-
1
-
-
0026591097
-
Hydroxyapatite orbital implant after enucleation: Experience with initial 100 consecutive cases
-
Shields C. L., Shields J. A., de Potter P., Hydroxyapatite orbital implant after enucleation: experience with initial 100 consecutive cases Archives of Ophthalmology 1992 110 3 333 339
-
(1992)
Archives of Ophthalmology
, vol.110
, Issue.3
, pp. 333-339
-
-
Shields, C.L.1
Shields, J.A.2
De Potter, P.3
-
2
-
-
0032449464
-
Intraorbital implants after enucleation and their complications: A 10- year review
-
Christmas N. J., Gordon C. D., Murray T. G., Tse D., Johnson T., Garonzik S., O'Brien D J. M., Intraorbital implants after enucleation and their complications: a 10- year review Archives of Ophthalmology 1998 116 9 1199 1203 (Pubitemid 29106441)
-
(1998)
Archives of Ophthalmology
, vol.116
, Issue.9
, pp. 1199-1203
-
-
Christmas, N.J.1
Gordon, C.D.2
Murray, T.G.3
Tse, D.4
Johnson, T.5
Garonzik, S.6
O'Brien D, J.M.7
-
3
-
-
33847607496
-
Porous Orbital Implants in Enucleation: A Systematic Review
-
DOI 10.1016/j.survophthal.2006.12.007, PII S0039625706002645
-
Chalasani R., Poole-Warren L., Conway R. M., Ben-Nissan B., Porous orbital implants in enucleation: a systematic review Survey of Ophthalmology 2007 52 2 145 155 (Pubitemid 46367857)
-
(2007)
Survey of Ophthalmology
, vol.52
, Issue.2
, pp. 145-155
-
-
Chalasani, R.1
Poole-Warren, L.2
Conway, R.M.3
Ben-Nissan, B.4
-
4
-
-
34247521109
-
Perspective on Orbital Enucleation Implants
-
DOI 10.1016/j.survophthal.2007.02.007, PII S0039625707000185
-
Sami D., Young S., Petersen R., Perspective on orbital enucleation implants Survey of Ophthalmology 2007 52 3 244 265 (Pubitemid 46654137)
-
(2007)
Survey of Ophthalmology
, vol.52
, Issue.3
, pp. 244-265
-
-
Sami, D.1
Young, S.2
Petersen, R.3
-
5
-
-
0027427652
-
Hydroxyapatite orbital implant after enucleation - Experience with 200 cases
-
Shields J. A., Shields C. L., de Potter P., Hydroxyapatite orbital implant after enucleation. Experience with 200 cases Mayo Clinic Proceedings 1993 68 12 1191 1195 (Pubitemid 23351067)
-
(1993)
Mayo Clinic Proceedings
, vol.68
, Issue.12
, pp. 1191-1195
-
-
Shields, J.A.1
Shields, C.L.2
De Potter, P.3
-
6
-
-
1642515940
-
Coralline Hydroxyapatite Orbital Implant (Bio-Eye): Experience with 158 Patients
-
DOI 10.1097/01.IOP.0000105566.71251.D9
-
Jordan D. R., Gilberg S., Bawazeer A., Coralline hydroxyapatite orbital implant (Bio-Eye): experience with 158 patients Ophthalmic Plastic and Reconstructive Surgery 2004 20 1 69 74 (Pubitemid 38120810)
-
(2004)
Ophthalmic Plastic and Reconstructive Surgery
, vol.20
, Issue.1
, pp. 69-74
-
-
Jordan, D.R.1
Gilberg, S.2
Bawazeer, A.3
-
7
-
-
0036829339
-
Long term follow up of bone derived hydroxyapatite orbital implants
-
DOI 10.1136/bjo.86.11.1287
-
Suter A. J., Molteno A. C., Bevin T. H., Fulton J. D., Herbison P., Long term follow up of bone derived hydroxyapatite orbital implants British Journal of Ophthalmology 2002 86 11 1287 1292 (Pubitemid 35238616)
-
(2002)
British Journal of Ophthalmology
, vol.86
, Issue.11
, pp. 1287-1292
-
-
Suter, A.J.1
Molteno, A.C.B.2
Bevin, T.H.3
Fulton, J.D.4
Herbison, P.5
-
8
-
-
0141508935
-
The porous polyethylene (Medpor) spherical orbital implant: A retrospective study of 136 cases
-
DOI 10.1097/01.IOP.0000083643.36461.84
-
Blaydon S. M., Shepler T. R., Neuhaus R. W., White W. L., Shore J. W., The porous polyethylene (Medpor) spherical orbital implant: a retrospective study of 136 cases Ophthalmic Plastic and Reconstructive Surgery 2003 19 5 364 371 (Pubitemid 37175451)
-
(2003)
Ophthalmic Plastic and Reconstructive Surgery
, vol.19
, Issue.5
, pp. 364-371
-
-
Blaydon, S.M.1
Shepler, T.R.2
Neuhaus, R.W.3
White, W.L.4
Shore, J.W.5
-
9
-
-
0037347290
-
The bioceramic orbital implant: Experience with 107 implants
-
DOI 10.1097/01.IOP.0000056027.63698.FE
-
Jordan D. R., Gilberg S., Mawn L. A., The bioceramic orbital implant: experience with 107 implants Ophthalmic Plastic and Reconstructive Surgery 2003 19 2 128 135 (Pubitemid 36348967)
-
(2003)
Ophthalmic Plastic and Reconstructive Surgery
, vol.19
, Issue.2
, pp. 128-135
-
-
Jordan, D.R.1
Gilberg, S.2
Mawn, L.A.3
-
10
-
-
26844540692
-
Enucleation with unwrapped porous and nonporous orbital implants: A 15-year experience
-
DOI 10.1097/01.iop.0000175034.88019.a5
-
Trichopoulos N., Augsburger J. J., Enucleation with unwrapped porous and nonporous orbital implants: a 15-year experience Ophthalmic Plastic and Reconstructive Surgery 2005 21 5 331 336 (Pubitemid 41464080)
-
(2005)
Ophthalmic Plastic and Reconstructive Surgery
, vol.21
, Issue.5
, pp. 331-336
-
-
Trichopoulos, N.1
Augsburger, J.J.2
-
11
-
-
0346432067
-
Mediation of bone ingrowth in porous hydroxyapatite bone graft substitutes
-
Hing K. A., Best S. M., Tanner K. E., Bonfield W., Revell P. A., Mediation of bone ingrowth in porous hydroxyapatite bone graft substitutes Journal of Biomedical Materials Research A 2004 68 1 187 200 (Pubitemid 38035121)
-
(2004)
Journal of Biomedical Materials Research - Part A
, vol.68
, Issue.1
, pp. 187-200
-
-
Hing, K.A.1
Best, S.M.2
Tanner, K.E.3
Bonfield, W.4
Revell, P.A.5
-
12
-
-
0028292419
-
Comparison of fibrovascular ingrowth into hydroxyapatite and porous polyethylene orbital implants
-
Rubin P. A. D., Popham J. K., Bilyk J. R., Shore J. W., Comparison of fibrovascular ingrowth into hydroxyapatite and porous polyethylene orbital implants Ophthalmic Plastic and Reconstructive Surgery 1994 10 2 96 103 (Pubitemid 24179575)
-
(1994)
Ophthalmic Plastic and Reconstructive Surgery
, vol.10
, Issue.2
, pp. 96-103
-
-
Rubin, P.A.D.1
Popham, J.K.2
Bilyk, J.R.3
Shore, J.W.4
-
13
-
-
0028143576
-
High-density porous polyethylene (Medpor) as a successful anophthalmic socket implant
-
Karesh J. W., Dresner S. C., Dutton J. J., High-density porous polyethylene (Medpor) as a successful anophthalmic socket implant Ophthalmology 1994 101 10 1688 1696 (Pubitemid 24348396)
-
(1994)
Ophthalmology
, vol.101
, Issue.10
, pp. 1688-1696
-
-
Karesh, J.W.1
Dresner, S.C.2
Dutton, J.J.3
-
14
-
-
0037241490
-
Hydroxyapatite orbital implant vascularization assessed by magnetic resonance imaging
-
DOI 10.1097/00002341-200301000-00006
-
Klapper S. R., Jordan D. R., Ells A., Grahovac S., Hydroxyapatite orbital implant vascularisation assessed by magnetic resonance imaging Ophthalmic Plastic and Reconstructive Surgery 2003 19 1 46 52 (Pubitemid 36125719)
-
(2003)
Ophthalmic Plastic and Reconstructive Surgery
, vol.19
, Issue.1
, pp. 46-52
-
-
Klapper, S.R.1
Jordan, D.R.2
Ells, A.3
Grahovac, S.4
-
15
-
-
0028944557
-
Gadolinium-enhanced magnetic resonance imaging assessment of hydroxyapatite orbital implants
-
Spirnak J. P., Nieves N., Hollsten D. A., White W. C., Betz T. A., Gadolinium-enhanced magnetic resonance imaging assessment of hydroxyapatite orbital implants American Journal of Ophthalmology 1995 119 4 431 440
-
(1995)
American Journal of Ophthalmology
, vol.119
, Issue.4
, pp. 431-440
-
-
Spirnak, J.P.1
Nieves, N.2
Hollsten, D.A.3
White, W.C.4
Betz, T.A.5
-
16
-
-
0142195923
-
Magnetic resonance evaluation of fibrovascular ingrowth into porous polyethylene orbital implant
-
DOI 10.1016/S0899-7071(03)00021-4
-
Park S. W., Seol H. Y., Hong S. J., Kim K. A., Choi J. C., Cha I. H., Magnetic resonance evaluation of fibrovascular ingrowth into porous polyethylene orbital implant Clinical Imaging 2003 27 6 377 381 (Pubitemid 37329762)
-
(2003)
Clinical Imaging
, vol.27
, Issue.6
, pp. 377-381
-
-
Park, S.W.1
Seol, H.Y.2
Hong, S.J.3
Kim, K.A.4
Choi, J.C.5
Cha, I.H.6
-
17
-
-
0037244786
-
The use of Vicryl mesh in 200 porous orbital implants: A technique with few exposures
-
DOI 10.1097/00002341-200301000-00007
-
Jordan D. R., Klapper S. R., Gilberg S. M., The use of Vicryl mesh in 200 porous orbital implants: a technique with few exposures Ophthalmic Plastic and Reconstructive Surgery 2003 19 1 53 61 (Pubitemid 36125720)
-
(2003)
Ophthalmic Plastic and Reconstructive Surgery
, vol.19
, Issue.1
, pp. 53-61
-
-
Jordan, D.R.1
Klapper, S.R.2
Gilberg, S.M.3
-
20
-
-
48649105031
-
The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: Comparison with multidetector CT
-
Yamashina A., Tanimoto K., Sutthiprapaporn P., Hayakawa Y., The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: comparison with multidetector CT Dentomaxillofacial Radiology 2008 37 5 245 251
-
(2008)
Dentomaxillofacial Radiology
, vol.37
, Issue.5
, pp. 245-251
-
-
Yamashina, A.1
Tanimoto, K.2
Sutthiprapaporn, P.3
Hayakawa, Y.4
-
21
-
-
33746104485
-
Diagnostic criteria for the detection of mandibular osteomyelitis using cone-beam computed tomography
-
DOI 10.1259/dmfr/71331738
-
Schulze D., Blessmann M., Pohlenz P., Wagner K. W., Heiland M., Diagnostic criteria for the detection of mandibular osteomyelitis using cone-beam computed tomography Dentomaxillofacial Radiology 2006 35 4 232 235 (Pubitemid 44076878)
-
(2006)
Dentomaxillofacial Radiology
, vol.35
, Issue.4
, pp. 232-235
-
-
Schulze, D.1
Blessmann, M.2
Pohlenz, P.3
Wagner, K.W.4
Heiland, M.5
-
22
-
-
67649397320
-
Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature
-
de Vos W., Casselman J., Swennen G. R. J., Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature International Journal of Oral and Maxillofacial Surgery 2009 38 6 609 625
-
(2009)
International Journal of Oral and Maxillofacial Surgery
, vol.38
, Issue.6
, pp. 609-625
-
-
De Vos, W.1
Casselman, J.2
Swennen, G.R.J.3
-
23
-
-
52649117091
-
Effect of object location on the density measurement and Hounsfield conversion in a NewTom 3G cone beam computed tomography unit
-
Lagravre M. O., Carey J., Ben-Zvi M., Packota G. V., Major P. W., Effect of object location on the density measurement and Hounsfield conversion in a NewTom 3G cone beam computed tomography unit Dentomaxillofacial Radiology 2008 37 6 305 308
-
(2008)
Dentomaxillofacial Radiology
, vol.37
, Issue.6
, pp. 305-308
-
-
Lagravre, M.O.1
Carey, J.2
Ben-Zvi, M.3
Packota, G.V.4
Major, P.W.5
-
24
-
-
33748632657
-
Three-dimensional cephalometry: Spiral multi-slice vs cone-beam computed tomography
-
DOI 10.1016/j.ajodo.2005.11.035, PII S0889540606007840
-
Swennen G. R., Schutyser F., Three-dimensional cephalometry: spiral multi-slice vs cone-beam computed tomography American Journal of Orthodontics and Dentofacial Orthopedics 2006 130 3 410 416 (Pubitemid 44376705)
-
(2006)
American Journal of Orthodontics and Dentofacial Orthopedics
, vol.130
, Issue.3
, pp. 410-416
-
-
Swennen, G.R.J.1
Schutyser, F.2
-
25
-
-
54849437519
-
Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system
-
Bryant J. A., Drage N. A., Richmond S., Study of the scan uniformity from an i-CAT cone beam computed tomography dental imaging system Dentomaxillofacial Radiology 2008 37 7 365 374
-
(2008)
Dentomaxillofacial Radiology
, vol.37
, Issue.7
, pp. 365-374
-
-
Bryant, J.A.1
Drage, N.A.2
Richmond, S.3
-
26
-
-
36148937224
-
Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography
-
Katsumata A., Hirukawa A., Okumura S., Naitoh M., Fujishita M., Ariji E., Langlais R. P., Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology 2007 104 6 829 836
-
(2007)
Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology
, vol.104
, Issue.6
, pp. 829-836
-
-
Katsumata, A.1
Hirukawa, A.2
Okumura, S.3
Naitoh, M.4
Fujishita, M.5
Ariji, E.6
Langlais, R.P.7
-
27
-
-
4143136222
-
Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): System configuration and physical properties
-
Araki K., Maki K., Seki K., Sakamaki K., Harata Y., Sakaino R., Okano T., Seo K., Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): system configuration and physical properties Dentomaxillofacial Radiology 2004 33 1 51 59
-
(2004)
Dentomaxillofacial Radiology
, vol.33
, Issue.1
, pp. 51-59
-
-
Araki, K.1
Maki, K.2
Seki, K.3
Sakamaki, K.4
Harata, Y.5
Sakaino, R.6
Okano, T.7
Seo, K.8
-
29
-
-
33845402946
-
Density conversion factor determined using a cone-beam computed tomography unit NewTom QR-DVT 9000
-
DOI 10.1259/dmfr/55276404
-
Lagravre M. O., Fang Y., Carey J., Toogood R. W., Packota G. V., Major P. W., Density conversion factor determined using a cone-beam computed tomography unit NewTom QR-DVT 9000 Dentomaxillofacial Radiology 2006 35 6 407 409 (Pubitemid 44904796)
-
(2006)
Dentomaxillofacial Radiology
, vol.35
, Issue.6
, pp. 407-409
-
-
Lagravere, M.O.1
Fang, Y.2
Carey, J.3
Toogood, R.W.4
Packota, G.V.5
Major, P.W.6
-
30
-
-
0027932582
-
Problems with the hydroxyapatite orbital implant: Experience with 250 consecutive cases
-
Shields C. L., Shields J. A., de Potter P., Singh A. D., Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases British Journal of Ophthalmology 1994 78 9 702 706 (Pubitemid 24275557)
-
(1994)
British Journal of Ophthalmology
, vol.78
, Issue.9
, pp. 702-706
-
-
Shields, C.L.1
Shields, J.A.2
De Potter, P.3
Singh, A.D.4
-
32
-
-
0026093148
-
Histopathologic evidence of fibrovascular ingrowth four weeks after placement of the hydroxyapatite orbital implant
-
Shields C. L., Shields J. A., Eagle R. C., de Potter P., Histopathologic evidence of fibrovascular ingrowth four weeks after placement of the hydroxyapatite orbital implant American Journal of Ophthalmology 1991 111 3 363 366
-
(1991)
American Journal of Ophthalmology
, vol.111
, Issue.3
, pp. 363-366
-
-
Shields, C.L.1
Shields, J.A.2
Eagle, R.C.3
De Potter, P.4
-
33
-
-
0032432030
-
Scanning electron microscopic examination of porous orbital implants
-
Mawn L. A., Jordan D. R., Gilberg S., Scanning electron microscopic examination of porous orbital implants Canadian Journal of Ophthalmology 1998 33 4 203 209 (Pubitemid 29103857)
-
(1998)
Canadian Journal of Ophthalmology
, vol.33
, Issue.4
, pp. 203-209
-
-
Mawn, L.A.1
Jordan, D.R.2
Gilberg, S.3
-
34
-
-
0035723191
-
Proliferation of human fibroblasts in vitro after exposure to orbital implants
-
Mawn L. A., Jordan D. R., Gilberg S., Proliferation of human fibroblasts in vitro after exposure to orbital implants Canadian Journal of Ophthalmology 2001 36 5 245 251 (Pubitemid 34188581)
-
(2001)
Canadian Journal of Ophthalmology
, vol.36
, Issue.5
, pp. 245-251
-
-
Mawn, L.A.1
Jordan, D.R.2
Gilberg, S.3
-
35
-
-
0026672302
-
Biocompatibility of surgical-grade dense polycrystalline alumina
-
Christel P. S., Biocompatibility of surgical-grade dense polycrystalline alumina Clinical Orthopaedics and Related Research 1992 282 10 18
-
(1992)
Clinical Orthopaedics and Related Research
, Issue.282
, pp. 10-18
-
-
Christel, P.S.1
-
36
-
-
33746517364
-
Magnetic resonance imaging assessment of fibrovascular ingrowth into porous polyethylene orbital implants
-
DOI 10.1111/j.1442-9071.2006.01222.x
-
Choi H. Y., Lee J. S., Park H. J., Oum B. S., Kim H. J., Park D. Y., Magnetic resonance imaging assessment of fibrovascular ingrowth into porous polyethylene orbital implants Clinical and Experimental Ophthalmology 2006 34 4 354 359 (Pubitemid 44137554)
-
(2006)
Clinical and Experimental Ophthalmology
, vol.34
, Issue.4
, pp. 354-359
-
-
Choi, H.Y.1
Lee, J.S.2
Park, H.J.3
Oum, B.S.4
Kim, H.J.5
Park, D.Y.6
-
37
-
-
0033766483
-
Postcontrast magnetic resonance imaging assessment of porous polyethylene orbital implant (Medpor)
-
de Potter P., Duprez T., Cosnard G., Postcontrast magnetic resonance imaging assessment of porous polyethylene orbital implant (Medpor) Ophthalmology 2000 107 9 1656 1660
-
(2000)
Ophthalmology
, vol.107
, Issue.9
, pp. 1656-1660
-
-
De Potter, P.1
Duprez, T.2
Cosnard, G.3
-
38
-
-
0029128418
-
Quantitative measurement of vascularization and vascular ingrowth rate of coralline hydroxyapatite ocular implant by Tc-99m MDP bone imaging
-
Civelek A. C., Pacheco E. M., Natarajan T. K., Wagner H. N., Iliff N. T., Quantitative measurement of vascularization and vascular ingrowth rate of coralline hydroxyapatite ocular implant by Tc-99m MDP bone imaging Clinical Nuclear Medicine 1995 20 9 779 787
-
(1995)
Clinical Nuclear Medicine
, vol.20
, Issue.9
, pp. 779-787
-
-
Civelek, A.C.1
Pacheco, E.M.2
Natarajan, T.K.3
Wagner, H.N.4
Iliff, N.T.5
-
39
-
-
9844256451
-
Clinicopathological correlation of technetium bone scan in vascularization of hydroxyapatite implants: A primate model
-
Pacheco E. M., Civelek A. C., Natarajan T. K., D'Anna S. A., Iliff N. T., Green W. R., Clinicopathological correlation of technetium bone scan in vascularization of hydroxyapatite implants: a primate model Archives of Ophthalmology 1997 115 9 1173 1177
-
(1997)
Archives of Ophthalmology
, vol.115
, Issue.9
, pp. 1173-1177
-
-
Pacheco, E.M.1
Civelek, A.C.2
Natarajan, T.K.3
D'Anna, S.A.4
Iliff, N.T.5
Green, W.R.6
-
40
-
-
27644454203
-
Effects of vascular endothelial cell growth factor on fibrovascular ingrowth into Rabbit's hydroxyapatite orbital implant
-
Zhang H., Li G., Ji C., He H., Wang J., Hu W., Wu H., Chen J., Effects of vascular endothelial cell growth factor on fibrovascular ingrowth into Rabbit's hydroxyapatite orbital implant Journal of Huazhong University of Science and TechnologyMedical Science 2004 24 3 286 288 (Pubitemid 41559636)
-
(2004)
Journal of Huazhong University of Science and Technology - Medical Science
, vol.24
, Issue.3
, pp. 286-288
-
-
Zhang, H.1
Li, G.2
Ji, C.3
He, H.4
Wang, J.5
Hu, W.6
Wu, H.7
Chen, J.8
-
41
-
-
4344624080
-
Different fibrovascularization rate between coralline hydroxyapatite and high density porous polyethylene (Medpore) measured by 99mTc-MDP bone scintigraphy 6 months after intraorbital implantation
-
Pan M. H., Wu Y. W., Yen R. F., Tzen K. Y., Liao S. L., Kao C. H., Different fibrovascularization rate between coralline hydroxyapatite and high density porous polyethylene (Medpore) measured by 99mTc-MDP bone scintigraphy 6 months after intraorbital implantation Nuclear Medicine Communications 2003 24 12 1237 1241
-
(2003)
Nuclear Medicine Communications
, vol.24
, Issue.12
, pp. 1237-1241
-
-
Pan, M.H.1
Wu, Y.W.2
Yen, R.F.3
Tzen, K.Y.4
Liao, S.L.5
Kao, C.H.6
-
42
-
-
20544435661
-
Nuclear medicine serving prostheses and biomaterials
-
DOI 10.1016/j.rbmret.2005.04.010, PII S1297956205000355
-
Bordenave L., Nuclear medicine serving prostheses and biomaterials ITBM-RBM 2005 26 3 206 211 (Pubitemid 40848470)
-
(2005)
ITBM-RBM
, vol.26
, Issue.3
, pp. 206-211
-
-
Bordenave, L.1
-
43
-
-
79551480846
-
The effect of pore size on tissue ingrowth and neovascularization in porous bioceramics of controlled architecture in vivo
-
Feng B., Jinkang Z., Zhen W., Jianxi L., Jiang C., Jian L., Guolin M., Xin D., The effect of pore size on tissue ingrowth and neovascularization in porous bioceramics of controlled architecture in vivo Biomedical Materials 2011 6 1 015007
-
(2011)
Biomedical Materials
, vol.6
, Issue.1
, pp. 015007
-
-
Feng, B.1
Jinkang, Z.2
Zhen, W.3
Jianxi, L.4
Jiang, C.5
Jian, L.6
Guolin, M.7
Xin, D.8
-
44
-
-
75149190450
-
Monitoring angiogenesis in soft-tissue engineered constructs for calvarium bone regeneration: An in vivo longitudinal DCE-MRI study
-
Beaumont M., DuVal M. G., Loai Y., Farhat W. A., Sandor G. K., Cheng H. L. M., Monitoring angiogenesis in soft-tissue engineered constructs for calvarium bone regeneration: an in vivo longitudinal DCE-MRI study NMR in Biomedicine 2010 23 1 48 55
-
(2010)
NMR in Biomedicine
, vol.23
, Issue.1
, pp. 48-55
-
-
Beaumont, M.1
Duval, M.G.2
Loai, Y.3
Farhat, W.A.4
Sandor, G.K.5
Cheng, H.L.M.6
|