Volumn 11, Issue 5, 2011, Pages 537-544

Integrated microfluidic preconcentrator and immunobiosensor

Author keywords

Liposomes; Microfluidic biosensor; Porous membrane; Preconcentration

Indexed keywords

BINDING SYSTEMS; BIOTIN-STREPTAVIDIN; DEVICE PERFORMANCE; DYE MOLECULE; FLUORESCENCE DETECTION; IN-SITU; INTEGRATED SYSTEMS; MICROFLUIDIC BIOSENSOR; MICROFLUIDIC BIOSENSORS; MODEL SYSTEM; ORDERS OF MAGNITUDE; POROUS MEMBRANES; PRE-CONCENTRATION; PRE-CONCENTRATOR; SIEVING EFFECTS; SIGNAL AMPLIFICATIONS; STREPTAVIDIN; SULFORHODAMINE B;

EID: 84855959917     PISSN: 16134982     EISSN: 16134990     Source Type: Journal    
DOI: 10.1007/s10404-011-0819-0     Document Type: Article
Times cited : (10)

References (46)
  • 2
    • 66149119779 scopus 로고    scopus 로고
    • Integrated capture, concentration, polymerase chain reaction, and capillary electrophoretic analysis of pathogens on a chip
    • Beyor N, Yi L, Seo TS, Mathies RA (2009) Integrated capture, concentration, polymerase chain reaction, and capillary electrophoretic analysis of pathogens on a chip. Anal Chem 81(9): 3523-3528
    • (2009) Anal Chem , vol.81 , Issue.9 , pp. 3523-3528
    • Beyor, N.1    Yi, L.2    Seo, T.S.3    Mathies, R.A.4
  • 3
    • 0035146289 scopus 로고    scopus 로고
    • Continuous concentration of bacteria in a microfluidic flow cell using electrokinetic techniques
    • Cabrera CR, Yager P (2001) Continuous concentration of bacteria in a microfluidic flow cell using electrokinetic techniques. Electrophoresis 22(2):355-362
    • (2001) Electrophoresis , vol.22 , Issue.2 , pp. 355-362
    • Cabrera, C.R.1    Yager, P.2
  • 6
    • 45849140049 scopus 로고    scopus 로고
    • Universal liposomes: Preparation and usage for the detection of mRNA
    • Edwards K, Curtis K, Sailor J, Baeumner A (2008) Universal liposomes: preparation and usage for the detection of mRNA. Anal Bioanal Chem 391(5):1689-1702
    • (2008) Anal Bioanal Chem , vol.391 , Issue.5 , pp. 1689-1702
    • Edwards, K.1    Curtis, K.2    Sailor, J.3    Baeumner, A.4
  • 7
    • 11844255702 scopus 로고    scopus 로고
    • Preconcentration of proteins on microfluidic devices using porous silica membranes
    • DOI 10.1021/ac049136w
    • Foote RS, Khandurina J, Jacobson SC, Ramsey JM (2005) Preconcentration of proteins on microfluidic devices using porous silica membranes. Anal Chem 77(1):57-63 (Pubitemid 40096668)
    • (2005) Analytical Chemistry , vol.77 , Issue.1 , pp. 57-63
    • Foote, R.S.1    Khandurina, J.2    Jacobson, S.C.3    Ramsey, J.M.4
  • 9
    • 33746220287 scopus 로고    scopus 로고
    • Integrated preconcentration SDS-PAGE of proteins in microchips using photopatterned cross-linked polyacrylamide gels
    • DOI 10.1021/ac0600454
    • Hatch AV, Herr AE, Throckmorton DJ, Brennan JS, Singh AK (2006) Integrated preconcentration SDS-PAGE of proteins in microchips using photopatterned cross-linked polyacrylamide gels. Anal Chem 78(14):4976-4984 (Pubitemid 44100633)
    • (2006) Analytical Chemistry , vol.78 , Issue.14 , pp. 4976-4984
    • Hatch, A.V.1    Herr, A.E.2    Throckmorton, D.J.3    Brennan, J.S.4    Singh, A.K.5
  • 11
    • 0014159493 scopus 로고
    • Free zone electrophoresis
    • Hjerten S (1967) Free zone electrophoresis. Chromatogr Rev 9(2): 122-219
    • (1967) Chromatogr Rev , vol.9 , Issue.2 , pp. 122-219
    • Hjerten, S.1
  • 12
    • 46549101119 scopus 로고
    • High-performance electrophoresis. Elimination of electroendosmosis and solute adsorption
    • Hjerten S (1985) High-performance electrophoresis. Elimination of electroendosmosis and solute adsorption. J Chromatogr 347(2): 191-198
    • (1985) J Chromatogr , vol.347 , Issue.2 , pp. 191-198
    • Hjerten, S.1
  • 13
    • 0025815236 scopus 로고
    • Estimation of polyacrylamide gel pore size from Ferguson plots of linear DNA fragments. II. Comparison of gels with different crosslinker concentrations, added agarose and added linear polyacrylamide
    • Holmes DL, Stellwagen NC (1991a) Estimation of polyacrylamide gel pore size from Ferguson plots of linear DNA fragments. II. Comparison of gels with different crosslinker concentrations, added agarose and added linear polyacrylamide. Electrophoresis 12(9):612-619
    • (1991) Electrophoresis , vol.12 , Issue.9 , pp. 612-619
    • Holmes, D.L.1    Stellwagen, N.C.2
  • 14
    • 0025876931 scopus 로고
    • Estimation of polyacrylamide gel pore size from Ferguson plots of normal and anomalously migrating DNA fragments. I. Gels containing 3% N,N0-methylenebisacrylamide
    • Holmes DL, Stellwagen NC (1991b) Estimation of polyacrylamide gel pore size from Ferguson plots of normal and anomalously migrating DNA fragments. I. Gels containing 3% N,N0-methylenebisacrylamide. Electrophoresis 12(4):253-263
    • (1991) Electrophoresis , vol.12 , Issue.4 , pp. 253-263
    • Holmes, D.L.1    Stellwagen, N.C.2
  • 15
    • 0036810809 scopus 로고    scopus 로고
    • An integrated solid-phase extraction system for sub-picomolar detection
    • DOI 10.1002/1522-2683(200210)23:20<3537::AID-ELPS3537>3.0.CO;2-9
    • Jemere AB, Oleschuk RD, Ouchen F, Fajuyigbe F, Harrison DJ (2002) An integrated solid-phase extraction system for subpicomolar detection. Electrophoresis 23(20):3537-3544 (Pubitemid 35363897)
    • (2002) Electrophoresis , vol.23 , Issue.20 , pp. 3537-3544
    • Jemere, A.B.1    Oleschuk, R.D.2    Ouchen, F.3    Fajuyigbe, F.4    Harrison, D.J.5
  • 16
    • 0346504009 scopus 로고    scopus 로고
    • Thousandfold signal increase using field-amplified sample stacking for on-chip electrophoresis
    • Jung B, Bharadwaj R, Santiago JG (2003) Thousandfold signal increase using field-amplified sample stacking for on-chip electrophoresis. Electrophoresis 24(19-20):3476-3483 (Pubitemid 38089151)
    • (2003) Electrophoresis , vol.24 , Issue.19-20 , pp. 3476-3483
    • Jung, B.1    Bharadwaj, R.2    Santiago, J.G.3
  • 17
    • 33645688547 scopus 로고    scopus 로고
    • On-chip millionfold sample stacking using transient isotachophoresis
    • Jung B, Bharadwaj R, Santiago JG (2006) On-chip millionfold sample stacking using transient isotachophoresis. Anal Chem 78(7): 2319-2327
    • (2006) Anal Chem , vol.78 , Issue.7 , pp. 2319-2327
    • Jung, B.1    Bharadwaj, R.2    Santiago, J.G.3
  • 18
    • 0033135930 scopus 로고    scopus 로고
    • Microfabricated porous membrane structure for sample concentration and electrophoretic analysis
    • DOI 10.1021/ac981161c
    • Khandurina J, Jacobson SC, Waters LC, Foote RS, Ramsey JM (1999) Microfabricated porous membrane structure for sample concentration and electrophoretic analysis. Anal Chem 71(9):1815-1819 (Pubitemid 29222178)
    • (1999) Analytical Chemistry , vol.71 , Issue.9 , pp. 1815-1819
    • Khandurina, J.1    Jacobson, S.C.2    Waters, L.C.3    Foote, R.S.4    Ramsey, J.M.5
  • 20
    • 51949109061 scopus 로고    scopus 로고
    • Self-sealed vertical polymeric nanoporousjunctions for high-throughput nanofluidic applications
    • (Erratum to document cited in CA148: 373127)
    • Kim SJ, Han J (2008) Self-sealed vertical polymeric nanoporousjunctions for high-throughput nanofluidic applications. Anal Chem 80(18):7179 (Erratum to document cited in CA148: 373127)
    • (2008) Anal Chem , vol.80 , Issue.18 , pp. 7179
    • Kim, S.J.1    Han, J.2
  • 22
    • 32944474840 scopus 로고    scopus 로고
    • Kinetics of antigen binding to antibody microspots: Strong limitation by mass transport to the surface
    • DOI 10.1002/pmic.200500149
    • Kusnezow W, Syagailo YV, Rueffer S, Klenin K, Sebald W, Hoheisel JD, Gauer C, Goychuk I (2006) Kinetics of antigen binding to antibody microspots: strong limitation by mass transport to the surface. Proteomics 6(3):794-803 (Pubitemid 43260205)
    • (2006) Proteomics , vol.6 , Issue.3 , pp. 794-803
    • Kusnezow, W.1    Syagailo, Y.V.2    Ruffer, S.3    Klenin, K.4    Sebald, W.5    Hoheisel, J.D.6    Gauer, C.7    Goychuk, I.8
  • 23
    • 33947694635 scopus 로고    scopus 로고
    • An embedded system for portable electrochemical detection
    • DOI 10.1016/j.snb.2006.08.032, PII S0925400506005764
    • Kwakye S, Baeumner A (2007) An embedded system for portable electrochemical detection. Sens Actuators B B123(1):336-343 (Pubitemid 46497711)
    • (2007) Sensors and Actuators, B: Chemical , vol.123 , Issue.1 , pp. 336-343
    • Kwakye, S.1    Baeumner, A.2
  • 24
    • 33646108614 scopus 로고    scopus 로고
    • Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat
    • Kwakye S, Goral VN, Baeumner AJ (2006) Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat. Biosens Bioelectron 21(12):2217-2223
    • (2006) Biosens Bioelectron , vol.21 , Issue.12 , pp. 2217-2223
    • Kwakye, S.1    Goral, V.N.2    Baeumner, A.J.3
  • 27
    • 0037265813 scopus 로고    scopus 로고
    • Dynamic analyte introduction and focusing in plastic microfluidic devices for proteomic analysis
    • Li Y, De Voe DL, Lee CS (2003) Dynamic analyte introduction and focusing in plastic microfluidic devices for proteomic analysis. Electrophoresis 24(1-2):193-199 (Pubitemid 36175869)
    • (2003) Electrophoresis , vol.24 , Issue.1-2 , pp. 193-199
    • Li, Y.1    DeVoe, D.L.2    Lee, C.S.3
  • 28
    • 0035145458 scopus 로고    scopus 로고
    • Sample preconcentration by field amplification stacking for microchip-based capillary electrophoresis
    • Lichtenberg J, Verpoorte E, de Rooij NF (2001) Sample preconcentration by field amplification stacking for microchip-based capillary electrophoresis. Electrophoresis 22(2):258-271
    • (2001) Electrophoresis , vol.22 , Issue.2 , pp. 258-271
    • Lichtenberg, J.1    Verpoorte, E.2    De Rooij, N.F.3
  • 29
    • 69749114367 scopus 로고    scopus 로고
    • Integrated microfluidic systems for highperformance genetic analysis
    • Liu P, Mathies RA (2009) Integrated microfluidic systems for highperformance genetic analysis. Trends Biotechnol 27(10):572-581
    • (2009) Trends Biotechnol , vol.27 , Issue.10 , pp. 572-581
    • Liu, P.1    Mathies, R.A.2
  • 30
    • 70849107695 scopus 로고    scopus 로고
    • Microfluidic systems for pathogen sensing: A review
    • Mairhofer J, Roppert K, Ertl P (2009) Microfluidic systems for pathogen sensing: a review. Sensors 9(6):4804-4823
    • (2009) Sensors , vol.9 , Issue.6 , pp. 4804-4823
    • Mairhofer, J.1    Roppert, K.2    Ertl, P.3
  • 31
    • 77749342978 scopus 로고    scopus 로고
    • Simultaneous concentration and separation of microorganisms: Insulatorbased dielectrophoretic approach
    • Moncada-Hernandez H, Lapizco-Encinas BH (2010) Simultaneous concentration and separation of microorganisms: insulatorbased dielectrophoretic approach. Anal Bioanal Chem 396(5): 1805-1816
    • (2010) Anal Bioanal Chem , vol.396 , Issue.5 , pp. 1805-1816
    • Moncada-Hernandez, H.1    Lapizco-Encinas, B.H.2
  • 32
    • 77954758505 scopus 로고    scopus 로고
    • Numerical analysis of a magnetic nanoparticle-enhanced microfluidic surface-based bioassay
    • Munir A, Wang J, Li Z, Zhou HS (2010) Numerical analysis of a magnetic nanoparticle-enhanced microfluidic surface-based bioassay. Microfluid Nanofluid 8(5):641-652
    • (2010) Microfluid Nanofluid , vol.8 , Issue.5 , pp. 641-652
    • Munir, A.1    Wang, J.2    Li, Z.3    Zhou, H.S.4
  • 33
    • 59249092120 scopus 로고    scopus 로고
    • Microfluidics: Applications for analytical purposes in chemistry and biochemistry
    • Ohno K-I, Tachikawa K, Manz A (2008) Microfluidics: applications for analytical purposes in chemistry and biochemistry. Electrophoresis 29(22):4443-4453
    • (2008) Electrophoresis , vol.29 , Issue.22 , pp. 4443-4453
    • Ohno, K.-I.1    Tachikawa, K.2    Manz, A.3
  • 34
    • 27144481918 scopus 로고    scopus 로고
    • Integrated microfluidic device for solid-phase extraction coupled to micellar electrokinetic chromatography separation
    • DOI 10.1021/ac0507789
    • Ramsey JD, Collins GE (2005) Integrated microfluidic device for solid-phase extraction coupled to micellar electrokinetic chromatography separation. Anal Chem 77(20):6664-6670 (Pubitemid 41504451)
    • (2005) Analytical Chemistry , vol.77 , Issue.20 , pp. 6664-6670
    • Ramsey, J.D.1    Collins, G.E.2
  • 35
    • 0026445903 scopus 로고
    • Binding kinetics of antigen by immobilized antibody: Influence of reaction order and external diffusional limitations
    • Sadana A, Sii D (1992) Binding kinetics of antigen by immobilized antibody: influence of reaction order and external diffusional limitations. Biosens Bioelectron 7(8):559-568
    • (1992) Biosens Bioelectron , vol.7 , Issue.8 , pp. 559-568
    • Sadana, A.1    Sii, D.2
  • 36
    • 0027375108 scopus 로고
    • Liposome immunomigration field assay device for Alachlor determination
    • DOI 10.1016/0003-2670(93)80214-6
    • Siebert STA, Reeves SG, Durst RA (1993) Liposome immunomigration field assay device for alachlor determination. Anal Chim Acta 282(2):297-305 (Pubitemid 23300301)
    • (1993) Analytica Chimica Acta , vol.282 , Issue.2 , pp. 297-305
    • Siebert, S.T.A.1    Reeves, S.G.2    Durst, R.A.3
  • 38
    • 3543026311 scopus 로고    scopus 로고
    • Electrophoretic concentration of proteins at laser-patterned nanoporous membranes in microchips
    • DOI 10.1021/ac0497151
    • Song S, Singh AK, Kirby BJ (2004a) Electrophoretic concentration of proteins at laser-patterned nanoporous membranes in microchips. Anal Chem 76(15):4589-4592 (Pubitemid 39014039)
    • (2004) Analytical Chemistry , vol.76 , Issue.15 , pp. 4589-4592
    • Song, S.1    Singh, A.K.2    Kirby, B.J.3
  • 39
    • 1942422755 scopus 로고    scopus 로고
    • Microchip dialysis of proteins using in situ photopatterned nanoporous polymer membranes
    • DOI 10.1021/ac035290r
    • Song S, Singh AK, Shepodd TJ, Kirby BJ (2004b) Microchip dialysis of proteins using in situ photopatterned nanoporous polymer membranes. Anal Chem 76(8):2367-2373 (Pubitemid 38496080)
    • (2004) Analytical Chemistry , vol.76 , Issue.8 , pp. 2367-2373
    • Song, S.1    Singh, A.K.2    Shepodd, T.J.3    Kirby, B.J.4
  • 40
    • 0036810852 scopus 로고    scopus 로고
    • Miniaturized capillary isoelectric focusing in plastic microfluidic devices
    • DOI 10.1002/1522-2683(200210)23:20<3638::AID-ELPS3638>3.0.CO;2-Y
    • Tan W, Fan ZH, Qiu CX, Ricco AJ, Gibbons I (2002) Miniaturized capillary isoelectric focusing in plastic microfluidic devices. Electrophoresis 23(20):3638-3645 (Pubitemid 35363910)
    • (2002) Electrophoresis , vol.23 , Issue.20 , pp. 3638-3645
    • Tan, W.1    Fan, Z.H.2    Qiu, C.X.3    Ricco, A.J.4    Gibbons, I.5
  • 41
    • 0037032630 scopus 로고    scopus 로고
    • Sample pre-concentration by isotachophoresis in microfluidic devices
    • DOI 10.1016/S0021-9673(02)01246-3, PII S0021967302012463
    • Wainright A, Williams SJ, Ciambrone G, Xue Q, Wei J, Harris D (2002) Sample pre-concentration by isotachophoresis in microfluidic devices. J Chromatogr A 979(1-2):69-80 (Pubitemid 35341528)
    • (2002) Journal of Chromatography A , vol.979 , Issue.1-2 , pp. 69-80
    • Wainright, A.1    Williams, S.J.2    Ciambrone, G.3    Xue, Q.4    Wei, J.5    Harris, D.6
  • 42
    • 40049112986 scopus 로고    scopus 로고
    • Pre-binding dynamic range and sensitivity enhancement for immuno-sensors using nanofluidic preconcentrator
    • DOI 10.1039/b717220f
    • Wang Y-C, Han J (2008) Pre-binding dynamic range and sensitivity enhancement for immuno-sensors using nanofluidic preconcentrator. Lab Chip 8(3):392-394 (Pubitemid 351324738)
    • (2008) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.8 , Issue.3 , pp. 392-394
    • Wang, Y.-C.1    Han, J.2
  • 44
    • 24744433042 scopus 로고    scopus 로고
    • Million-fold preconcentration of proteins and peptides by nanofluidic filter
    • DOI 10.1021/ac050321z
    • Wang Y-C, Stevens AL, Han J (2005) Million-fold preconcentration of proteins and peptides by nanofluidic filter. Anal Chem 77(14):4293-4299 (Pubitemid 41542245)
    • (2005) Analytical Chemistry , vol.77 , Issue.14 , pp. 4293-4299
    • Wang, Y.-C.1    Stevens, A.L.2    Han, J.3
  • 45
    • 70450085156 scopus 로고    scopus 로고
    • Exceeding 20 000-fold concentration of protein by the on-line isotachophoresis concentration in poly(methyl methacrylate) microchip
    • Wang J, Zhang Y, Mohamadi MR, Kaji N, Tokeshi M, Baba Y (2009) Exceeding 20 000-fold concentration of protein by the on-line isotachophoresis concentration in poly(methyl methacrylate) microchip. Electrophoresis 30(18):3250-3256
    • (2009) Electrophoresis , vol.30 , Issue.18 , pp. 3250-3256
    • Wang, J.1    Zhang, Y.2    Mohamadi, M.R.3    Kaji, N.4    Tokeshi, M.5    Baba, Y.6
  • 46
    • 0035500025 scopus 로고    scopus 로고
    • Monolithic porous polymer for on-chip solid-phase extraction and preconcentration prepared by photoinitiated in situ polymerization within a microfluidic device
    • DOI 10.1021/ac0106288
    • Yu C, Davey MH, Svec F, Frechet JMJ (2001) Monolithic porous polymer for on-chip solid-phase extraction and preconcentration prepared by photoinitiated in situ polymerization within a microfluidic device. Anal Chem 73(21):5088-5096 (Pubitemid 33032222)
    • (2001) Analytical Chemistry , vol.73 , Issue.21 , pp. 5088-5096
    • Yu, C.1    Davey, M.H.2    Svec, F.3    Frechet, J.M.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.