-
2
-
-
84857238424
-
-
Das Magazin der CeramTec AG, Medizintechnik; 1/2008
-
CeraNews. Ceramics in Orthopaedics. Das Magazin der CeramTec AG, Medizintechnik; 1/2008.
-
CeraNews. Ceramics in Orthopaedics
-
-
-
4
-
-
34249933860
-
Squeaking in Ceramic-on-Ceramic Hips. The Importance of Acetabular Component Orientation
-
DOI 10.1016/j.arth.2006.06.018, PII S0883540306005122
-
W.L. Walter, G.C. OToole, W.K. Walter, A. Ellis, and B.A. Zicat Squeaking in ceramic on-ceramic hips: the importance of acetabular component orientation The Journal of Arthroplasty 22 2007 496 503 (Pubitemid 46880178)
-
(2007)
Journal of Arthroplasty
, vol.22
, Issue.4
, pp. 496-503
-
-
Walter, W.L.1
O'Toole, G.C.2
Walter, W.K.3
Ellis, A.4
Zicat, B.A.5
-
5
-
-
58149337269
-
Squeaking in total hip replacement: No cause for concern
-
T. Ecker, C. Robbins, G.V. Flandem, S.B. Murphy, D. Patch, and S.D. Steppacher Squeaking in total hip replacement: no cause for concern Orthopaedics 31 2008 875 878
-
(2008)
Orthopaedics
, vol.31
, pp. 875-878
-
-
Ecker, T.1
Robbins, C.2
Flandem, G.V.3
Murphy, S.B.4
Patch, D.5
Steppacher, S.D.6
-
6
-
-
48949118899
-
The Noisy Ceramic Hip: Is Component Malpositioning the Cause?
-
DOI 10.1016/j.arth.2008.04.001, PII S0883540308004403
-
C. Restrepo, J. Parvizi, S.M. Kurtz, P.F. Sharkey, W.J. Hozack, and R.H. Rothman The noisy ceramic hip: is component malpositioning the cause? The Journal of Arthroplasty 23 2008 643 649 (Pubitemid 352004114)
-
(2008)
Journal of Arthroplasty
, vol.23
, Issue.5
, pp. 643-649
-
-
Restrepo, C.1
Parvizi, J.2
Kurtz, S.M.3
Sharkey, P.F.4
Hozack, W.J.5
Rothman, R.H.6
-
7
-
-
52249088921
-
The squeaking hip: An underreported phenomenon of ceramic-on-ceramic total hip arthroplasty
-
C.A. Jarrett, A. Ranawat, M. Bruzzone, J. Rodriguez, and C. Ranawat The squeaking hip: an underreported phenomenon of ceramic-on-ceramic total hip arthroplasty Journal of Arthroplasty 22 2007 302
-
(2007)
Journal of Arthroplasty
, vol.22
, pp. 302
-
-
Jarrett, C.A.1
Ranawat, A.2
Bruzzone, M.3
Rodriguez, J.4
Ranawat, C.5
-
9
-
-
0033814067
-
Micro-separation of the centers of aluminaalumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
-
J.E. Nevelos, E. Ingham, C. Doyle, R. Streicher, A. Nevelos, and W. Walter Micro-separation of the centers of aluminaalumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns Journal of Arthroplasty 15 2000 793 795
-
(2000)
Journal of Arthroplasty
, vol.15
, pp. 793-795
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Streicher, R.4
Nevelos, A.5
Walter, W.6
-
10
-
-
0035989715
-
Alumina-alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations
-
DOI 10.1016/S0142-9612(02)00048-0, PII S0142961202000480
-
J.L. Tipper, A. Hatton, J.E. Nevelos, E. Ingham, C. Doyle, and R. Streicher Aluminaalumina artificial hip joints. Part II: characterisation of the wear debris from in vitro hip joint simulations Biomaterials 23 2002 3441 3448 (Pubitemid 34615650)
-
(2002)
Biomaterials
, vol.23
, Issue.16
, pp. 3441-3448
-
-
Tipper, J.L.1
Hatton, A.2
Nevelos, J.E.3
Ingham, E.4
Doyle, C.5
Streicher, R.6
Nevelos, A.B.7
Fisher, J.8
-
11
-
-
0035063689
-
In vivo determination of hip joint separation and the forces generated due to impact loading conditions
-
DOI 10.1016/S0021-9290(00)00239-6, PII S0021929000002396
-
D.A. Dennis, R.D. Komistek, E.J. Northcut, J.A. Ochoa, and A. Ritchie In vivo determination of hip joint separation and the forces generated due to impact loading conditions Journal of Biomechanics 34 2001 623 629 (Pubitemid 32328250)
-
(2001)
Journal of Biomechanics
, vol.34
, Issue.5
, pp. 623-629
-
-
Dennis, D.A.1
Komistek, R.D.2
Northcut, E.J.3
Ochoa, J.A.4
Ritchie, A.5
-
12
-
-
0141535277
-
Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation
-
DOI 10.1016/S0883-5403(03)00204-3
-
T.D. Stewart, J.L. Tipper, G. Insley, R.M. Streicher, E. Ingham, and J. Fisher Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation The Journal of Arthroplasty 18 2003 726 734 (Pubitemid 37176602)
-
(2003)
Journal of Arthroplasty
, vol.18
, Issue.6
, pp. 726-734
-
-
Stewart, T.D.1
Tipper, J.L.2
Insley, G.3
Streicher, R.M.4
Ingham, E.5
Fisher, J.6
-
13
-
-
79960391245
-
Influence of prosthetic design on squeaking after ceramic-on-ceramic total hip arthroplasty
-
Sands EXPO Hall D, Venice
-
Todd VS, Raghavendran S, Peterson DJ, Bliss R, Spellmon C. Influence of prosthetic design on squeaking after ceramic-on-ceramic total hip arthroplasty. In: Proceedings of the AAOS 2009 annual meeting poster presentations. Sands EXPO Hall D, Venice; 2009. p. 979.
-
(2009)
Proceedings of the AAOS 2009 Annual Meeting Poster Presentations
, pp. 979
-
-
Todd, V.S.1
Raghavendran, S.2
Peterson, D.J.3
Bliss, R.4
Spellmon, C.5
-
14
-
-
77954027530
-
Squeak in hip endoprosthesis systems: An experimental study and a numerical technique to analyze design variants
-
C. Weiss, P. Gdaniec, N.P. Hoffmann, A. Hothan, G. Huber, and M.M. Morlock Squeak in hip endoprosthesis systems: an experimental study and a numerical technique to analyze design variants Medical Engineering & Physics 32 2010 604 609
-
(2010)
Medical Engineering & Physics
, vol.32
, pp. 604-609
-
-
Weiss, C.1
Gdaniec, P.2
Hoffmann, N.P.3
Hothan, A.4
Huber, G.5
Morlock, M.M.6
-
15
-
-
77954036006
-
Resonance of the metallic components generates the sound in squeaking ceramic-onceramic hip replacements - An acoustic and finite element analysis
-
Seoul, Korea: ISTA
-
Walter WL, Gillies M, Donohoo S, Sexton SA, Hozack WJ, Ranawat AS. Resonance of the metallic components generates the sound in squeaking ceramic-onceramic hip replacements - an acoustic and finite element analysis. In: Proceedings of the 21st annual congress of the international society for technology in arthroplasty. Seoul, Korea: ISTA; 2008.
-
(2008)
Proceedings of the 21st Annual Congress of the International Society for Technology in Arthroplasty
-
-
Walter, W.L.1
Gillies, M.2
Donohoo, S.3
Sexton, S.A.4
Hozack, W.J.5
Ranawat, A.S.6
-
16
-
-
79960659519
-
Analysis of squeaking on ceramic hip endoprosthesis using the complex eigenvalue method
-
10.1016/j.wear.2010.12.024
-
N. Fan, G.X. Chen, and L.M. Qian Analysis of squeaking on ceramic hip endoprosthesis using the complex eigenvalue method Wear 2011 10.1016/j.wear.2010.12.024
-
(2011)
Wear
-
-
Fan, N.1
Chen, G.X.2
Qian, L.M.3
-
17
-
-
85072487816
-
Analysis of disc brake squeal using finite element methods
-
Liles GD. Analysis of disc brake squeal using finite element methods. SAE Paper 891150; 1989.
-
(1989)
SAE Paper 891150
-
-
Liles, G.D.1
-
20
-
-
38949108840
-
Complex eigenvalue analysis and dynamic transient analysis in predicting disc brake squeal
-
A.R. AbuBakar, and H.-J. Ouyang Complex eigenvalue analysis and dynamic transient analysis in predicting disc brake squeal Vehicle Noise and Vibration 2 2006 143 156
-
(2006)
Vehicle Noise and Vibration
, vol.2
, pp. 143-156
-
-
Abubakar, A.R.1
Ouyang, H.-J.2
-
21
-
-
33947193924
-
Analysis of disc brake squeal using the complex eigenvalue method
-
DOI 10.1016/j.apacoust.2006.03.012, PII S0003682X06000739
-
P. Liu, H. Zheng, C. Cai, Y.Y. Wang, C. Lu, and K.H. Ang Analysis of disc brake squeal using the complex eigenvalue method Applied Acoustics 68 2007 603 615 (Pubitemid 46415689)
-
(2007)
Applied Acoustics
, vol.68
, Issue.6
, pp. 603-615
-
-
Liu, P.1
Zheng, H.2
Cai, C.3
Wang, Y.Y.4
Lu, C.5
Ang, K.H.6
Liu, G.R.7
-
23
-
-
85072448501
-
Advances in complex eigenvalue analysis for brake noise
-
Shi, TS, Dessouki O, Warzecha T, Chang WK, Jayasundera A. Advances in complex eigenvalue analysis for brake noise. SAE Paper 2001-01-1603; 2001.
-
(2001)
SAE Paper 2001-01-1603
-
-
Shi, T.S.1
Dessouki, O.2
Warzecha, T.3
Chang, W.K.4
Jayasundera, A.5
-
26
-
-
4143085921
-
Finite element analysis of femoral components paper III - Hip joints
-
DOI 10.1016/j.matdes.2004.01.009, PII S0261306904000081
-
E. Pyburn, and T. Goswami Finite element analysis of femoral components paper III - hip joints Materials & Design 25 2004 705 713 (Pubitemid 39102799)
-
(2004)
Materials and Design
, vol.25
, Issue.8
, pp. 705-713
-
-
Pyburn, E.1
Goswami, T.2
-
27
-
-
0034984126
-
Hip contact forces and gait patterns from routine activities
-
DOI 10.1016/S0021-9290(01)00040-9, PII S0021929001000409
-
G. Bergmann, G. Deuretzbacher, M. Heller, F. Graichen, A. Rohlmann, and J. Strauss Hip contact forces and gait patterns from routine activities Journal of Biomechanics 34 2001 859 871 (Pubitemid 32530054)
-
(2001)
Journal of Biomechanics
, vol.34
, Issue.7
, pp. 859-871
-
-
Bergmann, G.1
Deuretzbacher, G.2
Heller, M.3
Graichen, F.4
Rohlmann, A.5
Strauss, J.6
Duda, G.N.7
-
28
-
-
79960692963
-
Advances in Friction and Wear Studies of High Performance Ceramics for Hip Joint Prostheses
-
W.J. Si, C.G. Li, and H.Z. Miao Advances in friction and wear studies of high performance ceramics for hip joint prostheses Journal of Materials Science and Engineering 22 2004 424 427 (Pubitemid 39238812)
-
(2004)
Journal of Materials Science and Engineering
, vol.22
, Issue.3
, pp. 424-427
-
-
Si, W.J.1
Li, C.G.2
Miao, H.Z.3
-
29
-
-
77954752003
-
In vitro investigation of friction underedge loading conditions for ceramic-onceramic total hip prosthesis
-
[February 4, Epub ahead of print]
-
E Sariali, T Stewart, Z Jin, and J. Fisher In vitro investigation of friction underedge loading conditions for ceramic-onceramic total hip prosthesis Journal of Orthopaedic Research 2010 [February 4, Epub ahead of print]
-
(2010)
Journal of Orthopaedic Research
-
-
Sariali, E.1
Stewart, T.2
Jin, Z.3
Fisher, J.4
-
30
-
-
77957751124
-
A proposed mechanism for squeaking of ceramiconceramic hips
-
doi:10.1016/j.wear.2010.08.006
-
Currier JH. A proposed mechanism for squeaking of ceramiconceramic hips. Wear 2011, doi:10.1016/j.wear.2010.08.006
-
(2011)
Wear
-
-
Currier, J.H.1
-
31
-
-
79952043319
-
The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations
-
A. Hothan, G. Huber, C. Weiss, N. Hoffmann, and M. Morlock The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations Journal of Biomechanics 44 2011 837 841
-
(2011)
Journal of Biomechanics
, vol.44
, pp. 837-841
-
-
Hothan, A.1
Huber, G.2
Weiss, C.3
Hoffmann, N.4
Morlock, M.5
-
32
-
-
77950900318
-
The effect of stem design on the prevalence of squeaking following ceramic-on-ceramic bearing total hip arthroplasty
-
C. Restrepo, Z.D. Post, B. Kai, and W.J. Hozack The effect of stem design on the prevalence of squeaking following ceramic-on-ceramic bearing total hip arthroplasty The Journal of Bone and Joint Surgery 92 2010 550 557
-
(2010)
The Journal of Bone and Joint Surgery
, vol.92
, pp. 550-557
-
-
Restrepo, C.1
Post, Z.D.2
Kai, B.3
Hozack, W.J.4
-
33
-
-
0037904245
-
Recent applications of viscoelastic damping for noise control in automobiles and commercial airplanes
-
Mohan D. Rao Recent applications of viscoelastic damping for noise control in automobiles and commercial airplanes Journal of Sound and Vibration 262 2003 457 474
-
(2003)
Journal of Sound and Vibration
, vol.262
, pp. 457-474
-
-
Rao, M.D.1
-
34
-
-
0032212854
-
The yielding, plastic flow, and fracture behavior of ultra-high molecular weight polyethylene used in total joint replacements
-
PII S0142961298001124
-
S.M. Kurtz, L. Pruit, C.W. Jewett, R.P. Crawford, D.J. Crane, and A.A. Edidin The yielding, plastic flow, and fracture behavior of ultra-high molecular weight polyethylene used in total joint replacements Biomaterials 19 1998 1989 2003 (Pubitemid 28528801)
-
(1998)
Biomaterials
, vol.19
, Issue.21
, pp. 1989-2003
-
-
Kurtz, S.M.1
Pruitt, L.2
Jewett, C.W.3
Crawford, R.P.4
Crane, D.J.5
Edidin, A.A.6
-
35
-
-
74449092529
-
A non-invasive acoustic and vibration analysis technique for evaluation of hip joint conditions
-
D. Glaser, R.D. Komistek, H.E. Cates, and M.R. Mahfouz A non-invasive acoustic and vibration analysis technique for evaluation of hip joint conditions Journal of Biomechanics 43 2010 426 432
-
(2010)
Journal of Biomechanics
, vol.43
, pp. 426-432
-
-
Glaser, D.1
Komistek, R.D.2
Cates, H.E.3
Mahfouz, M.R.4
|