메뉴 건너뛰기




Volumn 36 A, Issue 6, 2010, Pages 349-360

Direct measurement of magnetic field gradient waveforms

Author keywords

Centric scan SPRITE; Eddy currents; FID; Fourier transform; Gradient waveform; K space trajectory; Magnetization preparation; Multiple point; Pure phase encode

Indexed keywords


EID: 78650101091     PISSN: 15466086     EISSN: 15525023     Source Type: Journal    
DOI: 10.1002/cmr.a.20194     Document Type: Article
Times cited : (13)

References (35)
  • 1
    • 0000389382 scopus 로고
    • Active magnetic screening of gradient coils in NMR imaging
    • Mansfield P, Chapman B. 1986. Active magnetic screening of gradient coils in NMR imaging. J Magn Reson 66: 573-576.
    • (1986) J Magn Reson , vol.66 , pp. 573-576
    • Mansfield, P.1    Chapman, B.2
  • 2
    • 44949288378 scopus 로고
    • Optimization of eddy-current compensation
    • Van Vaals JJ, Bergman AH. 1990. Optimization of eddy-current compensation. J Magn Reson 90: 52-70.
    • (1990) J Magn Reson , vol.90 , pp. 52-70
    • Van Vaals, J.J.1    Bergman, A.H.2
  • 3
    • 18244365359 scopus 로고    scopus 로고
    • K-space correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging
    • Papadakis NG, Smponias T, Berwick J, and Mayhew JEW. 2005. K-space correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging. Magn Reson Med 53: 1103-1111.
    • (2005) Magn Reson Med , vol.53 , pp. 1103-1111
    • Papadakis, N.G.1    Smponias, T.2    Berwick, J.3    Mayhew, J.E.W.4
  • 4
    • 0037229177 scopus 로고    scopus 로고
    • Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo
    • Reese TG, Heid O, Weisskoff RM. 2003. Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Magn Reson Med 49: 177-182.
    • (2003) Magn Reson Med , vol.49 , pp. 177-182
    • Reese, T.G.1    Heid, O.2    Weisskoff, R.M.3
  • 5
    • 73149111748 scopus 로고    scopus 로고
    • Characterizing and correcting gradient errors in non-Cartesian imaging: are gradient errors linear time-invariant (LTI)?
    • Brodsky EK, Samsonov AA, Block WF. 2009. Characterizing and correcting gradient errors in non-Cartesian imaging: are gradient errors linear time-invariant (LTI)? Magn Reson Med 62: 1566-1476.
    • (2009) Magn Reson Med , vol.62 , pp. 1566-1476
    • Brodsky, E.K.1    Samsonov, A.A.2    Block, W.F.3
  • 6
    • 33745727900 scopus 로고    scopus 로고
    • Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging
    • Kim DH, Spielman DM. 2006. Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging. Magn Reson Med 56: 198-203.
    • (2006) Magn Reson Med , vol.56 , pp. 198-203
    • Kim, D.H.1    Spielman, D.M.2
  • 8
    • 36348942999 scopus 로고    scopus 로고
    • High-resolution time-resolved contrast-enhanced MR abdominal and pulmonary angiography using a Spiral-TRICKS sequence
    • Du J, Bydder M. 2007. High-resolution time-resolved contrast-enhanced MR abdominal and pulmonary angiography using a Spiral-TRICKS sequence. Magn Reson Med 58: 631-635.
    • (2007) Magn Reson Med , vol.58 , pp. 631-635
    • Du, J.1    Bydder, M.2
  • 9
    • 66149139300 scopus 로고    scopus 로고
    • Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging
    • Josan S, Pauly JM, Daniel BL, Pauly KB. 2009. Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging. Magn Reson Med 61: 1083-1089.
    • (2009) Magn Reson Med , vol.61 , pp. 1083-1089
    • Josan, S.1    Pauly, J.M.2    Daniel, B.L.3    Pauly, K.B.4
  • 10
    • 67749120067 scopus 로고    scopus 로고
    • Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients
    • Atkinson IC, Lu A, Thulborn KR. 2009. Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients. Magn Reson Med 62: 532-537.
    • (2009) Magn Reson Med , vol.62 , pp. 532-537
    • Atkinson, I.C.1    Lu, A.2    Thulborn, K.R.3
  • 11
    • 0027462082 scopus 로고
    • A simple method of measuring gradient induced eddy currents to set compensation networks
    • Wysong RE, Lowe IJ. 1993. A simple method of measuring gradient induced eddy currents to set compensation networks. Magn Reson Med 29: 119-121.
    • (1993) Magn Reson Med , vol.29 , pp. 119-121
    • Wysong, R.E.1    Lowe, I.J.2
  • 12
    • 0025832121 scopus 로고
    • Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: optimization of corrections and quantitative characterization of magnet/gradient systems
    • Boesch C, Gruetter R, Martin E. 1991. Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: optimization of corrections and quantitative characterization of magnet/gradient systems. Magn Reson Med 20: 268-284.
    • (1991) Magn Reson Med , vol.20 , pp. 268-284
    • Boesch, C.1    Gruetter, R.2    Martin, E.3
  • 14
    • 0036135290 scopus 로고    scopus 로고
    • Automatic gradient preemphasis: a 15 min journey to improved diffusion-weighted echo planar imaging
    • Schmithorst VJ, Dardzinski BJ. 2002. Automatic gradient preemphasis: a 15 min journey to improved diffusion-weighted echo planar imaging. Magn Reson Med 47: 208-212.
    • (2002) Magn Reson Med , vol.47 , pp. 208-212
    • Schmithorst, V.J.1    Dardzinski, B.J.2
  • 15
    • 0029121371 scopus 로고
    • Compensation of multi-dimensional selective excitation pulses using measured k-space trajectories
    • Takahashi A, Peters T. 1995. Compensation of multi-dimensional selective excitation pulses using measured k-space trajectories. Magn Reson Med 34: 446-456.
    • (1995) Magn Reson Med , vol.34 , pp. 446-456
    • Takahashi, A.1    Peters, T.2
  • 16
    • 0031895850 scopus 로고    scopus 로고
    • Gradient characterization using a Fourier-transform technique
    • Alley MT, Glover GH, Pelc NJ. 1998. Gradient characterization using a Fourier-transform technique. Magn Reson Med 39: 581-587.
    • (1998) Magn Reson Med , vol.39 , pp. 581-587
    • Alley, M.T.1    Glover, G.H.2    Pelc, N.J.3
  • 18
    • 0032059889 scopus 로고    scopus 로고
    • Simple correction method of k-space trajectory deviations in MRI
    • Duyn JH, Yang YH, Frank JA. 1998. Simple correction method of k-space trajectory deviations in MRI. J Magn Reson 132: 150-153.
    • (1998) J Magn Reson , vol.132 , pp. 150-153
    • Duyn, J.H.1    Yang, Y.H.2    Frank, J.A.3
  • 21
    • 44849095512 scopus 로고    scopus 로고
    • Robust, susceptibility-matched NMR probes for compensation of magnetic field imperfections in magnetic resonance imaging (MRI)
    • Sipila P, Lange D, Lechner S, Low W, Gross P, Baller M, Wachutka G, Wiesinger F. 2008. Robust, susceptibility-matched NMR probes for compensation of magnetic field imperfections in magnetic resonance imaging (MRI). Sensor Actuat A 145-146: 139-146.
    • (2008) Sensor Actuat A , vol.145-146 , pp. 139-146
    • Sipila, P.1    Lange, D.2    Lechner, S.3    Low, W.4    Gross, P.5    Baller, M.6    Wachutka, G.7    Wiesinger, F.8
  • 22
    • 0010775891 scopus 로고    scopus 로고
    • Single point imaging of gradient rise, stabilization, decay
    • Balcom BJ, Bogdan M, Armstrong RL. 1996. Single point imaging of gradient rise, stabilization, decay. J Magn Reson A 118: 122-125.
    • (1996) J Magn Reson A , vol.118 , pp. 122-125
    • Balcom, B.J.1    Bogdan, M.2    Armstrong, R.L.3
  • 24
    • 70350618470 scopus 로고    scopus 로고
    • Pure phase encode magnetic field gradient monitor
    • Han H, MacGregor R, Balcom BJ. 2009. Pure phase encode magnetic field gradient monitor. J Magn Reson 201: 212-217.
    • (2009) J Magn Reson , vol.201 , pp. 212-217
    • Han, H.1    MacGregor, R.2    Balcom, B.J.3
  • 25
    • 0030754566 scopus 로고    scopus 로고
    • A general method for measurement of the time integral of variant magnetic field gradients: application to 2D spiral imaging
    • Papadakis NG, Wilkinson AA, Carpenter TA. 1997. A general method for measurement of the time integral of variant magnetic field gradients: application to 2D spiral imaging. Magn Reson Imaing 15: 567-578.
    • (1997) Magn Reson Imaing , vol.15 , pp. 567-578
    • Papadakis, N.G.1    Wilkinson, A.A.2    Carpenter, T.A.3
  • 26
    • 0005211329 scopus 로고
    • Eddy current compensation by direct field modification and digital gradient modification
    • Majors PD, Blackley JL, Altobellie SA, Caprihan A, Fukushima E. 1990. Eddy current compensation by direct field modification and digital gradient modification. J Magn Reson 87: 548-553.
    • (1990) J Magn Reson , vol.87 , pp. 548-553
    • Majors, P.D.1    Blackley, J.L.2    Altobellie, S.A.3    Caprihan, A.4    Fukushima, E.5
  • 29
    • 33746312416 scopus 로고    scopus 로고
    • Centric-scan SPRITE magnetic resonance imaging with prepared magnetization
    • Khrapitchev AA, Newling B, Balcom BJ. 2006. Centric-scan SPRITE magnetic resonance imaging with prepared magnetization. J Magn Reson 181: 271-279.
    • (2006) J Magn Reson , vol.181 , pp. 271-279
    • Khrapitchev, A.A.1    Newling, B.2    Balcom, B.J.3
  • 30
    • 0032352438 scopus 로고    scopus 로고
    • Pulsed-Field gradient nuclear magnetic resonance as a Tool for studying translational diffusion: part II. experimental aspects
    • Price WS. 1998. Pulsed-Field gradient nuclear magnetic resonance as a Tool for studying translational diffusion: part II. experimental aspects. Concept Magn Reson 10: 197-237.
    • (1998) Concept Magn Reson , vol.10 , pp. 197-237
    • Price, W.S.1
  • 31
    • 0027369131 scopus 로고
    • Gradient coil design-a review of methods
    • Turner R. 1993. Gradient coil design-a review of methods. Magn Reson Imag 11: 903-920.
    • (1993) Magn Reson Imag , vol.11 , pp. 903-920
    • Turner, R.1
  • 32
    • 0022001875 scopus 로고
    • Volumetric NMR imaging with time-varying gradients
    • Macovski A. 1985. Volumetric NMR imaging with time-varying gradients. Magn Reson Med 2: 29-40.
    • (1985) Magn Reson Med , vol.2 , pp. 29-40
    • Macovski, A.1
  • 33
    • 0022187595 scopus 로고
    • A fast sinc function gridding algorithm for Fourier inversion in compute tomography
    • O'Sulllivan J. 1985. A fast sinc function gridding algorithm for Fourier inversion in compute tomography. IEEEs Trans Med Imag 4: 200-207.
    • (1985) IEEEs Trans Med Imag , vol.4 , pp. 200-207
    • O'Sulllivan, J.1
  • 34
    • 0019732771 scopus 로고
    • An investigation of computerized tomography by direct Fourier inversion and optimum interpolation
    • Stark H, Woods JW, Paul I, Hingorani R. 1981. An investigation of computerized tomography by direct Fourier inversion and optimum interpolation. IEEE Trans Biomed Eng 28: 496-505.
    • (1981) IEEE Trans Biomed Eng , vol.28 , pp. 496-505
    • Stark, H.1    Woods, J.W.2    Paul, I.3    Hingorani, R.4
  • 35
    • 67349158685 scopus 로고    scopus 로고
    • Spin echo SPI methods for quantitative analysis of fluids in porous media
    • Lin L, Han H, Balcom BJ. 2009. Spin echo SPI methods for quantitative analysis of fluids in porous media. J Magn Reson 198: 252-260.
    • (2009) J Magn Reson , vol.198 , pp. 252-260
    • Lin, L.1    Han, H.2    Balcom, B.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.