메뉴 건너뛰기




Volumn 7, Issue 1, 2012, Pages 13-25

Accuracy considerations in image-guided cardiac interventions: Experience and lessons learned

Author keywords

Clinical and engineering accuracy considerations; Medical imaging and modeling; Minimally invasive cardiac interventions; Registration; Surgical tracking

Indexed keywords

ABLATION THERAPY; ACCURACY; ARTICLE; AUTOMATION; CARDIAC IMAGING; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CORONARY ARTERY BYPASS GRAFT; CRYOABLATION; ECHOGRAPHY; FLUOROSCOPY; HEART ATRIUM SEPTUM DEFECT; HUMAN; INTERVENTIONAL CARDIOVASCULAR PROCEDURE; MITRAL VALVE REPLACEMENT; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PREOPERATIVE PERIOD; PRIORITY JOURNAL; RADIOFREQUENCY ABLATION; ROBOTICS; SURGICAL EQUIPMENT; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; ULTRASOUND TRANSDUCER;

EID: 84857623933     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-011-0621-1     Document Type: Article
Times cited : (26)

References (50)
  • 1
    • 77955639984 scopus 로고    scopus 로고
    • Image-guided interventions: Technology review and applications
    • Cleary K, Peters TM (2010) Image-guided interventions: technology review and applications. Annu Rev Biomed Eng 12:119-142
    • (2010) Annu Rev Biomed Eng , vol.12 , pp. 119-142
    • Cleary, K.1    Peters, T.M.2
  • 3
    • 78650397347 scopus 로고    scopus 로고
    • Overview and history of imageguided interventions
    • Peters TM, Cleary K (eds), Springer, Heidelberg
    • Galloway R, Peters TM (2008) Overview and history of imageguided interventions. In: Peters TM, Cleary K (eds) Image-guided interventions: technology and applications. Springer, Heidelberg pp 1-21
    • (2008) Image-guided Interventions: Technology and Applications. , pp. 1-21
    • Galloway, R.1    Peters, T.M.2
  • 5
    • 0035220947 scopus 로고    scopus 로고
    • The development of an evaluation framework for the quantitative assessment of computer-assisted surgery and augmented reality accuracy performance
    • Medicine Meets Virtual Reality 2001 Outer Space, Inner Space, Virtual Space
    • ViantWJ (2001) The development of an evaluation framework for the quantitative assessment of computer-assisted surgery and augmented reality accuracy performance. Stud Health Technol Inform 81:534-540 (Pubitemid 33320124)
    • (2001) Stud Health Technol Inform , Issue.81 , pp. 534-540
    • Viant, W.J.1
  • 6
    • 40149089412 scopus 로고    scopus 로고
    • Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions
    • DOI 10.1080/10929080801951160, PII 791127610, MMVR15
    • Linte CA, Moore J, Wiles A, Wedlake C, Peters T (2008) Virtual reality-enhanced ultrasound guidance: a novel technique for intracardiac interventions. Comput Aided Surg 13:82-94 (Pubitemid 351329016)
    • (2008) Computer Aided Surgery , vol.13 , Issue.2 , pp. 82-94
    • Linte, C.A.1    Moore, J.2    Wiles, A.D.3    Wedlake, C.4    Peters, T.M.5
  • 7
    • 33846907207 scopus 로고    scopus 로고
    • Image registration: Enabling technology for image guided surgery and therapy
    • 1616182, Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
    • Sauer F (2005) Image registration: enabling technology for imageguided surgery and therapy. In: Proceedings of IEEE engineering in medicine and biology society, pp 7242-7245 (Pubitemid 46230654)
    • (2005) Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings , vol.7 , pp. 7242-7245
    • Sauer, F.1
  • 8
    • 67349086267 scopus 로고    scopus 로고
    • An event-driven distributed processing architecture for image-guided cardiac ablation therapy
    • Rettmann ME, Holmes III DR, Cameron B, Robb RA (2009) An event-driven distributed processing architecture for image-guided cardiac ablation therapy. Comput Methods Programs Biomed 95:95-104
    • (2009) Comput Methods Programs Biomed , vol.95 , pp. 95-104
    • Rettmann, M.E.1    Holmes Iii, D.R.2    Cameron, B.3    Robb, R.A.4
  • 11
    • 70349784430 scopus 로고    scopus 로고
    • Echocardiography to magnetic resonance image registration for use in image-guided cardiac catheterization procedures
    • Ma YL, Penney GP, Rinaldi CA, Cooklin M, Razavi R, Rhode KS (2009) Echocardiography to magnetic resonance image registration for use in image-guided cardiac catheterization procedures. Phys Med Biol 54:5039-5055
    • (2009) Phys Med Biol , vol.54 , pp. 5039-5055
    • Ma, Y.L.1    Penney, G.P.2    Rinaldi, C.A.3    Cooklin, M.4    Razavi, R.5    Rhode, K.S.6
  • 12
    • 34548127006 scopus 로고    scopus 로고
    • Robotics in cardiac surgery: The emperor's new clothes
    • DOI 10.1016/j.jtcvs.2006.08.026, PII S0022522306014826
    • Damiano RJ Jr (2007) Robotics in cardiac surgery: The emperor's new clothes. J Thorac Cardiovasc Surg 134:559-561 (Pubitemid 47301945)
    • (2007) Journal of Thoracic and Cardiovascular Surgery , vol.134 , Issue.3 , pp. 559-561
    • Damiano Jr., R.J.1
  • 18
    • 4444220818 scopus 로고    scopus 로고
    • Validation of dynamic heart models obtained using non-linear registration for virtual reality training, planning, and guidance of minimally invasive cardiac surgeries
    • DOI 10.1016/j.media.2004.06.014, PII S1361841504000386
    • Wierzbicki M, Drangova M, Guiraudon GM, Peters TM (2004) Validation of dynamic heart models obtained using non-linear registration for virtual reality training, planning, and guidance of minimally invasive cardiac surgeries. Med Image Anal. 8:387-401 (Pubitemid 39185920)
    • (2004) Medical Image Analysis , vol.8 , Issue.3 , pp. 387-401
    • Wierzbicki, M.1    Drangova, M.2    Guiraudon, G.3    Peters, T.4
  • 20
  • 22
    • 77749264352 scopus 로고    scopus 로고
    • Segmentation of the left ventricle from cardiac MR images using a subjectspecific dynamical model
    • Zhu X, Papademetris X, Sinusas AJ, Duncan JS (2010) Segmentation of the left ventricle from cardiac MR images using a subjectspecific dynamical model. IEEE Trans Med Imaging 29:669-687
    • (2010) IEEE Trans Med Imaging , vol.29 , pp. 669-687
    • Zhu, X.1    Papademetris, X.2    Sinusas, A.J.3    Duncan, J.S.4
  • 26
    • 0000250265 scopus 로고
    • Measures of the amount of ecologic association between species
    • Dice L (1945) Measures of the amount of ecologic association between species. Ecology 26:297-302
    • (1945) Ecology , vol.26 , pp. 297-302
    • Dice, L.1
  • 29
    • 0043175141 scopus 로고    scopus 로고
    • Accuracy assessment protocols for electromagnetic tracking systems
    • DOI 10.1088/0031-9155/48/14/314, PII S0031915503618063
    • Frantz DD,WilesAD, Leis SE,Kirsch SR (2003) Accuracy assessment protocols for electromagnetic tracking systems. Phys Med Biol 48:2241-2251 (Pubitemid 36926711)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.14 , pp. 2241-2251
    • Frantz, D.D.1    Wiles, A.D.2    Leis, S.E.3    Kirsch, S.R.4
  • 37
    • 67349214041 scopus 로고    scopus 로고
    • Inside the beating heart: An in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy
    • Linte CA, Moore J, Wedlake C, Bainbridge D, Guitaudon GM, Jones DL, Peters TM (2009) Inside the beating heart: an in vivo feasibility study on fusing pre- and intra-operative imaging for minimally invasive therapy. Int J CARS 4:113-122
    • (2009) Int J CARS , vol.4 , pp. 113-122
    • Linte, C.A.1    Moore, J.2    Wedlake, C.3    Bainbridge, D.4    Guitaudon, G.M.5    Jones, D.L.6    Peters, T.M.7
  • 41
    • 77955936299 scopus 로고    scopus 로고
    • Evaluation of modelenhanced ultrasound-assisted interventional guidance in a cardiac phantom
    • Linte CA, Moore J, Wedlake CMPT (2010) Evaluation of modelenhanced ultrasound-assisted interventional guidance in a cardiac phantom. IEEE Trans Biomed Eng 57:2209-2218
    • (2010) IEEE Trans Biomed Eng , vol.57 , pp. 2209-2218
    • Linte, C.A.1    Moore, J.2    Wedlake, C.M.P.T.3
  • 49
    • 40149095934 scopus 로고    scopus 로고
    • A statistical model for point-based target registration error with anisotropic fiducial localizer error
    • DOI 10.1109/TMI.2007.908124, 4359067
    • Wiles AD, Likholyot A, Frantz DD, Peters TM (2008) A statistical model for point-based target registration error with anisotropic fiducial localizer error. IEEE Trans Med Imaging 27:378-390 (Pubitemid 351324786)
    • (2008) IEEE Transactions on Medical Imaging , vol.27 , Issue.3 , pp. 378-390
    • Wiles, A.D.1    Likholyot, A.2    Frantz, D.D.3    Peters, T.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.