메뉴 건너뛰기




Volumn 32, Issue 6, 2010, Pages 604-609

Squeak in hip endoprosthesis systems: An experimental study and a numerical technique to analyze design variants

Author keywords

Complex eigenvalue; Hip endoprosthesis; Sliding instability; Squeaking

Indexed keywords

COMPLEX EIGENVALUES; CRITICAL PARAMETER; EFFECTIVE TOOL; ENDOPROSTHESIS; EXPERIMENTAL STUDIES; FINITE ELEMENT MODELING; HIGH FREQUENCY OSCILLATIONS; HIP ENDOPROSTHESIS; INFLUENCE FACTORS; LIMIT-CYCLE; NOISE GENERATION; NUMERICAL APPROACHES; NUMERICAL TECHNIQUES; SELF-EXCITED VIBRATIONS; STABILITY ANALYSIS;

EID: 77954027530     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2010.02.006     Document Type: Article
Times cited : (56)

References (23)
  • 1
    • 38949108840 scopus 로고    scopus 로고
    • Complex eigenvalue analysis and dynamic transient analysis in predicting disc brake squeal
    • AbuBakar A., Ouyang H. Complex eigenvalue analysis and dynamic transient analysis in predicting disc brake squeal. Int J Vehicle Noise Vibrat 2006, 2(2):143-155.
    • (2006) Int J Vehicle Noise Vibrat , vol.2 , Issue.2 , pp. 143-155
    • AbuBakar, A.1    Ouyang, H.2
  • 2
    • 70049108298 scopus 로고    scopus 로고
    • Is ceramic-on-ceramic squeaking phenomenon reproducible in vitro? A long-term simulator study under severe conditions
    • Affato S., Traina F., Mazzega-Fabbro C., Sergo V., Viceconti M. Is ceramic-on-ceramic squeaking phenomenon reproducible in vitro? A long-term simulator study under severe conditions. J Biomed Mater Res B Appl Biomater 2009, 91:264-271.
    • (2009) J Biomed Mater Res B Appl Biomater , vol.91 , pp. 264-271
    • Affato, S.1    Traina, F.2    Mazzega-Fabbro, C.3    Sergo, V.4    Viceconti, M.5
  • 5
    • 1842329805 scopus 로고    scopus 로고
    • Titanium prosthetic wear debris in remote bone marrow. A report of two cases
    • Engh C.A., Moore K.D., Vinh T.N., Engh G.A. Titanium prosthetic wear debris in remote bone marrow. A report of two cases. J Bone Joint Surg [Am] 1997, 79-A:1721-1725.
    • (1997) J Bone Joint Surg [Am] , pp. 1721-1725
    • Engh, C.A.1    Moore, K.D.2    Vinh, T.N.3    Engh, G.A.4
  • 6
    • 0034246120 scopus 로고    scopus 로고
    • Eigensolution of nonclassically damped structures by complex subspace iteration
    • Fischer P. Eigensolution of nonclassically damped structures by complex subspace iteration. Comput Methods Appl Mech Eng 2000, 189(1):149-166.
    • (2000) Comput Methods Appl Mech Eng , vol.189 , Issue.1 , pp. 149-166
    • Fischer, P.1
  • 7
    • 55849087920 scopus 로고    scopus 로고
    • Clicking and squeaking: in vivo correlation of sound and separation for different bearing surfaces
    • Glaser D., Komistek R.D., Cates H.E., Mahfouz M.R. Clicking and squeaking: in vivo correlation of sound and separation for different bearing surfaces. J Bone Joint Surg (Am) 2008, 90:112-120.
    • (2008) J Bone Joint Surg (Am) , vol.90 , pp. 112-120
    • Glaser, D.1    Komistek, R.D.2    Cates, H.E.3    Mahfouz, M.R.4
  • 8
    • 52249088921 scopus 로고    scopus 로고
    • The squeaking hip: an underreported phenomenon of ceramic-on-ceramic total hip arthroplasty
    • Jarrett C.A., Ranawat A., Bruzzone M., Rodriguez J., Ranawat C. The squeaking hip: an underreported phenomenon of ceramic-on-ceramic total hip arthroplasty. J Arthroplasty 2007, 22.
    • (2007) J Arthroplasty , vol.22
    • Jarrett, C.A.1    Ranawat, A.2    Bruzzone, M.3    Rodriguez, J.4    Ranawat, C.5
  • 9
    • 44949094495 scopus 로고    scopus 로고
    • High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings
    • Keurentjes J.C., Kuipers R.M., Wever D.J., Schreurs B.W. High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res 2008, 466:1438-1443.
    • (2008) Clin Orthop Relat Res , vol.466 , pp. 1438-1443
    • Keurentjes, J.C.1    Kuipers, R.M.2    Wever, D.J.3    Schreurs, B.W.4
  • 10
    • 85072467424 scopus 로고    scopus 로고
    • How to play a disc brake: a dissipation-induced squeal. Noise, Vibration
    • Detroit, MI, USA: SAE
    • Kirillov ON. How to play a disc brake: a dissipation-induced squeal. Noise, Vibration, 2008. SP-2158, SAE World Congress, Exhibition, April 2008. Detroit, MI, USA: SAE, p. 167-80.
    • (2008) SP-2158, SAE World Congress, Exhibition, April 2008 , pp. 167-80
    • Kirillov, O.N.1
  • 12
    • 0035215635 scopus 로고    scopus 로고
    • Mismatched wear couple zirconium oxide and aluminium oxide in total hip arthroplasty.
    • Morlock M., Nassutt R., Janssen R., Willmann G., Honl M. Mismatched wear couple zirconium oxide and aluminium oxide in total hip arthroplasty. J Arthroplasty 2001, 16:1071-1074.
    • (2001) J Arthroplasty , vol.16 , pp. 1071-1074
    • Morlock, M.1    Nassutt, R.2    Janssen, R.3    Willmann, G.4    Honl, M.5
  • 13
    • 0033902508 scopus 로고    scopus 로고
    • Brake squeal analysis by finite elements
    • Nack W. Brake squeal analysis by finite elements. Int J Vehicle Des 2000, 23(3-4):263-275.
    • (2000) Int J Vehicle Des , vol.23 , Issue.3-4 , pp. 263-275
    • Nack, W.1
  • 14
    • 58149195513 scopus 로고    scopus 로고
    • Springer, New York, T.D. Rossing (Ed.)
    • Springer handbook of acoustics 2007, Springer, New York. T.D. Rossing (Ed.).
    • (2007) Springer handbook of acoustics
  • 15
    • 72549086280 scopus 로고    scopus 로고
    • Three-dimensional modeling of in vitro hip kinematics under micro-separation regime for ceramic on ceramic total hip prosthesis: An analysis of vibration and noise
    • Sariali E., Stewart T., Jin Z., Fisher J. Three-dimensional modeling of in vitro hip kinematics under micro-separation regime for ceramic on ceramic total hip prosthesis: An analysis of vibration and noise. J Biomech 2010, 43:326-333.
    • (2010) J Biomech , vol.43 , pp. 326-333
    • Sariali, E.1    Stewart, T.2    Jin, Z.3    Fisher, J.4
  • 16
    • 0033631533 scopus 로고    scopus 로고
    • Comparison of friction and lubrication of different hip protheses
    • Scholes S., Unsworth A. Comparison of friction and lubrication of different hip protheses. Proc Inst Mech Eng Part H 2000, 214.
    • (2000) Proc Inst Mech Eng Part H , vol.214
    • Scholes, S.1    Unsworth, A.2
  • 18
    • 0035989715 scopus 로고    scopus 로고
    • Alumina-alumina artificial hip joints. Part ii: characterisation of the wear debris from in vitro hip joint simulations
    • Tipper J., Hatton A., Nevelos J., Ingham E., Doyle C., Streicher R. Alumina-alumina artificial hip joints. Part ii: characterisation of the wear debris from in vitro hip joint simulations. Biomaterials 2002, 23:3441-3448.
    • (2002) Biomaterials , vol.23 , pp. 3441-3448
    • Tipper, J.1    Hatton, A.2    Nevelos, J.3    Ingham, E.4    Doyle, C.5    Streicher, R.6
  • 19
    • 34249933860 scopus 로고    scopus 로고
    • Squeaking in ceramic-on-ceramic hips-the importance of acetabular component orientation
    • Walter W.L., O'Toole G.C., Walter W.K., Ellis A., Zicat B.A. Squeaking in ceramic-on-ceramic hips-the importance of acetabular component orientation. J Arthroplasty 2007, 22(4):496-503.
    • (2007) J Arthroplasty , vol.22 , Issue.4 , pp. 496-503
    • Walter, W.L.1    O'Toole, G.C.2    Walter, W.K.3    Ellis, A.4    Zicat, B.A.5
  • 22
    • 73849109870 scopus 로고    scopus 로고
    • Friction-induced vibration of artificial hip joints
    • Weiss C., Hothan A., Morlock M., Hoffmann N. Friction-induced vibration of artificial hip joints. GAMM-Mitteilungen 2009, 32(2):193-204.
    • (2009) GAMM-Mitteilungen , vol.32 , Issue.2 , pp. 193-204
    • Weiss, C.1    Hothan, A.2    Morlock, M.3    Hoffmann, N.4
  • 23
    • 38449101029 scopus 로고    scopus 로고
    • The squeaking hip: a cause for concern-disagrees
    • Yang C.C., Kim R.H., Dennis D.A. The squeaking hip: a cause for concern-disagrees. Orthopedics 2007, 30:739-742.
    • (2007) Orthopedics , vol.30 , pp. 739-742
    • Yang, C.C.1    Kim, R.H.2    Dennis, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.