Volumn 27, Issue 2, 2011, Pages 114-120

Quantitative analysis of metallic artifacts caused by dental metals: Comparison of cone-beam and multi-detector row CT scanners

Author keywords

Artifact; Computed tomography; Cone beam computed tomography; Metals

Indexed keywords

ALLOY; ALUMINUM; CHROMIUM; COBALT; GOLD; TITANIUM;

EID: 83655201462     PISSN: 09116028     EISSN: 16139674     Source Type: Journal    
DOI: 10.1007/s11282-011-0071-z     Document Type: Article
Times cited : (52)

References (27)
  • 1
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results
    • P Mozzo C Procacci A Tacconi PT Martini IA Andreis 1998 A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results Eur Radiol 8 1558 1564 9866761 10.1007/s003300050586 (Pubitemid 128662693)
    • (1998) European Radiology , vol.8 , Issue.9 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Tinazzi Martini, P.4    Bergamo Andreis, I.A.5
  • 2
    • 0033156083 scopus 로고    scopus 로고
    • Development of a compact computed tomographic apparatus for dental use
    • 10455389 10.1038/sj.dmfr.4600448
    • Y Arai E Tammisalo K Iwai K Hashimoto K Shinoda 1999 Development of a compact computed tomographic apparatus for dental use Dentomaxillofac Radiol 28 245 248 10455389 10.1038/sj.dmfr.4600448
    • (1999) Dentomaxillofac Radiol , vol.28 , pp. 245-248
    • Arai, Y.1    Tammisalo, E.2    Iwai, K.3    Hashimoto, K.4    Shinoda, K.5
  • 3
    • 0023866456 scopus 로고
    • Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants
    • DD Robertson PJ Weiss EK Fishman D Magid PS Walker 1988 Evaluation of CT techniques for reducing artifacts in the presence of metallic orthopedic implants J Comput Assist Tomogr 12 236 241 3351038 10.1097/00004728-198803000- 00012 (Pubitemid 18079014)
    • (1988) Journal of Computer Assisted Tomography , vol.12 , Issue.2 , pp. 236-241
    • Robertson, D.D.1    Weiss, P.J.2    Fishman, E.K.3    Magid, D.4    Walker, P.S.5
  • 4
    • 79952363437 scopus 로고    scopus 로고
    • Metal artifact reduction in dental CT images using polar mathematical morphology
    • Naranjo V, Lloréns R, Alcañiz M, López-Mir F. Metal artifact reduction in dental CT images using polar mathematical morphology. Comput Methods Programs Biomed. 2011;102:64-74.
    • (2011) Comput Methods Programs Biomed. , vol.102 , pp. 64-74
    • Naranjo V, L.1
  • 5
    • 80052066334 scopus 로고    scopus 로고
    • Successive iterative restoration applied to streak artifact reduction in X-ray CT image of dento-alveolar region
    • doi: 10.1007/s11548-010-0544-2
    • Dong J, Kondo A, Abe K, Hayakawa Y. Successive iterative restoration applied to streak artifact reduction in X-ray CT image of dento-alveolar region. Int J Comput Assist Radiol Surg. 2011. doi: 10.1007/s11548-010-0544-2.
    • (2011) Int J Comput Assist Radiol Surg.
    • Dong, J.1    Kondo, A.2    Abe, K.3    Hayakawa, Y.4
  • 7
    • 79952149676 scopus 로고    scopus 로고
    • Dental CT metal artefact reduction based on sequential substitution
    • 21346086 10.1259/dmfr/25260548
    • S Tohnak AJ Mehnert M Mahoney S Crozier 2011 Dental CT metal artefact reduction based on sequential substitution Dentomaxillofac Radiol 40 184 190 21346086 10.1259/dmfr/25260548
    • (2011) Dentomaxillofac Radiol , vol.40 , pp. 184-190
    • Tohnak, S.1    Mehnert, A.J.2    Mahoney, M.3    Crozier, S.4
  • 8
    • 77953619570 scopus 로고    scopus 로고
    • Iterative correction applied to streak artifact reduction in an X-ray computed tomography image of the dento-alveolar region
    • 10.1007/s11282-010-0037-6
    • A Kondo Y Hayakawa J Dong A Honda 2010 Iterative correction applied to streak artifact reduction in an X-ray computed tomography image of the dento-alveolar region Oral Radiol 26 61 65 10.1007/s11282-010-0037-6
    • (2010) Oral Radiol , vol.26 , pp. 61-65
    • Kondo, A.1    Hayakawa, Y.2    Dong, J.3    Honda, A.4
  • 10
    • 19744369868 scopus 로고    scopus 로고
    • Artifact in CT: Recognition and avoidance
    • 15537976 10.1148/rg.246045065
    • JF Barrett N Keat 2004 Artifact in CT: recognition and avoidance Radiographics 24 1679 1691 15537976 10.1148/rg.246045065
    • (2004) Radiographics , vol.24 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 11
    • 49949096845 scopus 로고    scopus 로고
    • Metal artifact reduction by the alteration of technical factors in multidetector computed tomography: A 3 dimensional quantitative assessment
    • 18664853 10.1097/RCT.0b013e3181568b27
    • SG Moon SH Hong JY Choi WS Jun HG Kang HS Kim, et al. 2008 Metal artifact reduction by the alteration of technical factors in multidetector computed tomography: a 3 dimensional quantitative assessment J Comput Assist Tomogr 32 630 633 18664853 10.1097/RCT.0b013e3181568b27
    • (2008) J Comput Assist Tomogr , vol.32 , pp. 630-633
    • Moon, S.G.1    Hong, S.H.2    Choi, J.Y.3    Jun, W.S.4    Kang, H.G.5    Kim, H.S.6
  • 12
    • 0027371553 scopus 로고
    • Comparison of CT imaging artifacts from craniomaxillofacial internal fixation devices
    • TG Fiala RA Novelline MJ Yaremchuk 1993 Comparison of CT imaging artifacts from craniomaxillofacial internal fixation devices Plast Reconstr Surg 92 1227 1232 8248397 (Pubitemid 23356949)
    • (1993) Plastic and Reconstructive Surgery , vol.92 , Issue.7 , pp. 1227-1232
    • Fiala, T.G.S.1    Novelline, R.A.2    Yaremchuk, M.J.3
  • 13
    • 0027998049 scopus 로고
    • Cranio-orbital reconstruction: Safety and image quality of metallic implants on CT and MRI scanning
    • PK Sullivan JF Smith AA Rozzelle 1994 Cranio-orbital reconstruction: safety and image quality of metallic implants on CT and MRI scanning Plast Reconstr Surg 94 589 596 7938281 10.1097/00006534-199410000-00004 (Pubitemid 24314057)
    • (1994) Plastic and Reconstructive Surgery , vol.94 , Issue.5 , pp. 589-596
    • Sullivan, P.K.1    Smith, J.F.2    Rozzelle, A.A.3
  • 14
    • 34648826690 scopus 로고    scopus 로고
    • A pragmatic protocol for reduction in the metal artifact and radiation dose in multislice computed tomography of the spine: Cadaveric evaluation after cervical pedicle screw placement
    • DOI 10.1097/01.rct.0000250117.18080.d8, PII 0000472820070700000026
    • IS Lee HJ Kim BK Choi, et al. 2007 A pragmatic protocol for reduction in the metal artifact and radiation dose in multislice computed tomography of the spine: cadaveric evaluation after cervical pedicle screw placement J Comput Assist Tomogr 31 635 641 17882046 10.1097/01.rct.0000250117.18080.d8 (Pubitemid 47457684)
    • (2007) Journal of Computer Assisted Tomography , vol.31 , Issue.4 , pp. 635-641
    • Lee, I.S.1    Kim, H.J.2    Choi, B.K.3    Jeong, Y.J.4    Lee, T.H.5    Moon, T.-Y.6    Won Kang, D.7
  • 15
    • 22544475284 scopus 로고    scopus 로고
    • Metallic prosthesis: Technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients
    • DOI 10.1148/radiol.2362041565
    • T Dalal MK Kalra SM Rizzo B Schmidt C Suess T Flohr, et al. 2005 Metallic prosthesis: technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients Radiology 236 671 675 16040924 10.1148/radiol.2362041565 (Pubitemid 41023458)
    • (2005) Radiology , vol.236 , Issue.2 , pp. 671-675
    • Dalal, T.1    Kalra, M.K.2    Rizzo, S.M.R.3    Schmidt, B.4    Suess, C.5    Flohr, T.6    Blake, M.A.7    Saini, S.8
  • 16
    • 34347238633 scopus 로고    scopus 로고
    • Beam hardening artefacts occur in dental implant scans with the NewTom® cone beam CT but not with the dental 4-row multidetector CT
    • DOI 10.1259/dmfr/32579161
    • FG Draenert E Coppenrath P Herzog S Müller UG Mueller-Lisse 2007 Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT Dentomaxillofac Radiol 36 198 203 17536086 10.1259/dmfr/32579161 (Pubitemid 46999234)
    • (2007) Dentomaxillofacial Radiology , vol.36 , Issue.4 , pp. 198-203
    • Draenert, F.G.1    Coppenrath, E.2    Herzog, P.3    Muller, S.4    Mueller-Lisse, U.G.5
  • 17
    • 39649101935 scopus 로고    scopus 로고
    • Common orthodontic appliances cause artifacts that degrade the diagnostic quality of CBCT images
    • 18240748
    • MA Sanders C Hoyjberg CB Chu VL Leggitt JS Kim 2007 Common orthodontic appliances cause artifacts that degrade the diagnostic quality of CBCT images J Calif Dent Assoc 35 850 857 18240748
    • (2007) J Calif Dent Assoc , vol.35 , pp. 850-857
    • Sanders, M.A.1    Hoyjberg, C.2    Chu, C.B.3    Leggitt, V.L.4    Kim, J.S.5
  • 18
    • 72949119102 scopus 로고    scopus 로고
    • On cone-beam computed tomography artifacts induced by titanium implants
    • 19845706 10.1111/j.1600-0501.2009.01817.x
    • RK Schulze D Berndt B d'Hoedt 2010 On cone-beam computed tomography artifacts induced by titanium implants Clin Oral Implants Res 21 100 107 19845706 10.1111/j.1600-0501.2009.01817.x
    • (2010) Clin Oral Implants Res , vol.21 , pp. 100-107
    • Schulze, R.K.1    Berndt, D.2    D'Hoedt, B.3
  • 19
    • 33645731806 scopus 로고    scopus 로고
    • Cone-beam computed tomography in orthodontics: Benefits and limitations
    • 16331544 10.1007/s00056-005-0519-z
    • C Holberg S Steinhäuser P Geis I Rudzki-Janson 2005 Cone-beam computed tomography in orthodontics: benefits and limitations J Orofac Orthop 66 434 444 16331544 10.1007/s00056-005-0519-z
    • (2005) J Orofac Orthop , vol.66 , pp. 434-444
    • Holberg, C.1    Steinhäuser, S.2    Geis, P.3    Rudzki-Janson, I.4
  • 20
    • 38949165381 scopus 로고    scopus 로고
    • Diagnostic quality of multiplanar reformations obtained with a newly developed cone beam device for maxillofacial imaging
    • DOI 10.1259/dmfr/25381129
    • RA Mischkowski P Scherer L Ritter J Neugebauer E Keeve JE Zöller 2008 Diagnostic quality of multiplanar reformations obtained with a newly developed cone beam device for maxillofacial imaging Dentomaxillofac Radiol 37 1 9 18195248 10.1259/dmfr/25381129 (Pubitemid 351211970)
    • (2008) Dentomaxillofacial Radiology , vol.37 , Issue.1 , pp. 1-9
    • Mischkowski, R.A.1    Scherer, P.2    Ritter, L.3    Neugebauer, J.4    Keeve, E.5    Zoller, J.E.6
  • 21
    • 0027416342 scopus 로고
    • Mass attenuation coefficients, quantities and units for use in bone mineral determinations
    • R Jonson 1993 Mass attenuation coefficients, quantities and units for use in bone mineral determinations Osteoporos Int 3 103 106 8453189 10.1007/BF01623381 (Pubitemid 23088904)
    • (1993) Osteoporosis International , vol.3 , Issue.2 , pp. 103-106
    • Jonson, R.1
  • 22
    • 83655196284 scopus 로고    scopus 로고
    • Computed tomography (CT) and CT arthrography
    • A.M. Davies V.N. Cassar-Pullicino (eds). Springer-Verlag Heidelberg
    • Whitehouse RW. Computed tomography (CT) and CT arthrography. In: Davies AM, Cassar-Pullicino VN, editors. Imaging of the knee: techniques and applications. Heidelberg: Springer-Verlag; 2002.
    • (2002) Imaging of the Knee: Techniques and Applications
    • Whitehouse, R.W.1
  • 23
    • 77950986866 scopus 로고    scopus 로고
    • Biomechanical and bone histomorphologic evaluation of four surfaces on plateau root form implants: An experimental study in dogs
    • 20416517 10.1016/j.tripleo.2010.01.004
    • PG Coelho R Granato C Marin EA Bonfante MN Janal M Suzuki 2010 Biomechanical and bone histomorphologic evaluation of four surfaces on plateau root form implants: an experimental study in dogs Oral Surg Oral Med Oral Pathol Oral Radiol Endod 109 e39 e45 20416517 10.1016/j.tripleo.2010.01.004
    • (2010) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.109
    • Coelho, P.G.1    Granato, R.2    Marin, C.3    Bonfante, E.A.4    Janal, M.N.5    Suzuki, M.6
  • 25
    • 0031230562 scopus 로고    scopus 로고
    • Tensile strength of soldered gold alloy joints
    • 9297642 10.1016/S0022-3913(97)70024-6
    • I Watanabe E Watanabe M Atsuta T Okabe 1997 Tensile strength of soldered gold alloy joints J Prosthet Dent 78 260 266 9297642 10.1016/S0022-3913(97) 70024-6
    • (1997) J Prosthet Dent , vol.78 , pp. 260-266
    • Watanabe, I.1    Watanabe, E.2    Atsuta, M.3    Okabe, T.4
  • 26
    • 23344443347 scopus 로고    scopus 로고
    • Intermaxillary tooth size discrepancy and mesiodistal crown dimensions for a Turkish population
    • DOI 10.1016/j.ajodo.2004.04.029, PII S0889540605004257
    • T Uysal Z Sari 2005 Intermaxillary tooth size discrepancy and mesiodistal crown dimensions for a Turkish population Am J Orthod Dentofacial Orthop 128 226 230 16102409 10.1016/j.ajodo.2004.04.029 (Pubitemid 41105403)
    • (2005) American Journal of Orthodontics and Dentofacial Orthopedics , vol.128 , Issue.2 , pp. 226-230
    • Uysal, T.1    Sari, Z.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.