Volumn 23, Issue 1, 2010, Pages 39-43

Eddy current effects on a clinical 7T-68 cm bore scanner

Author keywords

7 Tesla; Eddy currents; Head only magnet

Indexed keywords

ARTICLE; COMPUTER ASSISTED DIAGNOSIS; ELECTROMAGNETIC FIELD; HEAD; HUMAN; IMAGE QUALITY; IMPEDANCE; INSTRUMENTATION; MAGNETISM; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; PHYSIOLOGY; WHOLE BODY IMAGING;

EID: 76649092326     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-009-0192-0     Document Type: Article
Times cited : (12)

References (9)
  • 1
    • 33750632039 scopus 로고    scopus 로고
    • Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition
    • DOI 10.1002/mrm.21043
    • V Mlynarik G Gambarota H Frenkel R Gruetter 2006 Localized short-echo-time proton MR spectroscopy with full signal-intensity acquisition Magn Reson Med 56 5 965 970 10.1002/mrm.21043 1:CAS:528:DC%2BD28Xht1KlsrfE 16991116 (Pubitemid 44691337)
    • (2006) Magnetic Resonance in Medicine , vol.56 , Issue.5 , pp. 965-970
    • Mlynarik, V.1    Gambarota, G.2    Frenkel, H.3    Gruetter, R.4
  • 4
    • 0032012581 scopus 로고    scopus 로고
    • Localized eddy current compensation using quantitative field mapping
    • 10.1006/jmre.1997.1353 1:CAS:528:DyaK1cXitlahs7s%3D 9533916
    • M Terpstra PM Andersen R Gruetter 1998 Localized eddy current compensation using quantitative field mapping J Magn Reson 131 1 139 143 10.1006/jmre.1997.1353 1:CAS:528:DyaK1cXitlahs7s%3D 9533916
    • (1998) J Magn Reson , vol.131 , Issue.1 , pp. 139-143
    • Terpstra, M.1    Andersen, P.M.2    Gruetter, R.3
  • 6
    • 76649103057 scopus 로고    scopus 로고
    • High-quality spectroscopy of the human brain with full signal intensity at echo times below 6 ms on a clinical platform at 3T and 7T
    • R Mekle V Mlynarik G Gambarota M Hergt G Krueger R Gruetter 2008 High-quality spectroscopy of the human brain with full signal intensity at echo times below 6 ms on a clinical platform at 3T and 7T Proc Intl Soc Magn Reson Med 15 3245
    • (2008) Proc Intl Soc Magn Reson Med , vol.15 , pp. 3245
    • Mekle, R.1    Mlynarik, V.2    Gambarota, G.3    Hergt, M.4    Krueger, G.5    Gruetter, R.6
  • 7
    • 0027200329 scopus 로고
    • Automatic, localized in vivo adjustment of all first- and second-order shim coils
    • 10.1002/mrm.1910290613 1:STN:280:DyaK3szlsVSktQ%3D%3D 8350724
    • R Gruetter 1993 Automatic, localized in vivo adjustment of all first- and second-order shim coils Magn Reson Med 29 6 804 811 10.1002/mrm.1910290613 1:STN:280:DyaK3szlsVSktQ%3D%3D 8350724
    • (1993) Magn Reson Med , vol.29 , Issue.6 , pp. 804-811
    • Gruetter, R.1
  • 8
    • 0032588957 scopus 로고    scopus 로고
    • 1H NMR spectroscopy of rat brain at 1 ms echo time
    • DOI 10.1002/(SICI)1522-2594(199904)41:4<649::AID-MRM2>3.0.CO;2-G
    • I Tkac Z Starcuk IY Choi R Gruetter 1999 In vivo 1H NMR spectroscopy of rat brain at 1 ms echo time Magn Reson Med 41 4 649 656 10.1002/(SICI)1522- 2594(199904)41:4<649::AID-MRM2>3.0.CO;2-G 1:STN:280:DyaK1M3mtlKhsg%3D%3D 10332839 (Pubitemid 29205710)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.4 , pp. 649-656
    • Tkac, I.1    Starcuk, Z.2    Choi, I.-Y.3    Gruetter, R.4
  • 9
    • 0027375098 scopus 로고
    • Estimation of metabolite concentrations from localized in vivo proton NMR spectra
    • DOI 10.1002/mrm.1910300604
    • SW Provencher 1993 Estimation of metabolite concentrations from localized in vivo proton NMR spectra Magn Reson Med 30 6 672 679 10.1002/mrm.1910300604 1:CAS:528:DyaK2cXis1Gjtr0%3D 8139448 (Pubitemid 23360802)
    • (1993) Magnetic Resonance in Medicine , vol.30 , Issue.6 , pp. 672-679
    • Provencher, S.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.