메뉴 건너뛰기




Volumn 123, Issue 1, 2007, Pages 336-343

An embedded system for portable electrochemical detection

Author keywords

Amperometry; Biosensors; Embedded systems; Microcontrollers; Potentiostat

Indexed keywords

AMPEROMETRIC SENSORS; BIOSENSORS; ELECTROCHEMICAL SENSORS; LIQUID CRYSTAL DISPLAYS; MICROCONTROLLERS; SENSOR ARRAYS;

EID: 33947694635     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2006.08.032     Document Type: Article
Times cited : (37)

References (22)
  • 1
    • 1842477059 scopus 로고    scopus 로고
    • Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection
    • Liu R.H., Yang J., Lenigk R., Bonanno J., and Grodzinski P. Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection. Anal. Chem. 76 (2004) 1824-1831
    • (2004) Anal. Chem. , vol.76 , pp. 1824-1831
    • Liu, R.H.1    Yang, J.2    Lenigk, R.3    Bonanno, J.4    Grodzinski, P.5
  • 2
    • 0029917196 scopus 로고    scopus 로고
    • Portable device for continuous fractionated blood sampling and continuous ex vivo blood glucose monitoring
    • Trajanoski Z., Wach P., and Gfrerer R. Portable device for continuous fractionated blood sampling and continuous ex vivo blood glucose monitoring. Biosens. Bioelectron. 11 5 (1996) 479-487
    • (1996) Biosens. Bioelectron. , vol.11 , Issue.5 , pp. 479-487
    • Trajanoski, Z.1    Wach, P.2    Gfrerer, R.3
  • 3
    • 22944444177 scopus 로고    scopus 로고
    • A new handheld biosensor for monitoring blood ketones
    • Li G., Ma N.Z., and Wang Y. A new handheld biosensor for monitoring blood ketones. Sens. Actuators B 109 (2005) 285-290
    • (2005) Sens. Actuators B , vol.109 , pp. 285-290
    • Li, G.1    Ma, N.Z.2    Wang, Y.3
  • 4
    • 0032802671 scopus 로고    scopus 로고
    • Field-portable capillary electrophoresis instrument with potentiometric and amperometric detection
    • Kappes T., Schnierle P., and Hauser P.C. Field-portable capillary electrophoresis instrument with potentiometric and amperometric detection. Anal. Chim. Acta 393 (1999) 77-82
    • (1999) Anal. Chim. Acta , vol.393 , pp. 77-82
    • Kappes, T.1    Schnierle, P.2    Hauser, P.C.3
  • 5
    • 0344845249 scopus 로고    scopus 로고
    • Portable instrument for electrochemical gas sensing
    • Knake R., and Hauser P.C. Portable instrument for electrochemical gas sensing. Anal. Chim. Acta 500 (2003) 145-153
    • (2003) Anal. Chim. Acta , vol.500 , pp. 145-153
    • Knake, R.1    Hauser, P.C.2
  • 6
    • 0036022309 scopus 로고    scopus 로고
    • Evaluation of the i-STAT portable clinical analyzer for point-of-care blood testing in the intensive care units of a university children's hospital
    • Papadea C., Foster J., Grant S., Ballard S.A., Cate IV J.C., Southgate W.M., and Purohit D.M. Evaluation of the i-STAT portable clinical analyzer for point-of-care blood testing in the intensive care units of a university children's hospital. Ann. Clin. Lab. Sci. 32 3 (2002) 231-243
    • (2002) Ann. Clin. Lab. Sci. , vol.32 , Issue.3 , pp. 231-243
    • Papadea, C.1    Foster, J.2    Grant, S.3    Ballard, S.A.4    Cate IV, J.C.5    Southgate, W.M.6    Purohit, D.M.7
  • 8
    • 33947624939 scopus 로고    scopus 로고
    • M. Bourne, 2005 may be a momentous year for MEMS, or maybe just a momentum-building year, Small Times: News About MEMS, Nanotechnology and Microsystems, January 21, 2005, http://www.smalltimes.com/
  • 10
    • 0031788179 scopus 로고    scopus 로고
    • Trends in electrochemical sensors
    • Manger E. Trends in electrochemical sensors. Analyst 123 (1998) 1967-1970
    • (1998) Analyst , vol.123 , pp. 1967-1970
    • Manger, E.1
  • 14
    • 11144278573 scopus 로고    scopus 로고
    • Wide-range, picoampere-sensitivity multichannel VLSI potentiostat for neurotransmitter sensing
    • IEEE Engineering in Medicine and Biology Society (EMBS'2004), San Francisco, September 1-4
    • Murari K., Thakor N., Stanacevic M., and Cauwenberghs G. Wide-range, picoampere-sensitivity multichannel VLSI potentiostat for neurotransmitter sensing. Proceedings of the 26th Annual International Conference. IEEE Engineering in Medicine and Biology Society (EMBS'2004), San Francisco, September 1-4 (2004)
    • (2004) Proceedings of the 26th Annual International Conference
    • Murari, K.1    Thakor, N.2    Stanacevic, M.3    Cauwenberghs, G.4
  • 15
    • 1642478037 scopus 로고    scopus 로고
    • A micropower amperometric potentiostat
    • Steinberg M.D., and Lowe C.R. A micropower amperometric potentiostat. Sens. Actuators B: Chem. 97 2-3 (2004) 284-289
    • (2004) Sens. Actuators B: Chem. , vol.97 , Issue.2-3 , pp. 284-289
    • Steinberg, M.D.1    Lowe, C.R.2
  • 16
    • 18544371306 scopus 로고    scopus 로고
    • Construction and analytical applications of a palm-sized microcontroller-based amperometric analyzer
    • Avdikos E.M., Prodromidis M.I., and Efstathiou C.E. Construction and analytical applications of a palm-sized microcontroller-based amperometric analyzer. Sens. Actuators B: Chem. 107 (2005) 372-378
    • (2005) Sens. Actuators B: Chem. , vol.107 , pp. 372-378
    • Avdikos, E.M.1    Prodromidis, M.I.2    Efstathiou, C.E.3
  • 17
    • 33646108614 scopus 로고    scopus 로고
    • Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat
    • Kwakye S., Baeumner A.J., and Goral V.N. Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat. Biosens. Bioelectron. 21 12 (2006) 2217-2223
    • (2006) Biosens. Bioelectron. , vol.21 , Issue.12 , pp. 2217-2223
    • Kwakye, S.1    Baeumner, A.J.2    Goral, V.N.3
  • 19
    • 4344625171 scopus 로고    scopus 로고
    • Characterization and optimization of interdigitated ultramicroelectrode arrays as electrochemical biosensor transducers
    • Min J.H., and Baeumner A. Characterization and optimization of interdigitated ultramicroelectrode arrays as electrochemical biosensor transducers. Electroanalysis 16 9 (2004) 724-729
    • (2004) Electroanalysis , vol.16 , Issue.9 , pp. 724-729
    • Min, J.H.1    Baeumner, A.2
  • 20
    • 33644644847 scopus 로고    scopus 로고
    • Electrochemical microfluidic biosensor for the detection of nucleic acid sequences
    • Goral V.N., Zaytseva N.V., and Baeumner A.J. Electrochemical microfluidic biosensor for the detection of nucleic acid sequences. Lab Chip 6 (2006) 414-421
    • (2006) Lab Chip , vol.6 , pp. 414-421
    • Goral, V.N.1    Zaytseva, N.V.2    Baeumner, A.J.3
  • 21
    • 33947617672 scopus 로고    scopus 로고
    • Application Note 882, RS-232 Features Explained, Maxim, http://www.maxim-ic.com/appnotes.cfm/appnote_number/882.