-
1
-
-
67651150035
-
The epidemiology of bearing surface usage in total hip arthroplasty in the United States
-
Bozic KJ, Kurtz S, Lau E, et al. 2009. The epidemiology of bearing surface usage in total hip arthroplasty in the United States. J Bone Joint Surg Am 91: 1614-1620.
-
(2009)
J Bone Joint Surg Am
, vol.91
, pp. 1614-1620
-
-
Bozic, K.J.1
Kurtz, S.2
Lau, E.3
-
2
-
-
78049474392
-
Metal-on-metal hip arthroplasty in patients thirty years of age or younger
-
Girard J, Bocquet D, Autissier G, et al. 2010. Metal-on-metal hip arthroplasty in patients thirty years of age or younger. J Bone Joint Surg Am 92: 2419-2426.
-
(2010)
J Bone Joint Surg Am
, vol.92
, pp. 2419-2426
-
-
Girard, J.1
Bocquet, D.2
Autissier, G.3
-
3
-
-
79959546862
-
Survival of hard-on-hard bearings in total hip arthroplasty: A systematic review
-
et al. [Epub ahead of print].
-
Zywiel MG, Sayeed SA, Johnson AJ, et al. 2011. Survival of hard-on-hard bearings in total hip arthroplasty: A systematic review. Clin Orthop Relat Res [Epub ahead of print].
-
(2011)
Clin Orthop Relat Res
-
-
Zywiel, M.G.1
Sayeed, S.A.2
Johnson, A.J.3
-
4
-
-
0029809718
-
Metal on metal bearings in hip arthroplasty
-
Amstutz HC, Grigoris P,. 1996. Metal on metal bearings in hip arthroplasty. Clin Orthop Relat Res 329 (Suppl): S11-S34.
-
(1996)
Clin Orthop Relat Res
, vol.329
, Issue.SUPPL
-
-
Amstutz, H.C.1
Grigoris, P.2
-
5
-
-
53849111555
-
Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement
-
De Haan R, Pattyn C, Gill HS, et al. 2008. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br 90: 1291-1297.
-
(2008)
J Bone Joint Surg Br
, vol.90
, pp. 1291-1297
-
-
De Haan, R.1
Pattyn, C.2
Gill, H.S.3
-
6
-
-
77955582182
-
Reduced articular surface of one-piece cups: A cause of runaway wear and early failure
-
Griffin WL, Nanson CJ, Springer BD, et al. 2010. Reduced articular surface of one-piece cups: A cause of runaway wear and early failure. Clin Orthop Relat Res 468: 2328-2332.
-
(2010)
Clin Orthop Relat Res
, vol.468
, pp. 2328-2332
-
-
Griffin, W.L.1
Nanson, C.J.2
Springer, B.D.3
-
7
-
-
77957907908
-
Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty
-
Hosman AH, van der Mei HC, Bulstra SK, et al. 2010. Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty. Acta Orthop 81: 526-534.
-
(2010)
Acta Orthop
, vol.81
, pp. 526-534
-
-
Hosman, A.H.1
Van Der Mei, H.C.2
Bulstra, S.K.3
-
9
-
-
47549111326
-
Pseudotumours associated with metal-on-metal hip resurfacings
-
DOI 10.1302/0301-620X.90B7.20213
-
Pandit H, Glyn-Jones S, McLardy-Smith P, et al. 2008. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br 90: 847-851. (Pubitemid 352009768)
-
(2008)
Journal of Bone and Joint Surgery - Series B
, vol.90
, Issue.7
, pp. 847-851
-
-
Pandit, H.1
Glyn-Jones, S.2
McLardy-Smith, P.3
Gundle, R.4
Whitwell, D.5
Gibbons, C.L.M.6
Ostlere, S.7
Athanasou, N.8
Gill, H.S.9
Murray, D.W.10
-
10
-
-
16544389414
-
Contact mechanics analysis of metal-on-metal hip resurfacing prostheses
-
Udofia IJ, Yew A, Jin ZM,. 2004. Contact mechanics analysis of metal-on-metal hip resurfacing prostheses. Proc Inst Mech Eng H 218: 293-305.
-
(2004)
Proc Inst Mech Eng H
, vol.218
, pp. 293-305
-
-
Udofia, I.J.1
Yew, A.2
Jin, Z.M.3
-
11
-
-
35848961039
-
Orientation and wear of the acetabular component in third generation alumina-on-alumina ceramic bearings: An analysis of 33 retrievals
-
DOI 10.1302/0301-620X.89B9.19282
-
Lusty PJ, Watson A, Tuke MA, et al. 2007. Wear and acetabular component orientation in third generation alumina-on-alumina ceramic bearings: An analysis of 33 retrievals. J Bone Joint Surg Br 89: 1158-1164. (Pubitemid 350057952)
-
(2007)
Journal of Bone and Joint Surgery - Series B
, vol.89
, Issue.9
, pp. 1158-1164
-
-
Lusty, P.J.1
Watson, A.2
Tuke, M.A.3
Walter, W.L.4
Walter, W.K.5
Zicat, B.6
-
12
-
-
9644279533
-
Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty
-
DOI 10.1016/j.arth.2004.09.003, PII S0883540304004887
-
Brodner W, Grübl A, Jankovsky R, et al. 2004. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty 19: 66-70. (Pubitemid 39575831)
-
(2004)
Journal of Arthroplasty
, vol.19
, Issue.8 SUPPL.
, pp. 66-70
-
-
Brodner, W.1
Grubl, A.2
Jankovsky, R.3
Meisinger, V.4
Lehr, S.5
Gottsauner-Wolf, F.6
-
13
-
-
53649099528
-
The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty
-
Khan M, Kuiper JH, Richardson J,. 2008. The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Br 90: 1152-1157.
-
(2008)
J Bone Joint Surg Br
, vol.90
, pp. 1152-1157
-
-
Khan, M.1
Kuiper, J.H.2
Richardson, J.3
-
14
-
-
49849095334
-
Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position
-
Williams S, Leslie I, Isaac G, et al. 2008. Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position. J Bone Joint Surg Am 90 (Supp3): 111-117.
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.SUPPL.3
, pp. 111-117
-
-
Williams, S.1
Leslie, I.2
Isaac, G.3
-
15
-
-
75649095676
-
Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear
-
Langton D, Jameson S, Joyce T, et al. 2010. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear. J Bone Joint Surg Br 92: 38-46.
-
(2010)
J Bone Joint Surg Br
, vol.92
, pp. 38-46
-
-
Langton, D.1
Jameson, S.2
Joyce, T.3
-
16
-
-
79959569090
-
Femoral head size does not affect ion values in metal-on-metal total hips
-
Bernstein M, Walsh A, Petit A, et al. Femoral head size does not affect ion values in metal-on-metal total hips. Clin Orthop Relat Res 469: 1642-1650.
-
Clin Orthop Relat Res
, vol.469
, pp. 1642-1650
-
-
Bernstein, M.1
Walsh, A.2
Petit, A.3
-
17
-
-
52449102219
-
Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements? An in vitro study
-
Leslie I, Williams S, Brown C, et al. 2008. Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements? An in vitro study. J Biomed Mater Res, Part B 87B: 163-172.
-
(2008)
J Biomed Mater Res, Part B
, vol.87 B
, pp. 163-172
-
-
Leslie, I.1
Williams, S.2
Brown, C.3
-
18
-
-
69249208803
-
High cup angle and microseparation increase the wear of hip surface replacements
-
Leslie IJ, Williams S, Isaac G, et al. 2009. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthop Relat Res 467: 2259-2265.
-
(2009)
Clin Orthop Relat Res
, vol.467
, pp. 2259-2265
-
-
Leslie, I.J.1
Williams, S.2
Isaac, G.3
-
19
-
-
78649658341
-
Effect of cup inclination angle during microseparation and rim loading on the wear of Biolox Delta ceramic-on-ceramic total hip replacement
-
Al-Hajjar M, Leslie IJ, Tipper J, et al. 2010. Effect of cup inclination angle during microseparation and rim loading on the wear of Biolox Delta ceramic-on-ceramic total hip replacement. J Biomed Mater Res, Part B 95: 263-268.
-
(2010)
J Biomed Mater Res, Part B
, vol.95
, pp. 263-268
-
-
Al-Hajjar, M.1
Leslie, I.J.2
Tipper, J.3
-
20
-
-
0036054006
-
Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements
-
DOI 10.1243/095441102321032193
-
Mak MM, Besong AA, Jin ZM, et al. 2002. Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proc Inst Mech Eng H 216: 403-408. (Pubitemid 35465814)
-
(2002)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.216
, Issue.6
, pp. 403-408
-
-
Mak, M.M.1
Besong, A.A.2
Jin, Z.M.3
Fisher, J.4
-
21
-
-
78650003014
-
Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses
-
Mak M, Jin Z, Fisher J, et al. 2011. Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses. J Arthroplasty 26: 131-136.
-
(2011)
J Arthroplasty
, vol.26
, pp. 131-136
-
-
Mak, M.1
Jin, Z.2
Fisher, J.3
-
22
-
-
78951494563
-
Hard-on-hard total hip impingement causes extreme contact stress concentrations
-
Elkins JM, O'Brien MK, Stroud NJ, et al. 2011. Hard-on-hard total hip impingement causes extreme contact stress concentrations. Clin Orthop Relat Res 469: 454-463.
-
(2011)
Clin Orthop Relat Res
, vol.469
, pp. 454-463
-
-
Elkins, J.M.1
O'Brien, M.K.2
Stroud, N.J.3
-
23
-
-
80053210594
-
The capsule's contribution to total hip construct stability-A finite element analysis
-
et al. DOI: 10.1002/jor.21435.
-
Elkins JM, Stroud NJ, Rudert MJ, et al. 2011. The capsule's contribution to total hip construct stability-A finite element analysis. J Orthop Res DOI: 10.1002/jor.21435.
-
(2011)
J Orthop Res
-
-
Elkins, J.M.1
Stroud, N.J.2
Rudert, M.J.3
-
24
-
-
33748299418
-
Approximate analytical model for Hertzian elliptical contact problems
-
DOI 10.1115/1.2197850
-
Antoine J, Visa C, Sauvey C, et al. 2006. Approximate analytical model for Hertzian elliptical contact problems. J Tribol 128: 660-664. (Pubitemid 44323603)
-
(2006)
Journal of Tribology
, vol.128
, Issue.3
, pp. 660-664
-
-
Antoine, J.-F.1
Visa, C.2
Sauvey, C.3
Abba, G.4
-
25
-
-
0027479381
-
The definition and measurement of acetabular orientation
-
Murray D,. 1993. The definition and measurement of acetabular orientation. J Bone Joint Surg Br 75: 228-232. (Pubitemid 23087178)
-
(1993)
Journal of Bone and Joint Surgery - Series B
, vol.75
, Issue.2
, pp. 228-232
-
-
Murray, D.W.1
-
26
-
-
34247623494
-
Friction of total hip replacements with different bearings and loading conditions
-
DOI 10.1002/jbm.b.30691
-
Brockett C, Williams S, Jin Z, et al. 2007. Friction of total hip replacements with different bearings and loading conditions. J Biomed Mater Res, Part B 81: 508-515. (Pubitemid 46685121)
-
(2007)
Journal of Biomedical Materials Research - Part B Applied Biomaterials
, vol.81
, Issue.2
, pp. 508-515
-
-
Brockett, C.1
Williams, S.2
Jin, Z.3
Isaac, G.4
Fisher, J.5
-
27
-
-
16844378530
-
Activity-dependence of the safe zone for impingement versus dislocation avoidance
-
DOI 10.1016/j.medengphy.2004.09.004, Current Status of Orthopaedic Biomechanics
-
Pedersen DR, Callaghan JJ, Brown TD,. 2005. Activity-dependence of the "safe zone" for impingement versus dislocation avoidance. Med Eng Phys 27: 323-328. (Pubitemid 40488773)
-
(2005)
Medical Engineering and Physics
, vol.27
, Issue.4
, pp. 323-328
-
-
Pedersen, D.R.1
Callaghan, J.J.2
Brown, T.D.3
-
28
-
-
0037398768
-
Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation
-
DOI 10.1016/S0021-9290(02)00232-4, PII S0021929002002324
-
Nadzadi ME, Pedersen DR, Yack HJ, et al. 2003. Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech 36: 577-591. (Pubitemid 36207588)
-
(2003)
Journal of Biomechanics
, vol.36
, Issue.4
, pp. 577-591
-
-
Nadzadi, M.E.1
Pedersen, D.R.2
Yack, H.J.3
Callaghan, J.J.4
Brown, T.D.5
-
29
-
-
13344270633
-
Contact and rubbing of flat surfaces
-
Archard J,. 1953. Contact and rubbing of flat surfaces. J Appl Phys 24: 981-988.
-
(1953)
J Appl Phys
, vol.24
, pp. 981-988
-
-
Archard, J.1
-
30
-
-
83855163636
-
Standard specification for cobalt-28 chromium-6 molybdenum alloy forgings for surgical implants
-
ASTM F-799-95.
-
ASTM F-799-95. 1995. Standard specification for cobalt-28 chromium-6 molybdenum alloy forgings for surgical implants. Am Soc Test Mater 13.01: 230-232.
-
(1995)
Am Soc Test Mater
, vol.1301
, pp. 230-232
-
-
-
31
-
-
79959562687
-
Does acetabular inclination angle affect survivorship of alumina-ceramic articulations?
-
Johansson HR, Johnson AJ, Zywiel MG, et al. Does acetabular inclination angle affect survivorship of alumina-ceramic articulations? Clin Orthop Relat Res 469: 1560-1566.
-
Clin Orthop Relat Res
, vol.469
, pp. 1560-1566
-
-
Johansson, H.R.1
Johnson, A.J.2
Zywiel, M.G.3
-
32
-
-
2642584746
-
Edge loading in third generation alumina ceramic-on-ceramic bearings: Stripe wear
-
DOI 10.1016/j.arth.2003.09.018, PII S088354030400066X
-
Walter WL, Insley GM, Walter WK, et al. 2004. Edge loading in third generation alumina ceramic-on-ceramic bearings: Stripe wear. J Arthroplasty 19: 402-413. (Pubitemid 38725921)
-
(2004)
Journal of Arthroplasty
, vol.19
, Issue.4
, pp. 402-413
-
-
Walter, W.L.1
Insley, G.M.2
Walter, W.K.3
Tuke, M.A.4
-
33
-
-
0035209674
-
Experimental and computational simulation of total hip arthroplasty dislocation
-
DOI 10.1016/S0030-5898(05)70226-1
-
Scifert CF, Noble PC, Brown TD, et al. 2001. Experimental and computational simulation of total hip arthroplasty dislocation. Orthop Clin North Am 32: 553-567, vii. (Pubitemid 33136272)
-
(2001)
Orthopedic Clinics of North America
, vol.32
, Issue.4
, pp. 553-567
-
-
Scifert, C.F.1
Noble, P.C.2
Brown, T.D.3
Bartz, R.L.4
Kadakia, N.5
Sugano, N.6
Johnston, R.C.7
Pedersen, D.R.8
Callaghan, J.J.9
-
35
-
-
74249087326
-
Mathematical evaluation of jumping distance in total hip arthroplasty: Influence of abduction angle, femoral head offset, and head diameter
-
Sariali E, Lazennec JY, Khiami F, et al. 2009. Mathematical evaluation of jumping distance in total hip arthroplasty: Influence of abduction angle, femoral head offset, and head diameter. Acta Orthop 80: 277-282.
-
(2009)
Acta Orthop
, vol.80
, pp. 277-282
-
-
Sariali, E.1
Lazennec, J.Y.2
Khiami, F.3
-
36
-
-
27544453008
-
Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty
-
DOI 10.2106/JBJS.D.02860
-
Berry DJ, von Knoch M, Schleck CD, et al. 2005. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 87: 2456-2463. (Pubitemid 41546376)
-
(2005)
Journal of Bone and Joint Surgery - Series A
, vol.87
, Issue.11
, pp. 2456-2463
-
-
Berry, D.J.1
Von Knoch, M.2
Schleck, C.D.3
Harmsen, W.S.4
|