-
1
-
-
0029385307
-
A thousand years of dental implants: a definitive history part 1
-
1060, 1062, 1064
-
Ring M.E. A thousand years of dental implants: a definitive history part 1. Compend Contin Educ Dent 16 10 (1995) 1060, 1062, 1064
-
(1995)
Compend Contin Educ Dent
, vol.16
, Issue.10
-
-
Ring, M.E.1
-
2
-
-
0036986529
-
Orthodontic biomaterials: from the past to the present
-
Kusy R.P. Orthodontic biomaterials: from the past to the present. Angle Orthod 72 6 (2002) 501-512
-
(2002)
Angle Orthod
, vol.72
, Issue.6
, pp. 501-512
-
-
Kusy, R.P.1
-
3
-
-
0030641633
-
An evaluation of casting alloys used for restorative procedures
-
Leinfelder K.F. An evaluation of casting alloys used for restorative procedures. J Am Dent Assoc 128 1 (1997) 37-45
-
(1997)
J Am Dent Assoc
, vol.128
, Issue.1
, pp. 37-45
-
-
Leinfelder, K.F.1
-
4
-
-
0026922738
-
Casting alloys: the materials and "the clinical effects"
-
Morris H.F., Manz M., Stoffer W., et al. Casting alloys: the materials and "the clinical effects". Adv Dent Res 6 (1992) 28-31
-
(1992)
Adv Dent Res
, vol.6
, pp. 28-31
-
-
Morris, H.F.1
Manz, M.2
Stoffer, W.3
-
6
-
-
0000429952
-
Vanadium steel bone plates and screws
-
Sherman W.O. Vanadium steel bone plates and screws. Surg Gynecol Obstet 14 6 (1912) 629-634
-
(1912)
Surg Gynecol Obstet
, vol.14
, Issue.6
, pp. 629-634
-
-
Sherman, W.O.1
-
7
-
-
34250688183
-
-
Strauss B. Steel alloy, 1,587,614. United States Patent Office; June 8, 1926.
-
-
-
-
9
-
-
0024710605
-
Mechanical properties and clinical applications of orthodontic wires
-
Kapila S., and Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod Dentofacial Orthop 96 2 (1989) 100-109
-
(1989)
Am J Orthod Dentofacial Orthop
, vol.96
, Issue.2
, pp. 100-109
-
-
Kapila, S.1
Sachdeva, R.2
-
10
-
-
2442585309
-
Properties of super stainless steels for orthodontic applications
-
Oh K.T., Kim Y.S., Park Y.S., et al. Properties of super stainless steels for orthodontic applications. J Biomed Mater Res B Appl Biomater 69 2 (2004) 183-194
-
(2004)
J Biomed Mater Res B Appl Biomater
, vol.69
, Issue.2
, pp. 183-194
-
-
Oh, K.T.1
Kim, Y.S.2
Park, Y.S.3
-
11
-
-
0026922624
-
Biodegradation of restorative metallic systems
-
Lucas L.C., and Lemons J.E. Biodegradation of restorative metallic systems. Adv Dent Res 6 (1992) 32-37
-
(1992)
Adv Dent Res
, vol.6
, pp. 32-37
-
-
Lucas, L.C.1
Lemons, J.E.2
-
12
-
-
34250685619
-
-
TruChrome MSDS data sSheet. Rocky Mountain Orthodontics. Rocky Mountain Orthodontics. Available at: http://www.rmortho.com/products/info/MSDS/TruChrome%20Stainless%20Steel.dot. Accessed September 5, 2006.
-
-
-
-
14
-
-
0037773144
-
Metals in orthopedic surgery
-
Wise D.L. (Ed), Marcel Dekker, New York
-
Shetty R.H., and Ottersberg W.H. Metals in orthopedic surgery. In: Wise D.L. (Ed). Encyclopedic handbook of biomaterials and bioengineering, vol. 1 (1995), Marcel Dekker, New York 509-540
-
(1995)
Encyclopedic handbook of biomaterials and bioengineering, vol. 1
, pp. 509-540
-
-
Shetty, R.H.1
Ottersberg, W.H.2
-
15
-
-
34250664190
-
-
Moffa JP. Physical and mechanical pProperties of gold and base metal alloys. Presented at the Alternative to Gold Alloys in Dentistry. Bethesda (MD), January 24-26, 1977.
-
-
-
-
17
-
-
0018457168
-
The influence of heat treatments on several types of base-metal removable partial denture alloys
-
Morris H.F., Asgar K., Rowe A.P., et al. The influence of heat treatments on several types of base-metal removable partial denture alloys. J Prosthet Dent 41 4 (1979) 388-395
-
(1979)
J Prosthet Dent
, vol.41
, Issue.4
, pp. 388-395
-
-
Morris, H.F.1
Asgar, K.2
Rowe, A.P.3
-
18
-
-
34250627481
-
-
Elgiloy MSDS data sheet. Rocky Mountain Orthodontics: Rocky Mountain Orthodontics. Available at: http://www.rmortho.com/products/info/MSDS/Elgiloy.dot. Accessed September 5, 2006.
-
-
-
-
19
-
-
34250623518
-
-
Disegi J. AO/ASIF Materials Technical Commission. Titanium-6% aluminum-7% niobium implant material; AO/ASIF Materials Technical Commission, Switzerland; 1993.
-
-
-
-
20
-
-
34250641389
-
-
Disegi J. AO/ASIF Materials Expert Group. Wrought titanium 15% molybdenum implant material; AO/ASIF Materials Technical Commission, Switzerland; 2003.
-
-
-
-
21
-
-
0018344605
-
An evaluation of beta titanium alloys for use in orthodontic appliances
-
Goldberg J., and Burstone C.J. An evaluation of beta titanium alloys for use in orthodontic appliances. J Dent Res 58 2 (1979) 593-599
-
(1979)
J Dent Res
, vol.58
, Issue.2
, pp. 593-599
-
-
Goldberg, J.1
Burstone, C.J.2
-
22
-
-
0021412467
-
Casting properties of Ni-Ti shape memory alloy
-
Takahashi J., Okazaki M., Kimura H., et al. Casting properties of Ni-Ti shape memory alloy. J Biomed Mater Res 18 4 (1984) 427-434
-
(1984)
J Biomed Mater Res
, vol.18
, Issue.4
, pp. 427-434
-
-
Takahashi, J.1
Okazaki, M.2
Kimura, H.3
-
24
-
-
0018831556
-
Beta titanium: a new orthodontic alloy
-
Burstone C.J., and Goldberg A.J. Beta titanium: a new orthodontic alloy. Am J Orthod 77 2 (1980) 121-132
-
(1980)
Am J Orthod
, vol.77
, Issue.2
, pp. 121-132
-
-
Burstone, C.J.1
Goldberg, A.J.2
-
25
-
-
0002631931
-
Mechanical properties of stainless steel orthodontic archwires
-
Kusy R., Dilley G., and Whitley J. Mechanical properties of stainless steel orthodontic archwires. Clin Mater 3 (1988) 41-59
-
(1988)
Clin Mater
, vol.3
, pp. 41-59
-
-
Kusy, R.1
Dilley, G.2
Whitley, J.3
-
26
-
-
0033072152
-
Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
-
Kim H., and Johnson J.W. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires. Angle Orthod 69 1 (1999) 39-44
-
(1999)
Angle Orthod
, vol.69
, Issue.1
, pp. 39-44
-
-
Kim, H.1
Johnson, J.W.2
-
27
-
-
0020724695
-
The chloride corrosion behaviour of four orthodontic wires
-
Sarkar N.K., Redmond W., Schwaninger B., et al. The chloride corrosion behaviour of four orthodontic wires. J Oral Rehabil 10 2 (1983) 121-128
-
(1983)
J Oral Rehabil
, vol.10
, Issue.2
, pp. 121-128
-
-
Sarkar, N.K.1
Redmond, W.2
Schwaninger, B.3
-
28
-
-
33644657458
-
Surface analysis and corrosion resistance of different stainless steel orthodontic brackets in artificial saliva
-
Lin M.C., Lin S.C., Lee T.H., et al. Surface analysis and corrosion resistance of different stainless steel orthodontic brackets in artificial saliva. Angle Orthod 76 2 (2006) 322-329
-
(2006)
Angle Orthod
, vol.76
, Issue.2
, pp. 322-329
-
-
Lin, M.C.1
Lin, S.C.2
Lee, T.H.3
-
29
-
-
0041804110
-
In vitro surface corrosion of stainless steel and NiTi orthodontic appliances
-
Shin J.S., Oh K.T., and Hwang C.J. In vitro surface corrosion of stainless steel and NiTi orthodontic appliances. Aust Orthod J 19 1 (2003) 13-18
-
(2003)
Aust Orthod J
, vol.19
, Issue.1
, pp. 13-18
-
-
Shin, J.S.1
Oh, K.T.2
Hwang, C.J.3
-
30
-
-
0029183960
-
In vitro release of nickel and chromium from different types of simulated orthodontic appliances
-
Kerosuo H., Moe G., and Kleven E. In vitro release of nickel and chromium from different types of simulated orthodontic appliances. Angle Orthod 65 2 (1995) 111-116
-
(1995)
Angle Orthod
, vol.65
, Issue.2
, pp. 111-116
-
-
Kerosuo, H.1
Moe, G.2
Kleven, E.3
-
31
-
-
0033174844
-
Ion release from orthodontic appliances
-
Staffolani N., Damiani F., Lilli C., et al. Ion release from orthodontic appliances. J Dent 27 6 (1999) 449-454
-
(1999)
J Dent
, vol.27
, Issue.6
, pp. 449-454
-
-
Staffolani, N.1
Damiani, F.2
Lilli, C.3
-
32
-
-
0036716115
-
The use of stainless steel crowns
-
Seale N.S. The use of stainless steel crowns. Pediatr Dent 24 5 (2002) 501-505
-
(2002)
Pediatr Dent
, vol.24
, Issue.5
, pp. 501-505
-
-
Seale, N.S.1
-
33
-
-
27744438990
-
General dental practitioners' views on the use of stainless steel crowns to restore primary molars
-
[discussion: 441]
-
Threlfall A.G., Pilkington L., Milsom K.M., et al. General dental practitioners' views on the use of stainless steel crowns to restore primary molars. Br Dent J 199 7 (2005) 453-455 [discussion: 441]
-
(2005)
Br Dent J
, vol.199
, Issue.7
, pp. 453-455
-
-
Threlfall, A.G.1
Pilkington, L.2
Milsom, K.M.3
-
34
-
-
0344334857
-
Fixation of bones by plates and screws
-
Peterson L. Fixation of bones by plates and screws. J Bone Joint Surg 29 (1947) 335-347
-
(1947)
J Bone Joint Surg
, vol.29
, pp. 335-347
-
-
Peterson, L.1
-
35
-
-
0014310313
-
Mechanical properties and stress relief of stainless steel orthodontic wire
-
Howe G.L., Greener E.H., and Crimmins D.S. Mechanical properties and stress relief of stainless steel orthodontic wire. Angle Orthod 38 3 (1968) 244-249
-
(1968)
Angle Orthod
, vol.38
, Issue.3
, pp. 244-249
-
-
Howe, G.L.1
Greener, E.H.2
Crimmins, D.S.3
-
36
-
-
0020012019
-
Corrosion of orthodontic bracket bases
-
Maijer R., and Smith D.C. Corrosion of orthodontic bracket bases. Am J Orthod 81 1 (1982) 43-48
-
(1982)
Am J Orthod
, vol.81
, Issue.1
, pp. 43-48
-
-
Maijer, R.1
Smith, D.C.2
-
37
-
-
34250649980
-
-
ASTM Standard Specification for wrought 18-chromium 14-nickel 2.5-molybdenum stainless steel bar and wire for surgical implants (UNS S31673) F138-00. Annual book of ASTM standards. Section 13 - Medical devices and services, volume 13.01. West Conshohocken (PA): American Society for Testing and Materials; 2000.
-
-
-
-
38
-
-
0038722961
-
Comparison of the corrosion fatigue of BioDur 108 to 316LS.S. and 22Cr-13Ni-5Mn stainless steels
-
Winters G.L., and Nutt M.J. (Eds), ASTM International, West Conshohocken (PA)
-
Zardiackas L.D., Roach M.D., Williamson R.S., et al. Comparison of the corrosion fatigue of BioDur 108 to 316LS.S. and 22Cr-13Ni-5Mn stainless steels. In: Winters G.L., and Nutt M.J. (Eds). Stainless steels for medical and surgical applications. ASTM 1438 (2003), ASTM International, West Conshohocken (PA) 194-210
-
(2003)
Stainless steels for medical and surgical applications. ASTM 1438
, pp. 194-210
-
-
Zardiackas, L.D.1
Roach, M.D.2
Williamson, R.S.3
-
39
-
-
34250646878
-
-
Fraker AC. Corrosion of metallic implants and prosthetic devices. Metals handbook. 9th edition, vol. 13. Metals Park (OH): ASM International; 1987. p. 1324-35.
-
-
-
-
40
-
-
0032779294
-
The influence of surface condition on the localized corrosion of 316L stainless steel orthopaedic implants
-
Beddoes J., and Bucci K. The influence of surface condition on the localized corrosion of 316L stainless steel orthopaedic implants. J Mater Sci Mater Med 10 (1999) 389-394
-
(1999)
J Mater Sci Mater Med
, vol.10
, pp. 389-394
-
-
Beddoes, J.1
Bucci, K.2
-
41
-
-
0038174777
-
Comparison of the notch sensitivity and stress corrosion cracking of a low-nickel stainless steel to 316LS and 22Cr-13Ni-5Mn stainless steels
-
Winters G.L., and Nutt M.J. (Eds), ASTM International, West Conshohocken (PA)
-
Zardiackas L.D., Roach M.D., Williamson R.S., et al. Comparison of the notch sensitivity and stress corrosion cracking of a low-nickel stainless steel to 316LS and 22Cr-13Ni-5Mn stainless steels. In: Winters G.L., and Nutt M.J. (Eds). Stainless steels for medical and surgical applications. ASTM 1438 (2003), ASTM International, West Conshohocken (PA) 154-167
-
(2003)
Stainless steels for medical and surgical applications. ASTM 1438
, pp. 154-167
-
-
Zardiackas, L.D.1
Roach, M.D.2
Williamson, R.S.3
-
42
-
-
13844299041
-
-
Roach MD, McGuire J, Williamson RS, et al. Characterization of the torsional properties of stainless steel and titanium alloys used as implants. Proceedings of the 7th World Biomaterials Congress. Sydney (Australia); May 17-21, 2004.
-
-
-
-
43
-
-
0038513576
-
Comparison of anodic polarization and galvanic corrosion of a low-nickel stainless steel to 316LS and 22Cr-13Ni-5Mn stainless steels
-
Winters G.L., and Nutt M.J. (Eds), ASTM International, West Conshohocken (PA)
-
Zardiackas L.D., Roach M.D., Williamson R.S., et al. Comparison of anodic polarization and galvanic corrosion of a low-nickel stainless steel to 316LS and 22Cr-13Ni-5Mn stainless steels. In: Winters G.L., and Nutt M.J. (Eds). Stainless steels for medical and surgical applications. ASTM 1438 (2003), ASTM International, West Conshohocken (PA)
-
(2003)
Stainless steels for medical and surgical applications. ASTM 1438
-
-
Zardiackas, L.D.1
Roach, M.D.2
Williamson, R.S.3
-
44
-
-
33746954635
-
Comparison of the corrosion fatigue characteristics of 23Mn-21Cr-1Mo low nickel, 22Cr-13Ni-5Mn, and 18Cr-14Ni-2.5Mo stainless steels
-
Roach M.D., Williamson R.S., and Zardiackas L.D. Comparison of the corrosion fatigue characteristics of 23Mn-21Cr-1Mo low nickel, 22Cr-13Ni-5Mn, and 18Cr-14Ni-2.5Mo stainless steels. Journal of ASTM International 3 5 (2006) 1-11
-
(2006)
Journal of ASTM International
, vol.3
, Issue.5
, pp. 1-11
-
-
Roach, M.D.1
Williamson, R.S.2
Zardiackas, L.D.3
-
46
-
-
0024444245
-
Nickel, chromium, cobalt dental alloys and allergic reactions: an overview
-
Hildebrand H.F., Veron C., and Martin P. Nickel, chromium, cobalt dental alloys and allergic reactions: an overview. Biomaterials 10 8 (1989) 545-548
-
(1989)
Biomaterials
, vol.10
, Issue.8
, pp. 545-548
-
-
Hildebrand, H.F.1
Veron, C.2
Martin, P.3
-
47
-
-
34250615769
-
-
Carpenter technology corporation BioDur 108 alloy data sheet. Available at: http://www.cartech.com/common/frames.html?http://cartech.ides.com/ListSearch.aspx?ST=DESC&i=101&leftn=sao_products&lefto=nav_tlo&lefti=nav_tlo3. Accessed September 5, 2006.
-
-
-
-
48
-
-
0034450007
-
Stainless steel in bone surgery
-
Disegi J.A., and Eschbach L. Stainless steel in bone surgery. Injury 31 Suppl 4 (2000) 2-6
-
(2000)
Injury
, vol.31
, Issue.SUPPL. 4
, pp. 2-6
-
-
Disegi, J.A.1
Eschbach, L.2
-
50
-
-
34250621235
-
-
Carpenter specialty alloys Corporation. BioDur 108 alloy data sheet. Reading (PA): CRS Holdings, Inc.; 2000.
-
-
-
-
51
-
-
34250619455
-
-
Ticonium. Available at: http://www.cmpindustry.com/company.asp. Accessed September 4, 2006.
-
-
-
-
52
-
-
34250613340
-
-
Touceda EG. Denture, 2,089,587. United States Patent Office; August 10, 1937.
-
-
-
-
55
-
-
0040462566
-
Composition and properties of noble and precious metal alloys
-
Smith D.C., and Williams D.F. (Eds), CRC Press, Boca Raton (FL)
-
Tucillo J., and Cascone P. Composition and properties of noble and precious metal alloys. In: Smith D.C., and Williams D.F. (Eds). CRC series in biocompatibility: biocompatibility of dental materials (1982), CRC Press, Boca Raton (FL) 19-36
-
(1982)
CRC series in biocompatibility: biocompatibility of dental materials
, pp. 19-36
-
-
Tucillo, J.1
Cascone, P.2
-
56
-
-
0021307512
-
Auger chemical analysis of oxides on Ni-Cr alloys
-
Baran G. Auger chemical analysis of oxides on Ni-Cr alloys. J Dent Res 63 1 (1984) 76-80
-
(1984)
J Dent Res
, vol.63
, Issue.1
, pp. 76-80
-
-
Baran, G.1
-
57
-
-
0020853968
-
The metallurgy of Ni-Cr alloys for fixed prosthodontics
-
Baran G.R. The metallurgy of Ni-Cr alloys for fixed prosthodontics. J Prosthet Dent 50 5 (1983) 639-650
-
(1983)
J Prosthet Dent
, vol.50
, Issue.5
, pp. 639-650
-
-
Baran, G.R.1
-
58
-
-
0027639179
-
Surface analysis of nickel-chromium dental alloys
-
Bumgardner J.D., and Lucas L.C. Surface analysis of nickel-chromium dental alloys. Dent Mater 9 4 (1993) 252-259
-
(1993)
Dent Mater
, vol.9
, Issue.4
, pp. 252-259
-
-
Bumgardner, J.D.1
Lucas, L.C.2
-
59
-
-
0022114745
-
Beryllium localization in base metal dental casting alloys
-
Covington J.S., McBride M.A., Slagle W.F., et al. Beryllium localization in base metal dental casting alloys. J Biomed Mater Res 19 7 (1985) 747-750
-
(1985)
J Biomed Mater Res
, vol.19
, Issue.7
, pp. 747-750
-
-
Covington, J.S.1
McBride, M.A.2
Slagle, W.F.3
-
60
-
-
0022098004
-
Quantization of nickel and beryllium leakage from base metal casting alloys
-
Covington J.S., McBride M.A., Slagle W.F., et al. Quantization of nickel and beryllium leakage from base metal casting alloys. J Prosthet Dent 54 1 (1985) 127-136
-
(1985)
J Prosthet Dent
, vol.54
, Issue.1
, pp. 127-136
-
-
Covington, J.S.1
McBride, M.A.2
Slagle, W.F.3
-
61
-
-
0034566812
-
Use of x-ray photoelectron spectroscopy and cyclic polarization to evaluate the corrosion behavior of six nickel-chromium alloys before and after porcelain-fused-to-metal firing
-
Roach M.D., Wolan J.T., Parsell D.E., et al. Use of x-ray photoelectron spectroscopy and cyclic polarization to evaluate the corrosion behavior of six nickel-chromium alloys before and after porcelain-fused-to-metal firing. J Prosthet Dent 84 6 (2000) 623-634
-
(2000)
J Prosthet Dent
, vol.84
, Issue.6
, pp. 623-634
-
-
Roach, M.D.1
Wolan, J.T.2
Parsell, D.E.3
-
62
-
-
0030119324
-
Castability, opaque masking, and porcelain bonding of 17 porcelain-fused-to-metal alloys
-
O'Connor R.P., Mackert Jr. J.R., Myers M.L., et al. Castability, opaque masking, and porcelain bonding of 17 porcelain-fused-to-metal alloys. J Prosthet Dent 75 4 (1996) 367-374
-
(1996)
J Prosthet Dent
, vol.75
, Issue.4
, pp. 367-374
-
-
O'Connor, R.P.1
Mackert Jr., J.R.2
Myers, M.L.3
-
63
-
-
0000037320
-
In vitro corrosion analyses of nickel-base alloys
-
Lee J., Lucas L., O'Neal J., et al. In vitro corrosion analyses of nickel-base alloys. J Dent Res 63 DMG 1285 (1985) 1-21
-
(1985)
J Dent Res
, vol.63
, Issue.DMG 1285
, pp. 1-21
-
-
Lee, J.1
Lucas, L.2
O'Neal, J.3
-
64
-
-
0017685489
-
Corrosion resistance of nickel-chromium dental casting alloys
-
Meyer J. Corrosion resistance of nickel-chromium dental casting alloys. Corrosion Science 17 (1977) 971-982
-
(1977)
Corrosion Science
, vol.17
, pp. 971-982
-
-
Meyer, J.1
-
65
-
-
0027596344
-
Studies on the influence of Be content on the corrosion behavior and mechanical properties of Ni-25Cr-10Mo alloys
-
Geis-Gerstorfer J., and Passler K. Studies on the influence of Be content on the corrosion behavior and mechanical properties of Ni-25Cr-10Mo alloys. Dent Mater 9 3 (1993) 177-181
-
(1993)
Dent Mater
, vol.9
, Issue.3
, pp. 177-181
-
-
Geis-Gerstorfer, J.1
Passler, K.2
-
66
-
-
0026115971
-
Ion release from Ni-Cr-Mo and Co-Cr-Mo casting alloys
-
Geis-Gerstorfer J., Sauer K.H., and Passler K. Ion release from Ni-Cr-Mo and Co-Cr-Mo casting alloys. Int J Prosthodont 4 2 (1991) 152-158
-
(1991)
Int J Prosthodont
, vol.4
, Issue.2
, pp. 152-158
-
-
Geis-Gerstorfer, J.1
Sauer, K.H.2
Passler, K.3
-
67
-
-
0029355343
-
Cellular response to metallic ions released from nickel-chromium dental alloys
-
Bumgardner J.D., and Lucas L.C. Cellular response to metallic ions released from nickel-chromium dental alloys. J Dent Res 74 8 (1995) 1521-1527
-
(1995)
J Dent Res
, vol.74
, Issue.8
, pp. 1521-1527
-
-
Bumgardner, J.D.1
Lucas, L.C.2
-
68
-
-
0032252669
-
Effect of pH on element release from dental casting alloys
-
Wataha J.C., Lockwood P.E., Khajotia S.S., et al. Effect of pH on element release from dental casting alloys. J Prosthet Dent 80 6 (1998) 691-698
-
(1998)
J Prosthet Dent
, vol.80
, Issue.6
, pp. 691-698
-
-
Wataha, J.C.1
Lockwood, P.E.2
Khajotia, S.S.3
-
69
-
-
0026929858
-
Leaching of nickel, chromium, and beryllium ions from base metal alloy in an artificial oral environment
-
Tai Y., De Long R., Goodkind R.J., et al. Leaching of nickel, chromium, and beryllium ions from base metal alloy in an artificial oral environment. J Prosthet Dent 68 4 (1992) 692-697
-
(1992)
J Prosthet Dent
, vol.68
, Issue.4
, pp. 692-697
-
-
Tai, Y.1
De Long, R.2
Goodkind, R.J.3
-
70
-
-
0021695168
-
Changes in mechanical properties and microstructure following heat treatment of a nickel-chromium base alloy
-
Winkler S., Morris H.F., and Monteiro J.M. Changes in mechanical properties and microstructure following heat treatment of a nickel-chromium base alloy. J Prosthet Dent 52 6 (1984) 821-827
-
(1984)
J Prosthet Dent
, vol.52
, Issue.6
, pp. 821-827
-
-
Winkler, S.1
Morris, H.F.2
Monteiro, J.M.3
-
71
-
-
0022796123
-
Influence of heat treatment on the surface texture of an etched cast nickel-chromium base alloy: an evaluation by profilometric records
-
Marinello C.P., Luthy H., and Scharer P. Influence of heat treatment on the surface texture of an etched cast nickel-chromium base alloy: an evaluation by profilometric records. J Prosthet Dent 56 4 (1986) 431-435
-
(1986)
J Prosthet Dent
, vol.56
, Issue.4
, pp. 431-435
-
-
Marinello, C.P.1
Luthy, H.2
Scharer, P.3
-
72
-
-
0024617233
-
Veterans Administration Cooperative Studies Project No. 147/242. Part VII: the mechanical properties of metal ceramic alloys as cast and after simulated porcelain firing
-
Morris H.F. Veterans Administration Cooperative Studies Project No. 147/242. Part VII: the mechanical properties of metal ceramic alloys as cast and after simulated porcelain firing. J Prosthet Dent 61 2 (1989) 160-169
-
(1989)
J Prosthet Dent
, vol.61
, Issue.2
, pp. 160-169
-
-
Morris, H.F.1
-
73
-
-
0020456135
-
Electrochemical study of corrosion in Ni-Cr dental alloys
-
de De Micheli S.M., and Riesgo O. Electrochemical study of corrosion in Ni-Cr dental alloys. Biomaterials 3 4 (1982) 209-212
-
(1982)
Biomaterials
, vol.3
, Issue.4
, pp. 209-212
-
-
de De Micheli, S.M.1
Riesgo, O.2
-
75
-
-
0021503786
-
Biocompatibility of nickel based dental alloys
-
Moffa J.P. Biocompatibility of nickel based dental alloys. CDA J 12 10 (1984) 45-51
-
(1984)
CDA J
, vol.12
, Issue.10
, pp. 45-51
-
-
Moffa, J.P.1
-
76
-
-
0022792398
-
Dental implications of nickel hypersensitivity
-
Jones T.K., Hansen C.A., Singer M.T., et al. Dental implications of nickel hypersensitivity. J Prosthet Dent 56 4 (1986) 507-509
-
(1986)
J Prosthet Dent
, vol.56
, Issue.4
, pp. 507-509
-
-
Jones, T.K.1
Hansen, C.A.2
Singer, M.T.3
-
77
-
-
34250666512
-
-
Haynes E. Metal alloy, 873,745. United States Patent Office; December 17, 1907.
-
-
-
-
78
-
-
0040421841
-
A survey of dental alloys
-
Lane J.R. A survey of dental alloys. J Am Dent Assoc 39 (1949) 414-437
-
(1949)
J Am Dent Assoc
, vol.39
, pp. 414-437
-
-
Lane, J.R.1
-
79
-
-
34250649572
-
-
Prange CH. Cast metallic denture, 1,958,446: United States Patent Office; May 15, 1934.
-
-
-
-
81
-
-
5244258774
-
Electrolysis controlling factor in the use of metals in treating fractures
-
Venable C.S., and Stuck W.G. Electrolysis controlling factor in the use of metals in treating fractures. J Am Med Assoc 111 13 (1938) 1349-1352
-
(1938)
J Am Med Assoc
, vol.111
, Issue.13
, pp. 1349-1352
-
-
Venable, C.S.1
Stuck, W.G.2
-
82
-
-
0001220717
-
The effects on bone of the presence of metals based upon electrolysis
-
Venable C.S., Stuck W.G., and Beach A. The effects on bone of the presence of metals based upon electrolysis. Annals of Surgery 105 6 (1937) 917-938
-
(1937)
Annals of Surgery
, vol.105
, Issue.6
, pp. 917-938
-
-
Venable, C.S.1
Stuck, W.G.2
Beach, A.3
-
83
-
-
0021222925
-
Ductility and structure of some cobalt-base dental casting alloys
-
Hero H., Syverud M., Gjonnes J., et al. Ductility and structure of some cobalt-base dental casting alloys. Biomaterials 5 4 (1984) 201-208
-
(1984)
Biomaterials
, vol.5
, Issue.4
, pp. 201-208
-
-
Hero, H.1
Syverud, M.2
Gjonnes, J.3
-
84
-
-
0002901015
-
Effect of microstructure on physical properties of cobalt alloys
-
Asgar K., and Peyton F.A. Effect of microstructure on physical properties of cobalt alloys. J Dent Res 40 1 (1961) 63-72
-
(1961)
J Dent Res
, vol.40
, Issue.1
, pp. 63-72
-
-
Asgar, K.1
Peyton, F.A.2
-
86
-
-
0026895146
-
Corrosion testing by potentiodynamic polarization in various electrolytes
-
Holland R.I. Corrosion testing by potentiodynamic polarization in various electrolytes. Dent Mater 8 4 (1992) 241-245
-
(1992)
Dent Mater
, vol.8
, Issue.4
, pp. 241-245
-
-
Holland, R.I.1
-
87
-
-
0023394453
-
Corrosion rate studies: measurements of corrosion rates of some non-precious dental alloys in artificial saliva
-
Wiegman-Ho L., and Ketelaar J.A. Corrosion rate studies: measurements of corrosion rates of some non-precious dental alloys in artificial saliva. J Dent 15 4 (1987) 166-170
-
(1987)
J Dent
, vol.15
, Issue.4
, pp. 166-170
-
-
Wiegman-Ho, L.1
Ketelaar, J.A.2
-
88
-
-
0029314586
-
Corrosion evaluation of recasting non-precious dental alloys
-
Khamis E., and Seddik M. Corrosion evaluation of recasting non-precious dental alloys. Int Dent J 45 3 (1995) 209-217
-
(1995)
Int Dent J
, vol.45
, Issue.3
, pp. 209-217
-
-
Khamis, E.1
Seddik, M.2
-
89
-
-
14644444536
-
Corrosion resistance of cobalt-chromium and palladium-silver alloys used in fixed prosthetic restorations
-
Viennot S., Dalard F., Lissac M., et al. Corrosion resistance of cobalt-chromium and palladium-silver alloys used in fixed prosthetic restorations. Eur J Oral Sci 113 1 (2005) 90-95
-
(2005)
Eur J Oral Sci
, vol.113
, Issue.1
, pp. 90-95
-
-
Viennot, S.1
Dalard, F.2
Lissac, M.3
-
90
-
-
2942613210
-
Comparison of metal release from various metallic biomaterials in vitro
-
Okazaki Y., and Gotoh E. Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 26 1 (2005) 11-21
-
(2005)
Biomaterials
, vol.26
, Issue.1
, pp. 11-21
-
-
Okazaki, Y.1
Gotoh, E.2
-
92
-
-
34250613341
-
-
Elgiloy. Available at: http://www.elgiloy.com/history.html. Accessed August 24, 2006.
-
-
-
-
93
-
-
0017124812
-
Heat treatment of cobalt-chromium alloy wire
-
Fillmore G.M., and Tomlinson J.L. Heat treatment of cobalt-chromium alloy wire. Angle Orthod 46 2 (1976) 187-195
-
(1976)
Angle Orthod
, vol.46
, Issue.2
, pp. 187-195
-
-
Fillmore, G.M.1
Tomlinson, J.L.2
-
94
-
-
0018463411
-
Heat treatment of cobalt-chromium alloys of various tempers
-
Fillmore G.M., and Tomlinson J.L. Heat treatment of cobalt-chromium alloys of various tempers. Angle Orthod 49 2 (1979) 126-130
-
(1979)
Angle Orthod
, vol.49
, Issue.2
, pp. 126-130
-
-
Fillmore, G.M.1
Tomlinson, J.L.2
-
95
-
-
34250656827
-
-
Rocky Mountain Orthodontics. Product Catalog. Available at: http://www.rockymountainorthodontics.com/assets/content.html. Accessed September 4, 2006.
-
-
-
-
97
-
-
0042883748
-
Relative stiffness of beta titanium archwires
-
Johnson E. Relative stiffness of beta titanium archwires. Angle Orthod 73 3 (2003) 259-269
-
(2003)
Angle Orthod
, vol.73
, Issue.3
, pp. 259-269
-
-
Johnson, E.1
-
98
-
-
0022685056
-
Comparison of bending and tension tests for orthodontic wires
-
Asgharnia M.K., and Brantley W.A. Comparison of bending and tension tests for orthodontic wires. Am J Orthod 89 3 (1986) 228-236
-
(1986)
Am J Orthod
, vol.89
, Issue.3
, pp. 228-236
-
-
Asgharnia, M.K.1
Brantley, W.A.2
-
99
-
-
0016483665
-
Cast vs. wrought cobalt-chromium surgical implant alloys
-
Devine T.M., and Wulff J. Cast vs. wrought cobalt-chromium surgical implant alloys. J Biomed Mater Res 9 (1975) 151-167
-
(1975)
J Biomed Mater Res
, vol.9
, pp. 151-167
-
-
Devine, T.M.1
Wulff, J.2
-
100
-
-
0019068816
-
Anodic polarization behavior of Ti-Ni and Ti-6A1-4V in simulated physiological solutions
-
Speck K.M., and Fraker A.C. Anodic polarization behavior of Ti-Ni and Ti-6A1-4V in simulated physiological solutions. J Dent Res 59 10 (1980) 1590-1595
-
(1980)
J Dent Res
, vol.59
, Issue.10
, pp. 1590-1595
-
-
Speck, K.M.1
Fraker, A.C.2
-
101
-
-
34250634684
-
-
Disegi J. AO/ASIF Unalloyed tTitanium implant material; 1991.
-
-
-
-
103
-
-
34250641776
-
-
Kroll W. Method for manufacturing tTitanium and alloys tThereof, 2,205,854. Uniteds States Patent Office; June 25, 1940.
-
-
-
-
104
-
-
20544476277
-
Metallurgy and technological properties of titanium and titanium alloys
-
Brunette D.M., Tengvall P., and Textor M. (Eds), Springer, Berlin
-
Freese H., Volas M., and Wood J. Metallurgy and technological properties of titanium and titanium alloys. In: Brunette D.M., Tengvall P., and Textor M. (Eds). Titanium in medicine: material science, surface science, engineering, biological responses, and medical applications (2001), Springer, Berlin 25-53
-
(2001)
Titanium in medicine: material science, surface science, engineering, biological responses, and medical applications
, pp. 25-53
-
-
Freese, H.1
Volas, M.2
Wood, J.3
-
105
-
-
0001289258
-
Reaction of bone to multiple metallic implants
-
Bothe R., Beaton L., and Davenport H. Reaction of bone to multiple metallic implants. J Surg Gynecol Obstet 71 5 (1940) 598-602
-
(1940)
J Surg Gynecol Obstet
, vol.71
, Issue.5
, pp. 598-602
-
-
Bothe, R.1
Beaton, L.2
Davenport, H.3
-
106
-
-
2542542518
-
Titanium, a metal for surgery
-
Leventhal G.S. Titanium, a metal for surgery. J Bone Joint Surg 33-A 2 (1951) 473-474
-
(1951)
J Bone Joint Surg
, vol.33 -A
, Issue.2
, pp. 473-474
-
-
Leventhal, G.S.1
-
107
-
-
0014636440
-
Intra-osseous anchorage of dental prostheses. I. Experimental studies
-
Bra{hook above}nemark P.I., Adell R., Breine U., et al. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 3 2 (1969) 81-100
-
(1969)
Scand J Plast Reconstr Surg
, vol.3
, Issue.2
, pp. 81-100
-
-
Branemark, P.I.1
Adell, R.2
Breine, U.3
-
108
-
-
0027616999
-
Titanium and titanium alloys as dental materials
-
Lautenschlager E.P., and Monaghan P. Titanium and titanium alloys as dental materials. Int Dent J 43 3 (1993) 245-253
-
(1993)
Int Dent J
, vol.43
, Issue.3
, pp. 245-253
-
-
Lautenschlager, E.P.1
Monaghan, P.2
-
109
-
-
0030155746
-
Titanium for prosthodontic applications: a review of the literature
-
Wang R.R., and Fenton A. Titanium for prosthodontic applications: a review of the literature. Quintessence Int 27 6 (1996) 401-408
-
(1996)
Quintessence Int
, vol.27
, Issue.6
, pp. 401-408
-
-
Wang, R.R.1
Fenton, A.2
-
110
-
-
0038281113
-
Titanium applications in dentistry
-
Titanium applications in dentistry. J Am Dent Assoc 134 3 (2003) 347-349
-
(2003)
J Am Dent Assoc
, vol.134
, Issue.3
, pp. 347-349
-
-
-
111
-
-
0027142077
-
Mold filling and porosity in castings of titanium
-
Hero H., Syverud M., and Waarli M. Mold filling and porosity in castings of titanium. Dent Mater 9 1 (1993) 15-18
-
(1993)
Dent Mater
, vol.9
, Issue.1
, pp. 15-18
-
-
Hero, H.1
Syverud, M.2
Waarli, M.3
-
112
-
-
0033070380
-
Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures
-
Walter M., Reppel P.D., Boning K., et al. Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures. J Oral Rehabil 26 2 (1999) 91-96
-
(1999)
J Oral Rehabil
, vol.26
, Issue.2
, pp. 91-96
-
-
Walter, M.1
Reppel, P.D.2
Boning, K.3
-
113
-
-
0034328117
-
Bond strength of three porcelains to two forms of titanium using two firing atmospheres
-
Atsu S., and Berksun S. Bond strength of three porcelains to two forms of titanium using two firing atmospheres. J Prosthet Dent 84 5 (2000) 567-574
-
(2000)
J Prosthet Dent
, vol.84
, Issue.5
, pp. 567-574
-
-
Atsu, S.1
Berksun, S.2
-
114
-
-
0024345249
-
Studies of Ti alloys for dental castings
-
Taira M., Moser J.B., and Greener E.H. Studies of Ti alloys for dental castings. Dent Mater 5 1 (1989) 45-50
-
(1989)
Dent Mater
, vol.5
, Issue.1
, pp. 45-50
-
-
Taira, M.1
Moser, J.B.2
Greener, E.H.3
-
115
-
-
0033289498
-
In vitro corrosion behaviour and metallic ion release of different prosthodontic alloys
-
Gil F.J., Sanchez L.A., Espias A., et al. In vitro corrosion behaviour and metallic ion release of different prosthodontic alloys. Int Dent J 49 6 (1999) 361-367
-
(1999)
Int Dent J
, vol.49
, Issue.6
, pp. 361-367
-
-
Gil, F.J.1
Sanchez, L.A.2
Espias, A.3
-
116
-
-
0026124943
-
The effect of oral topical fluorides on the surface of commercially pure titanium
-
Siirila H.S., and Kononen M. The effect of oral topical fluorides on the surface of commercially pure titanium. Int J Oral Maxillofac Implants 6 1 (1991) 50-54
-
(1991)
Int J Oral Maxillofac Implants
, vol.6
, Issue.1
, pp. 50-54
-
-
Siirila, H.S.1
Kononen, M.2
-
117
-
-
34250680016
-
Intra-osseous implants utilized as fixed bridge abutments
-
Linkow L. Intra-osseous implants utilized as fixed bridge abutments. Journal of Oral Implants and Transplants 10 (1964) 17-23
-
(1964)
Journal of Oral Implants and Transplants
, vol.10
, pp. 17-23
-
-
Linkow, L.1
-
118
-
-
0029396992
-
A thousand years of dental implants: a definitive history-part 2
-
1132, 1134, 1136
-
Ring M.E. A thousand years of dental implants: a definitive history-part 2. Compend Contin Educ Dent 16 11 (1995) 1132, 1134, 1136
-
(1995)
Compend Contin Educ Dent
, vol.16
, Issue.11
-
-
Ring, M.E.1
-
119
-
-
0033087665
-
Dental implant materials: commercially pure titanium and titanium alloys
-
McCracken M. Dental implant materials: commercially pure titanium and titanium alloys. J Prosthodont 8 1 (1999) 40-43
-
(1999)
J Prosthodont
, vol.8
, Issue.1
, pp. 40-43
-
-
McCracken, M.1
-
120
-
-
33744793215
-
Comparison of stress corrosion cracking characteristics of CP Ti, Ti-6Al-7Nb, Ti-6Al-4V, and Ti-15Mo
-
Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds), ASTM International, West Conshohocken (PA)
-
Williamson R.S., Roach M.D., and Zardiackas L.D. Comparison of stress corrosion cracking characteristics of CP Ti, Ti-6Al-7Nb, Ti-6Al-4V, and Ti-15Mo. In: Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds). Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471) (2006), ASTM International, West Conshohocken (PA) 166-182
-
(2006)
Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471)
, pp. 166-182
-
-
Williamson, R.S.1
Roach, M.D.2
Zardiackas, L.D.3
-
121
-
-
33744826806
-
Comparison of stress corrosion cracking and corrosion fatigue (anodized and non-anodized grade 4 CP Ti)
-
Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds), ASTM International, West Conshohocken (PA)
-
Zardiackas L.D., Roach M.D., and Williamson R.S. Comparison of stress corrosion cracking and corrosion fatigue (anodized and non-anodized grade 4 CP Ti). In: Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds). Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471) (2006), ASTM International, West Conshohocken (PA) 202-214
-
(2006)
Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471)
, pp. 202-214
-
-
Zardiackas, L.D.1
Roach, M.D.2
Williamson, R.S.3
-
122
-
-
33744786785
-
Comparison of corrosion fatigue characteristics of CP Ti-grade 4, Ti-6Al-4V ELI, Ti-6Al-7Nb, and Ti-15Mo
-
Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds), ASTM International, West Conshohocken (PA)
-
Roach M.D., Williamson R.S., and Zardiackas L.D. Comparison of corrosion fatigue characteristics of CP Ti-grade 4, Ti-6Al-4V ELI, Ti-6Al-7Nb, and Ti-15Mo. In: Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds). Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471) (2006), ASTM International, West Conshohocken (PA) 183-201
-
(2006)
Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471)
, pp. 183-201
-
-
Roach, M.D.1
Williamson, R.S.2
Zardiackas, L.D.3
-
123
-
-
0024446242
-
Clinical results with titanium crowns fabricated with machine duplication and spark erosion
-
Andersson M., Bergman B., Bessing C., et al. Clinical results with titanium crowns fabricated with machine duplication and spark erosion. Acta Odontol Scand 47 5 (1989) 279-286
-
(1989)
Acta Odontol Scand
, vol.47
, Issue.5
, pp. 279-286
-
-
Andersson, M.1
Bergman, B.2
Bessing, C.3
-
124
-
-
0026860865
-
Non-cast titanium restorations in fixed prosthodontics
-
Boening K.W., Walter M.H., and Reppel P.D. Non-cast titanium restorations in fixed prosthodontics. J Oral Rehabil 19 3 (1992) 281-287
-
(1992)
J Oral Rehabil
, vol.19
, Issue.3
, pp. 281-287
-
-
Boening, K.W.1
Walter, M.H.2
Reppel, P.D.3
-
125
-
-
0028506796
-
Marginal fit of machine-milled titanium and cast titanium single crowns
-
Leong D., Chai J., Lautenschlager E., et al. Marginal fit of machine-milled titanium and cast titanium single crowns. Int J Prosthodont 7 5 (1994) 440-447
-
(1994)
Int J Prosthodont
, vol.7
, Issue.5
, pp. 440-447
-
-
Leong, D.1
Chai, J.2
Lautenschlager, E.3
-
126
-
-
1842869161
-
Machinability of cast commercial titanium alloys
-
Watanabe I., Kiyosue S., Ohkubo C., et al. Machinability of cast commercial titanium alloys. J Biomed Mater Res 63 6 (2002) 760-764
-
(2002)
J Biomed Mater Res
, vol.63
, Issue.6
, pp. 760-764
-
-
Watanabe, I.1
Kiyosue, S.2
Ohkubo, C.3
-
127
-
-
0034231421
-
An overview of nickel-titanium alloys used in dentistry
-
Thompson S.A. An overview of nickel-titanium alloys used in dentistry. Int Endod J 33 4 (2000) 297-310
-
(2000)
Int Endod J
, vol.33
, Issue.4
, pp. 297-310
-
-
Thompson, S.A.1
|