메뉴 건너뛰기




Volumn 30, Issue 8, 2008, Pages 1057-1064

Friction moments of large metal-on-metal hip joint bearings and other modern designs

Author keywords

Acetabulum; Bearing; Friction; Hip; Moment; Tribology

Indexed keywords

BEARINGS (STRUCTURAL); BODY FLUIDS; CERAMIC MATERIALS; CERMETS; FRICTION; HIP PROSTHESES; JOINT PROSTHESES; METALLIC COMPOUNDS; PHASE INTERFACES; STANDARDS; THERMOPLASTICS;

EID: 53049104576     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2008.01.001     Document Type: Article
Times cited : (57)

References (32)
  • 2
    • 0025222261 scopus 로고
    • Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles
    • Willert H.G., Bertram H., and Buchhorn G.H. Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. Clin Orthop Relat Res. 258 (1990) 95-107
    • (1990) Clin Orthop Relat Res. , vol.258 , pp. 95-107
    • Willert, H.G.1    Bertram, H.2    Buchhorn, G.H.3
  • 3
    • 9644273921 scopus 로고    scopus 로고
    • A hip joint simulator study of the performance of metal-on-metal joints, part II: design
    • (8 Suppl 3)
    • Dowson D., Hardaker C., Flett M., and Isaac G.H. A hip joint simulator study of the performance of metal-on-metal joints, part II: design. J Arthroplasty 19 (2004) 124-130 (8 Suppl 3)
    • (2004) J Arthroplasty , vol.19 , pp. 124-130
    • Dowson, D.1    Hardaker, C.2    Flett, M.3    Isaac, G.H.4
  • 4
    • 18244384199 scopus 로고    scopus 로고
    • Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements
    • Milosev I., Pisot V., and Campbell P. Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements. J Orthop Res 23 3 (2005) 526-535
    • (2005) J Orthop Res , vol.23 , Issue.3 , pp. 526-535
    • Milosev, I.1    Pisot, V.2    Campbell, P.3
  • 5
    • 33645235121 scopus 로고    scopus 로고
    • Tribological principles in metal-on-metal hip joint design
    • Dowson D. Tribological principles in metal-on-metal hip joint design. Proc Inst Mech Eng [H] 220 2 (2006) 161-171
    • (2006) Proc Inst Mech Eng [H] , vol.220 , Issue.2 , pp. 161-171
    • Dowson, D.1
  • 6
    • 0034890636 scopus 로고    scopus 로고
    • A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis
    • Firkins P.J., Tipper J.L., Ingham E., Stone M.H., Farrar R., and Fisher J. A novel low wearing differential hardness, ceramic-on-metal hip joint prosthesis. J Biomech 34 10 (2001) 1291-1298
    • (2001) J Biomech , vol.34 , Issue.10 , pp. 1291-1298
    • Firkins, P.J.1    Tipper, J.L.2    Ingham, E.3    Stone, M.H.4    Farrar, R.5    Fisher, J.6
  • 8
    • 0034534762 scopus 로고    scopus 로고
    • A frictional study of total hip joint replacements
    • Scholes S.C., Unsworth A., and Goldsmith A.A. A frictional study of total hip joint replacements. Phys Med Biol 45 12 (2000) 3721-3735
    • (2000) Phys Med Biol , vol.45 , Issue.12 , pp. 3721-3735
    • Scholes, S.C.1    Unsworth, A.2    Goldsmith, A.A.3
  • 9
    • 0016254070 scopus 로고
    • An in vitro experiment to determine the efficiency of fixation of the McKee-Farrar acetabular component in relation to torsional force
    • Chen S.C., Lowe S.A., Scales J.T., and Ansell R.H. An in vitro experiment to determine the efficiency of fixation of the McKee-Farrar acetabular component in relation to torsional force. Acta Orthop Scand 45 3 (1974) 429-435
    • (1974) Acta Orthop Scand , vol.45 , Issue.3 , pp. 429-435
    • Chen, S.C.1    Lowe, S.A.2    Scales, J.T.3    Ansell, R.H.4
  • 10
    • 33645232552 scopus 로고    scopus 로고
    • Lessons learned from early clinical experience and results of 300 ASR hip resurfacing implantations
    • Siebel T., Maubach S., and Morlock M.M. Lessons learned from early clinical experience and results of 300 ASR hip resurfacing implantations. Proc Inst Mech Eng [H] 220 2 (2006) 345-353
    • (2006) Proc Inst Mech Eng [H] , vol.220 , Issue.2 , pp. 345-353
    • Siebel, T.1    Maubach, S.2    Morlock, M.M.3
  • 11
    • 0017956429 scopus 로고
    • Elastohydrodynamic lubriction of elliptical contacts for materials of low elastic modulus I-fully flooded conjunction
    • Hamrock B.J., and Dowson D. Elastohydrodynamic lubriction of elliptical contacts for materials of low elastic modulus I-fully flooded conjunction. J Lubric Technol 100 (1978) 236-245
    • (1978) J Lubric Technol , vol.100 , pp. 236-245
    • Hamrock, B.J.1    Dowson, D.2
  • 15
    • 0033631533 scopus 로고    scopus 로고
    • Comparison of friction and lubrication of different hip prostheses
    • Scholes S.C., and Unsworth A. Comparison of friction and lubrication of different hip prostheses. Proc Inst Mech Eng H 214 1 (2000) 49-57
    • (2000) Proc Inst Mech Eng H , vol.214 , Issue.1 , pp. 49-57
    • Scholes, S.C.1    Unsworth, A.2
  • 16
    • 0032007946 scopus 로고    scopus 로고
    • The fallacy of evaluating biomaterial wear-rates with water as lubricant: a hip simulator study of alumina-PTFE nd CoCr-PTFE combinations
    • Phipatanakul W.P., Johnson S.A., Good V., and Clarke I.C. The fallacy of evaluating biomaterial wear-rates with water as lubricant: a hip simulator study of alumina-PTFE nd CoCr-PTFE combinations. J Biomed Mater Res 39 2 (1998) 229-233
    • (1998) J Biomed Mater Res , vol.39 , Issue.2 , pp. 229-233
    • Phipatanakul, W.P.1    Johnson, S.A.2    Good, V.3    Clarke, I.C.4
  • 18
    • 0036205442 scopus 로고    scopus 로고
    • Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators
    • Saikko V., and Calonius O. Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. J Biomech 35 4 (2002) 455-464
    • (2002) J Biomech , vol.35 , Issue.4 , pp. 455-464
    • Saikko, V.1    Calonius, O.2
  • 20
    • 0017861727 scopus 로고
    • The effects of lubrication in hip joint prostheses
    • Unsworth A. The effects of lubrication in hip joint prostheses. Phys Med Biol 23 2 (1978) 253-268
    • (1978) Phys Med Biol , vol.23 , Issue.2 , pp. 253-268
    • Unsworth, A.1
  • 21
    • 17744365971 scopus 로고    scopus 로고
    • Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases
    • Shimmin A.J., and Back D. Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Joint Surg Br 87 4 (2005) 463-464
    • (2005) J Bone Joint Surg Br , vol.87 , Issue.4 , pp. 463-464
    • Shimmin, A.J.1    Back, D.2
  • 22
    • 4544312502 scopus 로고    scopus 로고
    • Fracture of the neck of the femur after surface arthroplasty of the hip
    • Amstutz H.C., Campbell P.A., and Le Duff M.J. Fracture of the neck of the femur after surface arthroplasty of the hip. J Bone Joint Surg Am 86-A 9 (2004) 1874-1877
    • (2004) J Bone Joint Surg Am , vol.86 -A , Issue.9 , pp. 1874-1877
    • Amstutz, H.C.1    Campbell, P.A.2    Le Duff, M.J.3
  • 23
    • 33645236921 scopus 로고    scopus 로고
    • Biomechanical, morphological, and histological analysis of early failures in hip resurfacing arthroplasty
    • Morlock M.M., Bishop N., Ruther W., Delling G., and Hahn M. Biomechanical, morphological, and histological analysis of early failures in hip resurfacing arthroplasty. Proc Inst Mech Eng H 220 2 (2006) 333-344
    • (2006) Proc Inst Mech Eng H , vol.220 , Issue.2 , pp. 333-344
    • Morlock, M.M.1    Bishop, N.2    Ruther, W.3    Delling, G.4    Hahn, M.5
  • 25
    • 0026707301 scopus 로고
    • Stability of press-fit acetabular cups
    • Adler E., Stuchin S.A., and Kummer F.J. Stability of press-fit acetabular cups. J Arthroplasty 7 3 (1992) 295-301
    • (1992) J Arthroplasty , vol.7 , Issue.3 , pp. 295-301
    • Adler, E.1    Stuchin, S.A.2    Kummer, F.J.3
  • 26
    • 0035229408 scopus 로고    scopus 로고
    • The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements
    • Smith S.L., Dowson D., and Goldsmith A.A. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. Proc Inst Mech Eng H 215 2 (2001) 161-170
    • (2001) Proc Inst Mech Eng H , vol.215 , Issue.2 , pp. 161-170
    • Smith, S.L.1    Dowson, D.2    Goldsmith, A.A.3
  • 28
    • 0742306284 scopus 로고    scopus 로고
    • 3-D model of a total hip replacement in vivo providing hydrodynamic pressure and film thickness for walking and bicycling
    • Meyer D.M., and Tichy J.A. 3-D model of a total hip replacement in vivo providing hydrodynamic pressure and film thickness for walking and bicycling. J Biomech Eng 125 6 (2003) 777-784
    • (2003) J Biomech Eng , vol.125 , Issue.6 , pp. 777-784
    • Meyer, D.M.1    Tichy, J.A.2
  • 29
    • 17044413641 scopus 로고    scopus 로고
    • Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants
    • vii
    • Rieker C.B., Schon R., Konrad R., Liebentritt G., Gnepf P., Shen M., Roberts P., and Grigoris P. Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants. Orthop Clin North Am. 36 2 (2005) 135-142 vii
    • (2005) Orthop Clin North Am. , vol.36 , Issue.2 , pp. 135-142
    • Rieker, C.B.1    Schon, R.2    Konrad, R.3    Liebentritt, G.4    Gnepf, P.5    Shen, M.6    Roberts, P.7    Grigoris, P.8
  • 30
    • 33645302123 scopus 로고    scopus 로고
    • Investigation on stick phenomena in metal-on-metal hip joints after resting periods
    • Wimmer M.A., Nassutt R., Sprecher C., Loos J., Tager G., and Fischer A. Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proc Inst Mech Eng H 220 2 (2006) 219-227
    • (2006) Proc Inst Mech Eng H , vol.220 , Issue.2 , pp. 219-227
    • Wimmer, M.A.1    Nassutt, R.2    Sprecher, C.3    Loos, J.4    Tager, G.5    Fischer, A.6
  • 31
    • 33645216349 scopus 로고    scopus 로고
    • The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies
    • Vassiliou K., Elfick A.P., Scholes S.C., and Unsworth A. The effect of 'running-in' on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies. Proc Inst Mech Eng H 220 2 (2006) 269-277
    • (2006) Proc Inst Mech Eng H , vol.220 , Issue.2 , pp. 269-277
    • Vassiliou, K.1    Elfick, A.P.2    Scholes, S.C.3    Unsworth, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.