메뉴 건너뛰기




Volumn 58, Issue 1, 2004, Pages 32-38

New Laboratory Test in Flow Cytometry for the Combined Analysis of Serologic and Cellular Parameters in the Diagnosis of Heparin-Induced Thrombocytopenia

Author keywords

Annexin V; Flow cytometry; Heparin induced thrombocytopenia; Particle gel immunoassay; Platelet factor 4

Indexed keywords

HEPARIN; LIPOCORTIN 5; THROMBOCYTE FACTOR 4;

EID: 12144291517     PISSN: 15524949     EISSN: None     Source Type: Journal    
DOI: 10.1002/cyto.b.10062     Document Type: Article
Times cited : (28)

References (26)
  • 2
    • 0036213008 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia: An overview
    • Kelton JG. Heparin-induced thrombocytopenia: an overview. Blood Rev 2002;16:77-80.
    • (2002) Blood Rev , vol.16 , pp. 77-80
    • Kelton, J.G.1
  • 3
    • 0028009642 scopus 로고
    • Antibodies from patients with heparin-induced thrombocytopenia/ thrombosis are specific for platelet factor 4 complexed with heparin or bound to endothelial cells
    • Visentin GP, Ford SE, Scott JP, Aster RH. Antibodies from patients with heparin-induced thrombocytopenia/thrombosis are specific for platelet factor 4 complexed with heparin or bound to endothelial cells. J Clin Invest 1994;93:81-88.
    • (1994) J Clin Invest , vol.93 , pp. 81-88
    • Visentin, G.P.1    Ford, S.E.2    Scott, J.P.3    Aster, R.H.4
  • 4
    • 0024357798 scopus 로고
    • Heparin-induced thrombocytopenia: Mechanism of interaction of the heparin-dependent antibody with platelets
    • Chong BH, Fawaz I, Chesterman CN, Berndt MC. Heparin-induced thrombocytopenia: mechanism of interaction of the heparin-dependent antibody with platelets. Br J Haematol 1989;73:235-240.
    • (1989) Br J Haematol , vol.73 , pp. 235-240
    • Chong, B.H.1    Fawaz, I.2    Chesterman, C.N.3    Berndt, M.C.4
  • 5
    • 0002353110 scopus 로고    scopus 로고
    • Laboratory testing for heparin-induced thrombocytopenia
    • Warkentin TE, Greinaker A, editors. New York: Marcel Dekker
    • Warkentin TE, Greinaker A. Laboratory testing for heparin-induced thrombocytopenia. In: Warkentin TE, Greinaker A, editors. Heparin-induced thrombocytopenia. 2nd ed. New York: Marcel Dekker; 2001. p 234-270.
    • (2001) Heparin-induced Thrombocytopenia. 2nd Ed. , pp. 234-270
    • Warkentin, T.E.1    Greinaker, A.2
  • 6
    • 0033730964 scopus 로고    scopus 로고
    • Pathophysiology of heparin-induced thrombocytopenia. Clinical and diagnostic implications - A review
    • Fabris F, Ahmad S, Cella G, Jeske WP, Walenga JM, Fareed J. Pathophysiology of heparin-induced thrombocytopenia. Clinical and diagnostic implications - a review. Arch Pathol Lab Med 2000;124:1657-1666.
    • (2000) Arch Pathol Lab Med , vol.124 , pp. 1657-1666
    • Fabris, F.1    Ahmad, S.2    Cella, G.3    Jeske, W.P.4    Walenga, J.M.5    Fareed, J.6
  • 7
    • 0036118897 scopus 로고    scopus 로고
    • The new ID-heparin/PF4 antibody test for rapid detection of heparin-induced antibodies in comparison with functional and antigenic assays
    • Eichler P, Raschke R, Lubenow N, Meyer O, Schwind P, Greinacher A. The new ID-heparin/PF4 antibody test for rapid detection of heparin-induced antibodies in comparison with functional and antigenic assays. Br J Haematol 2002;116:887-891.
    • (2002) Br J Haematol , vol.116 , pp. 887-891
    • Eichler, P.1    Raschke, R.2    Lubenow, N.3    Meyer, O.4    Schwind, P.5    Greinacher, A.6
  • 8
    • 0038657918 scopus 로고    scopus 로고
    • The pathophysiology of immune-mediated heparin-induced thrombocytopenia
    • Reilly RF. The pathophysiology of immune-mediated heparin-induced thrombocytopenia. Semin Dial 2003;16:54-60.
    • (2003) Semin Dial , vol.16 , pp. 54-60
    • Reilly, R.F.1
  • 9
    • 0027175541 scopus 로고
    • Annexin V as a probe of aminophospholipid exposure and platelet membrane vesiculation: A flow cytometry study showing a role for free sulfhydryl groups
    • Dachary-Prigent J, Freyssinet JM, Pasquet JM, Carron JC, Nurden AT. Annexin V as a probe of aminophospholipid exposure and platelet membrane vesiculation: a flow cytometry study showing a role for free sulfhydryl groups. Blood 1993;81:2554-2565.
    • (1993) Blood , vol.81 , pp. 2554-2565
    • Dachary-Prigent, J.1    Freyssinet, J.M.2    Pasquet, J.M.3    Carron, J.C.4    Nurden, A.T.5
  • 10
    • 0030964597 scopus 로고    scopus 로고
    • A sensitive and specific functional flow cytometric assay for the diagnosis of heparin-induced thrombocytopenia
    • Tomer A. A sensitive and specific functional flow cytometric assay for the diagnosis of heparin-induced thrombocytopenia. Br J Haematol 1997;98:648-656.
    • (1997) Br J Haematol , vol.98 , pp. 648-656
    • Tomer, A.1
  • 12
    • 0038446690 scopus 로고    scopus 로고
    • Aspects of hydrodynamic shear regulating shear-induced platelet activation and self-association of von Willebrand factor in suspension
    • Shankaran H, Alexandridis P, Neelamegham S. Aspects of hydrodynamic shear regulating shear-induced platelet activation and self-association of von Willebrand factor in suspension. Blood 2003;101:2637-2645.
    • (2003) Blood , vol.101 , pp. 2637-2645
    • Shankaran, H.1    Alexandridis, P.2    Neelamegham, S.3
  • 13
    • 0033619470 scopus 로고    scopus 로고
    • Rapid detection of heparin-induced platelet antibodies using the new particle gel immuno assay (ID-HPF4)
    • Meyer O, Salama A, Pittet N, Schwind P. Rapid detection of heparin-induced platelet antibodies using the new particle gel immuno assay (ID-HPF4). Lancet 1999;354:1525-1526.
    • (1999) Lancet , vol.354 , pp. 1525-1526
    • Meyer, O.1    Salama, A.2    Pittet, N.3    Schwind, P.4
  • 14
    • 0036086107 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia: Detection of antiheparin/PF4 antibodies by means of heparin/PF4-coated beads and flow cytometry
    • Tazzari PL, Ricci F, Vitale M, Malferrari F, Salama A, Schwind P, Conte R. Heparin-induced thrombocytopenia: detection of antiheparin/PF4 antibodies by means of heparin/PF4-coated beads and flow cytometry. Transfus Med 2002;12:193-198.
    • (2002) Transfus Med , vol.12 , pp. 193-198
    • Tazzari, P.L.1    Ricci, F.2    Vitale, M.3    Malferrari, F.4    Salama, A.5    Schwind, P.6    Conte, R.7
  • 17
    • 85047688615 scopus 로고    scopus 로고
    • Clinical significance of a borderline titer in a negative ELISA test for heparin-induced thrombocytopenia
    • Refaai MA, Laposata M, Van Cott EM. Clinical significance of a borderline titer in a negative ELISA test for heparin-induced thrombocytopenia. Am J Clin Pathol 2003;119:61-65.
    • (2003) Am J Clin Pathol , vol.119 , pp. 61-65
    • Refaai, M.A.1    Laposata, M.2    Van Cott, E.M.3
  • 19
    • 0032923425 scopus 로고    scopus 로고
    • First workshop for detection of heparin-induced antibodies: Validation of the heparin-induced platelet-activation test (HIPA) in comparison with a PF4/heparin ELISA
    • Eichler P, Budde U, Haas S, Kroll H, Loreth RM, Meyer O, Pachmann U, Potzsch B, Schabel A, Albrecht D, Greinacher A. First workshop for detection of heparin-induced antibodies: validation of the heparin-induced platelet-activation test (HIPA) in comparison with a PF4/heparin ELISA. Thromb Haemost 1999;81:625-629.
    • (1999) Thromb Haemost , vol.81 , pp. 625-629
    • Eichler, P.1    Budde, U.2    Haas, S.3    Kroll, H.4    Loreth, R.M.5    Meyer, O.6    Pachmann, U.7    Potzsch, B.8    Schabel, A.9    Albrecht, D.10    Greinacher, A.11
  • 20
    • 0028335456 scopus 로고
    • Laboratory diagnosis of heparin-associated thrombocytopenia and comparison of platelet aggregation test, heparin-induced platelet activation test, and platelet factor 4/heparin enzyme-linked immunosorbent assay
    • Greinacher A, Amiral J, Dummel V, Vissac A, Kiefel V, Mueller-Eckhardt C. Laboratory diagnosis of heparin-associated thrombocytopenia and comparison of platelet aggregation test, heparin-induced platelet activation test, and platelet factor 4/heparin enzyme-linked immunosorbent assay. Transfusion 1994;34:381-385.
    • (1994) Transfusion , vol.34 , pp. 381-385
    • Greinacher, A.1    Amiral, J.2    Dummel, V.3    Vissac, A.4    Kiefel, V.5    Mueller-Eckhardt, C.6
  • 21
    • 0029022130 scopus 로고
    • Comparison between platelet factor 4/heparin complexes ELISA and platelet aggregation test in heparin-induced thrombocytopenia
    • Nguyen P, Droulle C, Potron G. Comparison between platelet factor 4/heparin complexes ELISA and platelet aggregation test in heparin-induced thrombocytopenia. Thromb Haemost 1995;74:804-805.
    • (1995) Thromb Haemost , vol.74 , pp. 804-805
    • Nguyen, P.1    Droulle, C.2    Potron, G.3
  • 23
    • 0032946370 scopus 로고    scopus 로고
    • Determination of heparin-induced thrombocytopenia: A rapid flow cytometric assay for direct demonstration of antibody-mediated platelet activation
    • Tomer A, Masalunga C, Abshire TC. Determination of heparin-induced thrombocytopenia: a rapid flow cytometric assay for direct demonstration of antibody-mediated platelet activation. Am J Hematol 1999;61:53-61.
    • (1999) Am J Hematol , vol.61 , pp. 53-61
    • Tomer, A.1    Masalunga, C.2    Abshire, T.C.3
  • 24
    • 0032863073 scopus 로고    scopus 로고
    • A flow cytometric assay of platelet activation marker P-selectin (CD62P) distinguishes heparin-induced thrombocytopenia (HIT) from HIT with thrombosis (HITT)
    • Jy W, Mao WW, Horstman LL, Valant PA, Ahn YS. A flow cytometric assay of platelet activation marker P-selectin (CD62P) distinguishes heparin-induced thrombocytopenia (HIT) from HIT with thrombosis (HITT). Thromb Haemost 1999;82:1255-1259.
    • (1999) Thromb Haemost , vol.82 , pp. 1255-1259
    • Jy, W.1    Mao, W.W.2    Horstman, L.L.3    Valant, P.A.4    Ahn, Y.S.5
  • 25
    • 0035010754 scopus 로고    scopus 로고
    • Laboratory diagnosis of heparin-induced thrombocytopenia: Advantages of a functional flow cytometric test in comparison to the heparin-induced platelet-activation test
    • Poley S, Mempel W. Laboratory diagnosis of heparin-induced thrombocytopenia: advantages of a functional flow cytometric test in comparison to the heparin-induced platelet-activation test. Eur J Haematol 2001;66:253-262.
    • (2001) Eur J Haematol , vol.66 , pp. 253-262
    • Poley, S.1    Mempel, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.