메뉴 건너뛰기




Volumn 51, Issue 3, 2007, Pages 603-627

Base Metal Alloys Used for Dental Restorations and Implants

Author keywords

[No Author keywords available]

Indexed keywords

CHROMIUM DERIVATIVE; DENTAL ALLOY; NICKEL; STAINLESS STEEL; TITANIUM; TITANIUM NICKELIDE; UNCLASSIFIED DRUG;

EID: 34250633633     PISSN: 00118532     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cden.2007.04.001     Document Type: Review
Times cited : (96)

References (127)
  • 1
    • 0029385307 scopus 로고
    • A thousand years of dental implants: a definitive history part 1
    • 1060, 1062, 1064
    • Ring M.E. A thousand years of dental implants: a definitive history part 1. Compend Contin Educ Dent 16 10 (1995) 1060, 1062, 1064
    • (1995) Compend Contin Educ Dent , vol.16 , Issue.10
    • Ring, M.E.1
  • 2
    • 0036986529 scopus 로고    scopus 로고
    • Orthodontic biomaterials: from the past to the present
    • Kusy R.P. Orthodontic biomaterials: from the past to the present. Angle Orthod 72 6 (2002) 501-512
    • (2002) Angle Orthod , vol.72 , Issue.6 , pp. 501-512
    • Kusy, R.P.1
  • 3
    • 0030641633 scopus 로고    scopus 로고
    • An evaluation of casting alloys used for restorative procedures
    • Leinfelder K.F. An evaluation of casting alloys used for restorative procedures. J Am Dent Assoc 128 1 (1997) 37-45
    • (1997) J Am Dent Assoc , vol.128 , Issue.1 , pp. 37-45
    • Leinfelder, K.F.1
  • 4
    • 0026922738 scopus 로고
    • Casting alloys: the materials and "the clinical effects"
    • Morris H.F., Manz M., Stoffer W., et al. Casting alloys: the materials and "the clinical effects". Adv Dent Res 6 (1992) 28-31
    • (1992) Adv Dent Res , vol.6 , pp. 28-31
    • Morris, H.F.1    Manz, M.2    Stoffer, W.3
  • 6
    • 0000429952 scopus 로고
    • Vanadium steel bone plates and screws
    • Sherman W.O. Vanadium steel bone plates and screws. Surg Gynecol Obstet 14 6 (1912) 629-634
    • (1912) Surg Gynecol Obstet , vol.14 , Issue.6 , pp. 629-634
    • Sherman, W.O.1
  • 7
    • 34250688183 scopus 로고    scopus 로고
    • Strauss B. Steel alloy, 1,587,614. United States Patent Office; June 8, 1926.
  • 9
    • 0024710605 scopus 로고
    • Mechanical properties and clinical applications of orthodontic wires
    • Kapila S., and Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod Dentofacial Orthop 96 2 (1989) 100-109
    • (1989) Am J Orthod Dentofacial Orthop , vol.96 , Issue.2 , pp. 100-109
    • Kapila, S.1    Sachdeva, R.2
  • 10
    • 2442585309 scopus 로고    scopus 로고
    • Properties of super stainless steels for orthodontic applications
    • Oh K.T., Kim Y.S., Park Y.S., et al. Properties of super stainless steels for orthodontic applications. J Biomed Mater Res B Appl Biomater 69 2 (2004) 183-194
    • (2004) J Biomed Mater Res B Appl Biomater , vol.69 , Issue.2 , pp. 183-194
    • Oh, K.T.1    Kim, Y.S.2    Park, Y.S.3
  • 11
    • 0026922624 scopus 로고
    • Biodegradation of restorative metallic systems
    • Lucas L.C., and Lemons J.E. Biodegradation of restorative metallic systems. Adv Dent Res 6 (1992) 32-37
    • (1992) Adv Dent Res , vol.6 , pp. 32-37
    • Lucas, L.C.1    Lemons, J.E.2
  • 12
    • 34250685619 scopus 로고    scopus 로고
    • TruChrome MSDS data sSheet. Rocky Mountain Orthodontics. Rocky Mountain Orthodontics. Available at: http://www.rmortho.com/products/info/MSDS/TruChrome%20Stainless%20Steel.dot. Accessed September 5, 2006.
  • 15
    • 34250664190 scopus 로고    scopus 로고
    • Moffa JP. Physical and mechanical pProperties of gold and base metal alloys. Presented at the Alternative to Gold Alloys in Dentistry. Bethesda (MD), January 24-26, 1977.
  • 17
    • 0018457168 scopus 로고
    • The influence of heat treatments on several types of base-metal removable partial denture alloys
    • Morris H.F., Asgar K., Rowe A.P., et al. The influence of heat treatments on several types of base-metal removable partial denture alloys. J Prosthet Dent 41 4 (1979) 388-395
    • (1979) J Prosthet Dent , vol.41 , Issue.4 , pp. 388-395
    • Morris, H.F.1    Asgar, K.2    Rowe, A.P.3
  • 18
    • 34250627481 scopus 로고    scopus 로고
    • Elgiloy MSDS data sheet. Rocky Mountain Orthodontics: Rocky Mountain Orthodontics. Available at: http://www.rmortho.com/products/info/MSDS/Elgiloy.dot. Accessed September 5, 2006.
  • 19
    • 34250623518 scopus 로고    scopus 로고
    • Disegi J. AO/ASIF Materials Technical Commission. Titanium-6% aluminum-7% niobium implant material; AO/ASIF Materials Technical Commission, Switzerland; 1993.
  • 20
    • 34250641389 scopus 로고    scopus 로고
    • Disegi J. AO/ASIF Materials Expert Group. Wrought titanium 15% molybdenum implant material; AO/ASIF Materials Technical Commission, Switzerland; 2003.
  • 21
    • 0018344605 scopus 로고
    • An evaluation of beta titanium alloys for use in orthodontic appliances
    • Goldberg J., and Burstone C.J. An evaluation of beta titanium alloys for use in orthodontic appliances. J Dent Res 58 2 (1979) 593-599
    • (1979) J Dent Res , vol.58 , Issue.2 , pp. 593-599
    • Goldberg, J.1    Burstone, C.J.2
  • 22
    • 0021412467 scopus 로고
    • Casting properties of Ni-Ti shape memory alloy
    • Takahashi J., Okazaki M., Kimura H., et al. Casting properties of Ni-Ti shape memory alloy. J Biomed Mater Res 18 4 (1984) 427-434
    • (1984) J Biomed Mater Res , vol.18 , Issue.4 , pp. 427-434
    • Takahashi, J.1    Okazaki, M.2    Kimura, H.3
  • 24
    • 0018831556 scopus 로고
    • Beta titanium: a new orthodontic alloy
    • Burstone C.J., and Goldberg A.J. Beta titanium: a new orthodontic alloy. Am J Orthod 77 2 (1980) 121-132
    • (1980) Am J Orthod , vol.77 , Issue.2 , pp. 121-132
    • Burstone, C.J.1    Goldberg, A.J.2
  • 25
    • 0002631931 scopus 로고
    • Mechanical properties of stainless steel orthodontic archwires
    • Kusy R., Dilley G., and Whitley J. Mechanical properties of stainless steel orthodontic archwires. Clin Mater 3 (1988) 41-59
    • (1988) Clin Mater , vol.3 , pp. 41-59
    • Kusy, R.1    Dilley, G.2    Whitley, J.3
  • 26
    • 0033072152 scopus 로고    scopus 로고
    • Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
    • Kim H., and Johnson J.W. Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires. Angle Orthod 69 1 (1999) 39-44
    • (1999) Angle Orthod , vol.69 , Issue.1 , pp. 39-44
    • Kim, H.1    Johnson, J.W.2
  • 27
    • 0020724695 scopus 로고
    • The chloride corrosion behaviour of four orthodontic wires
    • Sarkar N.K., Redmond W., Schwaninger B., et al. The chloride corrosion behaviour of four orthodontic wires. J Oral Rehabil 10 2 (1983) 121-128
    • (1983) J Oral Rehabil , vol.10 , Issue.2 , pp. 121-128
    • Sarkar, N.K.1    Redmond, W.2    Schwaninger, B.3
  • 28
    • 33644657458 scopus 로고    scopus 로고
    • Surface analysis and corrosion resistance of different stainless steel orthodontic brackets in artificial saliva
    • Lin M.C., Lin S.C., Lee T.H., et al. Surface analysis and corrosion resistance of different stainless steel orthodontic brackets in artificial saliva. Angle Orthod 76 2 (2006) 322-329
    • (2006) Angle Orthod , vol.76 , Issue.2 , pp. 322-329
    • Lin, M.C.1    Lin, S.C.2    Lee, T.H.3
  • 29
    • 0041804110 scopus 로고    scopus 로고
    • In vitro surface corrosion of stainless steel and NiTi orthodontic appliances
    • Shin J.S., Oh K.T., and Hwang C.J. In vitro surface corrosion of stainless steel and NiTi orthodontic appliances. Aust Orthod J 19 1 (2003) 13-18
    • (2003) Aust Orthod J , vol.19 , Issue.1 , pp. 13-18
    • Shin, J.S.1    Oh, K.T.2    Hwang, C.J.3
  • 30
    • 0029183960 scopus 로고
    • In vitro release of nickel and chromium from different types of simulated orthodontic appliances
    • Kerosuo H., Moe G., and Kleven E. In vitro release of nickel and chromium from different types of simulated orthodontic appliances. Angle Orthod 65 2 (1995) 111-116
    • (1995) Angle Orthod , vol.65 , Issue.2 , pp. 111-116
    • Kerosuo, H.1    Moe, G.2    Kleven, E.3
  • 31
    • 0033174844 scopus 로고    scopus 로고
    • Ion release from orthodontic appliances
    • Staffolani N., Damiani F., Lilli C., et al. Ion release from orthodontic appliances. J Dent 27 6 (1999) 449-454
    • (1999) J Dent , vol.27 , Issue.6 , pp. 449-454
    • Staffolani, N.1    Damiani, F.2    Lilli, C.3
  • 32
    • 0036716115 scopus 로고    scopus 로고
    • The use of stainless steel crowns
    • Seale N.S. The use of stainless steel crowns. Pediatr Dent 24 5 (2002) 501-505
    • (2002) Pediatr Dent , vol.24 , Issue.5 , pp. 501-505
    • Seale, N.S.1
  • 33
    • 27744438990 scopus 로고    scopus 로고
    • General dental practitioners' views on the use of stainless steel crowns to restore primary molars
    • [discussion: 441]
    • Threlfall A.G., Pilkington L., Milsom K.M., et al. General dental practitioners' views on the use of stainless steel crowns to restore primary molars. Br Dent J 199 7 (2005) 453-455 [discussion: 441]
    • (2005) Br Dent J , vol.199 , Issue.7 , pp. 453-455
    • Threlfall, A.G.1    Pilkington, L.2    Milsom, K.M.3
  • 34
    • 0344334857 scopus 로고
    • Fixation of bones by plates and screws
    • Peterson L. Fixation of bones by plates and screws. J Bone Joint Surg 29 (1947) 335-347
    • (1947) J Bone Joint Surg , vol.29 , pp. 335-347
    • Peterson, L.1
  • 35
    • 0014310313 scopus 로고
    • Mechanical properties and stress relief of stainless steel orthodontic wire
    • Howe G.L., Greener E.H., and Crimmins D.S. Mechanical properties and stress relief of stainless steel orthodontic wire. Angle Orthod 38 3 (1968) 244-249
    • (1968) Angle Orthod , vol.38 , Issue.3 , pp. 244-249
    • Howe, G.L.1    Greener, E.H.2    Crimmins, D.S.3
  • 36
    • 0020012019 scopus 로고
    • Corrosion of orthodontic bracket bases
    • Maijer R., and Smith D.C. Corrosion of orthodontic bracket bases. Am J Orthod 81 1 (1982) 43-48
    • (1982) Am J Orthod , vol.81 , Issue.1 , pp. 43-48
    • Maijer, R.1    Smith, D.C.2
  • 37
    • 34250649980 scopus 로고    scopus 로고
    • ASTM Standard Specification for wrought 18-chromium 14-nickel 2.5-molybdenum stainless steel bar and wire for surgical implants (UNS S31673) F138-00. Annual book of ASTM standards. Section 13 - Medical devices and services, volume 13.01. West Conshohocken (PA): American Society for Testing and Materials; 2000.
  • 38
    • 0038722961 scopus 로고    scopus 로고
    • Comparison of the corrosion fatigue of BioDur 108 to 316LS.S. and 22Cr-13Ni-5Mn stainless steels
    • Winters G.L., and Nutt M.J. (Eds), ASTM International, West Conshohocken (PA)
    • Zardiackas L.D., Roach M.D., Williamson R.S., et al. Comparison of the corrosion fatigue of BioDur 108 to 316LS.S. and 22Cr-13Ni-5Mn stainless steels. In: Winters G.L., and Nutt M.J. (Eds). Stainless steels for medical and surgical applications. ASTM 1438 (2003), ASTM International, West Conshohocken (PA) 194-210
    • (2003) Stainless steels for medical and surgical applications. ASTM 1438 , pp. 194-210
    • Zardiackas, L.D.1    Roach, M.D.2    Williamson, R.S.3
  • 39
    • 34250646878 scopus 로고    scopus 로고
    • Fraker AC. Corrosion of metallic implants and prosthetic devices. Metals handbook. 9th edition, vol. 13. Metals Park (OH): ASM International; 1987. p. 1324-35.
  • 40
    • 0032779294 scopus 로고    scopus 로고
    • The influence of surface condition on the localized corrosion of 316L stainless steel orthopaedic implants
    • Beddoes J., and Bucci K. The influence of surface condition on the localized corrosion of 316L stainless steel orthopaedic implants. J Mater Sci Mater Med 10 (1999) 389-394
    • (1999) J Mater Sci Mater Med , vol.10 , pp. 389-394
    • Beddoes, J.1    Bucci, K.2
  • 41
    • 0038174777 scopus 로고    scopus 로고
    • Comparison of the notch sensitivity and stress corrosion cracking of a low-nickel stainless steel to 316LS and 22Cr-13Ni-5Mn stainless steels
    • Winters G.L., and Nutt M.J. (Eds), ASTM International, West Conshohocken (PA)
    • Zardiackas L.D., Roach M.D., Williamson R.S., et al. Comparison of the notch sensitivity and stress corrosion cracking of a low-nickel stainless steel to 316LS and 22Cr-13Ni-5Mn stainless steels. In: Winters G.L., and Nutt M.J. (Eds). Stainless steels for medical and surgical applications. ASTM 1438 (2003), ASTM International, West Conshohocken (PA) 154-167
    • (2003) Stainless steels for medical and surgical applications. ASTM 1438 , pp. 154-167
    • Zardiackas, L.D.1    Roach, M.D.2    Williamson, R.S.3
  • 42
    • 13844299041 scopus 로고    scopus 로고
    • Roach MD, McGuire J, Williamson RS, et al. Characterization of the torsional properties of stainless steel and titanium alloys used as implants. Proceedings of the 7th World Biomaterials Congress. Sydney (Australia); May 17-21, 2004.
  • 43
    • 0038513576 scopus 로고    scopus 로고
    • Comparison of anodic polarization and galvanic corrosion of a low-nickel stainless steel to 316LS and 22Cr-13Ni-5Mn stainless steels
    • Winters G.L., and Nutt M.J. (Eds), ASTM International, West Conshohocken (PA)
    • Zardiackas L.D., Roach M.D., Williamson R.S., et al. Comparison of anodic polarization and galvanic corrosion of a low-nickel stainless steel to 316LS and 22Cr-13Ni-5Mn stainless steels. In: Winters G.L., and Nutt M.J. (Eds). Stainless steels for medical and surgical applications. ASTM 1438 (2003), ASTM International, West Conshohocken (PA)
    • (2003) Stainless steels for medical and surgical applications. ASTM 1438
    • Zardiackas, L.D.1    Roach, M.D.2    Williamson, R.S.3
  • 44
    • 33746954635 scopus 로고    scopus 로고
    • Comparison of the corrosion fatigue characteristics of 23Mn-21Cr-1Mo low nickel, 22Cr-13Ni-5Mn, and 18Cr-14Ni-2.5Mo stainless steels
    • Roach M.D., Williamson R.S., and Zardiackas L.D. Comparison of the corrosion fatigue characteristics of 23Mn-21Cr-1Mo low nickel, 22Cr-13Ni-5Mn, and 18Cr-14Ni-2.5Mo stainless steels. Journal of ASTM International 3 5 (2006) 1-11
    • (2006) Journal of ASTM International , vol.3 , Issue.5 , pp. 1-11
    • Roach, M.D.1    Williamson, R.S.2    Zardiackas, L.D.3
  • 46
    • 0024444245 scopus 로고
    • Nickel, chromium, cobalt dental alloys and allergic reactions: an overview
    • Hildebrand H.F., Veron C., and Martin P. Nickel, chromium, cobalt dental alloys and allergic reactions: an overview. Biomaterials 10 8 (1989) 545-548
    • (1989) Biomaterials , vol.10 , Issue.8 , pp. 545-548
    • Hildebrand, H.F.1    Veron, C.2    Martin, P.3
  • 47
    • 34250615769 scopus 로고    scopus 로고
    • Carpenter technology corporation BioDur 108 alloy data sheet. Available at: http://www.cartech.com/common/frames.html?http://cartech.ides.com/ListSearch.aspx?ST=DESC&i=101&leftn=sao_products&lefto=nav_tlo&lefti=nav_tlo3. Accessed September 5, 2006.
  • 48
    • 0034450007 scopus 로고    scopus 로고
    • Stainless steel in bone surgery
    • Disegi J.A., and Eschbach L. Stainless steel in bone surgery. Injury 31 Suppl 4 (2000) 2-6
    • (2000) Injury , vol.31 , Issue.SUPPL. 4 , pp. 2-6
    • Disegi, J.A.1    Eschbach, L.2
  • 50
    • 34250621235 scopus 로고    scopus 로고
    • Carpenter specialty alloys Corporation. BioDur 108 alloy data sheet. Reading (PA): CRS Holdings, Inc.; 2000.
  • 51
    • 34250619455 scopus 로고    scopus 로고
    • Ticonium. Available at: http://www.cmpindustry.com/company.asp. Accessed September 4, 2006.
  • 52
    • 34250613340 scopus 로고    scopus 로고
    • Touceda EG. Denture, 2,089,587. United States Patent Office; August 10, 1937.
  • 55
    • 0040462566 scopus 로고
    • Composition and properties of noble and precious metal alloys
    • Smith D.C., and Williams D.F. (Eds), CRC Press, Boca Raton (FL)
    • Tucillo J., and Cascone P. Composition and properties of noble and precious metal alloys. In: Smith D.C., and Williams D.F. (Eds). CRC series in biocompatibility: biocompatibility of dental materials (1982), CRC Press, Boca Raton (FL) 19-36
    • (1982) CRC series in biocompatibility: biocompatibility of dental materials , pp. 19-36
    • Tucillo, J.1    Cascone, P.2
  • 56
    • 0021307512 scopus 로고
    • Auger chemical analysis of oxides on Ni-Cr alloys
    • Baran G. Auger chemical analysis of oxides on Ni-Cr alloys. J Dent Res 63 1 (1984) 76-80
    • (1984) J Dent Res , vol.63 , Issue.1 , pp. 76-80
    • Baran, G.1
  • 57
    • 0020853968 scopus 로고
    • The metallurgy of Ni-Cr alloys for fixed prosthodontics
    • Baran G.R. The metallurgy of Ni-Cr alloys for fixed prosthodontics. J Prosthet Dent 50 5 (1983) 639-650
    • (1983) J Prosthet Dent , vol.50 , Issue.5 , pp. 639-650
    • Baran, G.R.1
  • 58
    • 0027639179 scopus 로고
    • Surface analysis of nickel-chromium dental alloys
    • Bumgardner J.D., and Lucas L.C. Surface analysis of nickel-chromium dental alloys. Dent Mater 9 4 (1993) 252-259
    • (1993) Dent Mater , vol.9 , Issue.4 , pp. 252-259
    • Bumgardner, J.D.1    Lucas, L.C.2
  • 59
    • 0022114745 scopus 로고
    • Beryllium localization in base metal dental casting alloys
    • Covington J.S., McBride M.A., Slagle W.F., et al. Beryllium localization in base metal dental casting alloys. J Biomed Mater Res 19 7 (1985) 747-750
    • (1985) J Biomed Mater Res , vol.19 , Issue.7 , pp. 747-750
    • Covington, J.S.1    McBride, M.A.2    Slagle, W.F.3
  • 60
    • 0022098004 scopus 로고
    • Quantization of nickel and beryllium leakage from base metal casting alloys
    • Covington J.S., McBride M.A., Slagle W.F., et al. Quantization of nickel and beryllium leakage from base metal casting alloys. J Prosthet Dent 54 1 (1985) 127-136
    • (1985) J Prosthet Dent , vol.54 , Issue.1 , pp. 127-136
    • Covington, J.S.1    McBride, M.A.2    Slagle, W.F.3
  • 61
    • 0034566812 scopus 로고    scopus 로고
    • Use of x-ray photoelectron spectroscopy and cyclic polarization to evaluate the corrosion behavior of six nickel-chromium alloys before and after porcelain-fused-to-metal firing
    • Roach M.D., Wolan J.T., Parsell D.E., et al. Use of x-ray photoelectron spectroscopy and cyclic polarization to evaluate the corrosion behavior of six nickel-chromium alloys before and after porcelain-fused-to-metal firing. J Prosthet Dent 84 6 (2000) 623-634
    • (2000) J Prosthet Dent , vol.84 , Issue.6 , pp. 623-634
    • Roach, M.D.1    Wolan, J.T.2    Parsell, D.E.3
  • 62
    • 0030119324 scopus 로고    scopus 로고
    • Castability, opaque masking, and porcelain bonding of 17 porcelain-fused-to-metal alloys
    • O'Connor R.P., Mackert Jr. J.R., Myers M.L., et al. Castability, opaque masking, and porcelain bonding of 17 porcelain-fused-to-metal alloys. J Prosthet Dent 75 4 (1996) 367-374
    • (1996) J Prosthet Dent , vol.75 , Issue.4 , pp. 367-374
    • O'Connor, R.P.1    Mackert Jr., J.R.2    Myers, M.L.3
  • 63
    • 0000037320 scopus 로고
    • In vitro corrosion analyses of nickel-base alloys
    • Lee J., Lucas L., O'Neal J., et al. In vitro corrosion analyses of nickel-base alloys. J Dent Res 63 DMG 1285 (1985) 1-21
    • (1985) J Dent Res , vol.63 , Issue.DMG 1285 , pp. 1-21
    • Lee, J.1    Lucas, L.2    O'Neal, J.3
  • 64
    • 0017685489 scopus 로고
    • Corrosion resistance of nickel-chromium dental casting alloys
    • Meyer J. Corrosion resistance of nickel-chromium dental casting alloys. Corrosion Science 17 (1977) 971-982
    • (1977) Corrosion Science , vol.17 , pp. 971-982
    • Meyer, J.1
  • 65
    • 0027596344 scopus 로고
    • Studies on the influence of Be content on the corrosion behavior and mechanical properties of Ni-25Cr-10Mo alloys
    • Geis-Gerstorfer J., and Passler K. Studies on the influence of Be content on the corrosion behavior and mechanical properties of Ni-25Cr-10Mo alloys. Dent Mater 9 3 (1993) 177-181
    • (1993) Dent Mater , vol.9 , Issue.3 , pp. 177-181
    • Geis-Gerstorfer, J.1    Passler, K.2
  • 66
    • 0026115971 scopus 로고
    • Ion release from Ni-Cr-Mo and Co-Cr-Mo casting alloys
    • Geis-Gerstorfer J., Sauer K.H., and Passler K. Ion release from Ni-Cr-Mo and Co-Cr-Mo casting alloys. Int J Prosthodont 4 2 (1991) 152-158
    • (1991) Int J Prosthodont , vol.4 , Issue.2 , pp. 152-158
    • Geis-Gerstorfer, J.1    Sauer, K.H.2    Passler, K.3
  • 67
    • 0029355343 scopus 로고
    • Cellular response to metallic ions released from nickel-chromium dental alloys
    • Bumgardner J.D., and Lucas L.C. Cellular response to metallic ions released from nickel-chromium dental alloys. J Dent Res 74 8 (1995) 1521-1527
    • (1995) J Dent Res , vol.74 , Issue.8 , pp. 1521-1527
    • Bumgardner, J.D.1    Lucas, L.C.2
  • 68
    • 0032252669 scopus 로고    scopus 로고
    • Effect of pH on element release from dental casting alloys
    • Wataha J.C., Lockwood P.E., Khajotia S.S., et al. Effect of pH on element release from dental casting alloys. J Prosthet Dent 80 6 (1998) 691-698
    • (1998) J Prosthet Dent , vol.80 , Issue.6 , pp. 691-698
    • Wataha, J.C.1    Lockwood, P.E.2    Khajotia, S.S.3
  • 69
    • 0026929858 scopus 로고
    • Leaching of nickel, chromium, and beryllium ions from base metal alloy in an artificial oral environment
    • Tai Y., De Long R., Goodkind R.J., et al. Leaching of nickel, chromium, and beryllium ions from base metal alloy in an artificial oral environment. J Prosthet Dent 68 4 (1992) 692-697
    • (1992) J Prosthet Dent , vol.68 , Issue.4 , pp. 692-697
    • Tai, Y.1    De Long, R.2    Goodkind, R.J.3
  • 70
    • 0021695168 scopus 로고
    • Changes in mechanical properties and microstructure following heat treatment of a nickel-chromium base alloy
    • Winkler S., Morris H.F., and Monteiro J.M. Changes in mechanical properties and microstructure following heat treatment of a nickel-chromium base alloy. J Prosthet Dent 52 6 (1984) 821-827
    • (1984) J Prosthet Dent , vol.52 , Issue.6 , pp. 821-827
    • Winkler, S.1    Morris, H.F.2    Monteiro, J.M.3
  • 71
    • 0022796123 scopus 로고
    • Influence of heat treatment on the surface texture of an etched cast nickel-chromium base alloy: an evaluation by profilometric records
    • Marinello C.P., Luthy H., and Scharer P. Influence of heat treatment on the surface texture of an etched cast nickel-chromium base alloy: an evaluation by profilometric records. J Prosthet Dent 56 4 (1986) 431-435
    • (1986) J Prosthet Dent , vol.56 , Issue.4 , pp. 431-435
    • Marinello, C.P.1    Luthy, H.2    Scharer, P.3
  • 72
    • 0024617233 scopus 로고
    • Veterans Administration Cooperative Studies Project No. 147/242. Part VII: the mechanical properties of metal ceramic alloys as cast and after simulated porcelain firing
    • Morris H.F. Veterans Administration Cooperative Studies Project No. 147/242. Part VII: the mechanical properties of metal ceramic alloys as cast and after simulated porcelain firing. J Prosthet Dent 61 2 (1989) 160-169
    • (1989) J Prosthet Dent , vol.61 , Issue.2 , pp. 160-169
    • Morris, H.F.1
  • 73
    • 0020456135 scopus 로고
    • Electrochemical study of corrosion in Ni-Cr dental alloys
    • de De Micheli S.M., and Riesgo O. Electrochemical study of corrosion in Ni-Cr dental alloys. Biomaterials 3 4 (1982) 209-212
    • (1982) Biomaterials , vol.3 , Issue.4 , pp. 209-212
    • de De Micheli, S.M.1    Riesgo, O.2
  • 75
    • 0021503786 scopus 로고
    • Biocompatibility of nickel based dental alloys
    • Moffa J.P. Biocompatibility of nickel based dental alloys. CDA J 12 10 (1984) 45-51
    • (1984) CDA J , vol.12 , Issue.10 , pp. 45-51
    • Moffa, J.P.1
  • 76
    • 0022792398 scopus 로고
    • Dental implications of nickel hypersensitivity
    • Jones T.K., Hansen C.A., Singer M.T., et al. Dental implications of nickel hypersensitivity. J Prosthet Dent 56 4 (1986) 507-509
    • (1986) J Prosthet Dent , vol.56 , Issue.4 , pp. 507-509
    • Jones, T.K.1    Hansen, C.A.2    Singer, M.T.3
  • 77
    • 34250666512 scopus 로고    scopus 로고
    • Haynes E. Metal alloy, 873,745. United States Patent Office; December 17, 1907.
  • 78
    • 0040421841 scopus 로고
    • A survey of dental alloys
    • Lane J.R. A survey of dental alloys. J Am Dent Assoc 39 (1949) 414-437
    • (1949) J Am Dent Assoc , vol.39 , pp. 414-437
    • Lane, J.R.1
  • 79
    • 34250649572 scopus 로고    scopus 로고
    • Prange CH. Cast metallic denture, 1,958,446: United States Patent Office; May 15, 1934.
  • 81
    • 5244258774 scopus 로고
    • Electrolysis controlling factor in the use of metals in treating fractures
    • Venable C.S., and Stuck W.G. Electrolysis controlling factor in the use of metals in treating fractures. J Am Med Assoc 111 13 (1938) 1349-1352
    • (1938) J Am Med Assoc , vol.111 , Issue.13 , pp. 1349-1352
    • Venable, C.S.1    Stuck, W.G.2
  • 82
    • 0001220717 scopus 로고
    • The effects on bone of the presence of metals based upon electrolysis
    • Venable C.S., Stuck W.G., and Beach A. The effects on bone of the presence of metals based upon electrolysis. Annals of Surgery 105 6 (1937) 917-938
    • (1937) Annals of Surgery , vol.105 , Issue.6 , pp. 917-938
    • Venable, C.S.1    Stuck, W.G.2    Beach, A.3
  • 83
    • 0021222925 scopus 로고
    • Ductility and structure of some cobalt-base dental casting alloys
    • Hero H., Syverud M., Gjonnes J., et al. Ductility and structure of some cobalt-base dental casting alloys. Biomaterials 5 4 (1984) 201-208
    • (1984) Biomaterials , vol.5 , Issue.4 , pp. 201-208
    • Hero, H.1    Syverud, M.2    Gjonnes, J.3
  • 84
    • 0002901015 scopus 로고
    • Effect of microstructure on physical properties of cobalt alloys
    • Asgar K., and Peyton F.A. Effect of microstructure on physical properties of cobalt alloys. J Dent Res 40 1 (1961) 63-72
    • (1961) J Dent Res , vol.40 , Issue.1 , pp. 63-72
    • Asgar, K.1    Peyton, F.A.2
  • 85
    • 0015884966 scopus 로고
    • In vitro corrosion resistance of new dental alloys
    • Sarkar N.K., and Greener E.H. In vitro corrosion resistance of new dental alloys. Biomater Med Devices Artif Organs 1 1 (1973) 121-129
    • (1973) Biomater Med Devices Artif Organs , vol.1 , Issue.1 , pp. 121-129
    • Sarkar, N.K.1    Greener, E.H.2
  • 86
    • 0026895146 scopus 로고
    • Corrosion testing by potentiodynamic polarization in various electrolytes
    • Holland R.I. Corrosion testing by potentiodynamic polarization in various electrolytes. Dent Mater 8 4 (1992) 241-245
    • (1992) Dent Mater , vol.8 , Issue.4 , pp. 241-245
    • Holland, R.I.1
  • 87
    • 0023394453 scopus 로고
    • Corrosion rate studies: measurements of corrosion rates of some non-precious dental alloys in artificial saliva
    • Wiegman-Ho L., and Ketelaar J.A. Corrosion rate studies: measurements of corrosion rates of some non-precious dental alloys in artificial saliva. J Dent 15 4 (1987) 166-170
    • (1987) J Dent , vol.15 , Issue.4 , pp. 166-170
    • Wiegman-Ho, L.1    Ketelaar, J.A.2
  • 88
    • 0029314586 scopus 로고
    • Corrosion evaluation of recasting non-precious dental alloys
    • Khamis E., and Seddik M. Corrosion evaluation of recasting non-precious dental alloys. Int Dent J 45 3 (1995) 209-217
    • (1995) Int Dent J , vol.45 , Issue.3 , pp. 209-217
    • Khamis, E.1    Seddik, M.2
  • 89
    • 14644444536 scopus 로고    scopus 로고
    • Corrosion resistance of cobalt-chromium and palladium-silver alloys used in fixed prosthetic restorations
    • Viennot S., Dalard F., Lissac M., et al. Corrosion resistance of cobalt-chromium and palladium-silver alloys used in fixed prosthetic restorations. Eur J Oral Sci 113 1 (2005) 90-95
    • (2005) Eur J Oral Sci , vol.113 , Issue.1 , pp. 90-95
    • Viennot, S.1    Dalard, F.2    Lissac, M.3
  • 90
    • 2942613210 scopus 로고    scopus 로고
    • Comparison of metal release from various metallic biomaterials in vitro
    • Okazaki Y., and Gotoh E. Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 26 1 (2005) 11-21
    • (2005) Biomaterials , vol.26 , Issue.1 , pp. 11-21
    • Okazaki, Y.1    Gotoh, E.2
  • 92
    • 34250613341 scopus 로고    scopus 로고
    • Elgiloy. Available at: http://www.elgiloy.com/history.html. Accessed August 24, 2006.
  • 93
    • 0017124812 scopus 로고
    • Heat treatment of cobalt-chromium alloy wire
    • Fillmore G.M., and Tomlinson J.L. Heat treatment of cobalt-chromium alloy wire. Angle Orthod 46 2 (1976) 187-195
    • (1976) Angle Orthod , vol.46 , Issue.2 , pp. 187-195
    • Fillmore, G.M.1    Tomlinson, J.L.2
  • 94
    • 0018463411 scopus 로고
    • Heat treatment of cobalt-chromium alloys of various tempers
    • Fillmore G.M., and Tomlinson J.L. Heat treatment of cobalt-chromium alloys of various tempers. Angle Orthod 49 2 (1979) 126-130
    • (1979) Angle Orthod , vol.49 , Issue.2 , pp. 126-130
    • Fillmore, G.M.1    Tomlinson, J.L.2
  • 95
    • 34250656827 scopus 로고    scopus 로고
    • Rocky Mountain Orthodontics. Product Catalog. Available at: http://www.rockymountainorthodontics.com/assets/content.html. Accessed September 4, 2006.
  • 97
    • 0042883748 scopus 로고    scopus 로고
    • Relative stiffness of beta titanium archwires
    • Johnson E. Relative stiffness of beta titanium archwires. Angle Orthod 73 3 (2003) 259-269
    • (2003) Angle Orthod , vol.73 , Issue.3 , pp. 259-269
    • Johnson, E.1
  • 98
    • 0022685056 scopus 로고
    • Comparison of bending and tension tests for orthodontic wires
    • Asgharnia M.K., and Brantley W.A. Comparison of bending and tension tests for orthodontic wires. Am J Orthod 89 3 (1986) 228-236
    • (1986) Am J Orthod , vol.89 , Issue.3 , pp. 228-236
    • Asgharnia, M.K.1    Brantley, W.A.2
  • 99
    • 0016483665 scopus 로고
    • Cast vs. wrought cobalt-chromium surgical implant alloys
    • Devine T.M., and Wulff J. Cast vs. wrought cobalt-chromium surgical implant alloys. J Biomed Mater Res 9 (1975) 151-167
    • (1975) J Biomed Mater Res , vol.9 , pp. 151-167
    • Devine, T.M.1    Wulff, J.2
  • 100
    • 0019068816 scopus 로고
    • Anodic polarization behavior of Ti-Ni and Ti-6A1-4V in simulated physiological solutions
    • Speck K.M., and Fraker A.C. Anodic polarization behavior of Ti-Ni and Ti-6A1-4V in simulated physiological solutions. J Dent Res 59 10 (1980) 1590-1595
    • (1980) J Dent Res , vol.59 , Issue.10 , pp. 1590-1595
    • Speck, K.M.1    Fraker, A.C.2
  • 101
    • 34250634684 scopus 로고    scopus 로고
    • Disegi J. AO/ASIF Unalloyed tTitanium implant material; 1991.
  • 102
    • 20544473427 scopus 로고    scopus 로고
    • Nonalloyed titanium as a bioinert metal-a review
    • Tschernitschek H., Borchers L., and Geurtsen W. Nonalloyed titanium as a bioinert metal-a review. Quintessence Int 36 7-8 (2005) 523-530
    • (2005) Quintessence Int , vol.36 , Issue.7-8 , pp. 523-530
    • Tschernitschek, H.1    Borchers, L.2    Geurtsen, W.3
  • 103
    • 34250641776 scopus 로고    scopus 로고
    • Kroll W. Method for manufacturing tTitanium and alloys tThereof, 2,205,854. Uniteds States Patent Office; June 25, 1940.
  • 105
    • 0001289258 scopus 로고
    • Reaction of bone to multiple metallic implants
    • Bothe R., Beaton L., and Davenport H. Reaction of bone to multiple metallic implants. J Surg Gynecol Obstet 71 5 (1940) 598-602
    • (1940) J Surg Gynecol Obstet , vol.71 , Issue.5 , pp. 598-602
    • Bothe, R.1    Beaton, L.2    Davenport, H.3
  • 106
    • 2542542518 scopus 로고
    • Titanium, a metal for surgery
    • Leventhal G.S. Titanium, a metal for surgery. J Bone Joint Surg 33-A 2 (1951) 473-474
    • (1951) J Bone Joint Surg , vol.33 -A , Issue.2 , pp. 473-474
    • Leventhal, G.S.1
  • 107
    • 0014636440 scopus 로고
    • Intra-osseous anchorage of dental prostheses. I. Experimental studies
    • Bra{hook above}nemark P.I., Adell R., Breine U., et al. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 3 2 (1969) 81-100
    • (1969) Scand J Plast Reconstr Surg , vol.3 , Issue.2 , pp. 81-100
    • Branemark, P.I.1    Adell, R.2    Breine, U.3
  • 108
    • 0027616999 scopus 로고
    • Titanium and titanium alloys as dental materials
    • Lautenschlager E.P., and Monaghan P. Titanium and titanium alloys as dental materials. Int Dent J 43 3 (1993) 245-253
    • (1993) Int Dent J , vol.43 , Issue.3 , pp. 245-253
    • Lautenschlager, E.P.1    Monaghan, P.2
  • 109
    • 0030155746 scopus 로고    scopus 로고
    • Titanium for prosthodontic applications: a review of the literature
    • Wang R.R., and Fenton A. Titanium for prosthodontic applications: a review of the literature. Quintessence Int 27 6 (1996) 401-408
    • (1996) Quintessence Int , vol.27 , Issue.6 , pp. 401-408
    • Wang, R.R.1    Fenton, A.2
  • 110
    • 0038281113 scopus 로고    scopus 로고
    • Titanium applications in dentistry
    • Titanium applications in dentistry. J Am Dent Assoc 134 3 (2003) 347-349
    • (2003) J Am Dent Assoc , vol.134 , Issue.3 , pp. 347-349
  • 111
    • 0027142077 scopus 로고
    • Mold filling and porosity in castings of titanium
    • Hero H., Syverud M., and Waarli M. Mold filling and porosity in castings of titanium. Dent Mater 9 1 (1993) 15-18
    • (1993) Dent Mater , vol.9 , Issue.1 , pp. 15-18
    • Hero, H.1    Syverud, M.2    Waarli, M.3
  • 112
    • 0033070380 scopus 로고    scopus 로고
    • Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures
    • Walter M., Reppel P.D., Boning K., et al. Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures. J Oral Rehabil 26 2 (1999) 91-96
    • (1999) J Oral Rehabil , vol.26 , Issue.2 , pp. 91-96
    • Walter, M.1    Reppel, P.D.2    Boning, K.3
  • 113
    • 0034328117 scopus 로고    scopus 로고
    • Bond strength of three porcelains to two forms of titanium using two firing atmospheres
    • Atsu S., and Berksun S. Bond strength of three porcelains to two forms of titanium using two firing atmospheres. J Prosthet Dent 84 5 (2000) 567-574
    • (2000) J Prosthet Dent , vol.84 , Issue.5 , pp. 567-574
    • Atsu, S.1    Berksun, S.2
  • 114
    • 0024345249 scopus 로고
    • Studies of Ti alloys for dental castings
    • Taira M., Moser J.B., and Greener E.H. Studies of Ti alloys for dental castings. Dent Mater 5 1 (1989) 45-50
    • (1989) Dent Mater , vol.5 , Issue.1 , pp. 45-50
    • Taira, M.1    Moser, J.B.2    Greener, E.H.3
  • 115
    • 0033289498 scopus 로고    scopus 로고
    • In vitro corrosion behaviour and metallic ion release of different prosthodontic alloys
    • Gil F.J., Sanchez L.A., Espias A., et al. In vitro corrosion behaviour and metallic ion release of different prosthodontic alloys. Int Dent J 49 6 (1999) 361-367
    • (1999) Int Dent J , vol.49 , Issue.6 , pp. 361-367
    • Gil, F.J.1    Sanchez, L.A.2    Espias, A.3
  • 116
    • 0026124943 scopus 로고
    • The effect of oral topical fluorides on the surface of commercially pure titanium
    • Siirila H.S., and Kononen M. The effect of oral topical fluorides on the surface of commercially pure titanium. Int J Oral Maxillofac Implants 6 1 (1991) 50-54
    • (1991) Int J Oral Maxillofac Implants , vol.6 , Issue.1 , pp. 50-54
    • Siirila, H.S.1    Kononen, M.2
  • 117
    • 34250680016 scopus 로고
    • Intra-osseous implants utilized as fixed bridge abutments
    • Linkow L. Intra-osseous implants utilized as fixed bridge abutments. Journal of Oral Implants and Transplants 10 (1964) 17-23
    • (1964) Journal of Oral Implants and Transplants , vol.10 , pp. 17-23
    • Linkow, L.1
  • 118
    • 0029396992 scopus 로고
    • A thousand years of dental implants: a definitive history-part 2
    • 1132, 1134, 1136
    • Ring M.E. A thousand years of dental implants: a definitive history-part 2. Compend Contin Educ Dent 16 11 (1995) 1132, 1134, 1136
    • (1995) Compend Contin Educ Dent , vol.16 , Issue.11
    • Ring, M.E.1
  • 119
    • 0033087665 scopus 로고    scopus 로고
    • Dental implant materials: commercially pure titanium and titanium alloys
    • McCracken M. Dental implant materials: commercially pure titanium and titanium alloys. J Prosthodont 8 1 (1999) 40-43
    • (1999) J Prosthodont , vol.8 , Issue.1 , pp. 40-43
    • McCracken, M.1
  • 120
    • 33744793215 scopus 로고    scopus 로고
    • Comparison of stress corrosion cracking characteristics of CP Ti, Ti-6Al-7Nb, Ti-6Al-4V, and Ti-15Mo
    • Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds), ASTM International, West Conshohocken (PA)
    • Williamson R.S., Roach M.D., and Zardiackas L.D. Comparison of stress corrosion cracking characteristics of CP Ti, Ti-6Al-7Nb, Ti-6Al-4V, and Ti-15Mo. In: Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds). Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471) (2006), ASTM International, West Conshohocken (PA) 166-182
    • (2006) Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471) , pp. 166-182
    • Williamson, R.S.1    Roach, M.D.2    Zardiackas, L.D.3
  • 121
    • 33744826806 scopus 로고    scopus 로고
    • Comparison of stress corrosion cracking and corrosion fatigue (anodized and non-anodized grade 4 CP Ti)
    • Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds), ASTM International, West Conshohocken (PA)
    • Zardiackas L.D., Roach M.D., and Williamson R.S. Comparison of stress corrosion cracking and corrosion fatigue (anodized and non-anodized grade 4 CP Ti). In: Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds). Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471) (2006), ASTM International, West Conshohocken (PA) 202-214
    • (2006) Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471) , pp. 202-214
    • Zardiackas, L.D.1    Roach, M.D.2    Williamson, R.S.3
  • 122
    • 33744786785 scopus 로고    scopus 로고
    • Comparison of corrosion fatigue characteristics of CP Ti-grade 4, Ti-6Al-4V ELI, Ti-6Al-7Nb, and Ti-15Mo
    • Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds), ASTM International, West Conshohocken (PA)
    • Roach M.D., Williamson R.S., and Zardiackas L.D. Comparison of corrosion fatigue characteristics of CP Ti-grade 4, Ti-6Al-4V ELI, Ti-6Al-7Nb, and Ti-15Mo. In: Zardiackas L.D., Kraay M.J., and Freese H.L. (Eds). Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471) (2006), ASTM International, West Conshohocken (PA) 183-201
    • (2006) Titanium, niobium, zirconium, and tantalum for medical and surgical applications (STP 1471) , pp. 183-201
    • Roach, M.D.1    Williamson, R.S.2    Zardiackas, L.D.3
  • 123
    • 0024446242 scopus 로고
    • Clinical results with titanium crowns fabricated with machine duplication and spark erosion
    • Andersson M., Bergman B., Bessing C., et al. Clinical results with titanium crowns fabricated with machine duplication and spark erosion. Acta Odontol Scand 47 5 (1989) 279-286
    • (1989) Acta Odontol Scand , vol.47 , Issue.5 , pp. 279-286
    • Andersson, M.1    Bergman, B.2    Bessing, C.3
  • 124
    • 0026860865 scopus 로고
    • Non-cast titanium restorations in fixed prosthodontics
    • Boening K.W., Walter M.H., and Reppel P.D. Non-cast titanium restorations in fixed prosthodontics. J Oral Rehabil 19 3 (1992) 281-287
    • (1992) J Oral Rehabil , vol.19 , Issue.3 , pp. 281-287
    • Boening, K.W.1    Walter, M.H.2    Reppel, P.D.3
  • 125
    • 0028506796 scopus 로고
    • Marginal fit of machine-milled titanium and cast titanium single crowns
    • Leong D., Chai J., Lautenschlager E., et al. Marginal fit of machine-milled titanium and cast titanium single crowns. Int J Prosthodont 7 5 (1994) 440-447
    • (1994) Int J Prosthodont , vol.7 , Issue.5 , pp. 440-447
    • Leong, D.1    Chai, J.2    Lautenschlager, E.3
  • 126
    • 1842869161 scopus 로고    scopus 로고
    • Machinability of cast commercial titanium alloys
    • Watanabe I., Kiyosue S., Ohkubo C., et al. Machinability of cast commercial titanium alloys. J Biomed Mater Res 63 6 (2002) 760-764
    • (2002) J Biomed Mater Res , vol.63 , Issue.6 , pp. 760-764
    • Watanabe, I.1    Kiyosue, S.2    Ohkubo, C.3
  • 127
    • 0034231421 scopus 로고    scopus 로고
    • An overview of nickel-titanium alloys used in dentistry
    • Thompson S.A. An overview of nickel-titanium alloys used in dentistry. Int Endod J 33 4 (2000) 297-310
    • (2000) Int Endod J , vol.33 , Issue.4 , pp. 297-310
    • Thompson, S.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.