Volumn 29, Issue 11, 2011, Pages 1642-1648

The capsule's contribution to total hip construct stability-A finite element analysis

Author keywords

finite element analysis; hip capsule; suture failure; total hip arthroplasty

Indexed keywords

ARTICLE; BIOMECHANICS; COMPUTER MODEL; FEMUR; FINITE ELEMENT ANALYSIS; HIP DISLOCATION; JOINT CAPSULE; JOINT INSTABILITY; PRIORITY JOURNAL; RISK ASSESSMENT; TOTAL HIP PROSTHESIS; VALIDITY;

EID: 80053210594     PISSN: 07360266     EISSN: 1554527X     Source Type: Journal    
DOI: 10.1002/jor.21435     Document Type: Article
Times cited : (68)

References (29)
  • 1
    • 58649122701 scopus 로고    scopus 로고
    • The epidemiology of revision total hip arthroplasty in the United States
    • Bozic KJ, Kurtz SM, Lau E, et al. 2009. The epidemiology of revision total hip arthroplasty in the United States. J Bone Joint Surg Am 91: 128-133.
    • (2009) J Bone Joint Surg Am , vol.91 , pp. 128-133
    • Bozic, K.J.1    Kurtz, S.M.2    Lau, E.3
  • 3
    • 0026694342 scopus 로고
    • Dislocation in low-friction arthroplasty
    • García-Cimbrelo E, Munuera L,. 1992. Dislocation in low-friction arthroplasty. J Arthroplasty 7: 149-155.
    • (1992) J Arthroplasty , vol.7 , pp. 149-155
    • García-Cimbrelo, E.1    Munuera, L.2
  • 5
    • 0026766148 scopus 로고
    • Instability after total hip arthroplasty
    • Morrey B,. 1992. Instability after total hip arthroplasty. Orthop Clin North Am 23: 237-248.
    • (1992) Orthop Clin North Am , vol.23 , pp. 237-248
    • Morrey, B.1
  • 6
    • 0036909345 scopus 로고    scopus 로고
    • Surgical approach, abductor function, and total hip arthroplasty dislocation
    • Masonis JL, Bourne RB,. 2002. Surgical approach, abductor function, and total hip arthroplasty dislocation. Clin Orthop Relat Res 405: 46-53. (Pubitemid 36008243)
    • (2002) Clinical Orthopaedics and Related Research , Issue.405 , pp. 46-53
    • Masonis, J.L.1    Bourne, R.B.2
  • 8
    • 1942518366 scopus 로고    scopus 로고
    • A simple capsulorrhaphy in a posterior approach for total hip arthroplasty
    • DOI 10.1016/j.arth.2003.10.002, PII S0883540303005230
    • Dixon MC, Scott RD, Schai PA, et al. 2004. A simple capsulorrhaphy in a posterior approach for total hip arthroplasty. J Arthroplasty 19: 373-376. (Pubitemid 38519834)
    • (2004) Journal of Arthroplasty , vol.19 , Issue.3 , pp. 373-376
    • Dixon, M.C.1    Scott, R.D.2    Schai, P.A.3    Stamos, V.4
  • 9
    • 0031733981 scopus 로고    scopus 로고
    • Posterior approach to total hip replacement using enhanced posterior soft tissue repair
    • Pellicci PM, Bostrom M, Poss R,. 1998. Posterior approach to total hip replacement using enhanced posterior soft tissue repair. Clin Orthop Relat Res 355: 224-228. (Pubitemid 28538118)
    • (1998) Clinical Orthopaedics and Related Research , Issue.355 , pp. 224-228
    • Pellicci, P.M.1    Bostrom, M.2    Poss, R.3
  • 10
    • 0141758368 scopus 로고    scopus 로고
    • The early dislocation rate in primary total hip arthroplasty following the posterior approach with posterior soft-tissue repair
    • DOI 10.1016/S0883-5403(03)00254-7
    • Weeden SH, Paprosky WG, Bowling JW,. 2003. The early dislocation rate in primary total hip arthroplasty following the posterior approach with posterior soft-tissue repair. J Arthroplasty 18: 709-713. (Pubitemid 37176599)
    • (2003) Journal of Arthroplasty , vol.18 , Issue.6 , pp. 709-713
    • Weeden, S.H.1    Paprosky, W.G.2    Bowling, J.W.3
  • 11
  • 14
    • 12344321393 scopus 로고    scopus 로고
    • Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes: An in vitro study
    • DOI 10.1016/j.arth.2004.07.008, PII S0883540304003924
    • Burroughs BR, Hallstrom B, Golladay GJ, et al. 2005. Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes: An in vitro study. J Arthroplasty 20: 11-19. (Pubitemid 40127098)
    • (2005) Journal of Arthroplasty , vol.20 , Issue.1 , pp. 11-19
    • Burroughs, B.R.1    Hallstrom, B.2    Golladay, G.J.3    Hoeffel, D.4    Harris, W.H.5
  • 15
    • 32644440100 scopus 로고    scopus 로고
    • Design factors influencing performance of constrained acetabular liners: Finite element characterization
    • DOI 10.1016/j.jbiomech.2005.01.032, PII S0021929005000722
    • Bouchard SM, Stewart KJ, Pedersen DR, et al. 2006. Design factors influencing performance of constrained acetabular liners: Finite element characterization. J Biomech 39: 885-893. (Pubitemid 43243776)
    • (2006) Journal of Biomechanics , vol.39 , Issue.5 , pp. 885-893
    • Bouchard, S.M.1    Stewart, K.J.2    Pedersen, D.R.3    Callaghan, J.J.4    Brown, T.D.5
  • 16
    • 0036156841 scopus 로고    scopus 로고
    • Effects of acetabular component orientation on dislocation propensity for small-head-size total hip arthroplasty
    • DOI 10.1016/S0268-0033(01)00096-1, PII S0268003301000961
    • Nadzadi ME, Pedersen DR, Callaghan JJ, et al. 2002. Effects of acetabular component orientation on dislocation propensity for small-head-size total hip arthroplasty. Clin Biomech 17: 32-40. (Pubitemid 34098774)
    • (2002) Clinical Biomechanics , vol.17 , Issue.1 , pp. 32-40
    • Nadzadi, M.E.1    Pedersen, D.R.2    Callaghan, J.J.3    Brown, T.D.4
  • 17
    • 0037398768 scopus 로고    scopus 로고
    • Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation
    • DOI 10.1016/S0021-9290(02)00232-4, PII S0021929002002324
    • Nadzadi ME, Pedersen DR, Yack HJ, et al. 2003. Kinematics, kinetics, and finite element analysis of commonplace maneuvers at risk for total hip dislocation. J Biomech 36: 577-591. (Pubitemid 36207588)
    • (2003) Journal of Biomechanics , vol.36 , Issue.4 , pp. 577-591
    • Nadzadi, M.E.1    Pedersen, D.R.2    Yack, H.J.3    Callaghan, J.J.4    Brown, T.D.5
  • 18
    • 16844378530 scopus 로고    scopus 로고
    • Activity-dependence of the "safe zone" for impingement versus dislocation avoidance
    • DOI 10.1016/j.medengphy.2004.09.004, Current Status of Orthopaedic Biomechanics
    • Pedersen DR, Callaghan JJ, Brown TD,. 2005. Activity-dependence of the "safe zone" for impingement versus dislocation avoidance. Med Eng Phys 27: 323-328. (Pubitemid 40488773)
    • (2005) Medical Engineering and Physics , vol.27 , Issue.4 , pp. 323-328
    • Pedersen, D.R.1    Callaghan, J.J.2    Brown, T.D.3
  • 20
    • 26444546344 scopus 로고    scopus 로고
    • Development and physical validation of a finite element model of total hip dislocation
    • Scifert CF, Brown TD, Pedersen DR, et al. 1999. Development and physical validation of a finite element model of total hip dislocation. Comput Methods Biomech Biomed Eng 2: 139-147.
    • (1999) Comput Methods Biomech Biomed Eng , vol.2 , pp. 139-147
    • Scifert, C.F.1    Brown, T.D.2    Pedersen, D.R.3
  • 21
    • 4043133785 scopus 로고    scopus 로고
    • Implementing capsule representation in a total hip dislocation finite element model
    • Stewart KJ, Pedersen DR, Callaghan JJ, et al. 2004. Implementing capsule representation in a total hip dislocation finite element model. Iowa Orthop J 24: 1-8.
    • (2004) Iowa Orthop J , vol.24 , pp. 1-8
    • Stewart, K.J.1    Pedersen, D.R.2    Callaghan, J.J.3
  • 22
    • 33745171176 scopus 로고    scopus 로고
    • Hyperelastic modelling of arterial layers with distributed collagen fibre orientations
    • DOI 10.1098/rsif.2005.0073
    • Gasser TC, Ogden RW, Holzapfel GA,. 2006. Hyperelastic modelling of arterial layers with distributed collagen fibre orientations. JR Soc Interface 3: 15-35. (Pubitemid 46682201)
    • (2006) Journal of the Royal Society Interface , vol.3 , Issue.6 , pp. 15-35
    • Gasser, T.C.1    Ogden, R.W.2    Holzapfel, G.A.3
  • 23
    • 0036842397 scopus 로고    scopus 로고
    • Spatial distribution of hip capsule structural and material properties
    • DOI 10.1016/S0021-9290(02)00091-X, PII S002192900200091X
    • Stewart KJ, Edmonds-Wilson RH, Brand RA, et al. 2002. Spatial distribution of hip capsule structural and material properties. J Biomech 35: 1491-1498. (Pubitemid 35292483)
    • (2002) Journal of Biomechanics , vol.35 , Issue.11 , pp. 1491-1498
    • Stewart, K.J.1    Edmonds-Wilson, R.H.2    Brand, R.A.3    Brown, T.D.4
  • 26
    • 0026590993 scopus 로고
    • Piriformis tendon repair failure after total hip replacement
    • Kao JT, Woolson ST,. 1992. Piriformis tendon repair failure after total hip replacement. Orthop Rev 21: 171-174.
    • (1992) Orthop Rev , vol.21 , pp. 171-174
    • Kao, J.T.1    Woolson, S.T.2
  • 28
    • 0017682924 scopus 로고
    • Normal processes and restraints in wound healing
    • Carpenter NH, Gates DJ, Williams HT,. 1977. Normal processes and restraints in wound healing. Can J Surg 20: 314-323.
    • (1977) Can J Surg , vol.20 , pp. 314-323
    • Carpenter, N.H.1    Gates, D.J.2    Williams, H.T.3
  • 29
    • 15244361629 scopus 로고    scopus 로고
    • Flexor digitorum profundus tendon to bone tunnel repair: A vascularization and histologic study in canines
    • DOI 10.1016/j.jhsa.2004.02.007
    • Dovan TT, Ritty T, Ditsios K, et al. 2005. Flexor digitorum profundus tendon to bone tunnel repair: A vascularization and histologic study in canines. J Hand Surg Am 30: 246-257. (Pubitemid 40387533)
    • (2005) Journal of Hand Surgery , vol.30 , Issue.2 , pp. 246-257
    • Dovan, T.T.1    Ritty, T.2    Ditsios, K.3    Silva, M.J.4    Kusano, N.5    Gelberman, R.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.