-
1
-
-
0033770945
-
Neurocognitive dysfunction after coronary artery bypass surgery: A systematic review
-
Medline. doi:10.1067/mtc.2000.108901
-
van Dijk D, Keizer AM, Diephuis JC, Durand C, Vos LJ, Hijman R. Neurocognitive dysfunction after coronary artery bypass surgery: a systematic review. J Thorac Cardiovasc Surg. 2000;120(4):632-639. Medline. doi:10.1067/mtc.2000.108901
-
(2000)
J Thorac Cardiovasc Surg
, vol.120
, Issue.4
, pp. 632-639
-
-
van Dijk, D.1
Keizer, A.M.2
Diephuis, J.C.3
Durand, C.4
Vos, L.J.5
Hijman, R.6
-
2
-
-
0033041370
-
Cerebral injury after cardiac surgery: Identification of a group at extraordinary risk. Multicenter Study of Perioperative Ischemia Research Group (McSPI) and the Ischemia Research Education Foundation (IREF)
-
Wolman RL, Nussmeier NA, Aggarwal A, et al. Cerebral injury after cardiac surgery: identification of a group at extraordinary risk. Multicenter Study of Perioperative Ischemia Research Group (McSPI) and the Ischemia Research Education Foundation (IREF). Stroke. 1999;30(3):514-522.
-
(1999)
Stroke
, vol.30
, Issue.3
, pp. 514-522
-
-
Wolman, R.L.1
Nussmeier, N.A.2
Aggarwal, A.3
-
3
-
-
0028914566
-
Macroemboli and microemboli during cardio-pulmonary bypass
-
Medline. doi:10.1016/0003-4975(95)00105-T
-
Blauth CI. Macroemboli and microemboli during cardio-pulmonary bypass. Ann Thorac Surg. 1995;59:1300-1303. Medline. doi:10.1016/0003-4975(95)00105-T
-
(1995)
Ann Thorac Surg
, vol.59
, pp. 1300-1303
-
-
Blauth, C.I.1
-
5
-
-
0036193074
-
How effective are cardiopulmonary bypass circuits at removing gaseous microemboli?
-
Jones TJ, Deal DD, Vernon JC, Blackburn N, Stump DA. How effective are cardiopulmonary bypass circuits at removing gaseous microemboli? J Extra Corpor Technol. 2002;34:34-39.
-
(2002)
J Extra Corpor Technol
, vol.34
, pp. 34-39
-
-
Jones, T.J.1
Deal, D.D.2
Vernon, J.C.3
Blackburn, N.4
Stump, D.A.5
-
6
-
-
0344062806
-
Doppler microembolic signals during cardiac surgery: Comparison between arterial line and middle cerebral artery
-
Medline. doi:10.1016/S0022-5223(03)01197-8
-
Georgiadis D, Hempel A, Baumgartner RW, Zerkowski HR. Doppler microembolic signals during cardiac surgery: comparison between arterial line and middle cerebral artery. J Thorac Cardiovasc Surg. 2003;126:1638-1639. Medline. doi:10.1016/S0022-5223(03)01197-8
-
(2003)
J Thorac Cardiovasc Surg
, vol.126
, pp. 1638-1639
-
-
Georgiadis, D.1
Hempel, A.2
Baumgartner, R.W.3
Zerkowski, H.R.4
-
7
-
-
14544281012
-
Effect of perfusionist technique on cerebral embolization during cardiopulmonary bypass
-
Medline. doi:10.1191/0267659105pf778oa
-
Rodriguez RA, Williams KA, Babaev A, Rubens F, Nathan HJ. Effect of perfusionist technique on cerebral embolization during cardiopulmonary bypass. Perfusion. 2005;20:3-10. Medline. doi:10.1191/0267659105pf778oa
-
(2005)
Perfusion
, vol.20
, pp. 3-10
-
-
Rodriguez, R.A.1
Williams, K.A.2
Babaev, A.3
Rubens, F.4
Nathan, H.J.5
-
8
-
-
20344391919
-
Embolic factors associated with cardiac surgery
-
Medline. doi:10.1177/108925320500900208
-
Stump DA. Embolic factors associated with cardiac surgery. Semin Cardiothorac Vasc Anesth. 2005;9:151-152. Medline. doi:10.1177/108925320500900208
-
(2005)
Semin Cardiothorac Vasc Anesth
, vol.9
, pp. 151-152
-
-
Stump, D.A.1
-
9
-
-
33846361015
-
Neurocognitive function and cerebral emboli: Randomized study of on-pump versus off-pump coronary artery bypass surgery
-
Medline. doi:10.1016/j.athoracsur.2006.09.024
-
Motallebzadeh R, Bland JM, Markus HS, Kaski JC, Jahangiri M. Neurocognitive function and cerebral emboli: Randomized study of on-pump versus off-pump coronary artery bypass surgery. Ann Thorac Surg. 2007;83:475-482. Medline. doi:10.1016/j.athoracsur.2006.09.024
-
(2007)
Ann Thorac Surg
, vol.83
, pp. 475-482
-
-
Motallebzadeh, R.1
Bland, J.M.2
Markus, H.S.3
Kaski, J.C.4
Jahangiri, M.5
-
10
-
-
0035323936
-
Neuropsychologic impairment after coronary bypass surgery: Effect of gaseous microemboli during perfusionist interventions
-
Medline. doi:10.1067/mtc.2001.112526
-
Borger MA, Peniston CM, Weisel RD, Vasiliou M, Green RE, Feindel CM. Neuropsychologic impairment after coronary bypass surgery: effect of gaseous microemboli during perfusionist interventions. J Thorac Cardiovasc Surg. 2001;121:743-749. Medline. doi:10.1067/mtc.2001.112526
-
(2001)
J Thorac Cardiovasc Surg
, vol.121
, pp. 743-749
-
-
Borger, M.A.1
Peniston, C.M.2
Weisel, R.D.3
Vasiliou, M.4
Green, R.E.5
Feindel, C.M.6
-
11
-
-
0032799239
-
Cerebral microemboli during cardiopulmonary bypass: Increased emboli during perfusionist interventions
-
Medline. doi:10.1016/S0003-4975(99)00475-0
-
Taylor RL, Borger MA, Weisel RD, Fedorko L, Feindel CM. Cerebral microemboli during cardiopulmonary bypass: increased emboli during perfusionist interventions. Ann Thorac Surg. 1999;68:89-93. Medline. doi:10.1016/S0003-4975(99)00475-0
-
(1999)
Ann Thorac Surg
, vol.68
, pp. 89-93
-
-
Taylor, R.L.1
Borger, M.A.2
Weisel, R.D.3
Fedorko, L.4
Feindel, C.M.5
-
12
-
-
0042769168
-
Reduction of micro-emboli count in the priming fluid of cardiopulmonary bypass circuits
-
Merkle F, Boettcher W, Schulz F, et al. Reduction of micro-emboli count in the priming fluid of cardiopulmonary bypass circuits. J Extra Corpor Technol. 2003;35:133-138.
-
(2003)
J Extra Corpor Technol
, vol.35
, pp. 133-138
-
-
Merkle, F.1
Boettcher, W.2
Schulz, F.3
-
13
-
-
31044451116
-
Residual air in the venous cannula increases cerebral embolization at the onset of cardiopulmonary bypass
-
Medline. doi:10.1016/j.ejcts.2005.11.006
-
Rodriguez RA, Rubens F, Belway D, Nathan HJ. Residual air in the venous cannula increases cerebral embolization at the onset of cardiopulmonary bypass. Eur J Cardiothorac Surg. 2006;29:175-180. Medline. doi:10.1016/j.ejcts.2005.11.006
-
(2006)
Eur J Cardiothorac Surg
, vol.29
, pp. 175-180
-
-
Rodriguez, R.A.1
Rubens, F.2
Belway, D.3
Nathan, H.J.4
-
14
-
-
77949880406
-
Microemboli in our bypass circuits: A contemporary audit
-
Willcox TW, Mitchell SJ. Microemboli in our bypass circuits: a contemporary audit. J Extra Corpor Technol. 2009;41(4):31-37.
-
(2009)
J Extra Corpor Technol
, vol.41
, Issue.4
, pp. 31-37
-
-
Willcox, T.W.1
Mitchell, S.J.2
-
15
-
-
0032751503
-
Ex vivo testing of the Quart arterial line filter
-
Mueller XM, Tevaearai HT, Jegger D, Augstburger M, Burki M, von Segesser LK. Ex vivo testing of the Quart arterial line filter. Perfusion. 1999;14:481-487.
-
(1999)
Perfusion
, vol.14
, pp. 481-487
-
-
Mueller, X.M.1
Tevaearai, H.T.2
Jegger, D.3
Augstburger, M.4
Burki, M.5
von Segesser, L.K.6
-
16
-
-
55949094037
-
The capability of trapping gaseous microemboli of two pediatric arterial filters with pulsatile and nonpulsatile flow in a simulated infant CPB model
-
Medline. doi:10.1097/MAT.0b013e318184a9ab
-
Wang S, Win KN, Kunselman AR, Woitas K, Myers JL, Undar A. The capability of trapping gaseous microemboli of two pediatric arterial filters with pulsatile and nonpulsatile flow in a simulated infant CPB model. ASAIO J. 2008;54:519-522. Medline. doi:10.1097/MAT.0b013e318184a9ab
-
(2008)
ASAIO J
, vol.54
, pp. 519-522
-
-
Wang, S.1
Win, K.N.2
Kunselman, A.R.3
Woitas, K.4
Myers, J.L.5
Undar, A.6
-
17
-
-
0032722193
-
Venous air in the by-pass circuit: A source of arterial line emboli exacerbated by vacuum-assisted drainage
-
Medline. doi:10.1016/S0003-4975(99)00721-3
-
Willcox TW, Mitchell SJ, Gorman DF. Venous air in the by-pass circuit: a source of arterial line emboli exacerbated by vacuum-assisted drainage. Ann Thorac Surg. 1999;68:1285-1289. Medline. doi:10.1016/S0003-4975(99)00721-3
-
(1999)
Ann Thorac Surg
, vol.68
, pp. 1285-1289
-
-
Willcox, T.W.1
Mitchell, S.J.2
Gorman, D.F.3
-
18
-
-
55949108154
-
Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model
-
Medline. doi:10.1097/MAT.0b013e318185da5b
-
Wang S, Kunselman AR, Myers JL, Undar A. Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model. ASAIO J. 2008;54:538-541. Medline. doi:10.1097/MAT.0b013e318185da5b
-
(2008)
ASAIO J
, vol.54
, pp. 538-541
-
-
Wang, S.1
Kunselman, A.R.2
Myers, J.L.3
Undar, A.4
-
19
-
-
36549055239
-
Detection and classification of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated neonatal CPB model
-
Medline. doi:10.1097/ MAT.0b013e3181588dc3
-
Ündar A, Ji B, Kunselman AR, Myers JL. Detection and classification of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated neonatal CPB model. ASAIO J. 2007;53:725-729. Medline. doi:10.1097/ MAT.0b013e3181588dc3
-
(2007)
ASAIO J
, vol.53
, pp. 725-729
-
-
Ündar, A.1
Ji, B.2
Kunselman, A.R.3
Myers, J.L.4
-
20
-
-
46249109869
-
Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures
-
Medline. doi:10.1097/ MAT.0b013e31816ecfff
-
Schreiner RS, Rider AR, Myers JW, et al. Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures. ASAIO J. 2008;54:316-324. Medline. doi:10.1097/ MAT.0b013e31816ecfff
-
(2008)
ASAIO J
, vol.54
, pp. 316-324
-
-
Schreiner, R.S.1
Rider, A.R.2
Myers, J.W.3
-
21
-
-
51149097948
-
Delivery of gaseous microemboli with vacuum-assisted venous drainage during pulsatile and nonpulsatile perfusion in a simulated neonatal cardiopulmonary bypass model
-
Medline. doi:10.1097/ MAT.0b013e3181772c7b
-
Wang S, Baer L, Kunselman AR, Myers JL, Undar A. Delivery of gaseous microemboli with vacuum-assisted venous drainage during pulsatile and nonpulsatile perfusion in a simulated neonatal cardiopulmonary bypass model. ASAIO J. 2008;54:416-422. Medline. doi:10.1097/ MAT.0b013e3181772c7b
-
(2008)
ASAIO J
, vol.54
, pp. 416-422
-
-
Wang, S.1
Baer, L.2
Kunselman, A.R.3
Myers, J.L.4
Undar, A.5
-
22
-
-
33947226359
-
Comparison of two different extracorporeal circuits on cerebral embolization during cardio-pulmonary bypass in children
-
Medline. doi:10.1177/0267659106074764
-
Rodriguez RA, Belway D. Comparison of two different extracorporeal circuits on cerebral embolization during cardio-pulmonary bypass in children. Perfusion. 2006;21:247-253. Medline. doi:10.1177/0267659106074764
-
(2006)
Perfusion
, vol.21
, pp. 247-253
-
-
Rodriguez, R.A.1
Belway, D.2
-
23
-
-
75149194864
-
Gaseous microemboli in a pediatric bypass circuit with an unprimed venous line: An in vitro study
-
Hudacko A, Sievert A, Sistino J. Gaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study. J Extra Corpor Technol. 2009;41:166-171.
-
(2009)
J Extra Corpor Technol
, vol.41
, pp. 166-171
-
-
Hudacko, A.1
Sievert, A.2
Sistino, J.3
-
24
-
-
0029987008
-
Emboli generation by the Medtronic Maxima hard shell adult venous reservoir in cardiopulmonary bypass circuits: A preliminary report
-
Medline. doi:10.1177/026765919601100208
-
Mitchell SJ, Willcox T, MacDougal C, Gorman DF. Emboli generation by the Medtronic Maxima hard shell adult venous reservoir in cardiopulmonary bypass circuits: a preliminary report. Perfusion. 1996;11(2):145-55. Medline. doi:10.1177/026765919601100208
-
(1996)
Perfusion
, vol.11
, Issue.2
, pp. 145-155
-
-
Mitchell, S.J.1
Willcox, T.2
Macdougal, C.3
Gorman, D.F.4
-
25
-
-
0031009313
-
A comparison of gaseous emboli release in five membrane oxygenators
-
Beckley PD, Shinko PD, Sites JP. A comparison of gaseous emboli release in five membrane oxygenators. Perfusion. 1997;12:133-141.
-
(1997)
Perfusion
, vol.12
, pp. 133-141
-
-
Beckley, P.D.1
Shinko, P.D.2
Sites, J.P.3
-
26
-
-
0028838024
-
Microemboli during coronary artery bypass grafting. Genesis and effect on outcome
-
Medline. doi:10.1016/S0022-5223(95)70386-1
-
Clark RE, Brillman J, Davis DA, Lovell MR, Price TR, Ma-govern GJ. Microemboli during coronary artery bypass grafting. Genesis and effect on outcome. J Thorac Cardiovasc Surg. 1995;109:249-257. Medline. doi:10.1016/S0022-5223(95)70386-1
-
(1995)
J Thorac Cardiovasc Surg
, vol.109
, pp. 249-257
-
-
Clark, R.E.1
Brillman, J.2
Davis, D.A.3
Lovell, M.R.4
Price, T.R.5
Ma-Govern, G.J.6
-
27
-
-
0035160453
-
Cerebral embolisation during modern cardiopulmonary bypass
-
Medline. doi:10.1016/S1010-7940(01)00981-2
-
Fearn SJ, Pole R, Burgess M, Ray SG, Hooper TL, McCollum CN. Cerebral embolisation during modern cardiopulmonary bypass. Eur J Cardiothorac Surg. 2001;20:1163-1167. Medline. doi:10.1016/S1010-7940(01)00981-2
-
(2001)
Eur J Cardiothorac Surg
, vol.20
, pp. 1163-1167
-
-
Fearn, S.J.1
Pole, R.2
Burgess, M.3
Ray, S.G.4
Hooper, T.L.5
McCollum, C.N.6
-
28
-
-
33846396117
-
Gaseous and solid cerebral microembolization during proximal aortic anastomoses in off-pump coronary surgery: The effect of an aortic side-biting clamp and two clampless devices
-
Medline. doi:10.1016/j.jtcvs.2006.10.002
-
Guerrieri Wolf L, Abu-Omar Y, Choudhary BP, Pigott D, Taggart DP. Gaseous and solid cerebral microembolization during proximal aortic anastomoses in off-pump coronary surgery: the effect of an aortic side-biting clamp and two clampless devices. J Thorac Cardiovasc Surg. 2007;133:485-493. Medline. doi:10.1016/j.jtcvs.2006.10.002
-
(2007)
J Thorac Cardiovasc Surg
, vol.133
, pp. 485-493
-
-
Guerrieri, W.L.1
Abu-Omar, Y.2
Choudhary, B.P.3
Pigott, D.4
Taggart, D.P.5
-
29
-
-
0029111518
-
Intraoperative echocardiographic study of air embolism during cardiac operations
-
Medline. doi:10.1016/0003-4975(95)00577-8
-
Tingleff J, Joyce FS, Pettersson G. Intraoperative echocardiographic study of air embolism during cardiac operations. Ann Thorac Surg. 1995;60:673-677. Medline. doi:10.1016/0003-4975(95)00577-8
-
(1995)
Ann Thorac Surg
, vol.60
, pp. 673-677
-
-
Tingleff, J.1
Joyce, F.S.2
Pettersson, G.3
-
30
-
-
1542411428
-
Effect of CO2 in-sufflation on the number and behavior of air microemboli in open-heart surgery: A randomized clinical trial
-
Svenarud P, Persson M, van der Linden J. Effect of CO2 in-sufflation on the number and behavior of air microemboli in open-heart surgery: a randomized clinical trial. Circulation. 2004 9; 109: 1127-32.
-
(2004)
Circulation
, vol.9
, Issue.109
, pp. 1127-1132
-
-
Svenarud, P.1
Persson, M.2
van der Linden, J.3
-
31
-
-
0026099832
-
When do cerebral emboli appear during open heart operations? A transcranial Doppler study
-
Medline. doi:10.1016/0003-4975(91)90793-P
-
van der Linden J, Casimir-Ahn H. When do cerebral emboli appear during open heart operations? A transcranial Doppler study. Ann Thorac Surg. 1991;51:237-241. Medline. doi:10.1016/0003-4975(91)90793-P
-
(1991)
Ann Thorac Surg
, vol.51
, pp. 237-241
-
-
van der Linden, J.1
Casimir-Ahn, H.2
-
32
-
-
77249153313
-
Microembolic signals and strategy to prevent gas embolism during extracorporeal membrane oxygenation
-
Medline
-
Zanatta P, Forti A, Bosco E, et al. Microembolic signals and strategy to prevent gas embolism during extracorporeal membrane oxygenation. J Cardiothorac Surg 2010; 5: 5. Medline.
-
(2010)
J Cardiothorac Surg
, vol.5
, pp. 5
-
-
Zanatta, P.1
Forti, A.2
Bosco, E.3
-
33
-
-
70450280524
-
Clinical real-time monitoring of gaseous microemboli in pediatric cardiopulmonary bypass
-
Medline. doi:10.1111/j.1525-1594.2009.00910.x
-
Wang S, Woitas K, Clark JB, Myers JL, Undar A. Clinical real-time monitoring of gaseous microemboli in pediatric cardiopulmonary bypass. Artif Organs. 2009;33:1026-1030. Medline. doi:10.1111/j.1525-1594.2009.00910.x
-
(2009)
Artif Organs
, vol.33
, pp. 1026-1030
-
-
Wang, S.1
Woitas, K.2
Clark, J.B.3
Myers, J.L.4
Undar, A.5
-
34
-
-
50649090694
-
Microemboli detection on extracorpo-real bypass circuits
-
Medline. doi:10.1177/0267659108094350
-
Lynch JE, Riley JB. Microemboli detection on extracorpo-real bypass circuits. Perfusion. 2008;23:23-32. Medline. doi:10.1177/0267659108094350
-
(2008)
Perfusion
, vol.23
, pp. 23-32
-
-
Lynch, J.E.1
Riley, J.B.2
-
36
-
-
0026024338
-
Detection of arterial emboli using Doppler ultrasound in rabbits
-
Russell D, Madden KP, Clark WM, Sandset PM, Zivin JA. Detection of arterial emboli using Doppler ultrasound in rabbits. Stroke. 1991;22:253-258.
-
(1991)
Stroke
, vol.22
, pp. 253-258
-
-
Russell, D.1
Madden, K.P.2
Clark, W.M.3
Sandset, P.M.4
Zivin, J.A.5
-
37
-
-
0031894263
-
Consensus on microembolus detection by TCD. International consensus group on microembolus detection
-
Ringelstein EB, Droste DW, Babikian VL, et al. Consensus on microembolus detection by TCD. International consensus group on microembolus detection. Stroke. 1998;29:725-729.
-
(1998)
Stroke
, vol.29
, pp. 725-729
-
-
Ringelstein, E.B.1
Droste, D.W.2
Babikian, V.L.3
-
38
-
-
0027521526
-
Silent cerebral embolism caused by neurologically symptomatic high-grade carotid stenosis
-
Medline. doi:10.1093/brain/116.5.1005
-
Siebler M, Sitzer M, Rose G, Bendfeldt D, Steinmetz H. Silent cerebral embolism caused by neurologically symptomatic high-grade carotid stenosis. Brain. 1993;116:1005-1015. Medline. doi:10.1093/brain/116.5.1005
-
(1993)
Brain
, vol.116
, pp. 1005-1015
-
-
Siebler, M.1
Sitzer, M.2
Rose, G.3
Bendfeldt, D.4
Steinmetz, H.5
-
39
-
-
0029131148
-
Asymptomatic cerebral embolic signals in symptomatic and asymptomatic carotid artery disease
-
Medline. doi:10.1093/brain/118.4.1005
-
Markus HS, Thomson N, Brown MM. Asymptomatic cerebral embolic signals in symptomatic and asymptomatic carotid artery disease. Brain. 1995;118:1005-1011. Medline. doi:10.1093/brain/118.4.1005
-
(1995)
Brain
, vol.118
, pp. 1005-1011
-
-
Markus, H.S.1
Thomson, N.2
Brown, M.M.3
-
40
-
-
0029041693
-
Basic identification criteria of Doppler microembolic signals
-
Consensus Committee of the Ninth International Cerebral Hemodynamic Symposium, Medline
-
Consensus Committee of the Ninth International Cerebral Hemodynamic Symposium. Basic identification criteria of Doppler microembolic signals. Stroke. 1995;26(6):1123. Medline.
-
(1995)
Stroke
, vol.26
, Issue.6
, pp. 1123
-
-
-
41
-
-
0029900882
-
How good is intercenter agreement in the identification of embolic signals in carotid artery disease?
-
Medline
-
Markus H, Bland M, Rose G, Sitzer M, Siebler M. How good is intercenter agreement in the identification of embolic signals in carotid artery disease? Stroke. 1996;27:1249-1252. Medline.
-
(1996)
Stroke
, vol.27
, pp. 1249-1252
-
-
Markus, H.1
Bland, M.2
Rose, G.3
Sitzer, M.4
Siebler, M.5
-
42
-
-
0030890451
-
Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves
-
Medline
-
Droste DW, Hagedorn G, Notzold A, Siemens HJ, Sievers HH, Kaps M. Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac valves. Stroke. 1997;28:588-592. Medline.
-
(1997)
Stroke
, vol.28
, pp. 588-592
-
-
Droste, D.W.1
Hagedorn, G.2
Notzold, A.3
Siemens, H.J.4
Sievers, H.H.5
Kaps, M.6
-
43
-
-
0025317321
-
Detection of middle cerebral emboli during carotid endarterectomy using transcranial Doppler ultrasonography
-
Medline
-
Spencer MP, Thomas GI, Nicholls SC, Sauvage LR. Detection of middle cerebral emboli during carotid endarterectomy using transcranial Doppler ultrasonography. Stroke. 1990;21:415-423. Medline.
-
(1990)
Stroke
, vol.21
, pp. 415-423
-
-
Spencer, M.P.1
Thomas, G.I.2
Nicholls, S.C.3
Sauvage, L.R.4
-
44
-
-
57549085563
-
A method to distinguish between gaseous and solid cerebral emboli in patients with prosthetic heart valves
-
Medline. doi:10.1016/j. ejcts.2008.09.020
-
Rodriguez RA, Nathan HJ, Ruel M, Rubens F, Dafoe D, Mesana T. A method to distinguish between gaseous and solid cerebral emboli in patients with prosthetic heart valves. Eur J Cardiothorac Surg. 2009;35:89-95. Medline. doi:10.1016/j. ejcts.2008.09.020
-
(2009)
Eur J Cardiothorac Surg
, vol.35
, pp. 89-95
-
-
Rodriguez, R.A.1
Nathan, H.J.2
Ruel, M.3
Rubens, F.4
Dafoe, D.5
Mesana, T.6
-
45
-
-
0036327315
-
Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler
-
Medline. doi:10.1161/01.STR.0000022811.46115.70
-
Brucher R, Russell D. Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler. Stroke. 2002;33:1969-1974. Medline. doi:10.1161/01.STR.0000022811.46115.70
-
(2002)
Stroke
, vol.33
, pp. 1969-1974
-
-
Brucher, R.1
Russell, D.2
-
46
-
-
23244462315
-
Can transcranial Doppler discriminate between solid and gaseous microemboli? Assessment of a dual-frequency transducer system
-
Medline. doi:10.1161/01.STR.0000173399.20127.b3
-
Markus HS, Punter M. Can transcranial Doppler discriminate between solid and gaseous microemboli? Assessment of a dual-frequency transducer system. Stroke. 2005;36:1731-1734. Medline. doi:10.1161/01.STR.0000173399.20127.b3
-
(2005)
Stroke
, vol.36
, pp. 1731-1734
-
-
Markus, H.S.1
Punter, M.2
-
47
-
-
34548834165
-
Gaseous microemboli sizing in extracorporeal circuits using ultrasound backscatter
-
Medline. doi:10.1016/j.ultrasmedbio.2007.04.008
-
Lynch JE, Pouch A, Sanders R, Hinders M, Rudd K, Sevick J. Gaseous microemboli sizing in extracorporeal circuits using ultrasound backscatter. Ultrasound Med Biol. 2007;33:1661-1675 Medline. doi:10.1016/j.ultrasmedbio.2007.04.008
-
(2007)
Ultrasound Med Biol
, vol.33
, pp. 1661-1675
-
-
Lynch, J.E.1
Pouch, A.2
Sanders, R.3
Hinders, M.4
Rudd, K.5
Sevick, J.6
-
48
-
-
0035181574
-
Investigation on the ability of an ultrasound bubble detector to deliver size measurements of gaseous bubbles in fluid lines by using a glass bead model
-
Medline. doi:10.1097/00002480-200101000-00006
-
Eitschberger S, Henseler A, Krasenbrink B, Oedekoven B, Mottaghy K. Investigation on the ability of an ultrasound bubble detector to deliver size measurements of gaseous bubbles in fluid lines by using a glass bead model. ASAIO J. 2001;47:18-24. Medline. doi:10.1097/00002480-200101000-00006
-
(2001)
ASAIO J
, vol.47
, pp. 18-24
-
-
Eitschberger, S.1
Henseler, A.2
Krasenbrink, B.3
Oedekoven, B.4
Mottaghy, K.5
-
50
-
-
0032872306
-
Theoretical and experimental intravascular gas embolism absorption dynamics
-
Branger AB, Eckmann DM. Theoretical and experimental intravascular gas embolism absorption dynamics. J Appl Physiol. 1999;87:1287-1295.
-
(1999)
J Appl Physiol
, vol.87
, pp. 1287-1295
-
-
Branger, A.B.1
Eckmann, D.M.2
-
51
-
-
84991266717
-
Air embolism as a cause of the systemic inflammatory response: A case report
-
Medline. doi:10.1186/cc2362
-
Kapoor T, Gutierrez G. Air embolism as a cause of the systemic inflammatory response: a case report. Crit Care. 2003;7:R98-R100. Medline. doi:10.1186/cc2362
-
(2003)
Crit Care
, vol.7
-
-
Kapoor, T.1
Gutierrez, G.2
-
52
-
-
0027366409
-
Significance of gaseous microemboli in the cerebral circulation during cardiopulmonary bypass in dogs
-
Medline
-
Johnston WE, Stump DA, DeWitt DS, et al. Significance of gaseous microemboli in the cerebral circulation during cardiopulmonary bypass in dogs. Circulation. 1993;88(1):319-321 Medline.
-
(1993)
Circulation
, vol.88
, Issue.1
, pp. 319-321
-
-
Johnston, W.E.1
Stump, D.A.2
Dewitt, D.S.3
-
53
-
-
0042344941
-
Embolism bubble adhesion force in excised perfused microvessels
-
Medline. doi:10.1097/00000542-200308000-00022
-
Suzuki A, Eckmann DM. Embolism bubble adhesion force in excised perfused microvessels. Anesthesiology. 2003;99:400-408. Medline. doi:10.1097/00000542-200308000-00022
-
(2003)
Anesthesiology
, vol.99
, pp. 400-408
-
-
Suzuki, A.1
Eckmann, D.M.2
-
54
-
-
0024209852
-
Pulmonary embolism: Analysis of endothelial pore sizes in canine lung
-
Townsley MI, Parker JC, Longenecker GL, Perry ML, Pitt RM, Taylor AE. Pulmonary embolism: analysis of endothelial pore sizes in canine lung. Am J Physiol. 1988;255(5 Pt 2):H1075-H1083.
-
(1988)
Am J Physiol
, vol.255
, Issue.2-5 PART
-
-
Townsley, M.I.1
Parker, J.C.2
Longenecker, G.L.3
Perry, M.L.4
Pitt, R.M.5
Taylor, A.E.6
-
55
-
-
3042687096
-
Surfactant reduction in embolism bubble adhesion and endothelial damage
-
Medline. doi:10.1097/00000542-200407000-00016
-
Suzuki A, Armstead SC, Eckmann DM. Surfactant reduction in embolism bubble adhesion and endothelial damage. Anesthesiology. 2004;101:97-103. Medline. doi:10.1097/00000542-200407000-00016
-
(2004)
Anesthesiology
, vol.101
, pp. 97-103
-
-
Suzuki, A.1
Armstead, S.C.2
Eckmann, D.M.3
-
56
-
-
33748699104
-
Microsphere embolism-induced endothelial nitric oxide synthase expression mediates disruption of the blood-brain barrier in rat brain
-
Medline. doi:10.1111/j.1471-4159.2006.04048.x
-
Han F, Shirasaki Y, Fukunaga K. Microsphere embolism-induced endothelial nitric oxide synthase expression mediates disruption of the blood-brain barrier in rat brain. J Neurochem. 2006;99:97-106. Medline. doi:10.1111/j.1471-4159.2006.04048.x
-
(2006)
J Neurochem
, vol.99
, pp. 97-106
-
-
Han, F.1
Shirasaki, Y.2
Fukunaga, K.3
-
57
-
-
0023944166
-
Complement activation in cardiopulmonary bypass, with special reference to anaphylotoxin production in membrane and bubble oxygenators
-
Medline. doi:10.1016/S0003-4975(10)65851-1
-
Tamiya T, Yamasaki M, Maeo Y, Yamashiro T, Ogoshi S, Fujimoto S. Complement activation in cardiopulmonary bypass, with special reference to anaphylotoxin production in membrane and bubble oxygenators. Ann Thorac Surg. 1988;46:47-57. Medline. doi:10.1016/S0003-4975(10)65851-1
-
(1988)
Ann Thorac Surg
, vol.46
, pp. 47-57
-
-
Tamiya, T.1
Yamasaki, M.2
Maeo, Y.3
Yamashiro, T.4
Ogoshi, S.5
Fujimoto, S.6
-
59
-
-
27144506167
-
Microbubbles: Pathophysiology and clinical implications
-
Medline. doi:10.1378/chest.128.4.2918
-
Barak M, Katz Y. Microbubbles: pathophysiology and clinical implications. Chest. 2005;128:2918-2932. Medline. doi:10.1378/chest.128.4.2918
-
(2005)
Chest
, vol.128
, pp. 2918-2932
-
-
Barak, M.1
Katz, Y.2
-
60
-
-
0030330203
-
Diffusion coefficients and solubility coefficients for gases in biological fluids and tissues: A review
-
Medline
-
Langø T, Morland T. Brubakk. Diffusion coefficients and solubility coefficients for gases in biological fluids and tissues: a review. Undersea Hyperb Med. 1996;23:247-272. Medline.
-
(1996)
Undersea Hyperb Med
, vol.23
, pp. 247-272
-
-
Langø, T.1
Brubakk Morland, T.2
-
61
-
-
0042669990
-
Effects of cerebral air embolism on brain metabolism in pigs
-
Medline. doi:10.1034/j.1600-0404.2003.00100.x
-
van Hulst RA, Lameris TW, Hasan D, Klein J, Lachmann B. Effects of cerebral air embolism on brain metabolism in pigs. Acta Neurol Scand. 2003;108:118-124. Medline. doi:10.1034/j.1600-0404.2003.00100.x
-
(2003)
Acta Neurol Scand
, vol.108
, pp. 118-124
-
-
van Hulst, R.A.1
Lameris, T.W.2
Hasan, D.3
Klein, J.4
Lachmann, B.5
-
62
-
-
2442488001
-
Cerebral arterial gas embolism: Should we hyperventilate these patients?
-
Medline. doi:10.1007/s00134-004-2209-5
-
Muth CM, Shank ES. Cerebral arterial gas embolism: should we hyperventilate these patients? Intensive Care Med. 2004;30:742-743. Medline. doi:10.1007/s00134-004-2209-5
-
(2004)
Intensive Care Med
, vol.30
, pp. 742-743
-
-
Muth, C.M.1
Shank, E.S.2
-
63
-
-
31344468909
-
Cognitive and neurobehavioral dysfunction after cardiac bypass procedures
-
Medline. doi:10.1016/j.ncl.2005.10.001
-
Selnes OA, McKhann GM, Borowicz LM, Grega MA. Cognitive and neurobehavioral dysfunction after cardiac bypass procedures. Neurol Clin. 2006;24:133-145. Medline. doi:10.1016/j.ncl.2005.10.001
-
(2006)
Neurol Clin
, vol.24
, pp. 133-145
-
-
Selnes, O.A.1
McKhann, G.M.2
Borowicz, L.M.3
Grega, M.A.4
-
64
-
-
0035825726
-
Longitudinal assessment of neurocognitive function after coronary-artery bypass surgery
-
Medline. doi:10.1056/NEJM200102083440601
-
Newman MF, Kirchner JL, Phillips-Bute B, et al. Longitudinal assessment of neurocognitive function after coronary-artery bypass surgery. N Engl J Med. 2001;344:395-402. Medline. doi:10.1056/NEJM200102083440601
-
(2001)
N Engl J Med
, vol.344
, pp. 395-402
-
-
Newman, M.F.1
Kirchner, J.L.2
Phillips-Bute, B.3
-
65
-
-
0032839765
-
Etiology and incidence of brain dysfunction after cardiac surgery
-
Discussion 36-7
-
Murkin JM. Etiology and incidence of brain dysfunction after cardiac surgery. J Cardiothorac Vasc Anesth 1999;13(4 Suppl 1):12-7;discussion 36-7.
-
(1999)
J Cardiothorac Vasc Anesth
, vol.13
, Issue.1-4 SUPPL.
, pp. 12-17
-
-
Murkin, J.M.1
-
66
-
-
0030816312
-
Risk factors and solutions for the development of neurobehavioral changes after coronary artery bypass grafting
-
Medline. doi:10.1016/S0003-4975(97)00261-0
-
Hammon JW, Stump DA, Kon ND, et al. Risk factors and solutions for the development of neurobehavioral changes after coronary artery bypass grafting. Ann Thorac Surg. 1997;63(6):1613-1618. Medline. doi:10.1016/S0003-4975(97)00261-0
-
(1997)
Ann Thorac Surg
, vol.63
, Issue.6
, pp. 1613-1618
-
-
Hammon, J.W.1
Stump, D.A.2
Kon, N.D.3
-
67
-
-
0028206123
-
The impact of microemboli during cardiopulmonary bypass on neuropsychological functioning
-
Pugsley W, Klinger L, Paschalis C, Treasure T, Harrison M, Newman S. The impact of microemboli during cardiopulmonary bypass on neuropsychological functioning. Stroke. 1994;25:1393-1399.
-
(1994)
Stroke
, vol.25
, pp. 1393-1399
-
-
Pugsley, W.1
Klinger, L.2
Paschalis, C.3
Treasure, T.4
Harrison, M.5
Newman, S.6
-
68
-
-
0032417713
-
Pattern and significance of cerebral microemboli during coronary artery bypass grafting
-
Medline. doi:10.1016/S0003-4975(98)00891-1
-
Sylivris S, Levi C, Matalanis G, et al. Pattern and significance of cerebral microemboli during coronary artery bypass grafting. Ann Thorac Surg. 1998;66:1674-1678. Medline. doi:10.1016/S0003-4975(98)00891-1
-
(1998)
Ann Thorac Surg
, vol.66
, pp. 1674-1678
-
-
Sylivris, S.1
Levi, C.2
Matalanis, G.3
-
69
-
-
0000634636
-
Neuropsychological deficits are associated with the number of emboli detected during cardiac surgery
-
(Abstract)
-
Stump DA, Tegeler CH, Rogers AT, et al. Neuropsychological deficits are associated with the number of emboli detected during cardiac surgery. Stroke. 1993;24:509 (Abstract).
-
(1993)
Stroke
, vol.24
, pp. 509
-
-
Stump, D.A.1
Tegeler, C.H.2
Rogers, A.T.3
-
70
-
-
76349095980
-
Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: A randomized controlled trial
-
Medline. doi:10.1093/eurheartj/ehp178
-
Gerriets T, Schwarz N, Sammer G, et al. Protecting the brain from gaseous and solid micro-emboli during coronary artery bypass grafting: a randomized controlled trial. Eur Heart J. 2010;31:360-368. Medline. doi:10.1093/eurheartj/ehp178
-
(2010)
Eur Heart J
, vol.31
, pp. 360-368
-
-
Gerriets, T.1
Schwarz, N.2
Sammer, G.3
-
71
-
-
0015606577
-
The ultrastructural morphology of air embolism: Platelet adhesion to the interface and endothelial damage
-
Medline
-
Warren BA, Philip RB, Inwood MJ. The ultrastructural morphology of air embolism: platelet adhesion to the interface and endothelial damage. Br J Exp Pathol. 1973;54:163-172. Medline.
-
(1973)
Br J Exp Pathol
, vol.54
, pp. 163-172
-
-
Warren, B.A.1
Philip, R.B.2
Inwood, M.J.3
-
72
-
-
0022401427
-
Value of intra-operative left ventricular microbubbles detected by transoesophageal two-dimensional echocardiography in predicting neurological outcome after cardiac operations
-
Medline. doi:10.1016/0002-9149(85)91134-8
-
Topol EJ, Humphrey LS, Borkon AM, et al. Value of intra-operative left ventricular microbubbles detected by transoesophageal two-dimensional echocardiography in predicting neurological outcome after cardiac operations. Am J Cardiol. 1985;56:773-775. Medline. doi:10.1016/0002-9149(85)91134-8
-
(1985)
Am J Cardiol
, vol.56
, pp. 773-775
-
-
Topol, E.J.1
Humphrey, L.S.2
Borkon, A.M.3
-
73
-
-
0035139647
-
Similar neurobehavioral outcome after valve or coronary artery operations despite differing carotid embolic counts
-
Medline. doi:10.1067/mtc.2001.111378
-
Neville MJ, Butterworth J, James RL, Hammon JW, Stump DA. Similar neurobehavioral outcome after valve or coronary artery operations despite differing carotid embolic counts. J Thorac Cardiovasc Surg. 2001;121:125-136. Medline. doi:10.1067/mtc.2001.111378
-
(2001)
J Thorac Cardiovasc Surg
, vol.121
, pp. 125-136
-
-
Neville, M.J.1
Butterworth, J.2
James, R.L.3
Hammon, J.W.4
Stump, D.A.5
-
74
-
-
0027328234
-
Brain swelling in first hour after coronary artery bypass surgery
-
Medline. doi:10.1016/0140-6736(93)91412-F
-
Harris DN, Bailey SM, Smith PL, Taylor KM, Oatridge A, Bydder GM. Brain swelling in first hour after coronary artery bypass surgery. Lancet. 1993;342:586-587. Medline. doi:10.1016/0140-6736(93)91412-F
-
(1993)
Lancet
, vol.342
, pp. 586-587
-
-
Harris, D.N.1
Bailey, S.M.2
Smith, P.L.3
Taylor, K.M.4
Oatridge, A.5
Bydder, G.M.6
-
75
-
-
0026794981
-
Cardiopulmonary bypass and the blood-brain barrier. An experimental study
-
Gillinov AM, Davis EA, Curtis WE, et al. Cardiopulmonary bypass and the blood-brain barrier. An experimental study. J Thorac Cardiovasc Surg. 1992;104:1110-1115.
-
(1992)
J Thorac Cardiovasc Surg
, vol.104
, pp. 1110-1115
-
-
Gillinov, A.M.1
Davis, E.A.2
Curtis, W.E.3
-
76
-
-
0031788912
-
Impaired clearance of emboli (washout) is an important link between hypoperfusion, embolism, and ischemic stroke
-
Medline. doi:10.1001/archneur.55.11.1475
-
Caplan LR, Hennerici M. Impaired clearance of emboli (washout) is an important link between hypoperfusion, embolism, and ischemic stroke. Arch Neurol. 1998;55:1475-1482. Medline. doi:10.1001/archneur.55.11.1475
-
(1998)
Arch Neurol
, vol.55
, pp. 1475-1482
-
-
Caplan, L.R.1
Hennerici, M.2
-
77
-
-
0036081633
-
Transcranial Doppler characteristics of different embolic materials during in-vivo testing
-
Medline
-
Rodriguez RA, Giachino A, Hosking M, Nathan HJ. Transcranial Doppler characteristics of different embolic materials during in-vivo testing. J Neuroimaging. 2002;12:259-266. Medline.
-
(2002)
J Neuroimaging
, vol.12
, pp. 259-266
-
-
Rodriguez, R.A.1
Giachino, A.2
Hosking, M.3
Nathan, H.J.4
-
78
-
-
0028049036
-
Clinical relevance of in-traoperative embolization detected by transcranial Doppler ultrasonography during carotid endarterectomy: A prospective study of 100 patients
-
Medline. doi:10.1002/bjs.1800811009
-
Gaunt ME, Martin PJ, Smith JL, et al. Clinical relevance of in-traoperative embolization detected by transcranial Doppler ultrasonography during carotid endarterectomy: a prospective study of 100 patients. Br J Surg. 1994;81:1435-1439. Medline. doi:10.1002/bjs.1800811009
-
(1994)
Br J Surg
, vol.81
, pp. 1435-1439
-
-
Gaunt, M.E.1
Martin, P.J.2
Smith, J.L.3
-
79
-
-
64849099938
-
Emboli occurrence during coronary artery bypass surgery: The influence of a new method of perfusionist blood sampling
-
Medline. doi:10.1177/0267659109103390
-
Sauren L, Mooren E, Severdija E, Weerwind P, Maessen J. Emboli occurrence during coronary artery bypass surgery: the influence of a new method of perfusionist blood sampling. Perfusion. 2008;23:261-265. Medline. doi:10.1177/0267659109103390
-
(2008)
Perfusion
, vol.23
, pp. 261-265
-
-
Sauren, L.1
Mooren, E.2
Severdija, E.3
Weerwind, P.4
Maessen, J.5
-
80
-
-
38449091286
-
Preventing gaseous microemboli during blood sampling and drug administration: An in vitro investigation
-
Myers GJ. Preventing gaseous microemboli during blood sampling and drug administration: an in vitro investigation. J Extra Corpor Technol. 2007;39:192-198.
-
(2007)
J Extra Corpor Technol
, vol.39
, pp. 192-198
-
-
Myers, G.J.1
-
81
-
-
0017748965
-
Cerebral protection during open-heart surgery
-
Medline. doi:10.1136/thx.32.5.525
-
Aberg T, Kihlgren M. Cerebral protection during open-heart surgery. Thorax. 1977;32:525-533. Medline. doi:10.1136/thx.32.5.525
-
(1977)
Thorax
, vol.32
, pp. 525-533
-
-
Aberg, T.1
Kihlgren, M.2
-
82
-
-
0023933573
-
The effect of arterial filtration on reduction of gaseous microemboli in the middle cerebral artery during cardiopulmonary bypass
-
Medline. doi:10.1016/ S0003-4975(10)64768-6
-
Padayachee TS, Parsons S, Theobold R, et al. The effect of arterial filtration on reduction of gaseous microemboli in the middle cerebral artery during cardiopulmonary bypass. Ann Thorac Surg. 1988;45:647-649. Medline. doi:10.1016/ S0003-4975(10)64768-6
-
(1988)
Ann Thorac Surg
, vol.45
, pp. 647-649
-
-
Padayachee, T.S.1
Parsons, S.2
Theobold, R.3
-
83
-
-
41949116693
-
Arterial line filters ranked for gaseous microemboli separation performance: An in-vitro study
-
Riley JB. Arterial line filters ranked for gaseous microemboli separation performance: an in-vitro study. J Extra Corpor Technol. 2008;40:21-26.
-
(2008)
J Extra Corpor Technol
, vol.40
, pp. 21-26
-
-
Riley, J.B.1
-
84
-
-
55949088780
-
Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children
-
Medline. doi:10.1097/MAT.0b013e3181857e6a
-
Win KN, Wang S, Undar A. Microemboli generation, detection and characterization during CPB procedures in neonates, infants, and small children. ASAIO J. 2008;54:486-490. Medline. doi:10.1097/MAT.0b013e3181857e6a
-
(2008)
ASAIO J
, vol.54
, pp. 486-490
-
-
Win, K.N.1
Wang, S.2
Undar, A.3
-
85
-
-
51149120650
-
Stolen blood flow: The effect of an open arterial filter purge line in a simulated neonatal CPB model
-
Medline. doi:10.1097/MAT.0b013e31817e5ba6
-
Wang S, Miller A, Myers JL, Undar A. "Stolen" blood flow: The effect of an open arterial filter purge line in a simulated neonatal CPB model. ASAIO J. 2008;54:432-435. Medline. doi:10.1097/MAT.0b013e31817e5ba6
-
(2008)
ASAIO J
, vol.54
, pp. 432-435
-
-
Wang, S.1
Miller, A.2
Myers, J.L.3
Undar, A.4
-
86
-
-
76149129039
-
A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators
-
Medline. doi:10.1177/0267659109358206
-
Jirschik M, Keyl C, Beyersdorf F. A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators. Perfusion. 2009;24:423-427. Medline. doi:10.1177/0267659109358206
-
(2009)
Perfusion
, vol.24
, pp. 423-427
-
-
Jirschik, M.1
Keyl, C.2
Beyersdorf, F.3
-
87
-
-
0031808588
-
Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of air removal capabilities of neonatal membrane oxygenators
-
De Somer F, Dierickx P, Dujardin D, Verdonck P, Van Nooten G. Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of air removal capabilities of neonatal membrane oxygenators. Perfusion. 1998;13:157-163.
-
(1998)
Perfusion
, vol.13
, pp. 157-163
-
-
de Somer, F.1
Dierickx, P.2
Dujardin, D.3
Verdonck, P.4
van Nooten, G.5
-
88
-
-
0036306344
-
In vivo uptake and elimination of isoflurane by different membrane oxygenators during cardiopulmonary bypass
-
Medline. doi:10.1097/00000542-200207000-00019
-
Wiesenack C, Wiesner G, Keyl C, et al. In vivo uptake and elimination of isoflurane by different membrane oxygenators during cardiopulmonary bypass. Anesthesiology. 2002;97:133-138. Medline. doi:10.1097/00000542-200207000-00019
-
(2002)
Anesthesiology
, vol.97
, pp. 133-138
-
-
Wiesenack, C.1
Wiesner, G.2
Keyl, C.3
-
89
-
-
10744234020
-
The dynamic air bubble trap reduces cerebral microembolism during cardiopulmonary bypass
-
Medline. doi:10.1016/S0022-5223(03)00603-2
-
Schoenburg M, Kraus B, Muehling A, et al. The dynamic air bubble trap reduces cerebral microembolism during cardiopulmonary bypass. J Thorac Cardiovasc Surg. 2003;126:1455-1460. Medline. doi:10.1016/S0022-5223(03)00603-2
-
(2003)
J Thorac Cardiovasc Surg
, vol.126
, pp. 1455-1460
-
-
Schoenburg, M.1
Kraus, B.2
Muehling, A.3
-
90
-
-
22144448873
-
Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery
-
Medline. doi:10.1191/0267659105pf813oa
-
Perthel M, Kseibi S, Bendisch A, Laas J. Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery. Perfusion. 2005;20:151-156. Medline. doi:10.1191/0267659105pf813oa
-
(2005)
Perfusion
, vol.20
, pp. 151-156
-
-
Perthel, M.1
Kseibi, S.2
Bendisch, A.3
Laas, J.4
-
91
-
-
0036898954
-
Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass?
-
Medline. doi:10.1016/ S0003-4975(02)04081-X
-
Jones TJ, Deal DD, Vernon JC, Blackburn N, Stump DA. Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass? Ann Thorac Surg. 2002;74:2132-2137. Medline. doi:10.1016/ S0003-4975(02)04081-X
-
(2002)
Ann Thorac Surg
, vol.74
, pp. 2132-2137
-
-
Jones, T.J.1
Deal, D.D.2
Vernon, J.C.3
Blackburn, N.4
Stump, D.A.5
-
92
-
-
75649112339
-
Does CO(2) flushing of the empty CPB circuit decrease the number of gaseous emboli in the prime?
-
Medline. doi:10.1177/0267659109350241
-
Nyman J, Rundby C, Svenarud P, van der Linden J. Does CO(2) flushing of the empty CPB circuit decrease the number of gaseous emboli in the prime? Perfusion. 2009;24:249-255. Medline. doi:10.1177/0267659109350241
-
(2009)
Perfusion
, vol.24
, pp. 249-255
-
-
Nyman, J.1
Rundby, C.2
Svenarud, P.3
van der Linden, J.4
-
93
-
-
79958118352
-
An in vitro study of the effectiveness of carbon dioxide flushing of arterial line filters
-
Beckman RR, Gisner C, Evans E. An in vitro study of the effectiveness of carbon dioxide flushing of arterial line filters. J Extra Corpor Technol. 2009;41:161-165.
-
(2009)
J Extra Corpor Technol
, vol.41
, pp. 161-165
-
-
Beckman, R.R.1
Gisner, C.2
Evans, E.3
-
94
-
-
10144229393
-
Intracardiac air clearing in valvular surgery guided by transesophageal echocardiography
-
Dalmas JP, Eker A, Girard C, et al. Intracardiac air clearing in valvular surgery guided by transesophageal echocardiography. J Heart Valve Dis. 1996;5:553-557.
-
(1996)
J Heart Valve Dis
, vol.5
, pp. 553-557
-
-
Dalmas, J.P.1
Eker, A.2
Girard, C.3
-
95
-
-
0029111518
-
Intraoperative echo-cardiographic study of air embolism during cardiac operations
-
Medline. doi:10.1016/0003-4975(95)00577-8
-
Tingleff J, Joyce FS, Pettersson G. Intraoperative echo-cardiographic study of air embolism during cardiac operations. Ann Thorac Surg. 1995;60:673-677. Medline. doi:10.1016/0003-4975(95)00577-8
-
(1995)
Ann Thorac Surg
, vol.60
, pp. 673-677
-
-
Tingleff, J.1
Joyce, F.S.2
Pettersson, G.3
-
96
-
-
67649406069
-
A new de-airing technique that reduces systemic microemboli during open surgery: A prospective controlled study
-
Medline. doi:10.1016/j.jtcvs.2009.02.037
-
Al-Rashidi F, Blomquist S, Höglund P, Meurling C, Roijer A, Koul B. A new de-airing technique that reduces systemic microemboli during open surgery: a prospective controlled study. J Thorac Cardiovasc Surg. 2009;138:157-162. Medline. doi:10.1016/j.jtcvs.2009.02.037
-
(2009)
J Thorac Cardiovasc Surg
, vol.138
, pp. 157-162
-
-
Al-Rashidi, F.1
Blomquist, S.2
Höglund, P.3
Meurling, C.4
Roijer, A.5
Koul, B.6
-
97
-
-
0014261173
-
Carbon dioxide in the prevention of air embolism during open-heart surgery
-
Medline. doi:10.1136/thx.23.2.194
-
Ng WS, Rosen M. Carbon dioxide in the prevention of air embolism during open-heart surgery. Thorax. 1968;23:194-196. Medline. doi:10.1136/thx.23.2.194
-
(1968)
Thorax
, vol.23
, pp. 194-196
-
-
Ng, W.S.1
Rosen, M.2
-
98
-
-
0242551688
-
Carbon dioxide field flooding versus mechanical deairing during open-heart surgery: A prospective randomized controlled trial
-
Medline. doi:10.1191/0267659103pf671oa
-
Kalpokas MV, Nixon IK, Kluger R, Beilby DS, Silbert BS. Carbon dioxide field flooding versus mechanical deairing during open-heart surgery: a prospective randomized controlled trial. Perfusion. 2003;18:291-294. Medline. doi:10.1191/0267659103pf671oa
-
(2003)
Perfusion
, vol.18
, pp. 291-294
-
-
Kalpokas, M.V.1
Nixon, I.K.2
Kluger, R.3
Beilby, D.S.4
Silbert, B.S.5
-
99
-
-
0000104760
-
Injection of air and of carbon dioxide into a pulmonary vein
-
Medline. doi:10.1097/00000658-194008000-00004
-
Moore RM, Braselton CW Jr. Injection of air and of carbon dioxide into a pulmonary vein. Ann Surg. 1940;112:212-218. Medline. doi:10.1097/00000658-194008000-00004
-
(1940)
Ann Surg
, vol.112
, pp. 212-218
-
-
Moore, R.M.1
Braselton Jr., C.W.2
-
100
-
-
68049106115
-
Does the use of carbon dioxide field flooding during heart valve surgery prevents postoperative cerebrovascular complications?
-
Medline. doi:10.1510/icvts.2009.206177
-
Giordano S, Biancari F. Does the use of carbon dioxide field flooding during heart valve surgery prevents postoperative cerebrovascular complications? Interact Cardiovasc Thorac Surg. 2009;9:323-326. Medline. doi:10.1510/icvts.2009.206177
-
(2009)
Interact Cardiovasc Thorac Surg
, vol.9
, pp. 323-326
-
-
Giordano, S.1
Biancari, F.2
|