메뉴 건너뛰기




Volumn 11, Issue 4, 1996, Pages 397-399

Head-neck modularity for total hip arthroplasty: Is it necessary?

Author keywords

leg length; modularity; total hip arthroplasty

Indexed keywords

ARTICLE; CLINICAL TRIAL; FEMUR HEAD PROSTHESIS; FEMUR NECK; HUMAN; IMPLANTATION; JOINT STABILITY; LEG LENGTH INEQUALITY; MAJOR CLINICAL STUDY; THICKNESS; TOTAL HIP PROSTHESIS;

EID: 0029900609     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(96)80028-3     Document Type: Article
Times cited : (30)

References (17)
  • 1
    • 0002611871 scopus 로고
    • Modularity of prosthetic implants
    • Barrack RL: Modularity of prosthetic implants. J Am Acad Orthop Surg 2:16, 1994
    • (1994) J Am Acad Orthop Surg , vol.2 , pp. 16
    • Barrack, R.L.1
  • 2
    • 0028121040 scopus 로고
    • Concerns with modularity in total hip arthroplasty
    • Bobyn JD, Tanzer M, Krygier JJ et al: Concerns with modularity in total hip arthroplasty. Clin Orthop 298:27, 1994
    • (1994) Clin Orthop , vol.298 , pp. 27
    • Bobyn, J.D.1    Tanzer, M.2    Krygier, J.J.3
  • 3
    • 0025649634 scopus 로고
    • Dissociation of acetabular components after total hip arthroplasty: Report of four cases
    • Brien WW, Salvati EA, Wright TM et al: Dissociation of acetabular components after total hip arthroplasty: report of four cases. J Bone Joint Surg 72 A: 1548, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 1548
    • Brien, W.W.1    Salvati, E.A.2    Wright, T.M.3
  • 4
    • 0025319780 scopus 로고
    • Disassembly of a modular acetabular component of a total hip replacement arthroplasty: A case report
    • Kitziger KJ, DeLee JC, Evans JA: Disassembly of a modular acetabular component of a total hip replacement arthroplasty: a case report. J Bone Joint Surg 72A:621, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 621
    • Kitziger, K.J.1    DeLee, J.C.2    Evans, J.A.3
  • 5
    • 0025278251 scopus 로고
    • Disassembly of a modular femoral component during closed reduction of the dislocated femoral component: A case report
    • Pellicci PM, Haas SB: Disassembly of a modular femoral component during closed reduction of the dislocated femoral component: a case report. J Bone Joint Surg 72A:619, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 619
    • Pellicci, P.M.1    Haas, S.B.2
  • 6
    • 0025265994 scopus 로고
    • Disassembly of a modular femoral prosthesis after dislocation of the femoral component: A case report
    • Woolson ST, Pottorff GT: Disassembly of a modular femoral prosthesis after dislocation of the femoral component: a case report. J Bone Joint Surg 72A: 624, 1990
    • (1990) J Bone Joint Surg , vol.72 A , pp. 624
    • Woolson, S.T.1    Pottorff, G.T.2
  • 7
    • 0027255478 scopus 로고
    • Complications related to modularity of total hip components
    • Barrack RL, Burke DW, Cook SD et al: Complications related to modularity of total hip components. J Bone Joint Surg 75B:688, 1993
    • (1993) J Bone Joint Surg , vol.75 B , pp. 688
    • Barrack, R.L.1    Burke, D.W.2    Cook, S.D.3
  • 8
    • 0026773329 scopus 로고
    • Corrosion between the components of modular femoral hip prostheses
    • Collier JP, Surprenant VA, Jensen RE et al: Corrosion between the components of modular femoral hip prostheses. J Bone Joint Surg 74B:511, 1992
    • (1992) J Bone Joint Surg , vol.74 B , pp. 511
    • Collier, J.P.1    Surprenant, V.A.2    Jensen, R.E.3
  • 9
    • 0028054956 scopus 로고
    • Wear and corrosion of modular interfaces in total hip replacements
    • Cook SD, Barrack RL, Baffes GC et al: Wear and corrosion of modular interfaces in total hip replacements. Clin Orthop 298:80, 1994
    • (1994) Clin Orthop , vol.298 , pp. 80
    • Cook, S.D.1    Barrack, R.L.2    Baffes, G.C.3
  • 10
    • 0028063951 scopus 로고
    • Corrosion and wear at the modular interface of uncemented femoral stems
    • Cook SD, Barrack RL, Clemow AJT: Corrosion and wear at the modular interface of uncemented femoral stems. J Bone Joint Surg 76B:68, 1994
    • (1994) J Bone Joint Surg , vol.76 B , pp. 68
    • Cook, S.D.1    Barrack, R.L.2    Clemow, A.J.T.3
  • 11
    • 0027897650 scopus 로고
    • In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations: The effect of crevice, stress, motion, and alloy coupling
    • Gilbert JL, Buckley CA, Jacobs JJ: In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations: the effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res 27:1533, 1993
    • (1993) J Biomed Mater Res , vol.27 , pp. 1533
    • Gilbert, J.L.1    Buckley, C.A.2    Jacobs, J.J.3
  • 12
    • 0028245867 scopus 로고
    • Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
    • Huk OL, Bansal M, Betts F et al: Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Joint Surg 76B:568, 1994
    • (1994) J Bone Joint Surg , vol.76 B , pp. 568
    • Huk, O.L.1    Bansal, M.2    Betts, F.3
  • 13
    • 0028197402 scopus 로고
    • An analysis of the head-neck taper interface in retrieved hip prostheses
    • Lieberman JR, Rimnac CM, Garvin KL et al: An analysis of the head-neck taper interface in retrieved hip prostheses. Clin Orthop 300:162, 1994
    • (1994) Clin Orthop , vol.300 , pp. 162
    • Lieberman, J.R.1    Rimnac, C.M.2    Garvin, K.L.3
  • 16
    • 0025912479 scopus 로고
    • Range of motion in contemporary total hip arthroplasty: The impact of modular head-neck components
    • Krushell RJ, Burke DW, Harris WH: Range of motion in contemporary total hip arthroplasty: the impact of modular head-neck components. J Arthroplasty 6:97, 1991
    • (1991) J Arthroplasty , vol.6 , pp. 97
    • Krushell, R.J.1    Burke, D.W.2    Harris, W.H.3
  • 17
    • 0028054273 scopus 로고
    • Taperloc femoral component: A 2-6 year study of the first 100 consecutive cases
    • Hozack WJ, Gardiner G, Hearn S et al: Taperloc femoral component: a 2-6 year study of the first 100 consecutive cases. J Arthroplasty 9:489, 1994
    • (1994) J Arthroplasty , vol.9 , pp. 489
    • Hozack, W.J.1    Gardiner, G.2    Hearn, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.