메뉴 건너뛰기




Volumn , Issue , 2011, Pages

Filters that remember: Duty cycling analog circuits for long term medical monitoring

Author keywords

Analog filter; Duty cycling; Electro cardiography (ECG)

Indexed keywords

ANALOG FILTERS; ANALOG FRONT END; CIRCUIT DESIGNS; DIGITAL MICROPROCESSORS; DUTY CYCLES; DUTY CYCLING; ELECTRO-CARDIOGRAPHY (ECG); ENERGY EFFICIENT; HARDWARE MODIFICATIONS; HEALTH SYSTEMS; LARGE TIME CONSTANT; POWER GATINGS; QRS COMPLEX DETECTION; RADIO TRANSCEIVERS; RELATIVE CONTRIBUTION; SAMPLING RATES; THREE ORDERS OF MAGNITUDE; WAKE-UP LATENCY;

EID: 84855645511     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1145/2077546.2077550     Document Type: Conference Paper
Times cited : (1)

References (25)
  • 4
    • 84855665341 scopus 로고    scopus 로고
    • Atlas of cardiovascular monitoring
    • P. Brath. Atlas of Cardiovascular Monitoring. Anesthesiology, 93(1):312, 2000.
    • (2000) Anesthesiology , vol.93 , Issue.1 , pp. 312
    • Brath, P.1
  • 6
    • 84855676463 scopus 로고    scopus 로고
    • Decawave. ScenSor, 2011. http://decawave.com/scensor.html.
    • (2011)
  • 10
    • 79951594301 scopus 로고    scopus 로고
    • Just-in-time sampling and pre-filtering for wearable physiological sensors: Going from days to weeks of operation on a single charge
    • N. Hua, A. Lall, J. Romberg, J. J. Xu, M. al'Absi, E. Ertin, S. Kumar, and S. Suri. Just-in-time sampling and pre-filtering for wearable physiological sensors: going from days to weeks of operation on a single charge. In Wireless Health 2010.
    • (2010) Wireless Health
    • Hua, N.1    Lall, A.2    Romberg, J.3    Xu, J.J.4    Al'Absi, M.5    Ertin, E.6    Kumar, S.7    Suri, S.8
  • 11
    • 0031857916 scopus 로고    scopus 로고
    • Intracardiac QRS electrogram width - An arrhythmia detection feature for implantable cardioverter defibrillators: Exercise induced variation as a base for device programming
    • T. Klingenheben, C. Sticherling, M. Skupin, and S. Hohnloser. Intracardiac QRS electrogram width - an arrhythmia detection feature for implantable cardioverter defibrillators: exercise induced variation as a base for device programming. Pacing and clinical electrophysiology, 1998.
    • (1998) Pacing and Clinical Electrophysiology
    • Klingenheben, T.1    Sticherling, C.2    Skupin, M.3    Hohnloser, S.4
  • 13
    • 33645998107 scopus 로고    scopus 로고
    • Digitally assisted analog circuits
    • B. Murmann. Digitally assisted analog circuits. Micro, IEEE, 26(2):38-47, 2006.
    • (2006) Micro, IEEE , vol.26 , Issue.2 , pp. 38-47
    • Murmann, B.1
  • 14
    • 84881169603 scopus 로고    scopus 로고
    • Limits on adc power dissipation
    • M. Steyaert, J. H. Huijsing, and A. H. van Roermund, editors. Springer Netherlands
    • B. Murmann. Limits on adc power dissipation. In M. Steyaert, J. H. Huijsing, and A. H. van Roermund, editors, Analog Circuit Design. Springer Netherlands, 2006.
    • (2006) Analog Circuit Design
    • Murmann, B.1
  • 21
    • 0038311033 scopus 로고    scopus 로고
    • Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction
    • M. Sweeney, A. Hellkamp, K. Ellenbogen, A. Greenspon, R. Freedman, K. Lee, and G. Lamas. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation, 2003.
    • (2003) Circulation
    • Sweeney, M.1    Hellkamp, A.2    Ellenbogen, K.3    Greenspon, A.4    Freedman, R.5    Lee, K.6    Lamas, G.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.