메뉴 건너뛰기




Volumn 24, Issue 12, 2003, Pages 1237-1241

Different fibrovascularization rate between coralline hydroxyapatite and high density porous polyethylene (medpore) measured by 99mtc-mdp bone scintigraphy 6 months after intraorbital implantation

Author keywords

99mTc bone scan; Coralline hydroxyapatite; High density porous polyethylene (Medpore)

Indexed keywords

HYDROXYAPATITE; MEDRONATE TECHNETIUM TC 99M; POLYETHYLENE; ROSEOLIC ACID; BIOMATERIAL; CORALLINE HYDROXYAPATITE; DIAGNOSTIC AGENT; MEDPOR; POLYETHYLENE DERIVATIVE; RADIOPHARMACEUTICAL AGENT;

EID: 4344624080     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1097/00006231-200312000-00006     Document Type: Article
Times cited : (14)

References (9)
  • 1
    • 0029128418 scopus 로고
    • Quantitative measurement of vascularization and vascular ingrowth rate of coralline hydroxyapatite ocular implant by Tc-99m MDP bone scan.
    • Civelek AC, Pacheco EM, Natarajan TK, Wagner HN, Iliff NT. Quantitative measurement of vascularization and vascular ingrowth rate of coralline hydroxyapatite ocular implant by Tc-99m MDP bone scan. Clin Nucl Med 1995; 20: 779-787.
    • (1995) Clin Nucl Med , vol.20 , pp. 779-787
    • Civelek, A.C.1    Pacheco, E.M.2    Natarajan, T.K.3    Wagner, H.N.4    Iliff, N.T.5
  • 2
    • 0025976934 scopus 로고
    • Coralline hydroxyapatite as an ocular implant.
    • Dutton JJ. Coralline hydroxyapatite as an ocular implant. Ophthalmology 1991; 98: 370-371.
    • (1991) Ophthalmology , vol.98 , pp. 370-371
    • Dutton, J.J.1
  • 3
    • 0026093148 scopus 로고
    • Histopathologic evidence of fibrovascular ingrowth four weeks after placement of the hydroxyapatite orbital implant.
    • Shields CL, Shields JA, Eagle RC, De Potter P. Histopathologic evidence of fibrovascular ingrowth four weeks after placement of the hydroxyapatite orbital implant. Am J Ophthalmol 1991; 111: 363-366.
    • (1991) Am J Ophthalmol , vol.111 , pp. 363-366
    • Shields, C.L.1    Shields, J.A.2    Eagle, R.C.3    De Potter, P.4
  • 4
    • 0027932582 scopus 로고
    • Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases.
    • Shields CL, Shields JA, De Potter P, Singh AD. Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases. Br J Ophthalmol 1994; 78: 702-706.
    • (1994) Br J Ophthalmol , vol.78 , pp. 702-706
    • Shields, C.L.1    Shields, J.A.2    De Potter, P.3    Singh, A.D.4
  • 5
    • 0028143576 scopus 로고
    • High-density porous polyethylene (Medpore) as a successful anophthalmic socket implant.
    • Karesh JW, Dresner SC. High-density porous polyethylene (Medpore) as a successful anophthalmic socket implant. Ophthalmology 1994; 101: 1688-1696.
    • (1994) Ophthalmology , vol.101 , pp. 1688-1696
    • Karesh, J.W.1    Dresner, S.C.2
  • 7
    • 0026734386 scopus 로고
    • Rate of vascularization of coralline hydroxyapatite ocular implants.
    • Ferrone PJ, Dutton JJ. Rate of vascularization of coralline hydroxyapatite ocular implants. Ophthalmology 1992; 99: 376-379.
    • (1992) Ophthalmology , vol.99 , pp. 376-379
    • Ferrone, P.J.1    Dutton, J.J.2
  • 8
    • 9844256451 scopus 로고    scopus 로고
    • Clinicopathological correlation of technetium bone scan in vascularization of hydroxyapatite implants: a primate model.
    • Pacheco E, Civelek AC, Natarajan TK, D'Anna SA, Iliff NT, Green W. Clinicopathological correlation of technetium bone scan in vascularization of hydroxyapatite implants: a primate model. Arch Ophthalmol 1997; 115: 1173-1177.
    • (1997) Arch Ophthalmol , vol.115 , pp. 1173-1177
    • Pacheco, E.1    Civelek, A.C.2    Natarajan, T.K.3    DAnna, S.A.4    Iliff, N.T.5    Green, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.