메뉴 건너뛰기




Volumn 6918, Issue , 2008, Pages

Object identification accuracy under ultrasound enhanced virtual reality for minimally invasive cardiac surgery

Author keywords

Calibration; Cardiac procedures; Enhanced reality; Image guided therapy; Intraoperative imaging; Localization and tracking technologies; Ultrasound guidance; Validation

Indexed keywords

ACOUSTIC WAVES; CALIBRATION; COMPUTER NETWORKS; ELECTRONIC GUIDANCE SYSTEMS; IMAGING TECHNIQUES; NETWORK PROTOCOLS; REMOTE CONTROL; SURGERY; TRANSPLANTATION (SURGICAL); ULTRASONIC IMAGING; ULTRASONIC TRANSDUCERS; ULTRASONIC TRANSMISSION; ULTRASONICS; VIRTUAL REALITY; VISUALIZATION;

EID: 40149098518     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.773178     Document Type: Conference Paper
Times cited : (14)

References (18)
  • 1
    • 33745842108 scopus 로고    scopus 로고
    • Universal cardiac introducer
    • Patent Application, June, US 2005/0137609 Al, Appl. No. 10/736, 786
    • G. M. Guiraudon, "Universal cardiac introducer." Patent Application, June 2005. US 2005/0137609 Al, Appl. No. 10/736, 786.
    • (2005)
    • Guiraudon, G.M.1
  • 3
    • 34848901353 scopus 로고    scopus 로고
    • Mitral valve implantation using off-pump closed beating intracardiac surgery: A feasibility study
    • Oct
    • G. M. Guiraudon, D. L. Jones, D. Bainbridge, and T. M. Peters, "Mitral valve implantation using off-pump closed beating intracardiac surgery: A feasibility study.," Interact Cardiovasc Thome Surg 6, pp. 603-607, Oct 2007.
    • (2007) Interact Cardiovasc Thome Surg , vol.6 , pp. 603-607
    • Guiraudon, G.M.1    Jones, D.L.2    Bainbridge, D.3    Peters, T.M.4
  • 5
    • 40149089412 scopus 로고    scopus 로고
    • Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions
    • In Press
    • C. A. Linte, J. Moore, A. D. Wiles, C. Wedlake, and T. M. Peters, "Virtual reality-enhanced ultrasound guidance: A novel technique for intracardiac interventions," Computer Aided Surgery, 2008. In Press.
    • (2008) Computer Aided Surgery
    • Linte, C.A.1    Moore, J.2    Wiles, A.D.3    Wedlake, C.4    Peters, T.M.5
  • 8
    • 33750815385 scopus 로고    scopus 로고
    • Quantitative evaluation of three calibration methods for 3-D freehand ultrasound
    • Nov
    • F. Rousseau, P. Hellier, M. M. Letteboer, W. J. Niessen, and C. Barillot, "Quantitative evaluation of three calibration methods for 3-D freehand ultrasound," IEEE Trans. Med. Imag. 25, pp. 1492-1501, Nov. 2006.
    • (2006) IEEE Trans. Med. Imag , vol.25 , pp. 1492-1501
    • Rousseau, F.1    Hellier, P.2    Letteboer, M.M.3    Niessen, W.J.4    Barillot, C.5
  • 9
    • 0043175141 scopus 로고    scopus 로고
    • Accuracy assessment protocols for electromagnetic tracking system
    • July
    • D. D. Frantz, A. D. Wiles, S. E. Leis, and S. R. Kirsch, "Accuracy assessment protocols for electromagnetic tracking system," Phys. Med. Biol. 48, pp. 2241-2251, July 2003.
    • (2003) Phys. Med. Biol , vol.48 , pp. 2241-2251
    • Frantz, D.D.1    Wiles, A.D.2    Leis, S.E.3    Kirsch, S.R.4
  • 10
    • 23244436362 scopus 로고    scopus 로고
    • New form factors for sensors and field generators of a magnetic tracking system
    • R. L. Galloway, Jr. and K. R. Cleary, eds, San Diego, CA, USA, Feb
    • S. R. Kirsch, C. Schilling, and G. Brunner, "New form factors for sensors and field generators of a magnetic tracking system," in Proceedings of SPIE, Medical Imaging, Visualization, Image-Guided Procedures, and Display, R. L. Galloway, Jr. and K. R. Cleary, eds., 5744, pp. 216-224, (San Diego, CA, USA), Feb. 2005.
    • (2005) Proceedings of SPIE, Medical Imaging, Visualization, Image-Guided Procedures, and Display , vol.5744 , pp. 216-224
    • Kirsch, S.R.1    Schilling, C.2    Brunner, G.3
  • 12
    • 35148826334 scopus 로고    scopus 로고
    • Development and testing of a new magnetic-tracking device for image guidance
    • K. R. Cleary and M. I. Miga, eds, SPIE, San Diego, CA, USA
    • M. Schneider and C. Stevens, "Development and testing of a new magnetic-tracking device for image guidance," in Medical Imaging 2007: Visualization and Image-Guided Procedures, K. R. Cleary and M. I. Miga, eds., 6509(1), p. 65090I, SPIE, (San Diego, CA, USA), 2007.
    • (2007) Medical Imaging 2007: Visualization and Image-Guided Procedures , vol.6509 , Issue.1
    • Schneider, M.1    Stevens, C.2
  • 13
    • 35148815831 scopus 로고    scopus 로고
    • E. Wilson, Z. Yaniv, H. Zhang, C. Nafis, E. Shen, G. Shechter, A. D. Wiles, T. Peters, D. Lindisch, and K. Cleary, A hardware and software protocol for the evaluation of electromagnetic tracker accuracy in the clinical environment: a multi-center study, in Medical Imaging 2007: Visualization and Image-Guided Procedures, K. R. Cleary and M. I. Miga, eds., 6509(1), p. 65O92T, SPIE, 2007.
    • E. Wilson, Z. Yaniv, H. Zhang, C. Nafis, E. Shen, G. Shechter, A. D. Wiles, T. Peters, D. Lindisch, and K. Cleary, "A hardware and software protocol for the evaluation of electromagnetic tracker accuracy in the clinical environment: a multi-center study," in Medical Imaging 2007: Visualization and Image-Guided Procedures, K. R. Cleary and M. I. Miga, eds., 6509(1), p. 65O92T, SPIE, 2007.
  • 14
    • 84957066839 scopus 로고    scopus 로고
    • Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift
    • Medical Image Computing and Computer-Assisted Intervention, MICCAI 1999
    • D. G. Gobbi, R. M. Comeau, and T. M. Peters, "Ultrasound probe tracking for real-time ultrasound/MRI overlay and visualization of brain shift," in Medical Image Computing and Computer-Assisted Intervention - MICCAI 1999, LNCS 1679, pp. 920-927, 1999.
    • (1999) LNCS , vol.1679 , pp. 920-927
    • Gobbi, D.G.1    Comeau, R.M.2    Peters, T.M.3
  • 16
    • 0004038491 scopus 로고
    • Least-squares best-fit geometric elements,
    • Tech. Rep. NPL Report DITC 140/89, National Physical Laboratory, Teddington, Middlesex, United Kingdom, April
    • A. B. Forbes, "Least-squares best-fit geometric elements," Tech. Rep. NPL Report DITC 140/89, National Physical Laboratory, Teddington, Middlesex, United Kingdom, April 1989.
    • (1989)
    • Forbes, A.B.1
  • 18
    • 33847038380 scopus 로고    scopus 로고
    • Objective performance testing and quality assurance of medical ultrasound equipment
    • J. M. Thijssen, G. Weijers, and C. L. D. Korte, "Objective performance testing and quality assurance of medical ultrasound equipment," Ultrasound in Med. & Biol. 33(3), pp. 460-471, 2007.
    • (2007) Ultrasound in Med. & Biol , vol.33 , Issue.3 , pp. 460-471
    • Thijssen, J.M.1    Weijers, G.2    Korte, C.L.D.3