메뉴 건너뛰기




Volumn 6918, Issue , 2008, Pages

Developing patient-specific anatomic models for validation of cardiac ablation guidance procedures

Author keywords

Cardiac Procedures; Surgical Simulation; Validation

Indexed keywords

(PL) PROPERTIES; ANATOMICAL LANDMARKS; BLOOD POOL (BP); CARDIAC ABLATION; CARDIAC ARRHYTHMIAS; CLINICAL OUTCOME; COMPUTED TOMOGRAPHY (CT) SCANS; GROUND TRUTH; IMAGE DATA; IMAGE-GUIDED; IMAGE-GUIDED PROCEDURES; IN ORDER; PATIENT ANATOMY; PHYSICAL MODEL (PM); RIGID MATERIALS; THIN-WALLED; VALIDATION PROTOCOLS;

EID: 44949180930     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.773215     Document Type: Conference Paper
Times cited : (9)

References (13)
  • 2
    • 7744227251 scopus 로고    scopus 로고
    • Enhanced left atrial mapping using digitally synchronized NavX three-dimensional nonfluoroscopic mapping and high-resolution computed tomographic imaging for catheter ablation of atrial fibrillation
    • Novak, P.G., et al., "Enhanced left atrial mapping using digitally synchronized NavX three-dimensional nonfluoroscopic mapping and high-resolution computed tomographic imaging for catheter ablation of atrial fibrillation," Heart Rhythm. 1(4), 521-2 (2004).
    • (2004) Heart Rhythm , vol.1 , Issue.4 , pp. 521-522
    • Novak, P.G.1
  • 3
    • 33645741619 scopus 로고    scopus 로고
    • An integrated system for real-time image guided cardiac catheter ablation
    • Rettmann, M.E., et al., "An integrated system for real-time image guided cardiac catheter ablation," Studies in Health Technology & Informatics. 119, 455-60 (2006).
    • (2006) Studies in Health Technology & Informatics , vol.119 , pp. 455-460
    • Rettmann, M.E.1
  • 4
    • 33645975865 scopus 로고    scopus 로고
    • Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation. [see comment]
    • Dong, J., et al., "Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation. [see comment]," Journal of Cardiovascular Electrophysiology. 17(5), 459-66 (2006).
    • (2006) Journal of Cardiovascular Electrophysiology , vol.17 , Issue.5 , pp. 459-466
    • Dong, J.1
  • 5
    • 34548046282 scopus 로고    scopus 로고
    • The changing face of postoperative atrial fibrillation prevention: A review of current medical therapy
    • Mayson, S.E., et al., "The changing face of postoperative atrial fibrillation prevention: a review of current medical therapy," Cardiology in Review. 15(5), 231-41 (2007).
    • (2007) Cardiology in Review , vol.15 , Issue.5 , pp. 231-241
    • Mayson, S.E.1
  • 6
    • 0742318815 scopus 로고    scopus 로고
    • Acute effects of left atrial radiofrequency ablation on atrial fibrillation.[see comment]
    • Scharf, C., et al., "Acute effects of left atrial radiofrequency ablation on atrial fibrillation.[see comment]," Journal of Cardiovascular Electrophysiology. 15(5), 515-21 (2004).
    • (2004) Journal of Cardiovascular Electrophysiology , vol.15 , Issue.5 , pp. 515-521
    • Scharf, C.1
  • 9
    • 0030345039 scopus 로고    scopus 로고
    • Cameron, B.M., A. Manduca, and R.A. Robb, Patient-specific anatomic models. Geometric surface generation from three-dimensional medical images using a specified polygonal budget, Studies in Health Technology & Informatics. 29, 447-60 (1996).
    • Cameron, B.M., A. Manduca, and R.A. Robb, "Patient-specific anatomic models. Geometric surface generation from three-dimensional medical images using a specified polygonal budget," Studies in Health Technology & Informatics. 29, 447-60 (1996).
  • 11
    • 44949094962 scopus 로고    scopus 로고
    • Smooth-On, Liquid Rubber (http://www.smooth-on. com/liqrubr.htm).
    • Smooth-On, "Liquid Rubber (http://www.smooth-on. com/liqrubr.htm)."
  • 12
    • 0042626217 scopus 로고    scopus 로고
    • Piecewise registration for point-to-surface mapping of cardiac data
    • Harris, S.S. and R.A. Robb, "Piecewise registration for point-to-surface mapping of cardiac data," SPIE Medical Imaging. 5031, 146-153 (2003).
    • (2003) SPIE Medical Imaging , vol.5031 , pp. 146-153
    • Harris, S.S.1    Robb, R.A.2
  • 13
    • 33750036653 scopus 로고    scopus 로고
    • Integration of cardiac CT/MR imaging with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: Implications for catheter ablation of atrial fibrillation
    • Malchano, Z.J., et al., "Integration of cardiac CT/MR imaging with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: implications for catheter ablation of atrial fibrillation," Journal of Cardiovascular Electrophysiology. 17(11), 1221-9 (2006).
    • (2006) Journal of Cardiovascular Electrophysiology , vol.17 , Issue.11 , pp. 1221-1229
    • Malchano, Z.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.