메뉴 건너뛰기




Volumn 67, Issue 5, 2012, Pages 1324-1331

Evaluation of signal formation in local arterial input function measurements of dynamic susceptibility contrast MRI

Author keywords

flow and perfusion; perfusion; technical research; technique development

Indexed keywords

3D MODELING; MAGNETIC SUSCEPTIBILITY;

EID: 84859717426     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.23120     Document Type: Article
Times cited : (9)

References (37)
  • 1
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages.1. Mathematical approach and statistical analysis
    • Ostergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR,. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages.1. Mathematical approach and statistical analysis. Magn Reson Med 1996; 36: 715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 2
    • 0028072844 scopus 로고
    • Quantification of regional cerebral blood-flow and volume with dynamic susceptibility contrast-enhanced mr-imaging
    • Rempp KA, Brix G, Wenz F, Becker CR, Guckel F, Lorenz WJ,. Quantification of regional cerebral blood-flow and volume with dynamic susceptibility contrast-enhanced mr-imaging. Radiology 1994; 193: 637-641.
    • (1994) Radiology , vol.193 , pp. 637-641
    • Rempp, K.A.1    Brix, G.2    Wenz, F.3    Becker, C.R.4    Guckel, F.5    Lorenz, W.J.6
  • 6
    • 33750594462 scopus 로고    scopus 로고
    • Perfusion-weighted MR imaging studies in brain hypervascular diseases: Comparison of arterial input function extractions for perfusion measurement
    • Ducreux D, Buvat I, Meder JF, Mikulis D, Crawley A, Fredy D, TerBrugge K, Lasjaunias P, Bittoun J,. Perfusion-weighted MR imaging studies in brain hypervascular diseases: comparison of arterial input function extractions for perfusion measurement. AJNR Am J Neuroradiol 2006; 27: 1059-1069.
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 1059-1069
    • Ducreux, D.1    Buvat, I.2    Meder, J.F.3    Mikulis, D.4    Crawley, A.5    Fredy, D.6    Terbrugge, K.7    Lasjaunias, P.8    Bittoun, J.9
  • 7
    • 33644835329 scopus 로고    scopus 로고
    • Magnetic resonance brain perfusion imaging with voxel-specific arterial input functions
    • Gruner R, Bjornara BT, Moen G, Taxt T,. Magnetic resonance brain perfusion imaging with voxel-specific arterial input functions. J Magn Reson Imaging 2006; 23: 273-284.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 273-284
    • Gruner, R.1    Bjornara, B.T.2    Moen, G.3    Taxt, T.4
  • 8
    • 4744346074 scopus 로고    scopus 로고
    • Defining a local arterial input function for perfusion MRI using independent component analysis
    • Calamante F, Morup M, Hansen LK,. Defining a local arterial input function for perfusion MRI using independent component analysis. Magn Reson Med 2004; 52: 789-797.
    • (2004) Magn Reson Med , vol.52 , pp. 789-797
    • Calamante, F.1    Morup, M.2    Hansen, L.K.3
  • 9
  • 10
    • 0035037806 scopus 로고    scopus 로고
    • Determination of arterial input function using fuzzy clustering for quantification of cerebral blood flow with dynamic susceptibility contrast-enhanced MR imaging
    • Murase K, Kikuchi K, Miki H, Shimizu T, Ikezoe J,. Determination of arterial input function using fuzzy clustering for quantification of cerebral blood flow with dynamic susceptibility contrast-enhanced MR imaging. J Magn Reson Imaging 2001; 13: 797-806.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 797-806
    • Murase, K.1    Kikuchi, K.2    Miki, H.3    Shimizu, T.4    Ikezoe, J.5
  • 11
    • 33645668089 scopus 로고    scopus 로고
    • Calculation of cerebral perfusion parameters using regional arterial input functions identified by factor analysis
    • Knutsson L, Larsson EM, Thilmann O, Stahlberg F, Wirestam R,. Calculation of cerebral perfusion parameters using regional arterial input functions identified by factor analysis. J Magn Reson Imaging 2006; 23: 444-453.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 444-453
    • Knutsson, L.1    Larsson, E.M.2    Thilmann, O.3    Stahlberg, F.4    Wirestam, R.5
  • 12
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A,. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000; 44: 466-473.
    • (2000) Magn Reson Med , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 13
    • 0032966087 scopus 로고    scopus 로고
    • Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI
    • Vonken EPA, Beekman FJ, Bakker CJG, Viergever MA,. Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI. Magn Reson Med 1999; 41: 343-350.
    • (1999) Magn Reson Med , vol.41 , pp. 343-350
    • Vonken, E.P.A.1    Beekman, F.J.2    Bakker, C.J.G.3    Viergever, M.A.4
  • 14
    • 0037587219 scopus 로고    scopus 로고
    • Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix
    • Wu O, Ostergaard L, Weisskoff RM, Benner T, Rosen BR, Sorensen AG,. Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med 2003; 50: 164-174.
    • (2003) Magn Reson Med , vol.50 , pp. 164-174
    • Wu, O.1    Ostergaard, L.2    Weisskoff, R.M.3    Benner, T.4    Rosen, B.R.5    Sorensen, A.G.6
  • 15
    • 0042739012 scopus 로고    scopus 로고
    • Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics
    • Calamante F, Yim PJ, Cebral JR,. Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics. Neuroimage 2003; 19: 341-353.
    • (2003) Neuroimage , vol.19 , pp. 341-353
    • Calamante, F.1    Yim, P.J.2    Cebral, J.R.3
  • 16
    • 0346095484 scopus 로고    scopus 로고
    • Influence of arterial input function on hypoperfusion volumes measured with perfusion-weighted imaging
    • Thijs VN, Somford DM, Bammer R, Robberecht W, Moseley ME, Albers GW,. Influence of arterial input function on hypoperfusion volumes measured with perfusion-weighted imaging. Stroke 2004; 35: 94-98.
    • (2004) Stroke , vol.35 , pp. 94-98
    • Thijs, V.N.1    Somford, D.M.2    Bammer, R.3    Robberecht, W.4    Moseley, M.E.5    Albers, G.W.6
  • 17
    • 63949086445 scopus 로고    scopus 로고
    • Optimal location for arterial input function measurements near the middle cerebral artery in first-pass perfusion MRI
    • Bleeker EJ, van Buchem MA, van Osch MJ,. Optimal location for arterial input function measurements near the middle cerebral artery in first-pass perfusion MRI. J Cereb Blood Flow Metab 2009; 29: 840-852.
    • (2009) J Cereb Blood Flow Metab , vol.29 , pp. 840-852
    • Bleeker, E.J.1    Van Buchem, M.A.2    Van Osch, M.J.3
  • 18
    • 67049134908 scopus 로고    scopus 로고
    • Analysis of partial volume effects on arterial input functions using gradient echo: A simulation study
    • Kjolby BF, Mikkelsen IK, Pedersen M, Ostergaard L, Kiselev VG,. Analysis of partial volume effects on arterial input functions using gradient echo: a simulation study. Magn Reson Med 2009; 61: 1300-1309.
    • (2009) Magn Reson Med , vol.61 , pp. 1300-1309
    • Kjolby, B.F.1    Mikkelsen, I.K.2    Pedersen, M.3    Ostergaard, L.4    Kiselev, V.G.5
  • 19
    • 28444440892 scopus 로고    scopus 로고
    • Partial volume effects on arterial input functions: Shape and amplitude distortions and their correction
    • van Osch MJP, van der Grond J, Bakker CJG,. Partial volume effects on arterial input functions: shape and amplitude distortions and their correction. J Magn Reson Imaging 2005; 22: 704-709.
    • (2005) J Magn Reson Imaging , vol.22 , pp. 704-709
    • Van Osch, M.J.P.1    Van Der Grond, J.2    Bakker, C.J.G.3
  • 22
    • 77952010972 scopus 로고    scopus 로고
    • A fully automated method for quantitative cerebral hemodynamic analysis using DSC-MRI
    • Bjornerud A, Emblem KE,. A fully automated method for quantitative cerebral hemodynamic analysis using DSC-MRI. J Cereb Blood Flow Metab 2010; 30: 1066-1078.
    • (2010) J Cereb Blood Flow Metab , vol.30 , pp. 1066-1078
    • Bjornerud, A.1    Emblem, K.E.2
  • 23
    • 0037406889 scopus 로고    scopus 로고
    • Automatic calculation of the arterial input function for cerebral perfusion imaging with MR imaging
    • Carroll TJ, Rowley HA, Haughton VM,. Automatic calculation of the arterial input function for cerebral perfusion imaging with MR imaging. Radiology 2003; 227: 593-600.
    • (2003) Radiology , vol.227 , pp. 593-600
    • Carroll, T.J.1    Rowley, H.A.2    Haughton, V.M.3
  • 25
    • 32944474414 scopus 로고    scopus 로고
    • Automated method for generating the arterial input function on perfusion-weighted MR imaging: Validation in patients with stroke
    • Mlynash M, Eyngorn I, Bammer R, Moseley M, Tong DC,. Automated method for generating the arterial input function on perfusion-weighted MR imaging: validation in patients with stroke. Am J Neuroradiol 2005; 26: 1479-1486.
    • (2005) Am J Neuroradiol , vol.26 , pp. 1479-1486
    • Mlynash, M.1    Eyngorn, I.2    Bammer, R.3    Moseley, M.4    Tong, D.C.5
  • 26
    • 79251584674 scopus 로고    scopus 로고
    • New criterion to aid manual and automatic selection of the arterial input function in dynamic susceptibility contrast MRI
    • Bleeker EJ, van Osch MJ, Connelly A, van Buchem MA, Webb AG, Calamante F,. New criterion to aid manual and automatic selection of the arterial input function in dynamic susceptibility contrast MRI. Magn Reson Med 2011; 65: 448-456.
    • (2011) Magn Reson Med , vol.65 , pp. 448-456
    • Bleeker, E.J.1    Van Osch, M.J.2    Connelly, A.3    Van Buchem, M.A.4    Webb, A.G.5    Calamante, F.6
  • 27
    • 0032251894 scopus 로고    scopus 로고
    • Convergence properties of the Nelder-Mead simplex method in low dimensions
    • Lagarias JC, Reeds JA, Wright MH, Wright PE,. Convergence properties of the Nelder-Mead simplex method in low dimensions. SIAM J Optim 1998; 9: 112-147.
    • (1998) SIAM J Optim , vol.9 , pp. 112-147
    • Lagarias, J.C.1    Reeds, J.A.2    Wright, M.H.3    Wright, P.E.4
  • 28
    • 0027494434 scopus 로고
    • A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO)
    • Liu GY, Sobering G, Duyn J, Moonen CTW,. A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO). Magn Reson Med 1993; 30: 764-768.
    • (1993) Magn Reson Med , vol.30 , pp. 764-768
    • Liu, G.Y.1    Sobering, G.2    Duyn, J.3    Moonen, C.T.W.4
  • 29
    • 33644798882 scopus 로고    scopus 로고
    • Measurement of arterial input functions for dynamic susceptibility contrast magnetic resonance imaging using echoplanar images: Comparison of physical simulations with in vivo results
    • Duhamel G, Schlaug G, Alsop DC,. Measurement of arterial input functions for dynamic susceptibility contrast magnetic resonance imaging using echoplanar images: comparison of physical simulations with in vivo results. Magn Reson Med 2006; 55: 514-523.
    • (2006) Magn Reson Med , vol.55 , pp. 514-523
    • Duhamel, G.1    Schlaug, G.2    Alsop, D.C.3
  • 30
    • 0041837657 scopus 로고    scopus 로고
    • Model of the human vasculature for studying the influence of contrast injection speed on cerebral perfusion MRI
    • van Osch MJP, Vonken EJPA, Wu O, Viergever MA, van der Grond J, Bakker CJG,. Model of the human vasculature for studying the influence of contrast injection speed on cerebral perfusion MRI. Magn Reson Med 2003; 50: 614-622.
    • (2003) Magn Reson Med , vol.50 , pp. 614-622
    • Van Osch, M.J.P.1    Vonken, E.2    Wu, O.3    Viergever, M.A.4    Van Der Grond, J.5    Bakker, C.J.G.6
  • 31
    • 4243184848 scopus 로고    scopus 로고
    • Determining the longitudinal relaxation time (T-1) of blood at 3.0 tesla
    • Lu HZ, Clingman C, Golay X, van Zijl PCM,. Determining the longitudinal relaxation time (T-1) of blood at 3.0 tesla. Magn Reson Med 2004; 52: 679-682.
    • (2004) Magn Reson Med , vol.52 , pp. 679-682
    • Lu, H.Z.1    Clingman, C.2    Golay, X.3    Van Zijl, P.C.M.4
  • 32
    • 12144281348 scopus 로고    scopus 로고
    • Pulsed star labeling of arterial regions (PULSAR): A robust regional perfusion technique for high field imaging
    • Golay X, Petersen ET, Hui F,. Pulsed star labeling of arterial regions (PULSAR): a robust regional perfusion technique for high field imaging. Magn Reson Med 2005; 53: 15-21.
    • (2005) Magn Reson Med , vol.53 , pp. 15-21
    • Golay, X.1    Petersen, E.T.2    Hui, F.3
  • 34
    • 33745685188 scopus 로고    scopus 로고
    • Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation
    • Kjolby BF, Ostergaard L, Kiselev VG,. Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation. Magn Reson Med 2006; 56: 187-197.
    • (2006) Magn Reson Med , vol.56 , pp. 187-197
    • Kjolby, B.F.1    Ostergaard, L.2    Kiselev, V.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.