메뉴 건너뛰기




Volumn 40, Issue 2, 2012, Pages 123-130

Vertical discrepancy and microleakage of laser-sintered and vacuum-cast implant-supported structures luted with different cement types

Author keywords

Cement retained implant supported prostheses; Laser sintering; Microleakage; Vacuum cast; Vertical discrepancy

Indexed keywords

ALLOY; CHROMIUM DERIVATIVE; GLASS IONOMER; GOLD ALLOY; KETAC CEM; KETAC-CEM; MAGNESIUM OXIDE; PALLADIUM; PANAVIA FLUORO; PANAVIA-FLUORO; POLYCARBOXYLATE CEMENT; RELY X UNICEM; RESIN CEMENT; TOOTH CEMENT; WATER; ZINC OXIDE;

EID: 84855903140     PISSN: 03005712     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jdent.2011.11.007     Document Type: Article
Times cited : (52)

References (45)
  • 3
    • 0024763839 scopus 로고
    • Complications with osseointegrated implants
    • A.D. Sones Complications with osseointegrated implants Journal of Prosthetic Dentistry 62 1989 581 585
    • (1989) Journal of Prosthetic Dentistry , vol.62 , pp. 581-585
    • Sones, A.D.1
  • 4
    • 46949104561 scopus 로고    scopus 로고
    • Growing body of evidence on survival rates of implant-supported fixed prostheses
    • E. Abt Growing body of evidence on survival rates of implant-supported fixed prostheses Evidence Based Dentistry 9 2008 51 52
    • (2008) Evidence Based Dentistry , vol.9 , pp. 51-52
    • Abt, E.1
  • 5
    • 57749196951 scopus 로고    scopus 로고
    • In vitro vertical misfit evaluation of cast frameworks for cement-retained implant-supported partial prostheses
    • R.C. Oyagüe, A.S. Turrión, M. Toledano, F. Monticelli, and R. Osorio In vitro vertical misfit evaluation of cast frameworks for cement-retained implant-supported partial prostheses Journal of Dentistry 37 2009 52 58
    • (2009) Journal of Dentistry , vol.37 , pp. 52-58
    • Oyagüe, R.C.1    Turrión, A.S.2    Toledano, M.3    Monticelli, F.4    Osorio, R.5
  • 6
    • 0026214839 scopus 로고
    • Production of accurately fitting full-arch implant frameworks: Part I. Clinical procedures
    • G.E. Goll Production of accurately fitting full-arch implant frameworks: part I. Clinical procedures Journal of Prosthetic Dentistry 66 1991 377 384
    • (1991) Journal of Prosthetic Dentistry , vol.66 , pp. 377-384
    • Goll, G.E.1
  • 7
    • 70249093688 scopus 로고    scopus 로고
    • The three-dimensional casting distortion of five implant-supported frameworks
    • T. Mitha, C.P. Owen, and D.G. Howes The three-dimensional casting distortion of five implant-supported frameworks International Journal of Prosthodontics 22 2009 248 250
    • (2009) International Journal of Prosthodontics , vol.22 , pp. 248-250
    • Mitha, T.1    Owen, C.P.2    Howes, D.G.3
  • 8
    • 0036550139 scopus 로고    scopus 로고
    • Alloys for prosthodontic restorations
    • DOI 10.1067/mpr.2002.123817
    • J.C. Wataha Alloys for prosthodontic restorations Journal of Prosthetic Dentistry 87 2002 351 363 (Pubitemid 40433957)
    • (2002) Journal of Prosthetic Dentistry , vol.87 , Issue.4 , pp. 351-363
    • Wataha, J.C.1
  • 9
    • 34250633633 scopus 로고    scopus 로고
    • Base metal alloys used for dental restorations and implants
    • M. Roach Base metal alloys used for dental restorations and implants Dental Clinics of North America 51 2007 603 627
    • (2007) Dental Clinics of North America , vol.51 , pp. 603-627
    • Roach, M.1
  • 10
    • 0025408652 scopus 로고
    • Properties of cobalt-chromium metal ceramic alloys after heat treatment
    • H.F. Morris Properties of cobalt-chromium metal ceramic alloys after heat treatment Journal of Prosthetic Dentistry 63 1990 426 433
    • (1990) Journal of Prosthetic Dentistry , vol.63 , pp. 426-433
    • Morris, H.F.1
  • 11
    • 30144443077 scopus 로고    scopus 로고
    • Influence of investment type and sprue number on the casting accuracy of titanium crown margins
    • DOI 10.1016/j.prosdent.2005.11.004, PII S0022391305005846
    • M.B. Leal, S.M. Paulino, V.O. Pagnano, and O.L. Bezzon Influence of investment type and sprue number on the casting accuracy of titanium crown margins Journal of Prosthetic Dentistry 95 2006 42 49 (Pubitemid 43053034)
    • (2006) Journal of Prosthetic Dentistry , vol.95 , Issue.1 , pp. 42-49
    • Leal, M.B.1    Paulino, S.M.2    Pagnano, V.O.3    Bezzon, O.L.4
  • 14
    • 48749087870 scopus 로고    scopus 로고
    • Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology
    • K. Quante, K. Ludwig, and M. Kern Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology Dental Materials 24 2008 1311 1315
    • (2008) Dental Materials , vol.24 , pp. 1311-1315
    • Quante, K.1    Ludwig, K.2    Kern, M.3
  • 15
    • 48749116225 scopus 로고    scopus 로고
    • Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain
    • T. Akova, Y. Ucar, A. Tukay, M.C. Balkaya, and W.A. Brantley Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain Dental Materials 24 2008 1400 1404
    • (2008) Dental Materials , vol.24 , pp. 1400-1404
    • Akova, T.1    Ucar, Y.2    Tukay, A.3    Balkaya, M.C.4    Brantley, W.A.5
  • 16
    • 70349302056 scopus 로고    scopus 로고
    • Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: Laser-sintered Co-Cr crowns
    • Y. Ucar, T. Akova, M.S. Akyil, and W.A. Brantley Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns Journal of Prosthetic Dentistry 102 2009 253 259
    • (2009) Journal of Prosthetic Dentistry , vol.102 , pp. 253-259
    • Ucar, Y.1    Akova, T.2    Akyil, M.S.3    Brantley, W.A.4
  • 17
    • 79952283407 scopus 로고    scopus 로고
    • The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: A comparative in vitro study
    • A. Örtorp, D. Jönsson, A. Mouhsen, and P. Vult von Steyern The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study Dental Materials 27 2011 356 363
    • (2011) Dental Materials , vol.27 , pp. 356-363
    • Örtorp, A.1    Jönsson, D.2    Mouhsen, A.3    Vult Von Steyern, P.4
  • 18
    • 0025452898 scopus 로고
    • A standardized method for determination of crown margin fidelity
    • J.A. Sorensen A standardized method for determination of crown margin fidelity Journal of Prosthetic Dentistry 64 1990 18 24
    • (1990) Journal of Prosthetic Dentistry , vol.64 , pp. 18-24
    • Sorensen, J.A.1
  • 21
    • 34548289824 scopus 로고    scopus 로고
    • Mechanical properties of dual-cured resin luting agents for ceramic restoration
    • K. Yoshida, Y. Tsuo, X. Meng, and M. Atsuta Mechanical properties of dual-cured resin luting agents for ceramic restoration Journal of Prosthodontics 16 2007 370 376
    • (2007) Journal of Prosthodontics , vol.16 , pp. 370-376
    • Yoshida, K.1    Tsuo, Y.2    Meng, X.3    Atsuta, M.4
  • 22
    • 12444251147 scopus 로고    scopus 로고
    • Bonding of an auto-adhesive luting material to enamel and dentin
    • DOI 10.1016/j.dental.2004.03.002, PII S0109564104000338
    • J. De Munck, M. Vargas, K. Van Landuyt, K. Hikita, P. Lambrechts, and B. Van Meerbeek Bonding of an autoadhesive luting material to enamel and dentin Dental Materials 20 2004 963 971 (Pubitemid 40146126)
    • (2004) Dental Materials , vol.20 , Issue.10 , pp. 963-971
    • De Munck, J.1    Vargas, M.2    Van Landuyt, K.3    Hikita, K.4    Lambrechts, P.5    Van Meerbeek, B.6
  • 23
    • 0026902724 scopus 로고
    • Retentive strength, disintegration, and marginal quality of luting cements
    • S. Gorodovsky, and O. Zidan Retentive strength, disintegration, and marginal quality of luting cements Journal of Prosthetic Dentistry 68 1992 269 274
    • (1992) Journal of Prosthetic Dentistry , vol.68 , pp. 269-274
    • Gorodovsky, S.1    Zidan, O.2
  • 25
    • 33748490266 scopus 로고    scopus 로고
    • Comparison of 7 luting protocols and their effect on the retention and marginal leakage of a cement-retained dental implant restoration
    • Y.H. Pan, L.C. Ramp, C.K. Lin, and P.R. Liu Comparison of 7 luting protocols and their effect on the retention and marginal leakage of a cement-retained dental implant restoration International Journal of Oral and Maxillofacial Implants 21 2006 587 592 (Pubitemid 44358681)
    • (2006) International Journal of Oral and Maxillofacial Implants , vol.21 , Issue.4 , pp. 587-592
    • Pan, Y.-H.1    Ramp, L.C.2    Lin, C.-K.3    Liu, P.-R.4
  • 26
    • 0026923379 scopus 로고
    • The effect of seating force on film thickness of new adhesive luting agents
    • S.N. White, Z. Yu, and V. Kipnis The effect of seating force on film thickness of new adhesive luting agents Journal of Prosthetic Dentistry 68 1992 476 481
    • (1992) Journal of Prosthetic Dentistry , vol.68 , pp. 476-481
    • White, S.N.1    Yu, Z.2    Kipnis, V.3
  • 27
    • 0028393551 scopus 로고
    • Influence of marginal opening on microleakage of cemented artificial crowns
    • S.N. White, S. Ingles, and V. Kipnis Influence of marginal opening on microleakage of cemented artificial crowns Journal of Prosthetic Dentistry 71 1994 257 264
    • (1994) Journal of Prosthetic Dentistry , vol.71 , pp. 257-264
    • White, S.N.1    Ingles, S.2    Kipnis, V.3
  • 28
    • 0026478461 scopus 로고
    • Marginal leakage of cast gold crowns luted with an adhesive resin cement
    • A.H. Tjan, J.R. Dunn, and B.E. Grant Marginal leakage of cast gold crowns luted with an adhesive resin cement Journal of Prosthetic Dentistry 67 1992 11 15
    • (1992) Journal of Prosthetic Dentistry , vol.67 , pp. 11-15
    • Tjan, A.H.1    Dunn, J.R.2    Grant, B.E.3
  • 29
    • 77954843912 scopus 로고    scopus 로고
    • Evaluation of fit of zirconia posterior bridge structures constructed with different scanning methods and preparation angles
    • R.C. Oyagüe, M.I. Sánchez-Jorge, and A. Sánchez Turrión Evaluation of fit of zirconia posterior bridge structures constructed with different scanning methods and preparation angles Odontology 98 2010 170 172
    • (2010) Odontology , vol.98 , pp. 170-172
    • Oyagüe, R.C.1    Sánchez-Jorge, M.I.2    Sánchez Turrión, A.3
  • 32
    • 33644920407 scopus 로고    scopus 로고
    • A three-dimensional evaluation of a laser scanner and a touch-probe scanner
    • DOI 10.1016/j.prosdent.2006.01.003, PII S0022391306000321
    • A. Persson, M. Andersson, A. Oden, and G. Sandborgh-Englund A three-dimensional evaluation of a laser scanner and a touch-probe scanner Journal of Prosthetic Dentistry 95 2006 194 200 (Pubitemid 43388110)
    • (2006) Journal of Prosthetic Dentistry , vol.95 , Issue.3 , pp. 194-200
    • Persson, A.1    Andersson, M.2    Oden, A.3    Sandborgh-Englund, G.4
  • 34
    • 72049130266 scopus 로고    scopus 로고
    • A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation
    • E. Gonzalo, M.J. Suárez, B. Serrano, and J.F. Lozano A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation Journal of Prosthetic Dentistry 102 2009 378 384
    • (2009) Journal of Prosthetic Dentistry , vol.102 , pp. 378-384
    • Gonzalo, E.1    Suárez, M.J.2    Serrano, B.3    Lozano, J.F.4
  • 35
    • 0034156664 scopus 로고    scopus 로고
    • Mechanical properties and microstructures of glass-ionomer cements
    • D. Xie, W.A. Brantley, B.M. Culbertson, and G. Wang Mechanical properties and microstructures of glass-ionomer cements Dental Materials 16 2000 129 138
    • (2000) Dental Materials , vol.16 , pp. 129-138
    • Xie, D.1    Brantley, W.A.2    Culbertson, B.M.3    Wang, G.4
  • 36
    • 34548842789 scopus 로고    scopus 로고
    • The influence of cervical finish line, internal relief, and cement type on the cervical adaptation of metal crowns
    • M.A. Bottino, L.F. Valandro, L. Buso, and M. Ozcan The influence of cervical finish line, internal relief, and cement type on the cervical adaptation of metal crowns Quintessence International 38 2007 425 432
    • (2007) Quintessence International , vol.38 , pp. 425-432
    • Bottino, M.A.1    Valandro, L.F.2    Buso, L.3    Ozcan, M.4
  • 37
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted fixed prostheses supported by Brnemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup
    • T. Jemt Failures and complications in 391 consecutively inserted fixed prostheses supported by Brnemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup International Journal of Oral and Maxillofacial Implants 6 1991 270 276
    • (1991) International Journal of Oral and Maxillofacial Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 38
    • 77953707372 scopus 로고    scopus 로고
    • The role of primary stability for successful immediate loading of dental implants. A literature review
    • F. Javed, and G.E. Romanos The role of primary stability for successful immediate loading of dental implants. A literature review Journal of Dentistry 38 2010 612 620
    • (2010) Journal of Dentistry , vol.38 , pp. 612-620
    • Javed, F.1    Romanos, G.E.2
  • 40
    • 80955179543 scopus 로고    scopus 로고
    • Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques
    • M. Baldassarri, Y. Zhang, V.P. Thompson, E.D. Rekow, and C.F. Stappert Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques Journal of Dentistry 39 2011 489 498
    • (2011) Journal of Dentistry , vol.39 , pp. 489-498
    • Baldassarri, M.1    Zhang, Y.2    Thompson, V.P.3    Rekow, E.D.4    Stappert, C.F.5
  • 41
    • 77953707160 scopus 로고    scopus 로고
    • Influence of chromium interlayer on the adhesion of porcelain to machined titanium as determined by the strain energy release rate
    • S.E. Elsaka, I.M. Hamouda, Y.A. Elewady, O.B. Abouelatta, and M.V. Swain Influence of chromium interlayer on the adhesion of porcelain to machined titanium as determined by the strain energy release rate Journal of Dentistry 38 2010 648 654
    • (2010) Journal of Dentistry , vol.38 , pp. 648-654
    • Elsaka, S.E.1    Hamouda, I.M.2    Elewady, Y.A.3    Abouelatta, O.B.4    Swain, M.V.5
  • 42
    • 0031179216 scopus 로고    scopus 로고
    • Cement removal from restorations luted to titanium abutments with simulated subgingival margins
    • J.R. Agar, S.M. Cameron, J.C. Hughbanks, and M.H. Parker Cement removal from restorations luted to titanium abutments with simulated subgingival margins Journal of Prosthetic Dentistry 78 1997 43 47
    • (1997) Journal of Prosthetic Dentistry , vol.78 , pp. 43-47
    • Agar, J.R.1    Cameron, S.M.2    Hughbanks, J.C.3    Parker, M.H.4
  • 44
    • 33845402747 scopus 로고    scopus 로고
    • Tensile bond strength of dual curing resin-based cements to commercially pure titanium
    • DOI 10.1016/j.dental.2005.12.006, PII S0109564105003623
    • R. Schneider, M.F. de Goes, G.E. Henriques, and D.C. Chan Tensile bond strength of dual curing resin-based cements to commercially pure titanium Dental Materials 23 2007 81 87 (Pubitemid 44895424)
    • (2007) Dental Materials , vol.23 , Issue.1 , pp. 81-87
    • Schneider, R.1    Goes, M.F.D.2    Henriques, G.E.P.3    Chan, D.C.N.4
  • 45
    • 0021660117 scopus 로고
    • The competition between the composite-dentin bond strength and the polymerization contraction stress
    • C.L. Davidson, A.J. de Gee, and A. Feilzer The competition between the composite-dentin bond strength and the polymerization contraction stress Journal of Dental Research 63 1984 1396 1399
    • (1984) Journal of Dental Research , vol.63 , pp. 1396-1399
    • Davidson, C.L.1    De Gee, A.J.2    Feilzer, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.