메뉴 건너뛰기




Volumn 5, Issue , 2007, Pages 3241-3245

Impact of respiratory motion on the detection of small pulmonary nodules in SPECT imaging

Author keywords

[No Author keywords available]

Indexed keywords

BIOMECHANICS; COMPUTERIZED TOMOGRAPHY; NORMAL DISTRIBUTION; RESPIRATORY MECHANICS; RESTORATION; TECHNETIUM; THREE DIMENSIONAL; TUMORS;

EID: 48349086159     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436830     Document Type: Conference Paper
Times cited : (7)

References (16)
  • 1
    • 0020418611 scopus 로고
    • Influence of cardiac and respiratory motion on tomographic reconstructions of the heart
    • M. M. Ter-Pogossian, S. R. Bergmann, and B. E. Sobel, "Influence of cardiac and respiratory motion on tomographic reconstructions of the heart," J. Comp Assist Tomog, vol. 6, pp. 1148-1152, 1982.
    • (1982) J. Comp Assist Tomog , vol.6 , pp. 1148-1152
    • Ter-Pogossian, M.M.1    Bergmann, S.R.2    Sobel, B.E.3
  • 2
    • 0023639048 scopus 로고
    • Simulation and experimental study of respiratory motion effect of image quality of single photon emission computed tomography (SPECT)
    • K. Murase, M. Ishine, M. Kataoka, h. Itoh, H. Mogami, A. Iio, "Simulation and experimental study of respiratory motion effect of image quality of single photon emission computed tomography (SPECT)," Eur J Nucl Med, vol. 13, pp. 244-249, 1987.
    • (1987) Eur J Nucl Med , vol.13 , pp. 244-249
    • Murase, K.1    Ishine, M.2    Kataoka, M.3    Itoh, H.4    Mogami, H.5    Iio, A.6
  • 6
    • 0032742084 scopus 로고    scopus 로고
    • A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging
    • P. H. Pretorius, M. A. King, B. M. W. Tsui, K. J. LaCroix and W. Xia, "A mathematical model of motion of the heart for use in generating source and attenuation maps for simulating emission imaging." Medical Physics, vol. 26. pp. 2323-2332. 1999.
    • (1999) Medical Physics , vol.26 , pp. 2323-2332
    • Pretorius, P.H.1    King, M.A.2    Tsui, B.M.W.3    LaCroix, K.J.4    Xia, W.5
  • 7
    • 0004010864 scopus 로고    scopus 로고
    • Development of a new dynamic NURBS-based cardiactorso phantom,
    • Ph.D. Dissertation, Department of Biomedical Engineering, University of North Carolina, May
    • W. P. Segars "Development of a new dynamic NURBS-based cardiactorso phantom," Ph.D. Dissertation, Department of Biomedical Engineering, University of North Carolina, May 2001.
    • (2001)
    • Segars, W.P.1
  • 8
    • 0035246235 scopus 로고    scopus 로고
    • Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms
    • W. P. Segars, D. S. Lalush, and B. M. W. Tsui, "Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms." IEEE Trans, on Nucl. Sci., vol. 48, pp. 89-97, 2001.
    • (2001) IEEE Trans, on Nucl. Sci , vol.48 , pp. 89-97
    • Segars, W.P.1    Lalush, D.S.2    Tsui, B.M.W.3
  • 9
    • 0032953457 scopus 로고    scopus 로고
    • The utility of a somatostatin-type receptor binding peptide radiophamaceutical (P829) in the evaluation of solitary pulmonary nodules
    • J. E. Blum, H. Handmaker, and N. A. Rinne, "The utility of a somatostatin-type receptor binding peptide radiophamaceutical (P829) in the evaluation of solitary pulmonary nodules," Chest, vol. 115, pp. 224-232, 1999.
    • (1999) Chest , vol.115 , pp. 224-232
    • Blum, J.E.1    Handmaker, H.2    Rinne, N.A.3
  • 10
    • 0024713937 scopus 로고
    • A monte carlo program for the simulation of scintillation camera characteristics
    • M. Ljungberg and S-E Strand, "A monte carlo program for the simulation of scintillation camera characteristics," Comp Meth Prog Biomed, vol. 29, pp. 257-272. 1989.
    • (1989) Comp Meth Prog Biomed , vol.29 , pp. 257-272
    • Ljungberg, M.1    Strand, S.-E.2
  • 11
    • 0036624636 scopus 로고    scopus 로고
    • The impact of noisy and misaligned attenuation maps on human-observer performance at lesion detection in SPECT
    • R. G. Wells, H. C. Gifford, P. H. Pretorius, T. H. Farncombe, M. V. Narayanan, and M. A. King, "The impact of noisy and misaligned attenuation maps on human-observer performance at lesion detection in SPECT," IEEE Trans, on Nucl. Sci., vol. 49, pp. 753-760, 2002.
    • (2002) IEEE Trans, on Nucl. Sci , vol.49 , pp. 753-760
    • Wells, R.G.1    Gifford, H.C.2    Pretorius, P.H.3    Farncombe, T.H.4    Narayanan, M.V.5    King, M.A.6
  • 12
    • 0035297606 scopus 로고    scopus 로고
    • An interior point iterative maximum-likelihood reconstruction algorithm incorporating upper and lower bounds with application to SPECT transmission imaging
    • M. V. Narayanan, C. L. Byrne, and M. A. King, "An interior point iterative maximum-likelihood reconstruction algorithm incorporating upper and lower bounds with application to SPECT transmission imaging," IEEE Trans. Med. Imaging, vol. 20. pp. 342-353, 2001.
    • (2001) IEEE Trans. Med. Imaging , vol.20 , pp. 342-353
    • Narayanan, M.V.1    Byrne, C.L.2    King, M.A.3
  • 14
    • 0026221904 scopus 로고
    • A practical method for position-dependent Compton-scatter correction in single photon emission CT
    • K. Ogawa, Y. Harata, T. Ichihara, A. Kubo, and S. Hashimoto, "A practical method for position-dependent Compton-scatter correction in single photon emission CT, IEEE Trans. Med. Imaging, vol. 10, pp. 408-412, 1991.
    • (1991) IEEE Trans. Med. Imaging , vol.10 , pp. 408-412
    • Ogawa, K.1    Harata, Y.2    Ichihara, T.3    Kubo, A.4    Hashimoto, S.5
  • 15
    • 0029822853 scopus 로고    scopus 로고
    • Unified measurement of observer performance in detecting and localizing target objects on images
    • R. G. Swensson, "Unified measurement of observer performance in detecting and localizing target objects on images," Medical Physics, vol. 23, pp. 1709-1725, 1996.
    • (1996) Medical Physics , vol.23 , pp. 1709-1725
    • Swensson, R.G.1
  • 16
    • 0142241180 scopus 로고    scopus 로고
    • Ga-67 tumor detection using penalized-EM with nonanatomical regularizes
    • Norfolk, VA, November
    • H. C. Gifford, T. H. Farncombe, and M. A. King, "Ga-67 tumor detection using penalized-EM with nonanatomical regularizes," Proceedings of NSS MIC, Norfolk, VA, November 2002.
    • (2002) Proceedings of NSS MIC
    • Gifford, H.C.1    Farncombe, T.H.2    King, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.