메뉴 건너뛰기




Volumn 21, Issue 8, 1998, Pages 1609-1617

Intracardiac QRS electrogram width - An arrhythmia detection feature for implantable cardioverter defibrillators: Exercise induced variation as a base for device programming

Author keywords

Arrhythmia detection criteria; Implantable defibrillator; Inappropriate shocks

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOVERSION; CLINICAL ARTICLE; CLINICAL TRIAL; COMPUTER PROGRAM; CONTROLLED STUDY; DEFIBRILLATOR; DEVICE; ELECTROCARDIOGRAPHY; EXERCISE; FEMALE; HEART ARRHYTHMIA; HEART DEPOLARIZATION; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; MALE; QRS COMPLEX;

EID: 0031857916     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1998.tb00250.x     Document Type: Article
Times cited : (40)

References (22)
  • 1
    • 0007989123 scopus 로고
    • Current trends in the implantable cardioverter defibrillator
    • DP Zipes, J Jalife (eds.): Philadelphia, PA, W.B. Saunders
    • Mitrani RD, Klein LS, Rardon DP, et al. Current trends in the implantable cardioverter defibrillator. In DP Zipes, J Jalife (eds.): Cardiac electrophysiology. Philadelphia, PA, W.B. Saunders, 1995, pp. 1393-1403.
    • (1995) Cardiac Electrophysiology , pp. 1393-1403
    • Mitrani, R.D.1    Klein, L.S.2    Rardon, D.P.3
  • 2
    • 2642535562 scopus 로고    scopus 로고
    • Inappropriate ICD therapies: Incidence, causes, risk factors and prevention
    • E Adorno (ed.): Roma, Italy, Edizioni Luigi Pozzi
    • Weber M, Boecker D, Block M, et al. Inappropriate ICD therapies: Incidence, causes, risk factors and prevention. In E Adorno (ed.): Therapies for cardiac arrhythmias in 1996: Where are we going? Roma, Italy, Edizioni Luigi Pozzi, 1996, pp. 183-194.
    • (1996) Therapies for Cardiac Arrhythmias in 1996: Where Are We Going? , pp. 183-194
    • Weber, M.1    Boecker, D.2    Block, M.3
  • 3
    • 0026448128 scopus 로고
    • Electrocardiographically documented unnecessary spontaneous shocks in 241 patients with implantable cardioverter-defibrillators
    • Grimm W, Flores BF, Marchlinski FE. Electrocardiographically documented unnecessary spontaneous shocks in 241 patients with implantable cardioverter-defibrillators. PACE 1992; 15:1667-1673.
    • (1992) PACE , vol.15 , pp. 1667-1673
    • Grimm, W.1    Flores, B.F.2    Marchlinski, F.E.3
  • 4
    • 0022598366 scopus 로고
    • The automatic implantable cardioverter-defibrillator: Evaluating suspected inappropriate shocks
    • Chapman PD, Troup P. The automatic implantable cardioverter-defibrillator: Evaluating suspected inappropriate shocks. J Am Coll Cardiol 1986; 7:1075-1078.
    • (1986) J Am Coll Cardiol , vol.7 , pp. 1075-1078
    • Chapman, P.D.1    Troup, P.2
  • 5
    • 0007895384 scopus 로고    scopus 로고
    • New algorithms for discrimination between supraventricular and ventricular tachyarrhythmias in patients with implantable cardioverter defibrillator
    • Neuzner J, Schlepper M. New algorithms for discrimination between supraventricular and ventricular tachyarrhythmias in patients with implantable cardioverter defibrillator. Herzschr Elektrophys 1997; 8(Suppl 1):53-61.
    • (1997) Herzschr Elektrophys , vol.8 , Issue.1 SUPPL. , pp. 53-61
    • Neuzner, J.1    Schlepper, M.2
  • 6
    • 0023533369 scopus 로고
    • Onset and stability for ventricular tachyarrhythmia detection in an implantable cardioverter-defibrillator
    • New York, IEEE Press
    • Olson WH, Bardy GH, Mehra R, et al. Onset and stability for ventricular tachyarrhythmia detection in an implantable cardioverter-defibrillator. In Computers in Cardiology, New York, IEEE Press, 1987, pp.167-170.
    • (1987) Computers in Cardiology , pp. 167-170
    • Olson, W.H.1    Bardy, G.H.2    Mehra, R.3
  • 7
    • 0029620281 scopus 로고
    • Stability: An ICD detection criterion for discriminating atrial fibrillation from ventricular tachycardia
    • Higgins SL, Lee RS, Kramer RL. Stability: An ICD detection criterion for discriminating atrial fibrillation from ventricular tachycardia. J Cardiovasc Electrophysiol 1995; 6:1081-1088.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 1081-1088
    • Higgins, S.L.1    Lee, R.S.2    Kramer, R.L.3
  • 8
    • 0028941056 scopus 로고
    • Programmable VT detection enhancements in implantable cardioverter defibrillator therapy
    • Neuzner J, Pitschner HF, Schlepper M. Programmable VT detection enhancements in implantable cardioverter defibrillator therapy. PACE 1995; 18:539-547.
    • (1995) PACE , vol.18 , pp. 539-547
    • Neuzner, J.1    Pitschner, H.F.2    Schlepper, M.3
  • 9
    • 4243693189 scopus 로고    scopus 로고
    • Prospective evaluation of new and old criteria to discriminate between supraventricular and ventricular tachycardia in the Medtronic 7218C implantable defibrillator
    • Barold HS, Newby KH, Tomassoni G, et al. Prospective evaluation of new and old criteria to discriminate between supraventricular and ventricular tachycardia in the Medtronic 7218C implantable defibrillator. (abstract) Circulation 1996; 94(Suppl):3320.
    • (1996) Circulation , vol.94 , Issue.SUPPL. , pp. 3320
    • Barold, H.S.1    Newby, K.H.2    Tomassoni, G.3
  • 10
    • 4243447215 scopus 로고    scopus 로고
    • Worldwide experience with the electrogram width feature for improved detection in an implantable pacer-cardioverter-defibrillator
    • Brachmann J, Swerdlow CD, Mitchell BL, et al. for the Worldwide 7218 ICD investigators. Worldwide experience with the electrogram width feature for improved detection in an implantable pacer-cardioverter-defibrillator. (abstract) J Am Coll Cardiol 1997; 28(Suppl):115A.
    • (1997) J Am Coll Cardiol , vol.28 , Issue.SUPPL.
    • Brachmann, J.1    Swerdlow, C.D.2    Mitchell, B.L.3
  • 11
    • 0002872876 scopus 로고    scopus 로고
    • Intracardiac electrogram width measurement for improved tachycardia discrimination: Initial results of a new implantable cardioverter-defibrillator
    • Brachmann J, Seidl K, Hauer B, et al. Intracardiac electrogram width measurement for improved tachycardia discrimination: Initial results of a new implantable cardioverter-defibrillator. (abstract) J Am Coll Cardiol 1996; 27(Suppl):96A.
    • (1996) J Am Coll Cardiol , vol.27 , Issue.SUPPL.
    • Brachmann, J.1    Seidl, K.2    Hauer, B.3
  • 12
    • 0001829436 scopus 로고
    • Autonomic modulation of cardiac arrhythmias
    • DP Zipes, J Jalife (eds.): Philadelphia, PA, W.B. Saunders
    • Zipes DP. Autonomic modulation of cardiac arrhythmias. In DP Zipes, J Jalife (eds.): Cardiac Electrophysiology. Philadelphia, PA, W.B. Saunders, 1995, pp. 441-453.
    • (1995) Cardiac Electrophysiology , pp. 441-453
    • Zipes, D.P.1
  • 13
    • 4243406932 scopus 로고
    • Arryhthmogenic effects of antiarrhythmic drugs
    • DP Zipes, J Jalife (eds.): Philadelphia, PA, W.B. Saunders
    • Patterson E, Szabo B, Scherlag BJ, et al. Arryhthmogenic effects of antiarrhythmic drugs. In DP Zipes, J Jalife (eds.): Cardiac Electrophysiology. Philadelphia, PA, W.B. Saunders, 1995, pp. 496-511.
    • (1995) Cardiac Electrophysiology , pp. 496-511
    • Patterson, E.1    Szabo, B.2    Scherlag, B.J.3
  • 14
    • 0025739939 scopus 로고
    • NASPE Policy Statement: Implantable cardioverter defibrillators in cardiovascular practice: Report of the policy conference of the North American Society of Pacing and Electrophysiology
    • Lehmann MH, Saksena S. NASPE Policy Statement: Implantable cardioverter defibrillators in cardiovascular practice: Report of the policy conference of the North American Society of Pacing and Electrophysiology. PACE 1991; 14:969-979.
    • (1991) PACE , vol.14 , pp. 969-979
    • Lehmann, M.H.1    Saksena, S.2
  • 15
    • 0002364183 scopus 로고
    • Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices
    • Dreifuc LS, Fisch C, Griffin JC, et al. Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices. J Am Coll Cardiol 1991; 18: 1-13.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1-13
    • Dreifuc, L.S.1    Fisch, C.2    Griffin, J.C.3
  • 16
    • 0028324461 scopus 로고
    • Significance of supraventricular tachyarrhythmias in patients with implantable pacing cardioverter defibrillators
    • Schmitt C, Montero M, Melichercik J. Significance of supraventricular tachyarrhythmias in patients with implantable pacing cardioverter defibrillators. PACE 1994; 17:295-302.
    • (1994) PACE , vol.17 , pp. 295-302
    • Schmitt, C.1    Montero, M.2    Melichercik, J.3
  • 17
    • 0029126467 scopus 로고
    • The proarrhythmic potential of implantable cardioverter-defibillators
    • Pinski SL, Fahy GJ. The proarrhythmic potential of implantable cardioverter-defibillators. Circulation 1995; 92:1651-1664.
    • (1995) Circulation , vol.92 , pp. 1651-1664
    • Pinski, S.L.1    Fahy, G.J.2
  • 18
    • 0025772333 scopus 로고
    • Implantable cardioverter defibrillator proarrhythmia: Case report and review of the literature
    • Cohen TJ, Chien WW, Lurie KG, et al. Implantable cardioverter defibrillator proarrhythmia: Case report and review of the literature. PACE 1991; 14:1326-1329.
    • (1991) PACE , vol.14 , pp. 1326-1329
    • Cohen, T.J.1    Chien, W.W.2    Lurie, K.G.3
  • 19
    • 0030581450 scopus 로고    scopus 로고
    • Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy
    • Schaumann A, von zur Mühlen F, Gonska BD, et al. Enhanced detection criteria in implantable cardioverter-defibrillators to avoid inappropriate therapy. AmJ Cardiol 1996; 78(Suppl 5A):42-50.
    • (1996) AmJ Cardiol , vol.78 , Issue.SUPPL. 5A , pp. 42-50
    • Schaumann, A.1    Von Zur Mühlen, F.2    Gonska, B.D.3
  • 20
    • 0027989416 scopus 로고
    • The value of rate regularity and multiplicity measures to detect ventricular tachycardia in the presence of atrial fibrillation or flutter
    • Chiang CM, Jenkins JM, DiCarlo LA. The value of rate regularity and multiplicity measures to detect ventricular tachycardia in the presence of atrial fibrillation or flutter. PACE 1994; 17:1503-1508.
    • (1994) PACE , vol.17 , pp. 1503-1508
    • Chiang, C.M.1    Jenkins, J.M.2    DiCarlo, L.A.3
  • 21
    • 0028099709 scopus 로고
    • Differentiation of sinus tachycardia from ventricular tachycardia with 1:1 ventriculoatrial conduction in dual chamber implantable cardioverter defibrillators: Feasibility of a criterion based on the atrioventricular interval
    • LeCarpentier GL, Baga JJ, Yang H, et al. Differentiation of sinus tachycardia from ventricular tachycardia with 1:1 ventriculoatrial conduction in dual chamber implantable cardioverter defibrillators: Feasibility of a criterion based on the atrioventricular interval. PACE 1994; 17:1818-1831.
    • (1994) PACE , vol.17 , pp. 1818-1831
    • LeCarpentier, G.L.1    Baga, J.J.2    Yang, H.3
  • 22
    • 0026169317 scopus 로고
    • A comparison of four new time-domain techniques for discriminating monomorphic ventricular tachycardia from sinus rhythm using ventricular waveform morphology
    • Throne RD, Jenkins JM, DiCarlo LA. A comparison of four new time-domain techniques for discriminating monomorphic ventricular tachycardia from sinus rhythm using ventricular waveform morphology. IEEE Trans Biomed Eng 1991; 38: 561-570.
    • (1991) IEEE Trans Biomed Eng , vol.38 , pp. 561-570
    • Throne, R.D.1    Jenkins, J.M.2    DiCarlo, L.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.