    • 12244275012 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years
    • Pjetursson BE, Tan K, Lang NP, Bragger U, Egger M, Zwahlen M. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clin Oral Implants Res 2004;15:625-642.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 625-642
    • Pjetursson, B.E.1    Tan, K.2    Lang, N.P.3    Bragger, U.4    Egger, M.5    Zwahlen, M.6
  • 3
    • 12244286788 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years
    • Tan K, Pjetursson BE, Lang NP, Chan ES. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clin Oral Implants Res 2004; 15:654-666.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 654-666
    • Tan, K.1    Pjetursson, B.E.2    Lang, N.P.3    Chan, E.S.4
  • 5
    • 0347820719 scopus 로고
    • Divisions of available bone
    • In: Misch CE, ed. St. Louis: The CV Mosby Company
    • Misch CE. Divisions of available bone. In: Misch CE, ed. Contemporary Implant Dentistry, vol. 1. St. Louis: The CV Mosby Company; 1993:125-128.
    • (1993) Contemporary Implant Dentistry , vol.1 , pp. 125-128
    • Misch, C.E.1
  • 6
    • 0029285680 scopus 로고
    • General and local contradictions for endosteal implants - An epidemiological panoramic radiographic study in 65-year-old subjects
    • Oikarinen K, Raustia AM, Hartikainen M. General and local contradictions for endosteal implants - An epidemiological panoramic radiographic study in 65-year-old subjects. Community Dent Oral Epidemiol 1995;23:114-118.
    • (1995) Community Dent Oral Epidemiol , vol.23 , pp. 114-118
    • Oikarinen, K.1    Raustia, A.M.2    Hartikainen, M.3
  • 7
    • 0028898829 scopus 로고
    • Implant survival rates in partially edentulous patients: A 3-year prospective multicenter study
    • Higuchi KW, Folmer T, Kultje C. Implant survival rates in partially edentulous patients: A 3-year prospective multicenter study. J Oral Maxillofac Surg 1995;53: 264-268.
    • (1995) J Oral Maxillofac Surg , vol.53 , pp. 264-268
    • Higuchi, K.W.1    Folmer, T.2    Kultje, C.3
  • 8
    • 0035293260 scopus 로고    scopus 로고
    • A prospective multicenter clinical study of the Osseotite implant: Four-year interim report
    • Testori T, Wiseman L, Wolfe S, Porter SS. A prospective multicenter clinical study of the Osseotite implant: Four-year interim report. Int J Oral Maxillofac Implants 2001;16:193-200.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 193-200
    • Testori, T.1    Wiseman, L.2    Wolfe, S.3    Porter, S.S.4
  • 9
    • 0033193655 scopus 로고    scopus 로고
    • Survival of the Brånemark implant in partially edentulous jaws: A 10-year prospective multicenter study
    • Lekholm U, Gunne J, Henry P, et al. Survival of the Brånemark implant in partially edentulous jaws: A 10-year prospective multicenter study. Int J Oral Maxillofac Implants 1999;14:639-645.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 639-645
    • Lekholm, U.1    Gunne, J.2    Henry, P.3
  • 10
    • 0347418233 scopus 로고    scopus 로고
    • Clinical evaluation of short, machined-surface implants followed for 12 to 92 months
    • Tawil G, Younan R. Clinical evaluation of short, machined-surface implants followed for 12 to 92 months. Int J Oral Maxillofac Implants 2003;18:894-901.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 894-901
    • Tawil, G.1    Younan, R.2
  • 11
    • 0034208063 scopus 로고    scopus 로고
    • A prospective split-mouth comparative study of two screw-shaped self-tapping pure titanium implant systems
    • van Steenberghe D, De Mars G, Quirynen M, Jacobs R, Naert I. A prospective split-mouth comparative study of two screw-shaped self-tapping pure titanium implant systems. Clin Oral Implants Res 2000;11:202-209.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 202-209
    • van Steenberghe, D.1    De Mars, G.2    Quirynen, M.3    Jacobs, R.4    Naert, I.5
  • 12
    • 24744432513 scopus 로고    scopus 로고
    • Short dental implants: A literature review and rationale for use
    • Misch CE. Short dental implants: A literature review and rationale for use. Dent Today 2005;24:64-68.
    • (2005) Dent Today , vol.24 , pp. 64-68
    • Misch, C.E.1
  • 13
    • 0030224218 scopus 로고    scopus 로고
    • Outcome failures of endosseous implants from a clinical training center
    • 848-850,856
    • Minsk L, Polson A, Weisgold A, et al. Outcome failures of endosseous implants from a clinical training center. Compend Contin Educ Dent 1996;17:848-850,852-854,856.
    • (1996) Compend Contin Educ Dent , vol.17 , pp. 852-854
    • Minsk, L.1    Polson, A.2    Weisgold, A.3
  • 14
    • 0034585233 scopus 로고    scopus 로고
    • Implant survival to 36 months as related to length and diameter
    • Winkler S, Morris HF, Ochi S. Implant survival to 36 months as related to length and diameter. Ann Periodontol 2000;5:22-31.
    • (2000) Ann Periodontol , vol.5 , pp. 22-31
    • Winkler, S.1    Morris, H.F.2    Ochi, S.3
  • 15
    • 0042420609 scopus 로고    scopus 로고
    • A prospective multicenter clinical trial of 3i machined-surface implants: Results after 6 years of follow-up
    • Weng D, Jacobson Z, Tarnow D, et al. A prospective multicenter clinical trial of 3i machined-surface implants: Results after 6 years of follow-up. Int J Oral Maxillofac Implants 2003;18:417-423.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 417-423
    • Weng, D.1    Jacobson, Z.2    Tarnow, D.3
  • 16
    • 0036688398 scopus 로고    scopus 로고
    • Biologic outcome of implant-supported restorations in the treatment of partial edentulism. Part I: A longitudinal clinical evaluation
    • Naert I, Koutsikakis G, Duyck J. Biologic outcome of implant-supported restorations in the treatment of partial edentulism. Part I: A longitudinal clinical evaluation. Clin Oral Implants Res 2002;13:381-389.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 381-389
    • Naert, I.1    Koutsikakis, G.2    Duyck, J.3
  • 18
    • 0029303074 scopus 로고
    • Implant treatment in edentulous maxillae: A 5-year follow-up report on patients with different degrees of jaw resorption
    • Jemt T, Lekholm U. Implant treatment in edentulous maxillae: A 5-year follow-up report on patients with different degrees of jaw resorption. Int J Oral Maxillofac Implants 1995;10:303-311.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 303-311
    • Jemt, T.1    Lekholm, U.2
  • 19
    • 0030179198 scopus 로고    scopus 로고
    • An 8-year compilation of clinical results obtained with Steri-Oss endosseous implants
    • Saadoun AP, Le Gall MG. An 8-year compilation of clinical results obtained with Steri-Oss endosseous implants. Compend Contin Educ Dent 1996;17:669-674.
    • (1996) Compend Contin Educ Dent , vol.17 , pp. 669-674
    • Saadoun, A.P.1    Le Gall, M.G.2
  • 20
    • 0346207585 scopus 로고    scopus 로고
    • Influence of variation in implant diameter: A 3 to 5 year retrospective clinical report
    • Ivanoff CJ, Gronhahl K, Sennerby L, et al. Influence of variation in implant diameter: A 3 to 5 year retrospective clinical report. Int J Oral Maxillofac Implants 1999; 14:173-180.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 173-180
    • Ivanoff, C.J.1    Gronhahl, K.2    Sennerby, L.3
  • 21
    • 0032062046 scopus 로고    scopus 로고
    • Prognostic variables associated with implant failure: A retrospective effectiveness study
    • Scurria MS, Morgan V, Gucher AD, Li S, Koch G. Prognostic variables associated with implant failure: A retrospective effectiveness study. Int J Oral Maxillofac Implants 1998;13:400-406.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 400-406
    • Scurria, M.S.1    Morgan, V.2    Gucher, A.D.3    Li, S.4    Koch, G.5
  • 22
    • 0025617788 scopus 로고
    • Density of bone: Effect on treatment plans, surgical approach, healing and progressive bone loading
    • Misch CE. Density of bone: Effect on treatment plans, surgical approach, healing and progressive bone loading. Int J Oral Implantol 1990;6:23-31.
    • (1990) Int J Oral Implantol , vol.6 , pp. 23-31
    • Misch, C.E.1
  • 23
    • 0026305224 scopus 로고
    • A biomechanical rationale for the use of short implants
    • Lum LB. A biomechanical rationale for the use of short implants. J Oral Implantol 1991;17:126-131.
    • (1991) J Oral Implantol , vol.17 , pp. 126-131
    • Lum, L.B.1
  • 24
    • 0025441725 scopus 로고
    • Finite element analysis of six endosseous implants
    • Rieger MR, Mayberry M, Brose MO. Finite element analysis of six endosseous implants. J Prosthet Dent 1990;63:671-676.
    • (1990) J Prosthet Dent , vol.63 , pp. 671-676
    • Rieger, M.R.1    Mayberry, M.2    Brose, M.O.3
  • 25
    • 33751014185 scopus 로고    scopus 로고
    • Short versus long implant concepts - Functional surface areas
    • Misch CE. Short versus long implant concepts - Functional surface areas. Oral Health 1999;89:13-21.
    • (1999) Oral Health , vol.89 , pp. 13-21
    • Misch, C.E.1
  • 26
    • 0027023585 scopus 로고
    • Force transfer in implant dentistry: Basic concepts and principles
    • Bidez MW, Misch CE. Force transfer in implant dentistry: Basic concepts and principles. J Oral Implantol 1992;18:264-274.
    • (1992) J Oral Implantol , vol.18 , pp. 264-274
    • Bidez, M.W.1    Misch, C.E.2
  • 27
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaws
    • Adell R, Lekholm U, Rockler B, et al. A 15-year study of osseointegrated implants in the treatment of the edentulous jaws. Int J Oral Surg 1981;10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3
  • 28
    • 0028435430 scopus 로고
    • Effect of cantilever length on stress transfer by implant supported prostheses
    • White S, Caputo AA, Anderkvist T. Effect of cantilever length on stress transfer by implant supported prostheses. J Prosthet Dent 1994;71:493-499.
    • (1994) J Prosthet Dent , vol.71 , pp. 493-499
    • White, S.1    Caputo, A.A.2    Anderkvist, T.3
  • 29
    • 0028537747 scopus 로고
    • Implant protected occlusion: A biomechanical rationale
    • Misch CE, Bidez MW. Implant protected occlusion: A biomechanical rationale. Compendium 1994;15: 1330-1342.
    • (1994) Compendium , vol.15 , pp. 1330-1342
    • Misch, C.E.1    Bidez, M.W.2
  • 30
    • 24744432121 scopus 로고    scopus 로고
    • Occlusal considerations for implant supported prostheses. Implant protected occlusion
    • In: Misch CE, ed. St. Louis: Elsevier/Mosby
    • Misch CE. Occlusal considerations for implant supported prostheses. Implant protected occlusion. In: Misch CE, ed. Dental Implant Prosthetics. St. Louis: Elsevier/Mosby; 2005:472-510.
    • (2005) Dental Implant Prosthetics , pp. 472-510
    • Misch, C.E.1
  • 31
    • 0033067941 scopus 로고    scopus 로고
    • Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement
    • Misch CE, Qu Z, Bidez MW. Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement. J Oral Maxillofac Surg 1999;57: 700-706.
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 700-706
    • Misch, C.E.1    Qu, Z.2    Bidez, M.W.3
  • 32
    • 0345507999 scopus 로고    scopus 로고
    • Bone density: A key determinant for clinical success
    • In: Misch CE, ed. St. Louis: The CV Mosby Company
    • Misch CE. Bone density: A key determinant for clinical success. In: Misch CE, ed. Contemporary Implant Dentistry. St. Louis: The CV Mosby Company; 1999: 109-118.
    • (1999) Contemporary Implant Dentistry , pp. 109-118
    • Misch, C.E.1
  • 33
    • 0008674307 scopus 로고    scopus 로고
    • A scientific rationale of dental implant design
    • In: Misch CE, ed. St. Louis: The CV Mosby Company
    • Misch CE, Bidez MW. A scientific rationale of dental implant design. In: Misch CE, ed. Contemporary Implant Dentistry. St. Louis: The CV Mosby Company; 1999:329-343.
    • (1999) Contemporary Implant Dentistry , pp. 329-343
    • Misch, C.E.1    Bidez, M.W.2
  • 34
    • 0036356492 scopus 로고    scopus 로고
    • Bone response to machined and resorbable blast material titanium implants: An experimental study in rabbits
    • Piattelli M, Scarano A, Paolantonio M, lezzi G, Petrone G, Piattelli A. Bone response to machined and resorbable blast material titanium implants: An experimental study in rabbits. J Oral Implantol 2002;28:2-8.
    • (2002) J Oral Implantol , vol.28 , pp. 2-8
    • Piattelli, M.1    Scarano, A.2    Paolantonio, M.3    Lezzi, G.4    Petrone, G.5    Piattelli, A.6
  • 35
    • 0347189593 scopus 로고    scopus 로고
    • Functional surface area: Thread-form parameter optimization for implant body design
    • Strong JT, Misch CE, Bidez MW, Nalluri P. Functional surface area: Thread-form parameter optimization for implant body design. Compend Contin Educ Dent 1998;19:4-9.
    • (1998) Compend Contin Educ Dent , vol.19 , pp. 4-9
    • Strong, J.T.1    Misch, C.E.2    Bidez, M.W.3    Nalluri, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.