메뉴 건너뛰기




Volumn 38, Issue 2, 2012, Pages 135-143

Evaluating heparin-induced thrombocytopenia: The old and the new

Author keywords

clinical scoring; functional assays; heparin induced thrombocytopenia; heparin platelet factor 4 enzyme immunoassays; heparin platelet factor 4 particle gel immunoassay

Indexed keywords

ANTITHROMBOCYTIC AGENT; HEPARIN; IMMUNOGLOBULIN G ANTIBODY; LOW MOLECULAR WEIGHT HEPARIN; POLYVINYL DERIVATIVE; POLYVINYL SULFATE; THROMBIN; THROMBOCYTE FACTOR 4; UNCLASSIFIED DRUG;

EID: 84858126548     PISSN: 00946176     EISSN: 10989064     Source Type: Journal    
DOI: 10.1055/s-0032-1301411     Document Type: Review
Times cited : (22)

References (82)
  • 1
    • 13544251729 scopus 로고    scopus 로고
    • New approaches to the diagnosis of heparin-induced thrombocytopenia
    • DOI 10.1378/chest.127.2-suppl.35S
    • Warkentin TE. New approaches to the diagnosis of heparin-induced thrombocytopenia. Chest: 2005; 127 2, Suppl 35S 45S (Pubitemid 40224080)
    • (2005) Chest , vol.127 , Issue.SUPPL. 13
    • Warkentin, T.E.1
  • 2
    • 54049143619 scopus 로고    scopus 로고
    • A clinical-laboratory approach contributing to a rapid and reliable diagnosis of heparin-induced thrombocytopenia
    • Denys B, Stove V, Philipp J, Devreese K. A clinical-laboratory approach contributing to a rapid and reliable diagnosis of heparin-induced thrombocytopenia. Thromb Res: 2008; 123 1 137 145
    • (2008) Thromb Res , vol.123 , Issue.1 , pp. 137-145
    • Denys, B.1    Stove, V.2    Philipp, J.3    Devreese, K.4
  • 3
    • 67849083115 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia
    • Greinacher A. Heparin-induced thrombocytopenia. J Thromb Haemost: 2009; 7 Suppl 1 9 12
    • (2009) J Thromb Haemost , vol.7 , Issue.SUPPL. 1 , pp. 9-12
    • Greinacher, A.1
  • 4
    • 34247127070 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia in intensive care patients
    • DOI 10.1097/01.CCM.0000259538.02375.A5
    • Selleng K, Warkentin TE, Greinacher A. Heparin-induced thrombocytopenia in intensive care patients. Crit Care Med: 2007; 35 4 1165 1176 (Pubitemid 46598970)
    • (2007) Critical Care Medicine , vol.35 , Issue.4 , pp. 1165-1176
    • Selleng, K.1    Warkentin, T.E.2    Greinacher, A.3
  • 5
    • 55049099272 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia in intensive care patients
    • Selleng K, Selleng S, Greinacher A. Heparin-induced thrombocytopenia in intensive care patients. Semin Thromb Hemost: 2008; 34 5 425 438
    • (2008) Semin Thromb Hemost , vol.34 , Issue.5 , pp. 425-438
    • Selleng, K.1    Selleng, S.2    Greinacher, A.3
  • 6
    • 79953011172 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia in the ICU: An overview
    • Sakr Y. Heparin-induced thrombocytopenia in the ICU: an overview. Crit Care: 2011; 15 2 211
    • (2011) Crit Care , vol.15 , Issue.2 , pp. 211
    • Sakr, Y.1
  • 7
    • 33748893828 scopus 로고    scopus 로고
    • Testing for Heparin-Induced Thrombocytopenia Antibodies
    • DOI 10.1016/j.tmrv.2006.05.001, PII S0887796306000290
    • Warkentin TE, Sheppard JA. Testing for heparin-induced thrombocytopenia antibodies. Transfus Med Rev: 2006; 20 4 259 272 (Pubitemid 44428106)
    • (2006) Transfusion Medicine Reviews , vol.20 , Issue.4 , pp. 259-272
    • Warkentin, T.E.1    Sheppard, J.-A.I.2
  • 9
    • 77955869101 scopus 로고    scopus 로고
    • Diagnostic strategy in heparin induced thrombocytopenia
    • Kannan M, Ahmad S, Fareed J, Saxena R. Diagnostic strategy in heparin induced thrombocytopenia. Eastern J Med: 2009; 14 78 83
    • (2009) Eastern J Med , vol.14 , pp. 78-83
    • Kannan, M.1    Ahmad, S.2    Fareed, J.3    Saxena, R.4
  • 10
    • 0038392539 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia: Pathogenesis and management
    • DOI 10.1046/j.1365-2141.2003.04334.x
    • Warkentin TE. Heparin-induced thrombocytopenia: pathogenesis and management. Br J Haematol: 2003; 121 4 535 555 (Pubitemid 36645375)
    • (2003) British Journal of Haematology , vol.121 , Issue.4 , pp. 535-555
    • Warkentin, T.E.1
  • 11
    • 33644971524 scopus 로고    scopus 로고
    • Evaluation of pretest clinical score (4 T's) for the diagnosis of heparin-induced thrombocytopenia in two clinical settings
    • Lo GK, Juhl D, Warkentin TE, Sigouin CS, Eichler P, Greinacher A. Evaluation of pretest clinical score (4 T's) for the diagnosis of heparin-induced thrombocytopenia in two clinical settings. J Thromb Haemost: 2006; 4 4 759 765
    • (2006) J Thromb Haemost , vol.4 , Issue.4 , pp. 759-765
    • Lo, G.K.1    Juhl, D.2    Warkentin, T.E.3    Sigouin, C.S.4    Eichler, P.5    Greinacher, A.6
  • 12
    • 34250767666 scopus 로고    scopus 로고
    • Prospective evaluation of the '4Ts' score and particle gel immunoassay specific to heparin/PF4 for the diagnosis of heparin-induced thrombocytopenia
    • DOI 10.1111/j.1538-7836.2007.02524.x
    • Pouplard C, Gueret P, Fouassier M., et al. Prospective evaluation of the 4Ts' score and particle gel immunoassay specific to heparin/PF4 for the diagnosis of heparin-induced thrombocytopenia. J Thromb Haemost: 2007; 5 7 1373 1379 (Pubitemid 46965362)
    • (2007) Journal of Thrombosis and Haemostasis , vol.5 , Issue.7 , pp. 1373-1379
    • Pouplard, C.1    Gueret, P.2    Fouassier, M.3    Ternisien, C.4    Trossaert, M.5    Regina, S.6    Gruel, Y.7
  • 13
    • 77953286757 scopus 로고    scopus 로고
    • The 4Ts scoring system for heparin-induced thrombocytopenia in medical-surgical intensive care unit patients
    • Canadian Critical Care Trials Group.
    • Crowther MA, Cook DJ, Albert M., et al. Canadian Critical Care Trials Group. The 4Ts scoring system for heparin-induced thrombocytopenia in medical-surgical intensive care unit patients. J Crit Care: 2010; 25 2 287 293
    • (2010) J Crit Care , vol.25 , Issue.2 , pp. 287-293
    • Crowther, M.A.1    Cook, D.J.2    Albert, M.3
  • 14
    • 78650000811 scopus 로고    scopus 로고
    • The HIT Expert Probability (HEP) Score: A novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion
    • Cuker A, Arepally G, Crowther MA., et al. The HIT Expert Probability (HEP) Score: a novel pre-test probability model for heparin-induced thrombocytopenia based on broad expert opinion. J Thromb Haemost: 2010; 8 12 2642 2650
    • (2010) J Thromb Haemost , vol.8 , Issue.12 , pp. 2642-2650
    • Cuker, A.1    Arepally, G.2    Crowther, M.A.3
  • 15
    • 79959504577 scopus 로고    scopus 로고
    • Overdiagnosis of heparin-induced thrombocytopenia in surgical ICU patients
    • Berry C, Tcherniantchouk O, Ley EJ., et al. Overdiagnosis of heparin-induced thrombocytopenia in surgical ICU patients. J Am Coll Surg: 2011; 213 1 10 17, discussion 17-18
    • (2011) J Am Coll Surg , vol.213 , Issue.1 , pp. 10-17
    • Berry, C.1    Tcherniantchouk, O.2    Ley, E.J.3
  • 16
    • 55949102332 scopus 로고    scopus 로고
    • Timely diagnosis and management of heparin-induced thrombocytopenia in a frequent request, low incidence single centre using clinical 4T's score and particle gel immunoassay
    • Bryant A, Low J, Austin S, Joseph JE. Timely diagnosis and management of heparin-induced thrombocytopenia in a frequent request, low incidence single centre using clinical 4T's score and particle gel immunoassay. Br J Haematol: 2008; 143 5 721 726
    • (2008) Br J Haematol , vol.143 , Issue.5 , pp. 721-726
    • Bryant, A.1    Low, J.2    Austin, S.3    Joseph, J.E.4
  • 18
    • 67949124723 scopus 로고    scopus 로고
    • Prospective evaluation of PF4/heparin immunoassays for the diagnosis of heparin-induced thrombocytopenia
    • Bakchoul T, Giptner A, Najaoui A, Bein G, Santoso S, Sachs UJ. Prospective evaluation of PF4/heparin immunoassays for the diagnosis of heparin-induced thrombocytopenia. J Thromb Haemost: 2009; 7 8 1260 1265
    • (2009) J Thromb Haemost , vol.7 , Issue.8 , pp. 1260-1265
    • Bakchoul, T.1    Giptner, A.2    Najaoui, A.3    Bein, G.4    Santoso, S.5    Sachs, U.J.6
  • 19
    • 77952672716 scopus 로고    scopus 로고
    • Clinical characteristics and laboratory testing of patients with suspected HIT: A survey on current practice in 11 university hospitals in France
    • GEHT-HIT study group.
    • Bidet A, Tardy Poncet B, Desprez D., et al. GEHT-HIT study group. Clinical characteristics and laboratory testing of patients with suspected HIT: a survey on current practice in 11 university hospitals in France. Thromb Res: 2010; 125 6 e294 e299
    • (2010) Thromb Res , vol.125 , Issue.6
    • Bidet, A.1    Tardy Poncet, B.2    Desprez, D.3
  • 20
    • 77956495415 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia: Current status and diagnostic challenges
    • Otis SA, Zehnder JL. Heparin-induced thrombocytopenia: current status and diagnostic challenges. Am J Hematol: 2010; 85 9 700 706
    • (2010) Am J Hematol , vol.85 , Issue.9 , pp. 700-706
    • Otis, S.A.1    Zehnder, J.L.2
  • 21
    • 79952502409 scopus 로고    scopus 로고
    • A clinical-laboratory algorithm incorporating optical density value to predict heparin-induced thrombocytopenia
    • Ruf KM, Bensadoun ES, Davis GA, Flynn JD, Lewis DA. A clinical-laboratory algorithm incorporating optical density value to predict heparin-induced thrombocytopenia. Thromb Haemost: 2011; 105 3 553 559
    • (2011) Thromb Haemost , vol.105 , Issue.3 , pp. 553-559
    • Ruf, K.M.1    Bensadoun, E.S.2    Davis, G.A.3    Flynn, J.D.4    Lewis, D.A.5
  • 22
    • 0026638091 scopus 로고
    • Platelet factor 4 complexed to heparin is the target for antibodies generated in heparin-induced thrombocytopenia
    • Amiral J, Bridey F, Dreyfus M., et al. Platelet factor 4 complexed to heparin is the target for antibodies generated in heparin-induced thrombocytopenia. Thromb Haemost: 1992; 68 1 95 96
    • (1992) Thromb Haemost , vol.68 , Issue.1 , pp. 95-96
    • Amiral, J.1    Bridey, F.2    Dreyfus, M.3
  • 23
    • 34447617364 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia: A prospective study on the incidence, platelet-activating capacity and clinical significance of antiplatelet factor 4/heparin antibodies of the IgG, IgM, and IgA classes
    • DOI 10.1111/j.1538-7836.2007.02617.x
    • Greinacher A, Juhl D, Strobel U., et al. Heparin-induced thrombocytopenia: a prospective study on the incidence, platelet-activating capacity and clinical significance of antiplatelet factor 4/heparin antibodies of the IgG, IgM, and IgA classes. J Thromb Haemost: 2007; 5 8 1666 1673 (Pubitemid 47091409)
    • (2007) Journal of Thrombosis and Haemostasis , vol.5 , Issue.8 , pp. 1666-1673
    • Greinacher, A.1    Juhl, D.2    Strobel, U.3    Wessel, A.4    Lubenow, N.5    Selleng, K.6    Eichler, P.7    Warkentin, T.E.8
  • 24
    • 36749095644 scopus 로고    scopus 로고
    • What is the potential for overdiagnosis of heparin-induced thrombocytopenia?
    • DOI 10.1002/ajh.21032
    • Lo GK, Sigouin CS, Warkentin TE. What is the potential for overdiagnosis of heparin-induced thrombocytopenia? Am J Hematol: 2007; 82 12 1037 1043 (Pubitemid 350209843)
    • (2007) American Journal of Hematology , vol.82 , Issue.12 , pp. 1037-1043
    • Lo, G.K.1    Sigouin, C.S.2    Warkentin, T.E.3
  • 25
    • 45949112509 scopus 로고    scopus 로고
    • Quantitative interpretation of optical density measurements using PF4-dependent enzyme-immunoassays
    • DOI 10.1111/j.1538-7836.2008.03025.x
    • Warkentin TE, Sheppard JI, Moore JC, Sigouin CS, Kelton JG. Quantitative interpretation of optical density measurements using PF4-dependent enzyme-immunoassays. J Thromb Haemost: 2008; 6 8 1304 1312 (Pubitemid 352016309)
    • (2008) Journal of Thrombosis and Haemostasis , vol.6 , Issue.8 , pp. 1304-1312
    • Warkentin, T.E.1    Sheppard, J.I.2    Moore, J.C.3    Sigouin, C.S.4    Kelton, J.G.5
  • 26
    • 0036118897 scopus 로고    scopus 로고
    • The new ID-heparin/PF4 antibody test for rapid detection of heparin-induced antibodies in comparison with functional and antigenic assays
    • DOI 10.1046/j.0007-1048.2002.03363.x
    • Eichler P, Raschke R, Lubenow N, Meyer O, Schwind P, Greinacher A. The new ID-heparin/PF4 antibody test for rapid detection of heparin-induced antibodies in comparison with functional and antigenic assays. Br J Haematol: 2002; 116 4 887 891 (Pubitemid 34227011)
    • (2002) British Journal of Haematology , vol.116 , Issue.4 , pp. 887-891
    • Eichler, P.1    Raschke, R.2    Lubenow, N.3    Meyer, O.4    Schwind, P.5    Greinacher, A.6
  • 27
    • 0036086107 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia: Detection of antiheparin/PF4 antibodies by means of heparin/PF4-coated beads and flow cytometry
    • DOI 10.1046/j.1365-3148.2002.00376.x
    • Tazzari PL, Ricci F, Vitale M., et al. Heparin-induced thrombocytopenia: detection of antiheparin/PF4 antibodies by means of heparin/PF4-coated beads and flow cytometry. Transfus Med: 2002; 12 3 193 198 (Pubitemid 34685874)
    • (2002) Transfusion Medicine , vol.12 , Issue.3 , pp. 193-198
    • Tazzari, P.L.1    Ricci, F.2    Vitale, M.3    Malferrari, F.4    Salama, A.5    Schwind, P.6    Conte, R.7
  • 28
    • 67949112765 scopus 로고    scopus 로고
    • Immunoassays are not created equal
    • Warkentin TE, Linkins LA. Immunoassays are not created equal. J Thromb Haemost: 2009; 7 8 1256 1259
    • (2009) J Thromb Haemost , vol.7 , Issue.8 , pp. 1256-1259
    • Warkentin, T.E.1    Linkins, L.A.2
  • 29
    • 70350011962 scopus 로고    scopus 로고
    • Variability of anti-PF4/heparin antibody results obtained by the rapid testing system ID-H/PF4-PaGIA
    • Schneiter S, Colucci G, Sulzer I, Barizzi G, Lämmle B, Alberio L. Variability of anti-PF4/heparin antibody results obtained by the rapid testing system ID-H/PF4-PaGIA. J Thromb Haemost: 2009; 7 10 1649 1655
    • (2009) J Thromb Haemost , vol.7 , Issue.10 , pp. 1649-1655
    • Schneiter, S.1    Colucci, G.2    Sulzer, I.3    Barizzi, G.4    Lämmle, B.5    Alberio, L.6
  • 30
    • 35448991365 scopus 로고    scopus 로고
    • Performance characteristics of a rapid assay for anti-PF4/heparin antibodies: The particle immunofiltration assay [5]
    • DOI 10.1111/j.1538-7836.2007.02723.x
    • Warkentin TE, Sheppard JI, Raschke R, Greinacher A. Performance characteristics of a rapid assay for anti-PF4/heparin antibodies: the particle immunofiltration assay. J Thromb Haemost: 2007; 5 11 2308 2310 (Pubitemid 47617888)
    • (2007) Journal of Thrombosis and Haemostasis , vol.5 , Issue.11 , pp. 2308-2310
    • Warkentin, T.E.1    Sheppard, J.I.2    Raschke, R.3    Greinacher, A.4
  • 31
    • 73049111995 scopus 로고    scopus 로고
    • The use of well-characterized sera for the assessment of new diagnostic enzyme-immunoassays for the diagnosis of heparin-induced thrombocytopenia
    • Warkentin TE, Sheppard JI, Moore JC, Kelton JG. The use of well-characterized sera for the assessment of new diagnostic enzyme-immunoassays for the diagnosis of heparin-induced thrombocytopenia. J Thromb Haemost: 2010; 8 1 216 218
    • (2010) J Thromb Haemost , vol.8 , Issue.1 , pp. 216-218
    • Warkentin, T.E.1    Sheppard, J.I.2    Moore, J.C.3    Kelton, J.G.4
  • 32
    • 0031850163 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia: IgG binding to PF4-heparin complexes in the fluid phase and cross-reactivity with low molecular weight heparin and heparinoid
    • Newman PM, Swanson RL, Chong BH. Heparin-induced thrombocytopenia: IgG binding to PF4-heparin complexes in the fluid phase and cross-reactivity with low molecular weight heparin and heparinoid. Thromb Haemost: 1998; 80 2 292 297 (Pubitemid 28393626)
    • (1998) Thrombosis and Haemostasis , vol.80 , Issue.2 , pp. 292-297
    • Newman, P.M.1    Swanson, R.L.2    Chong, B.H.3
  • 33
    • 79952993615 scopus 로고    scopus 로고
    • Performance characteristics of two commercially available IgG-specific immunoassays in the assessment of heparin-induced thrombocytopenia (HIT)
    • Bakchoul T, Giptner A, Bein G, Santoso S, Sachs UJ. Performance characteristics of two commercially available IgG-specific immunoassays in the assessment of heparin-induced thrombocytopenia (HIT). Thromb Res: 2011; 127 4 345 348
    • (2011) Thromb Res , vol.127 , Issue.4 , pp. 345-348
    • Bakchoul, T.1    Giptner, A.2    Bein, G.3    Santoso, S.4    Sachs, U.J.5
  • 34
    • 33645723747 scopus 로고    scopus 로고
    • Incidence and clinical significance of anti-PF4/heparin antibodies of the IgG, IgM, and IgA class in 755 consecutive patient samples referred for diagnostic testing for heparin-induced thrombocytopenia
    • Juhl D, Eichler P, Lubenow N, Strobel U, Wessel A, Greinacher A. Incidence and clinical significance of anti-PF4/heparin antibodies of the IgG, IgM, and IgA class in 755 consecutive patient samples referred for diagnostic testing for heparin-induced thrombocytopenia. Eur J Haematol: 2006; 76 5 420 426
    • (2006) Eur J Haematol , vol.76 , Issue.5 , pp. 420-426
    • Juhl, D.1    Eichler, P.2    Lubenow, N.3    Strobel, U.4    Wessel, A.5    Greinacher, A.6
  • 35
    • 36748998833 scopus 로고    scopus 로고
    • Too many hits in HIT
    • Greinacher A. Too many hits in HIT? Am J Hematol: 2007; 82 12 1035 1036
    • (2007) Am J Hematol , vol.82 , Issue.12 , pp. 1035-1036
    • Greinacher, A.1
  • 36
    • 33847371134 scopus 로고    scopus 로고
    • High prevalence of antibodies to platelet factor 4 heparin in patients with antiphospholipid antibodies in absence of heparin-induced thrombocytopenia
    • DOI 10.1177/0961203306075562
    • Martin-Toutain I, Piette JC, Diemert MC, Faucher C, Jobic L, Ankri A. High prevalence of antibodies to platelet factor 4 heparin in patients with antiphospholipid antibodies in absence of heparin-induced thrombocytopenia. Lupus: 2007; 16 2 79 83 (Pubitemid 46347928)
    • (2007) Lupus , vol.16 , Issue.2 , pp. 79-83
    • Martin-Toutain, I.1    Piette, J.C.2    Diemert, M.C.3    Faucher, C.4    Jobic, L.5    Ankri, A.6
  • 37
    • 67649470557 scopus 로고    scopus 로고
    • False-positive tests for heparin-induced thrombocytopenia in patients with antiphospholipid syndrome and systemic lupus erythematosus
    • Pauzner R, Greinacher A, Selleng K, Althaus K, Shenkman B, Seligsohn U. False-positive tests for heparin-induced thrombocytopenia in patients with antiphospholipid syndrome and systemic lupus erythematosus. J Thromb Haemost: 2009; 7 7 1070 1074
    • (2009) J Thromb Haemost , vol.7 , Issue.7 , pp. 1070-1074
    • Pauzner, R.1    Greinacher, A.2    Selleng, K.3    Althaus, K.4    Shenkman, B.5    Seligsohn, U.6
  • 38
    • 54949085747 scopus 로고    scopus 로고
    • Anti-heparin/platelet factor 4 antibody optical density values and the confirmatory procedure in the diagnosis of heparin-induced thrombocytopenia
    • Whitlatch NL, Perry SL, Ortel TL. Anti-heparin/platelet factor 4 antibody optical density values and the confirmatory procedure in the diagnosis of heparin-induced thrombocytopenia. Thromb Haemost: 2008; 100 4 678 684
    • (2008) Thromb Haemost , vol.100 , Issue.4 , pp. 678-684
    • Whitlatch, N.L.1    Perry, S.L.2    Ortel, T.L.3
  • 39
    • 77955464540 scopus 로고    scopus 로고
    • Incidence and clinical relevance of anti-platelet factor 4/heparin antibodies before cardiac surgery
    • Selleng S, Malowsky B, Itterman T., et al. Incidence and clinical relevance of anti-platelet factor 4/heparin antibodies before cardiac surgery. Am Heart J: 2010; 160 2 362 369
    • (2010) Am Heart J , vol.160 , Issue.2 , pp. 362-369
    • Selleng, S.1    Malowsky, B.2    Itterman, T.3
  • 40
    • 78851468851 scopus 로고    scopus 로고
    • Venous limb gangrene and fatal hemorrhage: Adverse consequences of HIT "overdiagnosiso" in a patient with antiphospholipid syndrome
    • Smythe MA, Warkentin TE, Woodhouse AL, Zakalik D. Venous limb gangrene and fatal hemorrhage: adverse consequences of HIT "overdiagnosiso" in a patient with antiphospholipid syndrome. Am J Hematol: 2011; 86 2 188 191
    • (2011) Am J Hematol , vol.86 , Issue.2 , pp. 188-191
    • Smythe, M.A.1    Warkentin, T.E.2    Woodhouse, A.L.3    Zakalik, D.4
  • 41
    • 74249094682 scopus 로고    scopus 로고
    • Effectiveness of a new immunoassay for the diagnosis of heparin-induced thrombocytopenia and improved specificity when detecting IgG antibodies
    • Pouplard C, Leroux D, Regina S, Rollin J, Gruel Y. Effectiveness of a new immunoassay for the diagnosis of heparin-induced thrombocytopenia and improved specificity when detecting IgG antibodies. Thromb Haemost: 2010; 103 1 145 150
    • (2010) Thromb Haemost , vol.103 , Issue.1 , pp. 145-150
    • Pouplard, C.1    Leroux, D.2    Regina, S.3    Rollin, J.4    Gruel, Y.5
  • 42
    • 79954594754 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia: Evaluation of IgG and IgGAM ELISA assays
    • Morel-Kopp MC, Aboud M, Tan CW, Kulathilake C, Ward C. Heparin-induced thrombocytopenia: evaluation of IgG and IgGAM ELISA assays. Int J Lab Hematol: 2011; 33 3 245 250
    • (2011) Int J Lab Hematol , vol.33 , Issue.3 , pp. 245-250
    • Morel-Kopp, M.C.1    Aboud, M.2    Tan, C.W.3    Kulathilake, C.4    Ward, C.5
  • 43
    • 77956483253 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia: Towards standardization of platelet factor 4/heparin antigen tests
    • Greinacher A, Ittermann T, Bagemühl J., et al. Heparin-induced thrombocytopenia: towards standardization of platelet factor 4/heparin antigen tests. J Thromb Haemost: 2010; 8 9 2025 2031
    • (2010) J Thromb Haemost , vol.8 , Issue.9 , pp. 2025-2031
    • Greinacher, A.1    Ittermann, T.2    Bagemühl, J.3
  • 44
    • 13244268431 scopus 로고    scopus 로고
    • Thrombosis and ELISA optical density values in hospitalized patients with heparin-induced thrombocytopenia
    • DOI 10.1111/j.1538-7836.2004.01039.x
    • Zwicker JI, Uhl L, Huang WY, Shaz BH, Bauer KA. Thrombosis and ELISA optical density values in hospitalized patients with heparin-induced thrombocytopenia. J Thromb Haemost: 2004; 2 12 2133 2137 (Pubitemid 40185772)
    • (2004) Journal of Thrombosis and Haemostasis , vol.2 , Issue.12 , pp. 2133-2137
    • Zwicker, J.I.1    Uhl, L.2    Huang, W.-Y.3    Shaz, B.H.4    Bauer, K.A.5
  • 45
    • 77956593113 scopus 로고    scopus 로고
    • Validation of the high-dose heparin confirmatory step for the diagnosis of heparin-induced thrombocytopenia
    • Whitlatch NL, Kong DF, Metjian AD, Arepally GM, Ortel TL. Validation of the high-dose heparin confirmatory step for the diagnosis of heparin-induced thrombocytopenia. Blood: 2010; 116 10 1761 1766
    • (2010) Blood , vol.116 , Issue.10 , pp. 1761-1766
    • Whitlatch, N.L.1    Kong, D.F.2    Metjian, A.D.3    Arepally, G.M.4    Ortel, T.L.5
  • 46
    • 33644610355 scopus 로고    scopus 로고
    • No significant improvement in diagnostic specificity of an anti-PF4/polyanion immunoassay with use of high heparin confirmatory procedure
    • Warkentin TE, Sheppard JI. No significant improvement in diagnostic specificity of an anti-PF4/polyanion immunoassay with use of high heparin confirmatory procedure. J Thromb Haemost: 2006; 4 1 281 282
    • (2006) J Thromb Haemost , vol.4 , Issue.1 , pp. 281-282
    • Warkentin, T.E.1    Sheppard, J.I.2
  • 47
    • 79953175924 scopus 로고    scopus 로고
    • The diagnostic value of the anti-PF4/heparin immunoassay high-dose heparin confirmatory test in cardiac surgery patients
    • Selleng S, Schreier N, Wollert HG, Greinacher A. The diagnostic value of the anti-PF4/heparin immunoassay high-dose heparin confirmatory test in cardiac surgery patients. Anesth Analg: 2011; 112 4 774 776
    • (2011) Anesth Analg , vol.112 , Issue.4 , pp. 774-776
    • Selleng, S.1    Schreier, N.2    Wollert, H.G.3    Greinacher, A.4
  • 48
    • 79960638918 scopus 로고    scopus 로고
    • Combined use of the high heparin step and optical density to optimize diagnostic sensitivity and specificity of an anti-PF4/heparin enzyme-immunoassay
    • Althaus K, Strobel U, Warkentin TE, Greinacher A. Combined use of the high heparin step and optical density to optimize diagnostic sensitivity and specificity of an anti-PF4/heparin enzyme-immunoassay. Thromb Res: 2011; 128 3 256 260
    • (2011) Thromb Res , vol.128 , Issue.3 , pp. 256-260
    • Althaus, K.1    Strobel, U.2    Warkentin, T.E.3    Greinacher, A.4
  • 49
    • 0022640930 scopus 로고
    • A Diagnostic test for heparin-induced thrombocytopenia
    • Sheridan D, Carter C, Kelton JG. A diagnostic test for heparin-induced thrombocytopenia. Blood: 1986; 67 1 27 30 (Pubitemid 16167006)
    • (1986) Blood , vol.67 , Issue.1 , pp. 27-30
    • Sheridan, D.1    Carter, C.2    Kelton, J.G.3
  • 50
    • 0025951938 scopus 로고
    • A rapid and sensitive test for diagnosing heparin-associated thrombocytopenia
    • Greinacher A, Michels I, Kiefel V, Mueller-Eckhardt C. A rapid and sensitive test for diagnosing heparin-associated thrombocytopenia. Thromb Haemost: 1991; 66 6 734 736
    • (1991) Thromb Haemost , vol.66 , Issue.6 , pp. 734-736
    • Greinacher, A.1    Michels, I.2    Kiefel, V.3    Mueller-Eckhardt, C.4
  • 52
    • 0024321104 scopus 로고
    • Activation of monocytes and platelets by monoclonal antibodies or malaria-infected erythrocytes binding to the CD36 surface receptor in vitro
    • Ockenhouse CF, Magowan C, Chulay JD. Activation of monocytes and platelets by monoclonal antibodies or malaria-infected erythrocytes binding to the CD36 surface receptor in vitro. J Clin Invest: 1989; 84 2 468 475 (Pubitemid 19196977)
    • (1989) Journal of Clinical Investigation , vol.84 , Issue.2 , pp. 468-475
    • Ockenhouse, C.F.1    Magowan, C.2    Chulay, J.D.3
  • 53
    • 0025038080 scopus 로고
    • Platelet activation by CD9 monoclonal antibodies is mediated by the F(c)II receptor
    • Worthington RE, Carroll RC, Boucheix C. Platelet activation by CD9 monoclonal antibodies is mediated by the Fc gamma II receptor. Br J Haematol: 1990; 74 2 216 222 (Pubitemid 20041098)
    • (1990) British Journal of Haematology , vol.74 , Issue.2 , pp. 216-222
    • Worthington, R.E.1    Carroll, R.C.2    Boucheix, C.3
  • 55
    • 0025895339 scopus 로고
    • A single amino acid distinguishes the high-responder from the low-responder form of Fc receptor II on human monocytes
    • Clark MR, Stuart SG, Kimberly RP, Ory PA, Goldstein IM. A single amino acid distinguishes the high-responder from the low-responder form of Fc receptor II on human monocytes. Eur J Immunol: 1991; 21 8 1911 1916
    • (1991) Eur J Immunol , vol.21 , Issue.8 , pp. 1911-1916
    • Clark, M.R.1    Stuart, S.G.2    Kimberly, R.P.3    Ory, P.A.4    Goldstein, I.M.5
  • 56
    • 0026795859 scopus 로고
    • Response of human platelets to activating monoclonal antibodies: Importance of Fc gamma RII (CD32) phenotype and level of expression
    • Tomiyama Y, Kunicki TJ, Zipf TF, Ford SB, Aster RH. Response of human platelets to activating monoclonal antibodies: importance of Fc gamma RII (CD32) phenotype and level of expression. Blood: 1992; 80 9 2261 2268
    • (1992) Blood , vol.80 , Issue.9 , pp. 2261-2268
    • Tomiyama, Y.1    Kunicki, T.J.2    Zipf, T.F.3    Ford, S.B.4    Aster, R.H.5
  • 58
  • 59
    • 77949491627 scopus 로고    scopus 로고
    • Whole blood impedance aggregometry detects heparin-induced thrombocytopenia antibodies
    • Morel-Kopp MC, Aboud M, Tan CW, Kulathilake C, Ward C. Whole blood impedance aggregometry detects heparin-induced thrombocytopenia antibodies. Thromb Res: 2010; 125 5 e234 e239
    • (2010) Thromb Res , vol.125 , Issue.5
    • Morel-Kopp, M.C.1    Aboud, M.2    Tan, C.W.3    Kulathilake, C.4    Ward, C.5
  • 60
    • 36949007618 scopus 로고    scopus 로고
    • Laboratory testing for heparin-induced thrombocytopenia is inconsistent in North America: A survey of North American specialized coagulation laboratories
    • DOI 10.1160/TH07-06-0401
    • Price EA, Hayward CP, Moffat KA, Moore JC, Warkentin TE, Zehnder JL. Laboratory testing for heparin-induced thrombocytopenia is inconsistent in North America: a survey of North American specialized coagulation laboratories. Thromb Haemost: 2007; 98 6 1357 1361 (Pubitemid 350239110)
    • (2007) Thrombosis and Haemostasis , vol.98 , Issue.6 , pp. 1357-1361
    • Price, E.A.1    Hayward, C.P.M.2    Moffat, K.A.3    Moore, J.C.4    Warkentin, T.E.5    Zehnder, J.L.6
  • 61
    • 69249213606 scopus 로고    scopus 로고
    • Thrombin generation and heparin-induced thrombocytopenia
    • Tardy-Poncet B, Piot M, Chapelle C., et al. Thrombin generation and heparin-induced thrombocytopenia. J Thromb Haemost: 2009; 7 9 1474 1481
    • (2009) J Thromb Haemost , vol.7 , Issue.9 , pp. 1474-1481
    • Tardy-Poncet, B.1    Piot, M.2    Chapelle, C.3
  • 62
    • 70449572934 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia (HIT II) - A drug-associated autoimmune disease
    • Nowak G. Heparin-induced thrombocytopenia (HIT II) - a drug-associated autoimmune disease. Thromb Haemost: 2009; 102 5 887 891
    • (2009) Thromb Haemost , vol.102 , Issue.5 , pp. 887-891
    • Nowak, G.1
  • 63
    • 0016668496 scopus 로고
    • Heparin-induced thrombocytopenia: Confirmation of diagnosis with in vitro methods
    • Fratantoni JC, Pollet R, Gralnick HR. Heparin-induced thrombocytopenia: confirmation of diagnosis with in vitro methods. Blood: 1975; 45 3 395 401
    • (1975) Blood , vol.45 , Issue.3 , pp. 395-401
    • Fratantoni, J.C.1    Pollet, R.2    Gralnick, H.R.3
  • 64
    • 0020404337 scopus 로고
    • Heparin-induced thrombocytopenia: Association of thrombotic complications with heparin-dependent IgG antibody that induces thromboxane synthesis in platelet aggregation
    • Chong BH, Pitney WR, Castaldi PA. Heparin-induced thrombocytopenia: association of thrombotic complications with heparin-dependent IgG antibody that induces thromboxane synthesis in platelet aggregation. Lancet: 1982; 2 8310 1246 1249
    • (1982) Lancet , vol.2 , Issue.8310 , pp. 1246-1249
    • Chong, B.H.1    Pitney, W.R.2    Castaldi, P.A.3
  • 65
    • 0031792073 scopus 로고    scopus 로고
    • Progress in point-of-care laboratory testing for assessing platelet function
    • DOI 10.1053/hj.1998.v136.93432
    • Berkowitz SD, Frelinger AL III, Hillman RS. Progress in point-of-care laboratory testing for assessing platelet function. Am Heart J: 1998; 136 4 Pt 2 Su S51 S65 (Pubitemid 28487159)
    • (1998) American Heart Journal , vol.136 , Issue.SUPPL. 4
    • Berkowitz, S.D.1    Frelinger III, A.L.2    Hillman, R.S.3
  • 66
    • 10444228879 scopus 로고    scopus 로고
    • Platelet function analysis
    • DOI 10.1016/j.blre.2004.05.002, PII S0268960X04000311
    • Harrison P. Platelet function analysis. Blood Rev: 2005; 19 2 111 123 (Pubitemid 39643116)
    • (2005) Blood Reviews , vol.19 , Issue.2 , pp. 111-123
    • Harrison, P.1
  • 70
    • 70449431458 scopus 로고    scopus 로고
    • Heparin-induced multiple electrode aggregometry: A potential tool for improvement of heparin-induced thrombocytopenia diagnosis
    • Elalamy I, Galea V, Hatmi M, Gerotziafas GT. Heparin-induced multiple electrode aggregometry: a potential tool for improvement of heparin-induced thrombocytopenia diagnosis. J Thromb Haemost: 2009; 7 11 1932 1934
    • (2009) J Thromb Haemost , vol.7 , Issue.11 , pp. 1932-1934
    • Elalamy, I.1    Galea, V.2    Hatmi, M.3    Gerotziafas, G.T.4
  • 71
    • 0034971216 scopus 로고    scopus 로고
    • A new approach in the study of the molecular and cellular events implicated in heparin-induced thrombocytopenia: Formation of leukocyte-platelet aggregates
    • Khairy M, Lasne D, Brohard-Bohn B, Aiach M, Rendu F, Bachelot-Loza C. A new approach in the study of the molecular and cellular events implicated in heparin-induced thrombocytopenia. Formation of leukocyte-platelet aggregates. Thromb Haemost: 2001; 85 6 1090 1096 (Pubitemid 32573765)
    • (2001) Thrombosis and Haemostasis , vol.85 , Issue.6 , pp. 1090-1096
    • Khairy, M.1    Lasne, D.2    Brohard-Bohn, B.3    Aiach, M.4    Rendu, F.5    Bachelot-Loza, C.6
  • 72
    • 0032834309 scopus 로고    scopus 로고
    • Generation of platelet-derived microparticles and procoagulant activity by heparin-induced thrombocytopenia IgG/serum and other IgG platelet agonists: A comparison with standard platelet agonists
    • DOI 10.1080/09537109975960
    • Warkentin TE, Sheppard JI. Generation of platelet-derived microparticles and procoagulant activity by heparin-induced thrombocytopenia IgG/serum and other IgG platelet agonists: a comparison with standard platelet agonists. Platelets: 1999; 10 5 319 326 (Pubitemid 29490859)
    • (1999) Platelets , vol.10 , Issue.5 , pp. 319-326
    • Warkentin, T.E.1    Sheppard, J.I.2
  • 73
    • 77953175241 scopus 로고    scopus 로고
    • Contribution of platelet microparticles generation assay to the diagnosis of type II heparin-induced thrombocytopenia
    • Mullier F, Bailly N, Cornet Y., et al. Contribution of platelet microparticles generation assay to the diagnosis of type II heparin-induced thrombocytopenia. Thromb Haemost: 2010; 103 6 1277 1281
    • (2010) Thromb Haemost , vol.103 , Issue.6 , pp. 1277-1281
    • Mullier, F.1    Bailly, N.2    Cornet, Y.3
  • 74
    • 0032863073 scopus 로고    scopus 로고
    • A flow cytometric assay of platelet activation marker P-selectin (CD62P) distinguishes heparin-induced thrombocytopenia (HIT) from HIT with thrombosis (HITT)
    • Jy W, Mao WW, Horstman LL, Valant PA, Ahn YS. A flow cytometric assay of platelet activation marker P-selectin (CD62P) distinguishes heparin-induced thrombocytopenia (HIT) from HIT with thrombosis (HITT). Thromb Haemost: 1999; 82 4 1255 1259 (Pubitemid 29473788)
    • (1999) Thrombosis and Haemostasis , vol.82 , Issue.4 , pp. 1255-1259
    • Jy, W.1    Mao, W.W.2    Horstman, L.L.3    Valant, P.A.4    Ahn, Y.S.5
  • 75
    • 0030964597 scopus 로고    scopus 로고
    • A sensitive and specific functional flow cytometric assay for the diagnosis of heparin-induced thrombocytopenia
    • Tomer A. A sensitive and specific functional flow cytometric assay for the diagnosis of heparin-induced thrombocytopenia. Br J Haematol: 1997; 98 3 648 656 (Pubitemid 27386546)
    • (1997) British Journal of Haematology , vol.98 , Issue.3 , pp. 648-656
    • Tomer, A.1
  • 77
    • 28444447972 scopus 로고    scopus 로고
    • Activation of platelets by heparin-induced thrombocytopenia antibodies in the serotonin release assay is not dependent on the presence of heparin
    • DOI 10.1111/j.1538-7836.2005.01560.x
    • Prechel MM, McDonald MK, Jeske WP, Messmore HL, Walenga JM. Activation of platelets by heparin-induced thrombocytopenia antibodies in the serotonin release assay is not dependent on the presence of heparin. J Thromb Haemost: 2005; 3 10 2168 2175 (Pubitemid 41727193)
    • (2005) Journal of Thrombosis and Haemostasis , vol.3 , Issue.10 , pp. 2168-2175
    • Prechel, M.M.1    Mcdonald, M.K.2    Jeske, W.P.3    Messmore, H.L.4    Walenga, J.M.5
  • 78
    • 37549049381 scopus 로고    scopus 로고
    • Heparin-independent activation of platelets by heparin-induced thrombocytopenia antibodies: A common occurrence
    • Socher I, Kroll H, Jorks S, Santoso S, Sachs UJ. Heparin-independent activation of platelets by heparin-induced thrombocytopenia antibodies: a common occurrence. J Thromb Haemost: 2008; 6 1 197 200
    • (2008) J Thromb Haemost , vol.6 , Issue.1 , pp. 197-200
    • Socher, I.1    Kroll, H.2    Jorks, S.3    Santoso, S.4    Sachs, U.J.5
  • 79
    • 27144527501 scopus 로고    scopus 로고
    • Risk for heparin-induced thrombocytopenia with unfractionated and low-molecular-weight heparin thromboprophylaxis: A meta-analysis
    • DOI 10.1182/blood-2005-04-1546
    • Martel N, Lee J, Wells PS. Risk for heparin-induced thrombocytopenia with unfractionated and low-molecular-weight heparin thromboprophylaxis: a meta-analysis. Blood: 2005; 106 8 2710 2715 (Pubitemid 41510744)
    • (2005) Blood , vol.106 , Issue.8 , pp. 2710-2715
    • Martel, N.1    Lee, J.2    Wells, P.S.3
  • 80
    • 0026586819 scopus 로고
    • An enzyme-linked immunosorbent assay for heparin cofactor II (HCII). Application to the measurement of HCII in clinical materials
    • Toulon P, Costa JM, Amiral J. An enzyme-linked immunosorbent assay for heparin cofactor II (HCII). Application to the measurement of HCII in clinical materials. Clin Chim Acta: 1992; 205 1-2 65 73
    • (1992) Clin Chim Acta , vol.205 , Issue.12 , pp. 65-73
    • Toulon, P.1    Costa, J.M.2    Amiral, J.3
  • 81
    • 12244290314 scopus 로고    scopus 로고
    • A differentiated approach to assess the diagnostic usefulness of a rapid particle gel immunoassay for the detection of antibodies against heparin-platelet factor 4 in cardiac surgery patients
    • DOI 10.1097/00001721-200301000-00018
    • Risch L, Bertschmann W, Heijnen IA, Huber AR. A differentiated approach to assess the diagnostic usefulness of a rapid particle gel immunoassay for the detection of antibodies against heparin-platelet factor 4 in cardiac surgery patients. Blood Coagul Fibrinolysis: 2003; 14 1 99 106 (Pubitemid 36206731)
    • (2003) Blood Coagulation and Fibrinolysis , vol.14 , Issue.1 , pp. 99-106
    • Risch, L.1    Bertschmann, W.2    Heijnen, I.A.F.M.3    Huber, A.R.4
  • 82
    • 84857746149 scopus 로고    scopus 로고
    • Validation of whole blood impedance aggregometry as a new diagnostic tool for HIT. Results of a large Australian Study
    • [Epub ahead of print]
    • Morel-Kopp MC, Tan CW, Brighton TA., et al. Validation of whole blood impedance aggregometry as a new diagnostic tool for HIT. Results of a large Australian Study. Thromb Haemost: 2012; 107 3 [Epub ahead of print]
    • (2012) Thromb Haemost , vol.107 , Issue.3
    • Morel-Kopp, M.C.1    Tan, C.W.2    Brighton, T.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.