메뉴 건너뛰기




Volumn 30, Issue 2, 2012, Pages 169-177

Edge-loading severity as a function of cup lip radius in metal-on-metal total hips-A finite element analysis

Author keywords

finite element; metal on metal; subluxation; total hip arthroplasty; wear

Indexed keywords

METAL; POLYETHYLENE;

EID: 83855162881     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.21524     Document Type: Article
Times cited : (35)

References (36)
  • 1
    • 67651150035 scopus 로고    scopus 로고
    • The epidemiology of bearing surface usage in total hip arthroplasty in the United States
    • Bozic KJ, Kurtz S, Lau E, et al. 2009. The epidemiology of bearing surface usage in total hip arthroplasty in the United States. J Bone Joint Surg Am 91: 1614-1620.
    • (2009) J Bone Joint Surg Am , vol.91 , pp. 1614-1620
    • Bozic, K.J.1    Kurtz, S.2    Lau, E.3
  • 2
    • 78049474392 scopus 로고    scopus 로고
    • Metal-on-metal hip arthroplasty in patients thirty years of age or younger
    • Girard J, Bocquet D, Autissier G, et al. 2010. Metal-on-metal hip arthroplasty in patients thirty years of age or younger. J Bone Joint Surg Am 92: 2419-2426.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 2419-2426
    • Girard, J.1    Bocquet, D.2    Autissier, G.3
  • 3
    • 79959546862 scopus 로고    scopus 로고
    • Survival of hard-on-hard bearings in total hip arthroplasty: A systematic review
    • et al. [Epub ahead of print].
    • Zywiel MG, Sayeed SA, Johnson AJ, et al. 2011. Survival of hard-on-hard bearings in total hip arthroplasty: A systematic review. Clin Orthop Relat Res [Epub ahead of print].
    • (2011) Clin Orthop Relat Res
    • Zywiel, M.G.1    Sayeed, S.A.2    Johnson, A.J.3
  • 4
    • 0029809718 scopus 로고    scopus 로고
    • Metal on metal bearings in hip arthroplasty
    • Amstutz HC, Grigoris P,. 1996. Metal on metal bearings in hip arthroplasty. Clin Orthop Relat Res 329 (Suppl): S11-S34.
    • (1996) Clin Orthop Relat Res , vol.329 , Issue.SUPPL
    • Amstutz, H.C.1    Grigoris, P.2
  • 5
    • 53849111555 scopus 로고    scopus 로고
    • Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement
    • De Haan R, Pattyn C, Gill HS, et al. 2008. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br 90: 1291-1297.
    • (2008) J Bone Joint Surg Br , vol.90 , pp. 1291-1297
    • De Haan, R.1    Pattyn, C.2    Gill, H.S.3
  • 6
    • 77955582182 scopus 로고    scopus 로고
    • Reduced articular surface of one-piece cups: A cause of runaway wear and early failure
    • Griffin WL, Nanson CJ, Springer BD, et al. 2010. Reduced articular surface of one-piece cups: A cause of runaway wear and early failure. Clin Orthop Relat Res 468: 2328-2332.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 2328-2332
    • Griffin, W.L.1    Nanson, C.J.2    Springer, B.D.3
  • 7
    • 77957907908 scopus 로고    scopus 로고
    • Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty
    • Hosman AH, van der Mei HC, Bulstra SK, et al. 2010. Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty. Acta Orthop 81: 526-534.
    • (2010) Acta Orthop , vol.81 , pp. 526-534
    • Hosman, A.H.1    Van Der Mei, H.C.2    Bulstra, S.K.3
  • 10
    • 16544389414 scopus 로고    scopus 로고
    • Contact mechanics analysis of metal-on-metal hip resurfacing prostheses
    • Udofia IJ, Yew A, Jin ZM,. 2004. Contact mechanics analysis of metal-on-metal hip resurfacing prostheses. Proc Inst Mech Eng H 218: 293-305.
    • (2004) Proc Inst Mech Eng H , vol.218 , pp. 293-305
    • Udofia, I.J.1    Yew, A.2    Jin, Z.M.3
  • 11
    • 35848961039 scopus 로고    scopus 로고
    • Orientation and wear of the acetabular component in third generation alumina-on-alumina ceramic bearings: An analysis of 33 retrievals
    • DOI 10.1302/0301-620X.89B9.19282
    • Lusty PJ, Watson A, Tuke MA, et al. 2007. Wear and acetabular component orientation in third generation alumina-on-alumina ceramic bearings: An analysis of 33 retrievals. J Bone Joint Surg Br 89: 1158-1164. (Pubitemid 350057952)
    • (2007) Journal of Bone and Joint Surgery - Series B , vol.89 , Issue.9 , pp. 1158-1164
    • Lusty, P.J.1    Watson, A.2    Tuke, M.A.3    Walter, W.L.4    Walter, W.K.5    Zicat, B.6
  • 12
    • 9644279533 scopus 로고    scopus 로고
    • Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty
    • DOI 10.1016/j.arth.2004.09.003, PII S0883540304004887
    • Brodner W, Grübl A, Jankovsky R, et al. 2004. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty 19: 66-70. (Pubitemid 39575831)
    • (2004) Journal of Arthroplasty , vol.19 , Issue.8 SUPPL. , pp. 66-70
    • Brodner, W.1    Grubl, A.2    Jankovsky, R.3    Meisinger, V.4    Lehr, S.5    Gottsauner-Wolf, F.6
  • 13
    • 53649099528 scopus 로고    scopus 로고
    • The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty
    • Khan M, Kuiper JH, Richardson J,. 2008. The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Br 90: 1152-1157.
    • (2008) J Bone Joint Surg Br , vol.90 , pp. 1152-1157
    • Khan, M.1    Kuiper, J.H.2    Richardson, J.3
  • 14
    • 49849095334 scopus 로고    scopus 로고
    • Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position
    • Williams S, Leslie I, Isaac G, et al. 2008. Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position. J Bone Joint Surg Am 90 (Supp3): 111-117.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.SUPPL.3 , pp. 111-117
    • Williams, S.1    Leslie, I.2    Isaac, G.3
  • 15
    • 75649095676 scopus 로고    scopus 로고
    • Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear
    • Langton D, Jameson S, Joyce T, et al. 2010. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear. J Bone Joint Surg Br 92: 38-46.
    • (2010) J Bone Joint Surg Br , vol.92 , pp. 38-46
    • Langton, D.1    Jameson, S.2    Joyce, T.3
  • 16
    • 79959569090 scopus 로고    scopus 로고
    • Femoral head size does not affect ion values in metal-on-metal total hips
    • Bernstein M, Walsh A, Petit A, et al. Femoral head size does not affect ion values in metal-on-metal total hips. Clin Orthop Relat Res 469: 1642-1650.
    • Clin Orthop Relat Res , vol.469 , pp. 1642-1650
    • Bernstein, M.1    Walsh, A.2    Petit, A.3
  • 17
    • 52449102219 scopus 로고    scopus 로고
    • Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements? An in vitro study
    • Leslie I, Williams S, Brown C, et al. 2008. Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements? An in vitro study. J Biomed Mater Res, Part B 87B: 163-172.
    • (2008) J Biomed Mater Res, Part B , vol.87 B , pp. 163-172
    • Leslie, I.1    Williams, S.2    Brown, C.3
  • 18
    • 69249208803 scopus 로고    scopus 로고
    • High cup angle and microseparation increase the wear of hip surface replacements
    • Leslie IJ, Williams S, Isaac G, et al. 2009. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthop Relat Res 467: 2259-2265.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 2259-2265
    • Leslie, I.J.1    Williams, S.2    Isaac, G.3
  • 19
    • 78649658341 scopus 로고    scopus 로고
    • Effect of cup inclination angle during microseparation and rim loading on the wear of Biolox Delta ceramic-on-ceramic total hip replacement
    • Al-Hajjar M, Leslie IJ, Tipper J, et al. 2010. Effect of cup inclination angle during microseparation and rim loading on the wear of Biolox Delta ceramic-on-ceramic total hip replacement. J Biomed Mater Res, Part B 95: 263-268.
    • (2010) J Biomed Mater Res, Part B , vol.95 , pp. 263-268
    • Al-Hajjar, M.1    Leslie, I.J.2    Tipper, J.3
  • 21
    • 78650003014 scopus 로고    scopus 로고
    • Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses
    • Mak M, Jin Z, Fisher J, et al. 2011. Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses. J Arthroplasty 26: 131-136.
    • (2011) J Arthroplasty , vol.26 , pp. 131-136
    • Mak, M.1    Jin, Z.2    Fisher, J.3
  • 22
    • 78951494563 scopus 로고    scopus 로고
    • Hard-on-hard total hip impingement causes extreme contact stress concentrations
    • Elkins JM, O'Brien MK, Stroud NJ, et al. 2011. Hard-on-hard total hip impingement causes extreme contact stress concentrations. Clin Orthop Relat Res 469: 454-463.
    • (2011) Clin Orthop Relat Res , vol.469 , pp. 454-463
    • Elkins, J.M.1    O'Brien, M.K.2    Stroud, N.J.3
  • 23
    • 80053210594 scopus 로고    scopus 로고
    • The capsule's contribution to total hip construct stability-A finite element analysis
    • et al. DOI: 10.1002/jor.21435.
    • Elkins JM, Stroud NJ, Rudert MJ, et al. 2011. The capsule's contribution to total hip construct stability-A finite element analysis. J Orthop Res DOI: 10.1002/jor.21435.
    • (2011) J Orthop Res
    • Elkins, J.M.1    Stroud, N.J.2    Rudert, M.J.3
  • 24
    • 33748299418 scopus 로고    scopus 로고
    • Approximate analytical model for Hertzian elliptical contact problems
    • DOI 10.1115/1.2197850
    • Antoine J, Visa C, Sauvey C, et al. 2006. Approximate analytical model for Hertzian elliptical contact problems. J Tribol 128: 660-664. (Pubitemid 44323603)
    • (2006) Journal of Tribology , vol.128 , Issue.3 , pp. 660-664
    • Antoine, J.-F.1    Visa, C.2    Sauvey, C.3    Abba, G.4
  • 25
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • Murray D,. 1993. The definition and measurement of acetabular orientation. J Bone Joint Surg Br 75: 228-232. (Pubitemid 23087178)
    • (1993) Journal of Bone and Joint Surgery - Series B , vol.75 , Issue.2 , pp. 228-232
    • Murray, D.W.1
  • 27
    • 16844378530 scopus 로고    scopus 로고
    • Activity-dependence of the safe zone for impingement versus dislocation avoidance
    • DOI 10.1016/j.medengphy.2004.09.004, Current Status of Orthopaedic Biomechanics
    • Pedersen DR, Callaghan JJ, Brown TD,. 2005. Activity-dependence of the "safe zone" for impingement versus dislocation avoidance. Med Eng Phys 27: 323-328. (Pubitemid 40488773)
    • (2005) Medical Engineering and Physics , vol.27 , Issue.4 , pp. 323-328
    • Pedersen, D.R.1    Callaghan, J.J.2    Brown, T.D.3
  • 28
    • 0037398768 scopus 로고    scopus 로고
    • Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation
    • DOI 10.1016/S0021-9290(02)00232-4, PII S0021929002002324
    • Nadzadi ME, Pedersen DR, Yack HJ, et al. 2003. Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech 36: 577-591. (Pubitemid 36207588)
    • (2003) Journal of Biomechanics , vol.36 , Issue.4 , pp. 577-591
    • Nadzadi, M.E.1    Pedersen, D.R.2    Yack, H.J.3    Callaghan, J.J.4    Brown, T.D.5
  • 29
    • 13344270633 scopus 로고
    • Contact and rubbing of flat surfaces
    • Archard J,. 1953. Contact and rubbing of flat surfaces. J Appl Phys 24: 981-988.
    • (1953) J Appl Phys , vol.24 , pp. 981-988
    • Archard, J.1
  • 30
    • 83855163636 scopus 로고
    • Standard specification for cobalt-28 chromium-6 molybdenum alloy forgings for surgical implants
    • ASTM F-799-95.
    • ASTM F-799-95. 1995. Standard specification for cobalt-28 chromium-6 molybdenum alloy forgings for surgical implants. Am Soc Test Mater 13.01: 230-232.
    • (1995) Am Soc Test Mater , vol.1301 , pp. 230-232
  • 31
    • 79959562687 scopus 로고    scopus 로고
    • Does acetabular inclination angle affect survivorship of alumina-ceramic articulations?
    • Johansson HR, Johnson AJ, Zywiel MG, et al. Does acetabular inclination angle affect survivorship of alumina-ceramic articulations? Clin Orthop Relat Res 469: 1560-1566.
    • Clin Orthop Relat Res , vol.469 , pp. 1560-1566
    • Johansson, H.R.1    Johnson, A.J.2    Zywiel, M.G.3
  • 32
    • 2642584746 scopus 로고    scopus 로고
    • Edge loading in third generation alumina ceramic-on-ceramic bearings: Stripe wear
    • DOI 10.1016/j.arth.2003.09.018, PII S088354030400066X
    • Walter WL, Insley GM, Walter WK, et al. 2004. Edge loading in third generation alumina ceramic-on-ceramic bearings: Stripe wear. J Arthroplasty 19: 402-413. (Pubitemid 38725921)
    • (2004) Journal of Arthroplasty , vol.19 , Issue.4 , pp. 402-413
    • Walter, W.L.1    Insley, G.M.2    Walter, W.K.3    Tuke, M.A.4
  • 35
    • 74249087326 scopus 로고    scopus 로고
    • Mathematical evaluation of jumping distance in total hip arthroplasty: Influence of abduction angle, femoral head offset, and head diameter
    • Sariali E, Lazennec JY, Khiami F, et al. 2009. Mathematical evaluation of jumping distance in total hip arthroplasty: Influence of abduction angle, femoral head offset, and head diameter. Acta Orthop 80: 277-282.
    • (2009) Acta Orthop , vol.80 , pp. 277-282
    • Sariali, E.1    Lazennec, J.Y.2    Khiami, F.3
  • 36
    • 27544453008 scopus 로고    scopus 로고
    • Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty
    • DOI 10.2106/JBJS.D.02860
    • Berry DJ, von Knoch M, Schleck CD, et al. 2005. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 87: 2456-2463. (Pubitemid 41546376)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.11 , pp. 2456-2463
    • Berry, D.J.1    Von Knoch, M.2    Schleck, C.D.3    Harmsen, W.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.