메뉴 건너뛰기




Volumn , Issue , 2008, Pages 3663-3667

Effectiveness of three alternative strategies in reducing the degrading impact ofrespiratory motion on the detection of small pulmonary nodules in SPECT imaging

Author keywords

[No Author keywords available]

Indexed keywords

4-FRAMES; ATTENUATION MAPS; COUNTS-AS; LESION DETECTION; MONTE CARLO PROGRAMS; NOISE LEVELS; PROJECTION DATA; PULMONARY NODULES; RESPIRATORY CYCLE; RESPIRATORY MOTIONS; SINGLE PHOTON EMISSION; SPECT IMAGING; SPECT PROJECTIONS; TIME-AVERAGED; TOMOGRAPHIC IMAGING; TORSO PHANTOM; TOTAL COUNTS;

EID: 67649148611     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774111     Document Type: Conference Paper
Times cited : (1)

References (11)
  • 1
    • 0020418611 scopus 로고
    • Influence of cardiac and respiratory motion on tomographic reconstructions of the heart
    • M. M. Ter-Pogossian, S. R. Bergmann, and B. E. Sobel, "Influence of cardiac and respiratory motion on tomographic reconstructions of the heart,".J. Camp Assist Tomog, vol.6, pp. 1148-1152,1982.
    • (1982) J. Camp Assist Tomog , vol.6 , pp. 1148-1152
    • Ter-Pogossian, M.M.1    Bergmann, S.R.2    Sobel, B.E.3
  • 2
    • 0023639048 scopus 로고
    • Simulation and experimental study of respiratory motion effect on image quality of single photon emission computed tomography (SPECT)
    • K. Murase, M. Ishine, M. Kataoka, h. Itoh, H. Mogami, A. lio, "Simulation and experimental study of respiratory motion effect of image quality of single photon emission computed tomography (SPECT)," Eur J Nucl Med, vol.13, pp. 244-249,1987. (Pubitemid 17142393)
    • (1987) European Journal of Nuclear Medicine , vol.13 , Issue.5 , pp. 244-249
    • Murase, K.1    Ishine, M.2    Kataoka, M.3    Itoh, H.4    Mogami, H.5    Iio, A.6    Hamamoto, K.7
  • 4
    • 0032742084 scopus 로고    scopus 로고
    • A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging
    • P. H. Pretorius, M. A. King, B. M. W. Tsui, K. J. LaCroix, and W. Xia, "A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging," Medical Physics, vol.26, pp. 2323-2332, 1999.
    • (1999) Medical Physics , vol.26 , pp. 2323-2332
    • Pretorius, P.H.1    King, M.A.2    Tsui, B.M.W.3    Lacroix, K.J.4    Xia, W.5
  • 6
    • 0035246235 scopus 로고    scopus 로고
    • Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms
    • DOI 10.1109/23.910837
    • W. P. Segars, D. S. Lalush, and B. M. W. Tsui, "Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms," Trans. on Nucl. Sci., vol.48, pp. 89-97,2001. (Pubitemid 32325607)
    • (2001) IEEE Transactions on Nuclear Science , vol.48 , Issue.1 , pp. 89-97
    • Segars, W.P.1    Lalush, D.S.2    Tsui, B.M.W.3
  • 10
    • 0024713937 scopus 로고
    • Monte Carlo program for the simulation of scintillation camera characteristics
    • DOI 10.1016/0169-2607(89)90111-9
    • M. Ljungberg, and S-E Strand, "A monte carlo program for the simulation of scintillation camera characteristics," Comp Meth Prog Biomed, vol.29, pp. 257-272, 1989. (Pubitemid 20610320)
    • (1989) Computer Methods and Programs in Biomedicine , vol.29 , Issue.4 , pp. 257-272
    • Ljungberg Michael1    Strand Sven-Erik2
  • 11
    • 0029822853 scopus 로고    scopus 로고
    • Unified measurement of observer performance in detecting and localizing target objects on images
    • R. G. Swensson, "Unified measurement of observer performance in detecting and localizing target objects on images" Medical Physics. vol. 23, pp. 1709-1725,1996.
    • (1996) Medical Physics , vol.23 , pp. 1709-1725
    • Swensson, R.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.