메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1087-1090

A combined surface and volumetric approach for registration of patient specific models into left atrial cardiac ablation procedures

Author keywords

Biomedical image processing; Cardiac ablation; Image guidance; Left atrium

Indexed keywords

BIOMEDICAL IMAGE PROCESSING; BIPLANE FLUOROSCOPY; CARDIAC ABLATION; COMBINED SURFACE; FIDUCIAL MARKER; GROUND TRUTH; IMAGE GUIDANCE; KEY COMPONENT; LEFT ATRIUM; MEAN ERRORS; PATIENT ANATOMY; PATIENT SPECIFIC MODEL; POINT SELECTION; PREOPERATIVE MODELS; REGISTRATION ACCURACY; REGISTRATION TECHNIQUES; SURFACE POINTS; SURFACE-BASED; SURFACE-BASED METHODS; VISUALIZATION TOOLS; VOLUMETRIC APPROACH;

EID: 70449331286     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2009.5193245     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 1
    • 36349015998 scopus 로고    scopus 로고
    • Atrial fibrillation: Insights from clinical trials and novel treatment options
    • Y. Blaauw and H.J.G.M. Crijns, "Atrial fibrillation: insights from clinical trials and novel treatment options.," Journal of Internal Medicine, vol. 262, pp. 593-614, 2007.
    • (2007) Journal of Internal Medicine , vol.262 , pp. 593-614
    • Blaauw, Y.1    Crijns, H.J.G.M.2
  • 2
    • 35148859632 scopus 로고    scopus 로고
    • Intraprocedural fusion of electroanatomic maps (EAM) with imaging data based on rapidly-sampled volumetric point clouds from continous eam catheter tracking
    • R.C. Chan et. al., "Intraprocedural fusion of electroanatomic maps (EAM) with imaging data based on rapidly-sampled volumetric point clouds from continous eam catheter tracking," in SPIE Medical Imaging, 2007.
    • (2007) SPIE Medical Imaging
    • Chan, R.C.1    et., al.2
  • 3
    • 0242694547 scopus 로고    scopus 로고
    • Anatomic stereotactic catheter ablation on three-dimensionalMagnetic resonance images in real time
    • T. Dickfeld et. al., "Anatomic stereotactic catheter ablation on three-dimensionalMagnetic resonance images in real time," Circulation, vol. 108, pp. 2407-2413, 2003.
    • (2003) Circulation , vol.108 , pp. 2407-2413
    • Dickfeld, T.1    et., al.2
  • 4
    • 58049209817 scopus 로고    scopus 로고
    • The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: A prospective randomized study
    • P.M. Kistler et. al., "The impact of image integration on catheter ablation of atrial fibrillation using electroanatomic mapping: a prospective randomized study," European Heart Journal, vol. 29, pp. 3029-3036, 2008.
    • (2008) European Heart Journal , vol.29 , pp. 3029-3036
    • Kistler, P.M.1    et., al.2
  • 5
    • 4644303209 scopus 로고    scopus 로고
    • Role of imaging techniques in preparation for catheter ablation of atrial fibrillation
    • M. Mansour, G. Holmvang, and J. Ruskin, "Role of imaging techniques in preparation for catheter ablation of atrial fibrillation," J. Cardiovasc Electrophysiol, vol. 15, pp. 1107-1108, 2004.
    • (2004) J. Cardiovasc Electrophysiol , vol.15 , pp. 1107-1108
    • Mansour, M.1    Holmvang, G.2    Ruskin, J.3
  • 6
    • 9644265416 scopus 로고    scopus 로고
    • Integration of cardiac magnetic resonance imaging with three-dimensional electroanatomic mapping to guide left ventricular catheter manipulation
    • V.Y. Reddy et. al., "Integration of cardiac magnetic resonance imaging with three-dimensional electroanatomic mapping to guide left ventricular catheter manipulation," Journal of the American College of Cardiology, vol. 44, no. 11, pp. 2202-13, 2004.
    • (2004) Journal of the American College of Cardiology , vol.44 , Issue.11 , pp. 2202-2213
    • Reddy, V.Y.1    et., al.2
  • 8
    • 47749121816 scopus 로고    scopus 로고
    • Validation of computed tomography image integration into the EnSite NavX mapping system to perform catheter ablation of atrial fibrillation
    • L. Richmond et. al., "Validation of computed tomography image integration into the EnSite NavX mapping system to perform catheter ablation of atrial fibrillation," J Cardiovasc Electrophysiol, vol. 19, pp. 821-827, 2008.
    • (2008) J Cardiovasc Electrophysiol , vol.19 , pp. 821-827
    • Richmond, L.1    et., al.2
  • 9
    • 47349126400 scopus 로고    scopus 로고
    • Cardiac image integration implications for atrial fibrillation ablation
    • J. Sra, "Cardiac image integration implications for atrial fibrillation ablation.," J Interv Card Electrophysiol, vol. 22, pp. 145-154, 2008.
    • (2008) J Interv Card Electrophysiol , vol.22 , pp. 145-154
    • Sra, J.1
  • 10
    • 23244456965 scopus 로고    scopus 로고
    • Registration of high-resolution 3D atrial images with elecroanatomical cardiac mapping: Evaluation of registration methodology
    • Y. Sun et. al., "Registration of high-resolution 3D atrial images with elecroanatomical cardiac mapping: Evaluation of registration methodology," in SPIE Medical Imaging, 2005, pp. 299-307.
    • (2005) SPIE Medical Imaging , pp. 299-307
    • Sun, Y.1    et., al.2
  • 11
    • 44349099676 scopus 로고    scopus 로고
    • M.E. Rettmann et. al., Validation of semi-automatic segmentation of the left atrium, in Proceedings of SPIE - 6916, 2008.
    • M.E. Rettmann et. al., "Validation of semi-automatic segmentation of the left atrium," in Proceedings of SPIE - Volume 6916, 2008.
  • 12
    • 67349086267 scopus 로고    scopus 로고
    • An event-driven distributed processing architecture for image-guided cardiac ablation therapy
    • M.E. Rettmann et. al., "An event-driven distributed processing architecture for image-guided cardiac ablation therapy," Computer Programs and Methods in Biomedicine, vol. 95, no. 2, pp. 95-104, 2009.
    • (2009) Computer Programs and Methods in Biomedicine , vol.95 , Issue.2 , pp. 95-104
    • Rettmann, M.E.1    et., al.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.