메뉴 건너뛰기




Volumn 90, Issue 1, 2012, Pages

Acute electrical stimulation of the human retina with an epiretinal electrode array

Author keywords

acute electrical stimulation; artificial vision; epiretinal electrode array; retina prosthesis; retinal implant; retinitis pigmentosa

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; ELECTROSTIMULATION; EPIRETINAL MICROELECTRODE ARRAY; FEMALE; FILM; FOLLOW UP; GENERATOR; HUMAN; HUMAN TISSUE; INTERVIEW; MALE; MICROELECTRODE; PRIORITY JOURNAL; RETINA; RETINA DEGENERATION; RETINA DETACHMENT; RETINITIS PIGMENTOSA; VISION; VISUAL ACUITY; VITRECTOMY;

EID: 84856525329     PISSN: 1755375X     EISSN: 17553768     Source Type: Journal    
DOI: 10.1111/j.1755-3768.2011.02288.x     Document Type: Article
Times cited : (56)

References (34)
  • 1
    • 79952988118 scopus 로고    scopus 로고
    • Blind subjects implanted with the Argus II retinal prosthesis are able to improve performance in a spatial-motor task
    • Ahuja AK, Dorn JD, Caspi A, et al., (2011): Blind subjects implanted with the Argus II retinal prosthesis are able to improve performance in a spatial-motor task. Br J Ophthalmol 95: 539-543.
    • (2011) Br J Ophthalmol , vol.95 , pp. 539-543
    • Ahuja, A.K.1    Dorn, J.D.2    Caspi, A.3
  • 2
    • 84856541037 scopus 로고    scopus 로고
    • Verification of threshold parameters and tissue compatibility of IrOx film-electrodes on epiretinal electrical stimulation of retina in mini pigs
    • Akguel H, Laube T, Brockmann C, Bolle I, Bornfeld N, Schilling H, &, Luedtke-Handjery HC, (2004): Verification of threshold parameters and tissue compatibility of IrOx film-electrodes on epiretinal electrical stimulation of retina in mini pigs. ARVO Meeting Abstracts 45: 4184.
    • (2004) ARVO Meeting Abstracts , vol.45 , pp. 4184
    • Akguel, H.1    Laube, T.2    Brockmann, C.3    Bolle, I.4    Bornfeld, N.5    Schilling, H.6    Luedtke-Handjery, H.C.7
  • 5
    • 0030826554 scopus 로고    scopus 로고
    • Learning retina implants with epiretinal contacts
    • Eckmiller R, (1997): Learning retina implants with epiretinal contacts. Ophthalmic Res 29: 281-289.
    • (1997) Ophthalmic Res , vol.29 , pp. 281-289
    • Eckmiller, R.1
  • 6
    • 22044457718 scopus 로고    scopus 로고
    • Tunable retina encoders for retina implants: Why and how
    • DOI 10.1088/1741-2560/2/1/011
    • Eckmiller R, Neumann D, &, Baruth O, (2005): Tunable retina encoders for retina implants: why and how. J Neural Eng 2: S91-S104. (Pubitemid 41238013)
    • (2005) Journal of Neural Engineering , vol.2 , Issue.1
    • Eckmiller, R.1    Neumann, D.2    Baruth, O.3
  • 7
    • 23944487226 scopus 로고    scopus 로고
    • Entwicklung einer epiretinalen prothese zur stimulation der humanen netzhaut
    • DOI 10.1007/s00347-005-1186-6
    • Feucht M, Laube T, Bornfeld N, Walter P, Velikay-Parel M, Hornig R, &, Richard G, (2005): Development of an epiretinal proosthesis for stimulation of the human retina. Ophthalmologe 102: 688-691. (Pubitemid 41187212)
    • (2005) Ophthalmologe , vol.102 , Issue.7 , pp. 688-691
    • Feucht, M.1    Laube, T.2    Bornfeld, N.3    Walter, P.4    Velikay-Parel, M.5    Hornig, R.6    Richard, G.7
  • 8
    • 0013515661 scopus 로고
    • Diagnosis and classification of retinitis pigmentosa
    • Heckenlively J.R. (ed.). Philadelphia: J.B. Lippincott.
    • Heckenlively JR, Boughman J, &, Friedman L, (1988): Diagnosis and classification of retinitis pigmentosa. In:, Heckenlively JR, (ed.). Retinitis pigmentosa. Philadelphia: J.B. Lippincott 6-24.
    • (1988) Retinitis Pigmentosa , pp. 6-24
    • Heckenlively, J.R.1    Boughman, J.2    Friedman, L.3
  • 14
    • 0042343861 scopus 로고    scopus 로고
    • Thresholds for activation of rabbit retinal ganglion cells with an ultrafine, extracellular microelectrode
    • DOI 10.1167/iovs.02-1041
    • Jensen RJ, Rizzo JF III, Ziv OR, Grumet A, &, Wyatt J, (2003): Thresholds for activation of rabbit retinal ganglion cells with an ultrafine, extracellular microelectrode. Invest Ophthalmol Vis Sci 44: 3533-3543. (Pubitemid 36909792)
    • (2003) Investigative Ophthalmology and Visual Science , vol.44 , Issue.8 , pp. 3533-3543
    • Jensen, R.J.1    Rizzo III, J.F.2    Ziv, O.R.3    Grumet, A.4    Wyatt, J.5
  • 15
    • 84856538738 scopus 로고    scopus 로고
    • Long term tolerability of the first wireless implant for electrical epiretinal stimulation
    • Keserue M, Post N, Hornig R, Zeitz O, &, Richard G, (2009): Long term tolerability of the first wireless implant for electrical epiretinal stimulation. ARVO Meeting Abstracts 50: 4226.
    • (2009) ARVO Meeting Abstracts , vol.50 , pp. 4226
    • Keserue, M.1    Post, N.2    Hornig, R.3    Zeitz, O.4    Richard, G.5
  • 18
    • 33645403413 scopus 로고    scopus 로고
    • EPI-Ret Group: First time successful epiretinal stimulation with active wireless retinal implants in gottinger minipigs
    • Laube T, Akguel H, Schanze T, Goertz M, Bolle I, Brockmann C, Bornfeld N, & EPI-Ret Group (2004): First time successful epiretinal stimulation with active wireless retinal implants in gottinger minipigs. ARVO Meeting Abstracts 45: 4188.
    • (2004) ARVO Meeting Abstracts , vol.45 , pp. 4188
    • Laube, T.1    Akguel, H.2    Schanze, T.3    Goertz, M.4    Bolle, I.5    Brockmann, C.6    Bornfeld, N.7
  • 21
    • 77952398272 scopus 로고    scopus 로고
    • Cochlear implants and spoken language processing abilities: Review and assessment of the literature
    • Peterson NR, Pisoni DB, &, Miyamoto RT, (2010): Cochlear implants and spoken language processing abilities: review and assessment of the literature. Restor Neurol Neurosci 28: 237-250.
    • (2010) Restor Neurol Neurosci , vol.28 , pp. 237-250
    • Peterson, N.R.1    Pisoni, D.B.2    Miyamoto, R.T.3
  • 23
    • 0345014794 scopus 로고    scopus 로고
    • Methods and Perceptual Thresholds for Short-Term Electrical Stimulation of Human Retina with Microelectrode Arrays
    • DOI 10.1167/iovs.02-0819
    • Rizzo JF III, Wyatt J, Loewenstein J, Kelly S, &, Shire D, (2003a): Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode arrays. Invest Ophthalmol Vis Sci 44: 5355-5361. (Pubitemid 37475410)
    • (2003) Investigative Ophthalmology and Visual Science , vol.44 , Issue.12 , pp. 5355-5361
    • Rizzo III, J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 24
    • 0345445897 scopus 로고    scopus 로고
    • Perceptual Efficacy of Electrical Stimulation of Human Retina with a Microelectrode Array during Short-Term Surgical Trials
    • DOI 10.1167/iovs.02-0817
    • Rizzo JF III, Wyatt J, Loewenstein J, Kelly S, &, Shire D, (2003b): Perceptual efficacy of electrical stimulation of human retina with a microelectrode array during short-term surgical trials. Invest Ophthalmol Vis Sci 44: 5362-5369. (Pubitemid 37475411)
    • (2003) Investigative Ophthalmology and Visual Science , vol.44 , Issue.12 , pp. 5362-5369
    • Rizzo III, J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 25
    • 0002027562 scopus 로고
    • Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation
    • Agnew W.F. McCreery D.B. (eds.). Englewood Cliffs: Prentice Hall.
    • Robblee L, &, Rose TL, (1990): Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation. In:, Agnew WF, McCreery DB, (eds.). Neural Prostheses Fundamental Studies. Englewood Cliffs: Prentice Hall 25-66.
    • (1990) Neural Prostheses Fundamental Studies , pp. 25-66
    • Robblee, L.1    Rose, T.L.2
  • 26
    • 66849137925 scopus 로고    scopus 로고
    • Implantation and explantation of a wireless epiretinal retina implant device: Observations during the EPIRET3 prospective clinical trial
    • Roessler G, Laube T, Brockmann C, et al., (2009): Implantation and explantation of a wireless epiretinal retina implant device: observations during the EPIRET3 prospective clinical trial. Invest Ophthalmol Vis Sci 50: 3003-3008.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 3003-3008
    • Roessler, G.1    Laube, T.2    Brockmann, C.3
  • 29
    • 0026460822 scopus 로고
    • Morphometric analysis of macular photoreceptors and ganglion cells in retinas with retinitis pigmentosa
    • Stone JL, Barlow WE, Humayun MS, de Juan E Jr, &, Milam AH, (1992): Morphometric analysis of macular photoreceptors and ganglion cells in retinas with retinitis pigmentosa. Arch Ophthalmol 110: 1634-1639.
    • (1992) Arch Ophthalmol , vol.110 , pp. 1634-1639
    • Stone, J.L.1    Barlow, W.E.2    Humayun, M.S.3    De Juan, Jr.E.4    Milam, A.H.5
  • 31
    • 79960749058 scopus 로고    scopus 로고
    • Spatial resolution and perception of patterns mediated by a subretinal 16-electrode array in patients blinded by hereditary retinal dystrophies
    • Wilke R, Gabel VP, Sachs H, et al., (2011): Spatial resolution and perception of patterns mediated by a subretinal 16-electrode array in patients blinded by hereditary retinal dystrophies. Invest Ophthalmol Vis Sci 52: 5995-6003.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 5995-6003
    • Wilke, R.1    Gabel, V.P.2    Sachs, H.3
  • 33
    • 0037039812 scopus 로고    scopus 로고
    • Will retinal implants restore vision?
    • DOI 10.1126/science.1067996
    • Zrenner E, (2002): Will retinal implants restore vision? Science 295: 1022-1025. (Pubitemid 34132221)
    • (2002) Science , vol.295 , Issue.5557 , pp. 1022-1025
    • Zrenner, E.1
  • 34
    • 79952692042 scopus 로고    scopus 로고
    • Subretinal electronic chips allow blind patients to read letters and combine them to words
    • Zrenner E, Bartz-Schmidt KU, Benav H, et al., (2011): Subretinal electronic chips allow blind patients to read letters and combine them to words. Proc Biol Sci 278: 1489-1497.
    • (2011) Proc Biol Sci , vol.278 , pp. 1489-1497
    • Zrenner, E.1    Bartz-Schmidt, K.U.2    Benav, H.3