메뉴 건너뛰기




Volumn 37, Issue 6, 2008, Pages 305-308

Effect of object location on the density measurement and Hounsfield conversion in a NewTom 3G cone beam computed tomography unit

Author keywords

Bone density; Computed tomography; Hounsfield value

Indexed keywords

ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; MODEL;

EID: 52649117091     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr/65993482     Document Type: Article
Times cited : (61)

References (8)
  • 1
    • 33644877729 scopus 로고    scopus 로고
    • Three-dimensional cone beam computerized tomography in orthodontics
    • Kau CH, Richmond S, Palomo JM, Hans MG. Three-dimensional cone beam computerized tomography in orthodontics. J Orthod 2005; 32: 282-93.
    • (2005) J Orthod , vol.32 , pp. 282-293
    • Kau, C.H.1    Richmond, S.2    Palomo, J.M.3    Hans, M.G.4
  • 2
    • 0021678656 scopus 로고
    • Mass estimates by computed tomography: Physical density from CT numbers
    • Mull RT. Mass estimates by computed tomography: physical density from CT numbers. AJR Am J Roentgenol 1984; 143: 1101-1104.
    • (1984) AJR Am J Roentgenol , vol.143 , pp. 1101-1104
    • Mull, R.T.1
  • 4
    • 0001091171 scopus 로고
    • Medical CAT-Scanning: X-ray absorption coefficients, CT-numbers and their relation to wood density
    • Lindgren LO. Medical CAT-Scanning: X-ray absorption coefficients, CT-numbers and their relation to wood density. Wood Sci Technol 1991; 25: 341-349.
    • (1991) Wood Sci Technol , vol.25 , pp. 341-349
    • Lindgren, L.O.1
  • 5
    • 33845769313 scopus 로고    scopus 로고
    • Dental implant success-failure analysis: A concept of implant vulnerability
    • Tolstunov L. Dental implant success-failure analysis: a concept of implant vulnerability. Implant Dent 2006; 15: 341-346.
    • (2006) Implant Dent , vol.15 , pp. 341-346
    • Tolstunov, L.1
  • 6
    • 0036201578 scopus 로고    scopus 로고
    • The dosimetric verification of commercial two- and three- dimensional radiation treatment planning systems
    • Kilic A, Ozkan L, Engin K. The dosimetric verification of commercial two- and three- dimensional radiation treatment planning systems. Turk J Med Sci 2002; 32: 133-137.
    • (2002) Turk J Med Sci , vol.32 , pp. 133-137
    • Kilic, A.1    Ozkan, L.2    Engin, K.3
  • 8
    • 0035261160 scopus 로고    scopus 로고
    • Bone classification: An objective scale of bone density using the computerized tomography scan
    • Norton MR, Gamble C. Bone classification: an objective scale of bone density using the computerized tomography scan. Clin Oral Implants Res 2001; 12: 79-84.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 79-84
    • Norton, M.R.1    Gamble, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.