메뉴 건너뛰기




Volumn 27, Issue 1, 2012, Pages 77-83

Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses

Author keywords

Assembly force; Head taper connection; Modular hip prosthesis; Pull off forces; Turn off capacity

Indexed keywords

ASSEMBLY TOOL; BEARING CONDITIONS; CERAMIC HEADS; COMPONENT ASSEMBLY; ENDOPROSTHESES; ENDOPROSTHESIS; FEMORAL HEADS; HAMMER BLOW; HEAD-TAPER CONNECTION; MATERIAL COMBINATION; MODULAR HIP PROSTHESIS; MOMENT CAPACITY; PULL-OFF FORCES; RELATIVE MOTION; TI-6AL-4V; TURN-OFF CAPACITY;

EID: 84655169208     PISSN: 02680033     EISSN: 18791271     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2011.08.002     Document Type: Article
Times cited : (142)

References (32)
  • 7
    • 53049104576 scopus 로고    scopus 로고
    • Friction moments of large metal-on-metal hip joint bearings and other modern designs
    • N.E. Bishop, F. Waldow, and M.M. Morlock Friction moments of large metal-on-metal hip joint bearings and other modern designs Med. Eng. Phys. 30 2008 1057 1064
    • (2008) Med. Eng. Phys. , vol.30 , pp. 1057-1064
    • Bishop, N.E.1    Waldow, F.2    Morlock, M.M.3
  • 8
    • 0031091465 scopus 로고    scopus 로고
    • Dissociation of modular humeral head components: A biomechanical and implant retrieval study (vol 6, pg 113, 1997)
    • F.T. Blevins, X. Deng, P.A. Torzilli, D. Dines, and R.F. Warren Dissociation of modular humeral head components: a biomechanical and implant retrieval study (vol 6, pg 113, 1997) J. Should. Elb. Surg. 6 1997 563
    • (1997) J. Should. Elb. Surg. , vol.6 , pp. 563
    • Blevins, F.T.1    Deng, X.2    Torzilli, P.A.3    Dines, D.4    Warren, R.F.5
  • 11
    • 0030122410 scopus 로고    scopus 로고
    • Modularity in primary total hip arthroplasty
    • H.U. Cameron Modularity in primary total hip arthroplasty J. Arthroplast. 11 1996 332 334 (Pubitemid 126690914)
    • (1996) Journal of Arthroplasty , vol.11 , Issue.3 , pp. 332-334
    • Cameron, H.U.1
  • 12
    • 77955434244 scopus 로고    scopus 로고
    • Hybrid assembly of metal head and femoral stem from different manufacturers during isolated acetabular revision
    • C.F. Chen, W.M. Chen, C.T. Yang, C.K. Huang, and T.H. Chen Hybrid assembly of metal head and femoral stem from different manufacturers during isolated acetabular revision Artif. Organs 34 2010 E242 E245
    • (2010) Artif. Organs , vol.34
    • Chen, C.F.1    Chen, W.M.2    Yang, C.T.3    Huang, C.K.4    Chen, T.H.5
  • 13
    • 76249133477 scopus 로고    scopus 로고
    • The John Charnley Award metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty a randomized clinical trial
    • D.S. Garbuz, M. Tanzer, N.V. Greidanus, B.A. Masri, and C.P. Duncan The John Charnley Award metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty a randomized clinical trial Clin. Orthop. Relat. Res. 468 2010 318 325
    • (2010) Clin. Orthop. Relat. Res. , vol.468 , pp. 318-325
    • Garbuz, D.S.1    Tanzer, M.2    Greidanus, N.V.3    Masri, B.A.4    Duncan, C.P.5
  • 18
    • 67349248397 scopus 로고    scopus 로고
    • Impact magnitudes applied by surgeons and their importance when applying the femoral head onto the Morse taper for total hip arthroplasty
    • J.P. Heiney, S. Battula, G.A. Vrabec, A. Parikh, R. Blice, and A.J. Schoenfeld Impact magnitudes applied by surgeons and their importance when applying the femoral head onto the Morse taper for total hip arthroplasty Arch. Orthop. Trauma Surg. 129 2009 793 796
    • (2009) Arch. Orthop. Trauma Surg. , vol.129 , pp. 793-796
    • Heiney, J.P.1    Battula, S.2    Vrabec, G.A.3    Parikh, A.4    Blice, R.5    Schoenfeld, A.J.6
  • 19
    • 79952043319 scopus 로고    scopus 로고
    • The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations
    • A. Hothan, G. Huber, C. Weiss, N. Hoffmann, and M. Morlock The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations J. Biomech. 44 2011 837 841
    • (2011) J. Biomech. , vol.44 , pp. 837-841
    • Hothan, A.1    Huber, G.2    Weiss, C.3    Hoffmann, N.4    Morlock, M.5
  • 20
    • 0029900609 scopus 로고    scopus 로고
    • Head-neck modularity for total hip arthroplasty: Is it necessary?
    • DOI 10.1016/S0883-5403(96)80028-3
    • W.J. Hozack, J.J. Mesa, and R.F. Rothman Head-neck modularity for total hip arthroplasty-is it necessary? J. Arthroplast. 11 1996 397 399 (Pubitemid 26193524)
    • (1996) Journal of Arthroplasty , vol.11 , Issue.4 , pp. 397-399
    • Hozack, W.J.1    Mesa, J.J.2    Rothman, R.H.3
  • 23
    • 79956324053 scopus 로고    scopus 로고
    • Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: The potential influence of the adapter sleeve
    • M. Lavigne, E.L. Belzile, A. Roy, F. Morin, T. Amzica, and P.A. Vendittoli Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve J. Bone Joint Surg.-Am. 93A 2011 128 136
    • (2011) J. Bone Joint Surg.-Am. , vol.93 A , pp. 128-136
    • Lavigne, M.1    Belzile, E.L.2    Roy, A.3    Morin, F.4    Amzica, T.5    Vendittoli, P.A.6
  • 24
    • 69249208803 scopus 로고    scopus 로고
    • High cup angle and microseparation increase the wear of hip surface replacements
    • I.J. Leslie, S. Williams, G. Isaac, E. Ingham, and J. Fisher High cup angle and microseparation increase the wear of hip surface replacements Clin. Orthop. Relat. Res. 467 2009 2259 2265
    • (2009) Clin. Orthop. Relat. Res. , vol.467 , pp. 2259-2265
    • Leslie, I.J.1    Williams, S.2    Isaac, G.3    Ingham, E.4    Fisher, J.5
  • 27
    • 33747316989 scopus 로고    scopus 로고
    • Relevance of the insertion force for the taper lock reliability of a hip stem and a ceramic femoral head
    • R. Nassutt, I. Mollenhauer, K. Klingbeil, O. Hennig, and H. Grundei Relevance of the insertion force for the taper lock reliability of a hip stem and a ceramic femoral head Biomed. Tech. 51 2006 103 109
    • (2006) Biomed. Tech. , vol.51 , pp. 103-109
    • Nassutt, R.1    Mollenhauer, I.2    Klingbeil, K.3    Hennig, O.4    Grundei, H.5
  • 28
    • 0025278251 scopus 로고
    • Disassembly of a modular femoral component during closed reduction of the dislocated femoral component. A case report
    • P.M. Pellicci, and S.B. Haas Disassembly of a modular femoral component during closed reduction of the dislocated femoral component-a case-report J. Bone Joint Surg.-Am. 72A 1990 619 620 (Pubitemid 20150433)
    • (1990) Journal of Bone and Joint Surgery - Series A , vol.72 , Issue.4 , pp. 619-620
    • Pellicci, P.M.1    Haas, S.B.2
  • 29
    • 0036714805 scopus 로고    scopus 로고
    • Morse-type tapers: Factors that may influence taper strength during total hip arthroplasty
    • DOI 10.1054/arth.2002.33565
    • A.T. Pennock, A.H. Schmidt, and C.A. Bourgeault Morse-type tapers-factors that may influence taper strength during total hip arthroplasty J. Arthroplast. 17 2002 773 778 (Pubitemid 35001182)
    • (2002) Journal of Arthroplasty , vol.17 , Issue.6 , pp. 773-778
    • Pennock, A.T.1    Schmidt, A.H.2    Bourgeault, C.A.3
  • 32
    • 0025265994 scopus 로고
    • Disassembly of a modular femoral prosthesis after dislocation of the femoral component. A case report
    • S.T. Woolson, and G.T. Pottorff Disassembly of a modular femoral prosthesis after dislocation of the femoral component-a case-report J. Bone. Joint Surg.-Am. 72A 1990 624 625 (Pubitemid 20150435)
    • (1990) Journal of Bone and Joint Surgery - Series A , vol.72 , Issue.4 , pp. 624-625
    • Woolson, S.T.1    Pottorff, G.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.