메뉴 건너뛰기




Volumn 59, Issue 1 PART 1, 2012, Pages 113-122

Realistic and efficient modeling of radiotracer heterogeneity in Monte Carlo simulations of PET images with tumors

Author keywords

Monte Carlo (MC) simulation; Patient monitoring; PET imaging; Realistic simulation

Indexed keywords

ANTHROPOMORPHIC PHANTOMS; MONTE CARLO SIMULATION; MONTE CARLO SIMULATIONS; NUMERICAL PHANTOMS; PATHOLOGICAL CASE; PET IMAGES; PET IMAGING; PET SCAN; PHYSIOLOGICAL ACTIVITY; REALISTIC MODELING; REALISTIC SIMULATION; RELIABLE ESTIMATES; SIMULATED IMAGES; THERAPY MONITORING; TUMOR ACTIVITY; TUMOR SHAPE;

EID: 84857343364     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2011.2177277     Document Type: Article
Times cited : (11)

References (31)
  • 1
    • 75749089680 scopus 로고    scopus 로고
    • Comparative assessment of methods for estimating tumor volume and standardized uptake value in 18F-FDG PET
    • P. Tylski, S. Stute, N. Grotus, K. Doyeux, S. Hapdey, and I. Gardin et al., "Comparative assessment of methods for estimating tumor volume and standardized uptake value in 18F-FDG PET", J. Nucl. Med., vol. 51, pp. 268-276, 2010.
    • (2010) J. Nucl. Med. , vol.51 , pp. 268-276
    • Tylski, P.1    Stute, S.2    Grotus, N.3    Doyeux, K.4    Hapdey, S.5    Gardin, I.6
  • 2
    • 33747052890 scopus 로고    scopus 로고
    • Partial volume effect correction in SPECT for striatal uptake measurements in patients with neurodegenerative diseases: Impact upon patient classification
    • DOI 10.1007/s00259-005-0003-4
    • M. Soret, P. Koulibaly, J. Darcourt, and I. Buvat, "Partial volume effect correction in SPECT for striatal uptake measurements in patients with neurodegenerative diseases: Impact upon patient classification", Eur. J. Nucl. Med. Mol. Imaging, vol. 33, pp. 1062-1072, 2006. (Pubitemid 44215672)
    • (2006) European Journal of Nuclear Medicine and Molecular Imaging , vol.33 , Issue.9 , pp. 1062-1072
    • Soret, M.1    Koulibaly, P.M.2    Darcourt, J.3    Buvat, I.4
  • 3
    • 0036464372 scopus 로고    scopus 로고
    • Performance analysis of an improved 3-D PET Monte Carlo simulation and scatter correction
    • DOI 10.1109/TNS.2002.998686, PII S001894990201643X
    • C. H. Holdsworth, C. S. Levin, M. Janecek, M. Dahlbom, and E. J. Hoffman, "Performance analysis of an improved 3D PET Monte Carlo simulation and scatter correction", IEEE Trans. Nucl. Sci., vol. 49, no. 1, pp. 83-89, Feb. 2002. (Pubitemid 34658198)
    • (2002) IEEE Transactions on Nuclear Science , vol.49 , Issue.1 , pp. 83-89
    • Holdsworth, C.H.1    Levin, C.S.2    Janecek, M.3    Dahlbom, M.4    Hoffman, E.J.5
  • 4
    • 26244447702 scopus 로고    scopus 로고
    • Monte Carlo simulation and scatter correction of the GE advance PET scanner with SimSET and Geant4
    • O. Barret, T. A. Carpenter, J. C. Clark, R. E. Ansorge, and T. D. Fryer, "Monte Carlo simulation and scatter correction of the GE advance PET scanner with SimSET and Geant4", Phys. Med. Biol., vol. 50, pp. 4823-4848, 2005.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 4823-4848
    • Barret, O.1    Carpenter, T.A.2    Clark, J.C.3    Ansorge, R.E.4    Fryer, T.D.5
  • 5
    • 17644371636 scopus 로고    scopus 로고
    • Lesion detectability and quantification in PET/CT oncological studies by Monte Carlo simulations
    • DOI 10.1109/TNS.2005.844018
    • I. Castiglioni, G. Rizzo, M. Gilardi, V. Bettinardi, A. Savi, and F. Fazio, "Lesion detectability and quantification in PET/CT oncological studies by Monte Carlo simulations", IEEE Trans. Nucl. Sci., vol. 52, no. 1, pp. 136-142, Feb. 2005. (Pubitemid 40564964)
    • (2005) IEEE Transactions on Nuclear Science , vol.52 , Issue.1 , pp. 136-142
    • Castiglioni, I.1    Rizzo, G.2    Gilardi, M.C.3    Bettinardi, V.4    Savi, A.5    Fazio, F.6
  • 6
    • 77950633331 scopus 로고    scopus 로고
    • OncoPET-DB: A freely distributed database of realistic simulated whole-body 18F-FDG PET images in oncology
    • Feb.
    • S. Tomei, A. Reilhac, D. Visvikis, N. Boussion, C. Odet, and F. Giammarile et al., "OncoPET-DB: A freely distributed database of realistic simulated whole-body 18F-FDG PET images in oncology", IEEE Trans. Nucl. Sci., vol. 57, no. 1, pp. 246-255, Feb. 2010.
    • (2010) IEEE Trans. Nucl. Sci. , vol.57 , Issue.1 , pp. 246-255
    • Tomei, S.1    Reilhac, A.2    Visvikis, D.3    Boussion, N.4    Odet, C.5    Giammarile, F.6
  • 7
  • 8
    • 71049142726 scopus 로고    scopus 로고
    • A quantitative evaluation study of four-dimensional gated cardiac SPECT reconstruction
    • M. Jin, Y. Yang, X. Niu, T. Marin, J. G. Brankov, and B. Feng et al., "A quantitative evaluation study of four-dimensional gated cardiac SPECT reconstruction", Phys. Med. Biol., vol. 54, pp. 5643-5659, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 5643-5659
    • Jin, M.1    Yang, Y.2    Niu, X.3    Marin, T.4    Brankov, J.G.5    Feng, B.6
  • 9
    • 67649196775 scopus 로고    scopus 로고
    • LuCaS: Efficient Monte Carlo simulations of highly realistic PET tumor images
    • S. Stute, P. Tylski, N. Grotus, and I. Buvat, "LuCaS: Efficient Monte Carlo simulations of highly realistic PET tumor images", IEEE Nucl. Sci. Symp. Conf. Rec., pp. 4010-4012, 2008.
    • (2008) IEEE Nucl. Sci. Symp. Conf. Rec. , pp. 4010-4012
    • Stute, S.1    Tylski, P.2    Grotus, N.3    Buvat, I.4
  • 10
    • 70450174223 scopus 로고    scopus 로고
    • Incorporating patient-specific variability in the simulation of realistic whole-body 18F-FDG distributions for oncology applications
    • Dec.
    • A. Le Maitre, W. P. Segars, S. Marache, A. Reilhac, M. Hatt, and S. Tomei et al., "Incorporating patient-specific variability in the simulation of realistic whole-body 18F-FDG distributions for oncology applications", Proc. IEEE, vol. 97, no. 12, pp. 2026-2038, Dec. 2009.
    • (2009) Proc. IEEE , vol.97 , Issue.12 , pp. 2026-2038
    • Le Maitre, A.1    Segars, W.P.2    Marache, S.3    Reilhac, A.4    Hatt, M.5    Tomei, S.6
  • 11
    • 0025683713 scopus 로고
    • High resolution anthropomorphic phantom for Monte Carlo analysis of internal radiation sources
    • G. Zubal, G. Gindi, M. Lee, C. Harrell, and E. Smith, "High resolution anthropomorphic phantom for Monte Carlo analysis of internal radiation sources", IEEE Comp. Based Med. Syst. Symp. Proc., pp. 540-547, 1990.
    • (1990) IEEE Comp. Based Med. Syst. Symp. Proc. , pp. 540-547
    • Zubal, G.1    Gindi, G.2    Lee, M.3    Harrell, C.4    Smith, E.5
  • 12
    • 70450162884 scopus 로고    scopus 로고
    • MCAT to XCAT: The evolution of 4-D computerized phantoms for imaging research
    • Dec.
    • W. P. Segars and B. M. W. Tsui, "MCAT to XCAT: The evolution of 4-D computerized phantoms for imaging research", Proc. IEEE, vol. 97, no. 12, pp. 1954-1968, Dec. 2009.
    • (2009) Proc. IEEE , vol.97 , Issue.12 , pp. 1954-1968
    • Segars, W.P.1    Tsui, B.M.W.2
  • 13
    • 70450270835 scopus 로고    scopus 로고
    • Review of computational anthropomorphic anatomical and physiological models
    • Dec.
    • H. Zaidi and B. M. W. Tsui, "Review of computational anthropomorphic anatomical and physiological models", Proc. IEEE, vol. 97, no. 12, pp. 1938-1953, Dec. 2009.
    • (2009) Proc. IEEE , vol.97 , Issue.12 , pp. 1938-1953
    • Zaidi, H.1    Tsui, B.M.W.2
  • 14
    • 33846577665 scopus 로고    scopus 로고
    • An investigation of reconstruction strategies for mediastinal lesion detection using hybrid Ga-67 SPECT images
    • DOI 10.1109/NSSMIC.2005.1596645, 1596645, 2005 IEEE Nuclear Science Symposium Conference Record -Nuclear Science Symposium and Medical Imaging Conference
    • N. F. Pereira, H. C. Gifford, T. H. Farncombe, M. Smyczynski, and M. A. King, "An investigation of reconstruction strategies for mediastinal lesion detection using hybrid Ga-67 SPECT images", in IEEE Nucl. Sci. Symp. Conf. Rec., 2005, vol. 3, pp. 1691-1694. (Pubitemid 46172069)
    • (2005) IEEE Nuclear Science Symposium Conference Record , vol.3 , pp. 1691-1694
    • Pereira, N.F.1    Gifford, H.C.2    Farncombe, T.H.3    Smyczynski, M.4    King, M.A.5
  • 15
  • 16
    • 67649148611 scopus 로고    scopus 로고
    • Effectiveness of three alternative strategies in reducing the degrading impact of respiratory motion on the detection of small pulmonary nodules in SPECT imaging
    • M. Smyczynski, H. C. Gifford, A. Lehovich, J. E. McNamara, and W. P. Segars et al., "Effectiveness of three alternative strategies in reducing the degrading impact of respiratory motion on the detection of small pulmonary nodules in SPECT imaging", in IEEE Nucl. Sci. Symp. Conf. Rec., 2008, pp. 3663-3667.
    • (2008) IEEE Nucl. Sci. Symp. Conf. Rec. , pp. 3663-3667
    • Smyczynski, M.1    Gifford, H.C.2    Lehovich, A.3    McNamara, J.E.4    Segars, W.P.5
  • 18
    • 63649158562 scopus 로고    scopus 로고
    • Introducing improved voxel navigation and fictitious interaction tracking in GATE for enhanced efficiency
    • N. S. Rehfeld, S. Stute, J. Apostolakis, M. Soret, and I. Buvat, "Introducing improved voxel navigation and fictitious interaction tracking in GATE for enhanced efficiency", Phys. Med. Biol., vol. 54, pp. 2163-2178, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 2163-2178
    • Rehfeld, N.S.1    Stute, S.2    Apostolakis, J.3    Soret, M.4    Buvat, I.5
  • 19
    • 0028216170 scopus 로고
    • A convolution-subtraction scatter correction method for 3D PET
    • D. L. Bailey and S. R. Meikle, "A convolution-subtraction scatter correction method for 3D PET", Phys. Med. Biol., vol. 39, pp. 411-424, 1994. (Pubitemid 24149124)
    • (1994) Physics in Medicine and Biology , vol.39 , Issue.3 , pp. 411-424
    • Bailey, D.L.1    Meikle, S.R.2
  • 20
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. A. Shepp and Y. Vardi, "Maximum likelihood reconstruction for emission tomography", IEEE Trans. Med. Imag., vol. MI-1, no. 2, pp. 113-122, Oct. 1982. (Pubitemid 13557763)
    • (1982) IEEE Transactions on Medical Imaging , vol.MI-1 , Issue.2 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 21
    • 0026121689 scopus 로고
    • Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography
    • Mar.
    • D. G. Politte and D. L. Snyder, "Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography", IEEE Trans. Med. Imag., vol. 10, no. 1, pp. 82-89, Mar. 1991.
    • (1991) IEEE Trans. Med. Imag. , vol.10 , Issue.1 , pp. 82-89
    • Politte, D.G.1    Snyder, D.L.2
  • 22
    • 7244251647 scopus 로고    scopus 로고
    • LOR-OSEM: Statistical PET reconstruction from raw line-of-response histograms
    • DOI 10.1088/0031-9155/49/20/005, PII S0031915504812508
    • D. J. Kadrmas, "LOR-OSEM: Statistical PET reconstruction from raw line-of-response histograms", Phys. Med. Biol., vol. 49, pp. 4731-4744, 2004. (Pubitemid 39433502)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.20 , pp. 4731-4744
    • Kadrmas, D.J.1
  • 24
    • 0342372405 scopus 로고    scopus 로고
    • Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients
    • Available
    • J. H. Hubbel and S. M. Seltzer, Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients, NIST website [Online]. Available: nist.gov/physlab/data/xraycoef, 1996.
    • (1996) NIST Website [Online]
    • Hubbel, J.H.1    Seltzer, S.M.2
  • 25
    • 0030270511 scopus 로고    scopus 로고
    • A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography
    • Oct.
    • J. A. Browne and A. R. Pierro, "A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography", IEEE Trans. Med. Imag., vol. 15, no. 5, pp. 687-699, Oct. 1996.
    • (1996) IEEE Trans. Med. Imag. , vol.15 , Issue.5 , pp. 687-699
    • Browne, J.A.1    Pierro, A.R.2
  • 26
    • 0031457987 scopus 로고    scopus 로고
    • Segmentation of lung lesion volume by adaptive positron emission tomography image thresholding
    • Y. E. Erdi, O. Mawlawi, S. M. Larson, M. Imbriaco, H. Yeung, and R. Finn et al., "Segmentation of lung lesion volume by adaptative positron emission tomography image thresholding", Cancer, vol. 80, pp. 2505-2509, 1997. (Pubitemid 28009506)
    • (1997) Cancer , vol.80 , Issue.SUPPL. 12 , pp. 2505-2509
    • Erdi, Y.E.1    Mawlawi, O.2    Larson, S.M.3    Imbriaco, M.4    Yeung, H.5    Finn, R.6    Humm, J.L.7
  • 27
    • 0034244929 scopus 로고    scopus 로고
    • New, faster, image-based scatter correction for 3D PET
    • Aug.
    • C. C. Watson, "New, faster, image-based scatter correction for 3D PET", IEEE Trans. Nucl. Sci., vol. 47, no. 4, pp. 1587-1594, Aug. 2000.
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , Issue.4 , pp. 1587-1594
    • Watson, C.C.1
  • 28
    • 80053178031 scopus 로고    scopus 로고
    • Monte Carlo simulations of clinical PET and SPECT scans: Impact of the input data on the simulated images
    • S. Stute, T. Carlier, K. Cristina, C. Noblet, and A. Martineau et al., "Monte Carlo simulations of clinical PET and SPECT scans: Impact of the input data on the simulated images", Phys. Med. Biol., vol. 56, pp. 6441-6457, 2011.
    • (2011) Phys. Med. Biol. , vol.56 , pp. 6441-6457
    • Stute, S.1    Carlier, T.2    Cristina, K.3    Noblet, C.4    Martineau, A.5
  • 29
    • 79952789282 scopus 로고    scopus 로고
    • Detection and characterization of tumor changes in 18F-FDG PET patient monitoring using parametric imaging
    • H. Necib, C. Garcia, A. Wagner, B. Vanderlinden, P. Emonts, and A. Hendlisz et al., "Detection and characterization of tumor changes in 18F-FDG PET patient monitoring using parametric imaging", J. Nucl. Med., vol. 52, pp. 354-361, 2011.
    • (2011) J. Nucl. Med. , vol.52 , pp. 354-361
    • Necib, H.1    Garcia, C.2    Wagner, A.3    Vanderlinden, B.4    Emonts, P.5    Hendlisz, A.6
  • 31
    • 77950689496 scopus 로고    scopus 로고
    • Accurate automatic delineation of heterogeneous functional volumes in positron emission tomography for oncology applications
    • M. Hatt, C. Cheze Le Rest, P. Descourt, A. Dekker, D. De Ruysscher, and M. Oellers et al., "Accurate automatic delineation of heterogeneous functional volumes in positron emission tomography for oncology applications", Int. J. Radiat. Oncol. Biol. Phys., vol. 77, pp. 301-308, 2010.
    • (2010) Int. J. Radiat. Oncol. Biol. Phys. , vol.77 , pp. 301-308
    • Hatt, M.1    Cheze Le Rest, C.2    Descourt, P.3    Dekker, A.4    De Ruysscher, D.5    Oellers, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.