1
-
-
0024460147
-
Correction of distortions due to the pulsed magnetic field gradient-induced shift in B0 field by postprocessing
-
P. Jehenson, A. Syrota, Correction of distortions due to the pulsed magnetic field gradient-induced shift in B0 field by postprocessing, Magn. Reson. Med. 12 (1989) 253-256.
-
(1989)
Magn. Reson. Med.
, vol.12
, pp. 253-256
-
-
Jehenson, P.1
Syrota, A.2
-
2
-
-
0032012581
-
Localized eddy current compensation using quantitative field mapping
-
M. Terpstra, P.M. Andersen, R. Gruetter, Localized eddy current compensation using quantitative field mapping, J. Magn. Reson. 131 (1998) 139-143.
-
(1998)
J. Magn. Reson.
, vol.131
, pp. 139-143
-
-
Terpstra, M.1
Andersen, P.M.2
Gruetter, R.3
-
4
-
-
44949277996
-
A PFG NMR experiment for accurate diffusion and flow studies in the presence of eddy currents
-
S.J. Gibbs, C.S. Johnson, A PFG NMR experiment for accurate diffusion and flow studies in the presence of eddy currents, J. Magn. Reson. 93 (1991) 395-402.
-
(1991)
J. Magn. Reson.
, vol.93
, pp. 395-402
-
-
Gibbs, S.J.1
Johnson, C.S.2
-
5
-
-
0031978367
-
Characterization of and correction for eddy current artifacts in echo planar diffusion imaging
-
P. Jezzard, A.S. Barnett, C. Pierpaoli, Characterization of and correction for eddy current artifacts in echo planar diffusion imaging, Magn. Reson. Med. 39 (1998) 801-812.
-
(1998)
Magn. Reson. Med.
, vol.39
, pp. 801-812
-
-
Jezzard, P.1
Barnett, A.S.2
Pierpaoli, C.3
-
6
-
-
0030726221
-
Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients
-
A.L. Alexander, J.S. Tsuruda, D.L. Parker, Elimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients, Magn. Reson. Med. 38 (1997) 1016-1021.
-
(1997)
Magn. Reson. Med.
, vol.38
, pp. 1016-1021
-
-
Alexander, A.L.1
Tsuruda, J.S.2
Parker, D.L.3
-
7
-
-
62649150156
-
Eddy-current compensated diffusion weighting with a single refocusing RF pulse
-
J. Finsterbusch, Eddy-current compensated diffusion weighting with a single refocusing RF pulse, Magn. Reson. Med. 61 (2009) 748-754.
-
(2009)
Magn. Reson. Med.
, vol.61
, pp. 748-754
-
-
Finsterbusch, J.1
-
8
-
-
0037229177
-
Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo
-
T. Reese, O. Heid, R. Weisskoff, V. Wedeen, Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo, Magn. Reson. Med. 49 (2003) 177-182.
-
(2003)
Magn. Reson. Med.
, vol.49
, pp. 177-182
-
-
Reese, T.1
Heid, O.2
Weisskoff, R.3
Wedeen, V.4
-
9
-
-
0026622949
-
Intensity artifacts in MRI caused by gradient switching in an animal-size NMR magnet
-
D.G. Hughes, S. Robertson, P.S. Allen, Intensity artifacts in MRI caused by gradient switching in an animal-size NMR magnet, Magn. Reson. Med. 25 (1992) 167-179.
-
(1992)
Magn. Reson. Med.
, vol.25
, pp. 167-179
-
-
Hughes, D.G.1
Robertson, S.2
Allen, P.S.3
-
10
-
-
0000389382
-
Active magnetic screening of gradient coils in NMR imaging
-
P. Mansfield, B. Chapman, Active magnetic screening of gradient coils in NMR imaging, J. Magn. Reson. 66 (1986) 573-576.
-
(1986)
J. Magn. Reson.
, vol.66
, pp. 573-576
-
-
Mansfield, P.1
Chapman, B.2
-
11
-
-
84865761393
-
Magnetic resonance imaging systems
-
MIT, US Patent #USA 4,733,189
-
W.F.B. Punchard, R.D. Pillsbury, Magnetic Resonance Imaging Systems, MIT, 1988. US Patent #USA 4,733, 189.
-
(1988)
-
-
Punchard, W.F.B.1
Pillsbury, R.D.2
-
12
-
-
0006567049
-
Self-shielded gradient coils for nuclear magnetic resonance imaging, general electric, US
-
US Patent #4,737,716
-
P.B. Roemer, J.S. Hickey, Self-Shielded Gradient Coils for Nuclear Magnetic Resonance Imaging, General Electric, US, 1988. US Patent #4, 737, 716.
-
(1988)
-
-
Roemer, P.B.1
Hickey, J.S.2
-
13
-
-
0027462082
-
A simple method of measuring gradient induced eddy currents to set compensation networks
-
R.E. Wysong, I.J. Lowe, A simple method of measuring gradient induced eddy currents to set compensation networks, Magn. Reson. Med. 29 (1993) 119- 121.
-
(1993)
Magn. Reson. Med.
, vol.29
, pp. 119-121
-
-
Wysong, R.E.1
Lowe, I.J.2
-
14
-
-
0001426032
-
Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems
-
P. Jehenson, M. Westphal, N. Schuff, Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems, J. Magn. Reson. 90 (1990) 264-278.
-
(1990)
J. Magn. Reson.
, vol.90
, pp. 264-278
-
-
Jehenson, P.1
Westphal, M.2
Schuff, N.3
-
15
-
-
0027961623
-
Quantitative characterization of the eddy current fields in a 40-cm bore superconducting magnet
-
Q. Liu, D.G. Hughes, P.S. Allen, Quantitative characterization of the eddy current fields in a 40-cm bore superconducting magnet, Magn. Reson. Med. 31 (1994) 73-76.
-
(1994)
Magn. Reson. Med.
, vol.31
, pp. 73-76
-
-
Liu, Q.1
Hughes, D.G.2
Allen, P.S.3
-
16
-
-
76649092326
-
Eddy current effects on a clinical 7 T-68 cm bore scanner
-
N. Kickler, W. van der Zwaag, R. Mekle, T. Kober, J.P. Marques, G. Krueger, R. Gruetter, Eddy current effects on a clinical 7 T-68 cm bore scanner, Magn. Reson. Mater. Phys. 23 (2010) 39-43.
-
(2010)
Magn. Reson. Mater. Phys.
, vol.23
, pp. 39-43
-
-
Kickler, N.1
Zwaag Der W.Van2
Mekle, R.3
Kober, T.4
Marques, J.P.5
Krueger, G.6
Gruetter, R.7
-
17
-
-
44949288378
-
Optimization of eddy-current compensation
-
J.J. van Vaals, A.H. Bergman, Optimization of eddy-current compensation, J. Magn. Reson. 90 (1990) 52-70.
-
(1990)
J. Magn. Reson.
, vol.90
, pp. 52-70
-
-
Van Vaals, J.J.1
Bergman, A.H.2
-
18
-
-
0023622508
-
Reduction of pulsed gradient settling time in the superconducting magnet of a magnetic resonance instrument
-
D.J. Jensen, W.W. Brey, J.L. Delayre, P.A. Narayana, Reduction of pulsed gradient settling time in the superconducting magnet of a magnetic resonance instrument, Med. Phys. 14 (1987) 859-862.
-
(1987)
Med. Phys.
, vol.14
, pp. 859-862
-
-
Jensen, D.J.1
Brey, W.W.2
Delayre, J.L.3
Narayana, P.A.4
-
19
-
-
0026717044
-
Analysis of the temporal and spatial dependence of the eddy current fields in a 40-cm bore magnet
-
S. Robertson, D.G. Hughes, Q. Liu, P.S. Allen, Analysis of the temporal and spatial dependence of the eddy current fields in a 40-cm bore magnet, Magn. Reson. Med. 25 (1992) 158-166.
-
(1992)
Magn. Reson. Med.
, vol.25
, pp. 158-166
-
-
Robertson, S.1
Hughes, D.G.2
Liu, Q.3
Allen, P.S.4
-
20
-
-
0025832121
-
Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: Optimization of corrections and quantitative characterization of magnet/gradient systems
-
C. Boesch, R. Gruetter, E. Martin, Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: optimization of corrections and quantitative characterization of magnet/gradient systems, Magn. Reson. Med. 20 (1991) 268-284.
-
(1991)
Magn. Reson. Med.
, vol.20
, pp. 268-284
-
-
Boesch, C.1
Gruetter, R.2
Martin, E.3
-
21
-
-
0033786208
-
Gradient preemphasis calibration in diffusion-weighted echo-planar imaging
-
N. Papadakis, K. Martin, J. Pickard, L. Hall, T. Carpenter, C. Huang, Gradient preemphasis calibration in diffusion-weighted echo-planar imaging, Magn. Reson. Med. 44 (2000) 616-624.
-
(2000)
Magn. Reson. Med.
, vol.44
, pp. 616-624
-
-
Papadakis, N.1
Martin, K.2
Pickard, J.3
Hall, L.4
Carpenter, T.5
Huang, C.6
-
22
-
-
0010308581
-
Magnetic field mapping with an array of nuclear magnetic resonance probes
-
B. Hammer, Magnetic field mapping with an array of nuclear magnetic resonance probes, Rev. Sci. Instrum. 67 (1996) 2378-2380.
-
(1996)
Rev. Sci. Instrum.
, vol.67
, pp. 2378-2380
-
-
Hammer, B.1
-
23
-
-
46849121002
-
NMR probes for measuring magnetic fields and field dynamics in MR systems
-
N. De Zanche, C. Barmet, J.A. Nordmeyer-Massner, K.P. Pruessmann, NMR probes for measuring magnetic fields and field dynamics in MR systems, Magn. Reson. Med. 60 (2008) 176-186.
-
(2008)
Magn. Reson. Med.
, vol.60
, pp. 176-186
-
-
De Zanche, N.1
Barmet, C.2
Nordmeyer-Massner, J.A.3
Pruessmann, K.P.4
-
24
-
-
70350618470
-
Pure phase encode magnetic field gradient monitor
-
H. Han, R. MacGregor, B. Balcom, Pure phase encode magnetic field gradient monitor, J. Magn. Reson. 201 (2009) 212-217.
-
(2009)
J. Magn. Reson.
, vol.201
, pp. 212-217
-
-
Han, H.1
MacGregor, R.2
Balcom, B.3
-
25
-
-
78650101091
-
Direct measurement of magnetic field gradient waveforms
-
H. Han, A. Ouriadov, E. Fordham, B. Balcom, Direct measurement of magnetic field gradient waveforms, Concepts Magn. Reson. Part A 36 (2010) 349-360.
-
(2010)
Concepts Magn. Reson. Part A
, vol.36
, pp. 349-360
-
-
Han, H.1
Ouriadov, A.2
Fordham, E.3
Balcom, B.4
-
26
-
-
30744433867
-
How accurately can parameters from exponential models be estimated?, Concepts Magn Reson
-
G.L. Bretthorst, How accurately can parameters from exponential models be estimated?, Concepts Magn Reson. Part A 27A (2005) 73-83.
-
(2005)
Part A
, vol.27 A
, pp. 73-83
-
-
Bretthorst, G.L.1
-
27
-
-
30744464843
-
Exponential parameter estimation (in NMR) using Bayesian probability theory
-
G.L. Bretthorst, W.C. Hutton, J.R. Garbow, J.J.H. Ackerman, Exponential parameter estimation (in NMR) using Bayesian probability theory, Concepts Magn. Reson. Part A 27A (2005) 55-63.
-
(2005)
Concepts Magn. Reson. Part A
, vol.27 A
, pp. 55-63
-
-
Bretthorst, G.L.1
Hutton, W.C.2
Garbow, J.R.3
Ackerman, J.J.H.4
-
28
-
-
30744459864
-
Exponential model selection (in NMR) using Bayesian probability
-
G.L. Bretthorst, W.C. Hutton, J.R. Garbow, J.J.H. Ackerman, Exponential model selection (in NMR) using Bayesian probability, Concepts Magn. Reson. Part A 27A (2005) 64-72.
-
(2005)
Concepts Magn. Reson. Part A
, vol.27 A
, pp. 64-72
-
-
Bretthorst, G.L.1
Hutton, W.C.2
Garbow, J.R.3
Ackerman, J.J.H.4
-
29
-
-
0027973923
-
Theory of NMR signal behavior in magnetically inhomogeneous tissues: The static dephasing regime
-
D. Yablonskiy, E. Haacke, Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime, Magn. Reson. Med. 32 (1994) 749-763.
-
(1994)
Magn. Reson. Med.
, vol.32
, pp. 749-763
-
-
Yablonskiy, D.1
Haacke, E.2
-
30
-
-
84941965835
-
-
Elsevier Academic Press, Burlington, MA
-
M. Bernstein, K. King, X. Zhou, Handbook of MRI Pulse Sequences, Elsevier Academic Press, Burlington, MA, 2004.
-
(2004)
Handbook of MRI Pulse Sequences
-
-
Bernstein, M.1
King, K.2
Zhou, X.3
-
31
-
-
84889582115
-
NMR chemical shifts of common laboratory solvents as trace impurities
-
H.E. Gottlieb, V. Kotlyar, A. Nudelman, NMR chemical shifts of common laboratory solvents as trace impurities, J. Org. Chem. 62 (1997) 7512-7515.
-
(1997)
J. Org. Chem.
, vol.62
, pp. 7512-7515
-
-
Gottlieb, H.E.1
Kotlyar, V.2
Nudelman, A.3
-
32
-
-
85030489173
-
-
N.I.o.A.I.S.a.T. (Japan), National Institute of Advanced Industrial Science and Technology, Japan
-
N.I.o.A.I.S.a.T. (Japan), Database for Organic Compounds, National Institute of Advanced Industrial Science and Technology, Japan, 2010, 〈http://riodb01.ibase.aist.go.jp/sdbs/〉.
-
(2010)
Database for Organic Compounds
-
-
-
33
-
-
85030490696
-
-
G.L. Bretthorst, 2011, 〈http://bayesiananalysis.wustl.edu/index. html〉.
-
(2011)
-
-
Bretthorst, G.L.1
-
34
-
-
44949266852
-
Bayesian analysis. III. Applications to NMR signal detection, model selection, and parameter estimation
-
G.L. Bretthorst, Bayesian analysis. III. Applications to NMR signal detection, model selection, and parameter estimation, J. Magn. Reson. 88 (1990) 571- 595.
-
(1990)
J. Magn. Reson.
, vol.88
, pp. 571-595
-
-
Bretthorst, G.L.1
-
35
-
-
0007417080
-
Comparison of Fourier and Bayesian analysis of NMR signals. II. Examination of truncated free induction decay NMR data
-
J.J. Kotyk, N.G. Hoffman, W.C. Hutton, G.L. Bretthorst, J.J.H. Ackerman, Comparison of Fourier and Bayesian analysis of NMR signals. II. Examination of truncated free induction decay NMR data, J. Magn. Reson. Ser. A 116 (1995) 1-9.
-
(1995)
J. Magn. Reson. Ser.
, vol.A 116
, pp. 1-9
-
-
Kotyk, J.J.1
Hoffman, N.G.2
Hutton, W.C.3
Bretthorst, G.L.4
Ackerman, J.J.H.5
-
36
-
-
33750632039
-
Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition
-
V. Mlynárik, G. Gambarota, H. Frenkel, R. Gruetter, Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition, Magn. Reson. Med. 56 (2006) 965-970.
-
(2006)
Magn. Reson. Med.
, vol.56
, pp. 965-970
-
-
Mlynárik, V.1
Gambarota, G.2
Frenkel, H.3
Gruetter, R.4
-
37
-
-
43949151247
-
Self-compensating pulsed magnetic-field gradients for short recovery times
-
G. Wider, V. Dotsch, K. Wüthrich, Self-compensating pulsed magnetic-field gradients for short recovery times, J. Magn. Reson. Ser. A (1994) 255-258.
-
(1994)
J. Magn. Reson. Ser. A
, pp. 255-258
-
-
Wider, G.1
Dotsch, V.2
Wüthrich, K.3
|