-
1
-
-
0000389382
-
Active magnetic screening of gradient coils in NMR imaging
-
Mansfield P, Chapman B. 1986. Active magnetic screening of gradient coils in NMR imaging. J Magn Reson 66: 573-576.
-
(1986)
J Magn Reson
, vol.66
, pp. 573-576
-
-
Mansfield, P.1
Chapman, B.2
-
2
-
-
44949288378
-
Optimization of eddy-current compensation
-
Van Vaals JJ, Bergman AH. 1990. Optimization of eddy-current compensation. J Magn Reson 90: 52-70.
-
(1990)
J Magn Reson
, vol.90
, pp. 52-70
-
-
Van Vaals, J.J.1
Bergman, A.H.2
-
3
-
-
18244365359
-
K-space correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging
-
Papadakis NG, Smponias T, Berwick J, and Mayhew JEW. 2005. K-space correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging. Magn Reson Med 53: 1103-1111.
-
(2005)
Magn Reson Med
, vol.53
, pp. 1103-1111
-
-
Papadakis, N.G.1
Smponias, T.2
Berwick, J.3
Mayhew, J.E.W.4
-
4
-
-
0037229177
-
Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo
-
Reese TG, Heid O, Weisskoff RM. 2003. Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Magn Reson Med 49: 177-182.
-
(2003)
Magn Reson Med
, vol.49
, pp. 177-182
-
-
Reese, T.G.1
Heid, O.2
Weisskoff, R.M.3
-
5
-
-
73149111748
-
Characterizing and correcting gradient errors in non-Cartesian imaging: are gradient errors linear time-invariant (LTI)?
-
Brodsky EK, Samsonov AA, Block WF. 2009. Characterizing and correcting gradient errors in non-Cartesian imaging: are gradient errors linear time-invariant (LTI)? Magn Reson Med 62: 1566-1476.
-
(2009)
Magn Reson Med
, vol.62
, pp. 1566-1476
-
-
Brodsky, E.K.1
Samsonov, A.A.2
Block, W.F.3
-
6
-
-
33745727900
-
Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging
-
Kim DH, Spielman DM. 2006. Reducing gradient imperfections for spiral magnetic resonance spectroscopic imaging. Magn Reson Med 56: 198-203.
-
(2006)
Magn Reson Med
, vol.56
, pp. 198-203
-
-
Kim, D.H.1
Spielman, D.M.2
-
7
-
-
57149120524
-
Improved 3D phase contrast MRI with off-resonance corrected dual echo VIPR
-
Johnson KM, Lum DP, Turski PA, Block WF, Mistretta CA, and Wieben O. 2008. Improved 3D phase contrast MRI with off-resonance corrected dual echo VIPR. Magn Reson Med 60: 1329-1336.
-
(2008)
Magn Reson Med
, vol.60
, pp. 1329-1336
-
-
Johnson, K.M.1
Lum, D.P.2
Turski, P.A.3
Block, W.F.4
Mistretta, C.A.5
Wieben, O.6
-
8
-
-
36348942999
-
High-resolution time-resolved contrast-enhanced MR abdominal and pulmonary angiography using a Spiral-TRICKS sequence
-
Du J, Bydder M. 2007. High-resolution time-resolved contrast-enhanced MR abdominal and pulmonary angiography using a Spiral-TRICKS sequence. Magn Reson Med 58: 631-635.
-
(2007)
Magn Reson Med
, vol.58
, pp. 631-635
-
-
Du, J.1
Bydder, M.2
-
9
-
-
66149139300
-
Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging
-
Josan S, Pauly JM, Daniel BL, Pauly KB. 2009. Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging. Magn Reson Med 61: 1083-1089.
-
(2009)
Magn Reson Med
, vol.61
, pp. 1083-1089
-
-
Josan, S.1
Pauly, J.M.2
Daniel, B.L.3
Pauly, K.B.4
-
10
-
-
67749120067
-
Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients
-
Atkinson IC, Lu A, Thulborn KR. 2009. Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients. Magn Reson Med 62: 532-537.
-
(2009)
Magn Reson Med
, vol.62
, pp. 532-537
-
-
Atkinson, I.C.1
Lu, A.2
Thulborn, K.R.3
-
11
-
-
0027462082
-
A simple method of measuring gradient induced eddy currents to set compensation networks
-
Wysong RE, Lowe IJ. 1993. A simple method of measuring gradient induced eddy currents to set compensation networks. Magn Reson Med 29: 119-121.
-
(1993)
Magn Reson Med
, vol.29
, pp. 119-121
-
-
Wysong, R.E.1
Lowe, I.J.2
-
12
-
-
0025832121
-
Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: optimization of corrections and quantitative characterization of magnet/gradient systems
-
Boesch C, Gruetter R, Martin E. 1991. Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: optimization of corrections and quantitative characterization of magnet/gradient systems. Magn Reson Med 20: 268-284.
-
(1991)
Magn Reson Med
, vol.20
, pp. 268-284
-
-
Boesch, C.1
Gruetter, R.2
Martin, E.3
-
13
-
-
0031847927
-
A programmable pre-emphasis system
-
Gach HM, Lowe IJ, Madio DP, Caprihan A, Altobelli SA, Kuethe DO, Fukushima E. 1998. A programmable pre-emphasis system. Magn Reson Med 40: 427-431.
-
(1998)
Magn Reson Med
, vol.40
, pp. 427-431
-
-
Gach, H.M.1
Lowe, I.J.2
Madio, D.P.3
Caprihan, A.4
Altobelli, S.A.5
Kuethe, D.O.6
Fukushima, E.7
-
14
-
-
0036135290
-
Automatic gradient preemphasis: a 15 min journey to improved diffusion-weighted echo planar imaging
-
Schmithorst VJ, Dardzinski BJ. 2002. Automatic gradient preemphasis: a 15 min journey to improved diffusion-weighted echo planar imaging. Magn Reson Med 47: 208-212.
-
(2002)
Magn Reson Med
, vol.47
, pp. 208-212
-
-
Schmithorst, V.J.1
Dardzinski, B.J.2
-
15
-
-
0029121371
-
Compensation of multi-dimensional selective excitation pulses using measured k-space trajectories
-
Takahashi A, Peters T. 1995. Compensation of multi-dimensional selective excitation pulses using measured k-space trajectories. Magn Reson Med 34: 446-456.
-
(1995)
Magn Reson Med
, vol.34
, pp. 446-456
-
-
Takahashi, A.1
Peters, T.2
-
16
-
-
0031895850
-
Gradient characterization using a Fourier-transform technique
-
Alley MT, Glover GH, Pelc NJ. 1998. Gradient characterization using a Fourier-transform technique. Magn Reson Med 39: 581-587.
-
(1998)
Magn Reson Med
, vol.39
, pp. 581-587
-
-
Alley, M.T.1
Glover, G.H.2
Pelc, N.J.3
-
17
-
-
0030930221
-
A method to measure arbitrary k-space trajectories for rapid MR imaging
-
Mason G, Harshbarger T, Hetherington H, Zhang Y, Pohost G, Twieg D. 1997. A method to measure arbitrary k-space trajectories for rapid MR imaging. Magn Reson Med 38: 492-496.
-
(1997)
Magn Reson Med
, vol.38
, pp. 492-496
-
-
Mason, G.1
Harshbarger, T.2
Hetherington, H.3
Zhang, Y.4
Pohost, G.5
Twieg, D.6
-
18
-
-
0032059889
-
Simple correction method of k-space trajectory deviations in MRI
-
Duyn JH, Yang YH, Frank JA. 1998. Simple correction method of k-space trajectory deviations in MRI. J Magn Reson 132: 150-153.
-
(1998)
J Magn Reson
, vol.132
, pp. 150-153
-
-
Duyn, J.H.1
Yang, Y.H.2
Frank, J.A.3
-
19
-
-
0031837476
-
A novel k-space trajectory measurement technique
-
Zhang YT, Hetherington HP, Stokely EM, Mason GM, Twieg DB. 1998. A novel k-space trajectory measurement technique. Magn Reson Med 39: 999-1004.
-
(1998)
Magn Reson Med
, vol.39
, pp. 999-1004
-
-
Zhang, Y.T.1
Hetherington, H.P.2
Stokely, E.M.3
Mason, G.M.4
Twieg, D.B.5
-
21
-
-
44849095512
-
Robust, susceptibility-matched NMR probes for compensation of magnetic field imperfections in magnetic resonance imaging (MRI)
-
Sipila P, Lange D, Lechner S, Low W, Gross P, Baller M, Wachutka G, Wiesinger F. 2008. Robust, susceptibility-matched NMR probes for compensation of magnetic field imperfections in magnetic resonance imaging (MRI). Sensor Actuat A 145-146: 139-146.
-
(2008)
Sensor Actuat A
, vol.145-146
, pp. 139-146
-
-
Sipila, P.1
Lange, D.2
Lechner, S.3
Low, W.4
Gross, P.5
Baller, M.6
Wachutka, G.7
Wiesinger, F.8
-
22
-
-
0010775891
-
Single point imaging of gradient rise, stabilization, decay
-
Balcom BJ, Bogdan M, Armstrong RL. 1996. Single point imaging of gradient rise, stabilization, decay. J Magn Reson A 118: 122-125.
-
(1996)
J Magn Reson A
, vol.118
, pp. 122-125
-
-
Balcom, B.J.1
Bogdan, M.2
Armstrong, R.L.3
-
23
-
-
0041492769
-
Single point measurements of magnetic field gradient waveform
-
Goodyear DJ, Shea M, Beyea SD, Shah NJ, Balcom BJ. 2003. Single point measurements of magnetic field gradient waveform. J Magn Reson 163: 1-7.
-
(2003)
J Magn Reson
, vol.163
, pp. 1-7
-
-
Goodyear, D.J.1
Shea, M.2
Beyea, S.D.3
Shah, N.J.4
Balcom, B.J.5
-
24
-
-
70350618470
-
Pure phase encode magnetic field gradient monitor
-
Han H, MacGregor R, Balcom BJ. 2009. Pure phase encode magnetic field gradient monitor. J Magn Reson 201: 212-217.
-
(2009)
J Magn Reson
, vol.201
, pp. 212-217
-
-
Han, H.1
MacGregor, R.2
Balcom, B.J.3
-
25
-
-
0030754566
-
A general method for measurement of the time integral of variant magnetic field gradients: application to 2D spiral imaging
-
Papadakis NG, Wilkinson AA, Carpenter TA. 1997. A general method for measurement of the time integral of variant magnetic field gradients: application to 2D spiral imaging. Magn Reson Imaing 15: 567-578.
-
(1997)
Magn Reson Imaing
, vol.15
, pp. 567-578
-
-
Papadakis, N.G.1
Wilkinson, A.A.2
Carpenter, T.A.3
-
26
-
-
0005211329
-
Eddy current compensation by direct field modification and digital gradient modification
-
Majors PD, Blackley JL, Altobellie SA, Caprihan A, Fukushima E. 1990. Eddy current compensation by direct field modification and digital gradient modification. J Magn Reson 87: 548-553.
-
(1990)
J Magn Reson
, vol.87
, pp. 548-553
-
-
Majors, P.D.1
Blackley, J.L.2
Altobellie, S.A.3
Caprihan, A.4
Fukushima, E.5
-
28
-
-
28844471981
-
Quantitative density profiling with pure phase encoding and a dedicated 1D gradient
-
Deka K, MacMillan MB, Ouriadov AV, Mastikhin IV, Young JJ, Glover PM, Ziegler GR, Balcom BJ. 2006. Quantitative density profiling with pure phase encoding and a dedicated 1D gradient. J Magn Reson 178: 25-32.
-
(2006)
J Magn Reson
, vol.178
, pp. 25-32
-
-
Deka, K.1
MacMillan, M.B.2
Ouriadov, A.V.3
Mastikhin, I.V.4
Young, J.J.5
Glover, P.M.6
Ziegler, G.R.7
Balcom, B.J.8
-
29
-
-
33746312416
-
Centric-scan SPRITE magnetic resonance imaging with prepared magnetization
-
Khrapitchev AA, Newling B, Balcom BJ. 2006. Centric-scan SPRITE magnetic resonance imaging with prepared magnetization. J Magn Reson 181: 271-279.
-
(2006)
J Magn Reson
, vol.181
, pp. 271-279
-
-
Khrapitchev, A.A.1
Newling, B.2
Balcom, B.J.3
-
30
-
-
0032352438
-
Pulsed-Field gradient nuclear magnetic resonance as a Tool for studying translational diffusion: part II. experimental aspects
-
Price WS. 1998. Pulsed-Field gradient nuclear magnetic resonance as a Tool for studying translational diffusion: part II. experimental aspects. Concept Magn Reson 10: 197-237.
-
(1998)
Concept Magn Reson
, vol.10
, pp. 197-237
-
-
Price, W.S.1
-
31
-
-
0027369131
-
Gradient coil design-a review of methods
-
Turner R. 1993. Gradient coil design-a review of methods. Magn Reson Imag 11: 903-920.
-
(1993)
Magn Reson Imag
, vol.11
, pp. 903-920
-
-
Turner, R.1
-
32
-
-
0022001875
-
Volumetric NMR imaging with time-varying gradients
-
Macovski A. 1985. Volumetric NMR imaging with time-varying gradients. Magn Reson Med 2: 29-40.
-
(1985)
Magn Reson Med
, vol.2
, pp. 29-40
-
-
Macovski, A.1
-
33
-
-
0022187595
-
A fast sinc function gridding algorithm for Fourier inversion in compute tomography
-
O'Sulllivan J. 1985. A fast sinc function gridding algorithm for Fourier inversion in compute tomography. IEEEs Trans Med Imag 4: 200-207.
-
(1985)
IEEEs Trans Med Imag
, vol.4
, pp. 200-207
-
-
O'Sulllivan, J.1
-
34
-
-
0019732771
-
An investigation of computerized tomography by direct Fourier inversion and optimum interpolation
-
Stark H, Woods JW, Paul I, Hingorani R. 1981. An investigation of computerized tomography by direct Fourier inversion and optimum interpolation. IEEE Trans Biomed Eng 28: 496-505.
-
(1981)
IEEE Trans Biomed Eng
, vol.28
, pp. 496-505
-
-
Stark, H.1
Woods, J.W.2
Paul, I.3
Hingorani, R.4
-
35
-
-
67349158685
-
Spin echo SPI methods for quantitative analysis of fluids in porous media
-
Lin L, Han H, Balcom BJ. 2009. Spin echo SPI methods for quantitative analysis of fluids in porous media. J Magn Reson 198: 252-260.
-
(2009)
J Magn Reson
, vol.198
, pp. 252-260
-
-
Lin, L.1
Han, H.2
Balcom, B.J.3
|