-
1
-
-
68549104047
-
Conebeam CT of the head and neck, part 2: Clinical applications
-
19461061 10.3174/ajnr.A1654 1:STN:280:DC%2BD1Mrkt1KksA%3D%3D
-
AC Miracle SK Mukherji 2009 Conebeam CT of the head and neck, part 2: clinical applications Am J Neuroradiol 30 1285 1292 19461061 10.3174/ajnr.A1654 1:STN:280:DC%2BD1Mrkt1KksA%3D%3D
-
(2009)
Am J Neuroradiol
, vol.30
, pp. 1285-1292
-
-
Miracle, A.C.1
Mukherji, S.K.2
-
2
-
-
70349576613
-
Metallic artifacts caused by dental metal prostheses on PET images: A PET/CT phantom study using different PET/CT scanners
-
10.1007/s12149-009-0254-4 19399580 10.1007/s12149-009-0254-4
-
H Shimamoto N Kakimoto K Fujino S Hamada E Shimosegawa S Murakami S Furukawa J Hatazawa 2009 Metallic artifacts caused by dental metal prostheses on PET images: a PET/CT phantom study using different PET/CT scanners Ann Nucl Med 23 443 449 10.1007/s12149-009-0254-4 19399580 10.1007/s12149-009-0254-4
-
(2009)
Ann Nucl Med
, vol.23
, pp. 443-449
-
-
Shimamoto, H.1
Kakimoto, N.2
Fujino, K.3
Hamada, S.4
Shimosegawa, E.5
Murakami, S.6
Furukawa, S.7
Hatazawa, J.8
-
3
-
-
67349175792
-
Quantitative assessment of image noise and streak artifact on CT image: Comparison of z-axis automatic tube current modulation technique with fixed tube current technique
-
10.1016/j.compmedimag.2009.02.003 19342196 10.1016/j.compmedimag.2009.02. 003
-
K Imai M Ikeda Y Enchi T Niimi 2009 Quantitative assessment of image noise and streak artifact on CT image: comparison of z-axis automatic tube current modulation technique with fixed tube current technique Comput Med Imaging Graph 33 353 358 10.1016/j.compmedimag.2009.02.003 19342196 10.1016/j.compmedimag.2009.02.003
-
(2009)
Comput Med Imaging Graph
, vol.33
, pp. 353-358
-
-
Imai, K.1
Ikeda, M.2
Enchi, Y.3
Niimi, T.4
-
4
-
-
46749100234
-
Does reducing CT artifacts from dental implants influence the PET interpretation in PET/CT studies of oral cancer and head and neck cancer?
-
DOI 10.2967/jnumed.107.049858
-
C Nahmias C Lemmens D Faul E Carlson M Long T Blodgett J Nuyts D Townsend 2008 Does reducing CT artifacts from dental implants influence the PET interpretation in PET/CT studies of oral cancer and head and neck cancer? J Nucl Med 49 1047 1052 10.2967/jnumed.107.049858 18552154 10.2967/jnumed.107.049858 (Pubitemid 351948011)
-
(2008)
Journal of Nuclear Medicine
, vol.49
, Issue.7
, pp. 1047-1052
-
-
Nahmias, C.1
Lemmens, C.2
Faul, D.3
Carlson, E.4
Long, M.5
Blodgett, T.6
Nuyts, J.7
Townsend, D.8
-
5
-
-
36749046235
-
Analysis of streak artefacts on CT images using statistics of extremes
-
DOI 10.1259/bjr/93741044
-
K Imai M Ikeda S Wada Y Enchi T Niimi 2007 Analysis of streak artefacts on CT images using statistics of extremes Br J Radiol 80 911 918 17989333 10.1259/bjr/93741044 1:STN:280:DC%2BD2snmsVGktg%3D%3D (Pubitemid 350206221)
-
(2007)
British Journal of Radiology
, vol.80
, Issue.959
, pp. 911-918
-
-
Imai, K.1
Ikeda, M.2
Wada, S.3
Enchi, Y.4
Niimi, T.5
-
6
-
-
75749108974
-
Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT
-
20229871 10.1118/1.3276777
-
WJ Veldkamp RM Joemai AJ van der Molen J Geleijns 2010 Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT Med Phys 37 620 628 20229871 10.1118/1.3276777
-
(2010)
Med Phys
, vol.37
, pp. 620-628
-
-
Veldkamp, W.J.1
Joemai, R.M.2
Van Der Molen, A.J.3
Geleijns, J.4
-
7
-
-
70449125860
-
A novel forward projection-based metal artifact reduction method for flat-detector computed tomography
-
19826202 10.1088/0031-9155/54/21/009
-
D Prell Y Kyriakou M Beister WA Kalender 2009 A novel forward projection-based metal artifact reduction method for flat-detector computed tomography Phys Med Biol 54 6575 6591 19826202 10.1088/0031-9155/54/21/009
-
(2009)
Phys Med Biol
, vol.54
, pp. 6575-6591
-
-
Prell, D.1
Kyriakou, Y.2
Beister, M.3
Kalender, W.A.4
-
8
-
-
49949095531
-
Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: A comparison of published methods
-
10.1097/RCT.0b013e318149e215 18664852 10.1097/RCT.0b013e318149e215
-
J Rinkel WP Dillon T Funk R Gould S Prevrhal 2008 Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: a comparison of published methods J Comput Assist Tomogr 32 621 629 10.1097/RCT.0b013e318149e215 18664852 10.1097/RCT. 0b013e318149e215
-
(2008)
J Comput Assist Tomogr
, vol.32
, pp. 621-629
-
-
Rinkel, J.1
Dillon, W.P.2
Funk, T.3
Gould, R.4
Prevrhal, S.5
-
9
-
-
49949096845
-
Metal artifact reduction by the alteration of technical factors in multidetector computed tomography: A 3-dimensional quantitative assessment
-
10.1097/RCT.0b013e3181568b27 18664853 10.1097/RCT.0b013e3181568b27
-
SG Moon SH Hong JY Choi WS Jun HG Kang HS Kim HS Kang 2008 Metal artifact reduction by the alteration of technical factors in multidetector computed tomography: a 3-dimensional quantitative assessment J Comput Assist Tomogr 32 630 633 10.1097/RCT.0b013e3181568b27 18664853 10.1097/RCT.0b013e3181568b27
-
(2008)
J Comput Assist Tomogr
, vol.32
, pp. 630-633
-
-
Moon, S.G.1
Hong, S.H.2
Choi, J.Y.3
Jun, W.S.4
Kang, H.G.5
Kim, H.S.6
Kang, H.S.7
-
10
-
-
33846826893
-
Reducing metal artifacts in cone-beam CT images by preprocessing projection data
-
DOI 10.1016/j.ijrobp.2006.09.045, PII S0360301606032081
-
Y Zhang L Zhang XR Zhu AK Lee M Chambers L Dong 2007 Reducing metal artifacts in cone-beam CT images by preprocessing projection data Int J Radiat Oncol Biol Phys 67 924 932 10.1016/j.ijrobp.2006.09.045 17161556 10.1016/j.ijrobp.2006.09.045 (Pubitemid 46215876)
-
(2007)
International Journal of Radiation Oncology Biology Physics
, vol.67
, Issue.3
, pp. 924-932
-
-
Zhang, Y.1
Zhang, L.2
Zhu, X.R.3
Lee, A.K.4
Chambers, M.5
Dong, L.6
-
11
-
-
33746633331
-
Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
-
DOI 10.1118/1.2218062
-
M Bal L Spies 2006 Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering Med Phys 33 2852 2859 16964861 10.1118/1.2218062 (Pubitemid 44154556)
-
(2006)
Medical Physics
, vol.33
, Issue.8
, pp. 2852-2859
-
-
Bal, M.1
Spies, L.2
-
12
-
-
32544441568
-
Convergence study of an accelerated ML-EM algorithm using bigger step size
-
DOI 10.1088/0031-9155/51/2/004, PII S0031915506002090
-
D Hwang GL Zeng 2006 Convergence study of an accelerated ML-EM algorithm using bigger step size Phys Med Biol 51 237 252 16394336 10.1088/0031-9155/51/2/ 004 (Pubitemid 43231969)
-
(2006)
Physics in Medicine and Biology
, vol.51
, Issue.2
, pp. 237-252
-
-
Hwang, D.1
Zeng, G.L.2
-
13
-
-
0033853232
-
Fast iterative algorithm for metal artifact reduction in X-ray CT
-
G Wang T Frei MW Vannier 2000 Fast iterative algorithm for metal artifact reduction in X-ray CT Acad Radiol 7 607 614 10952111 10.1016/S1076-6332(00) 80576-0 1:STN:280:DC%2BD3M7gvFWhuw%3D%3D (Pubitemid 30602828)
-
(2000)
Academic Radiology
, vol.7
, Issue.8
, pp. 607-614
-
-
Wang, G.1
Frei, T.2
Vannier, M.W.3
-
14
-
-
0026974841
-
A new computed tomography using imaging-plate and incomplete projection data
-
10.1007/BF02347809 10.1007/BF02347809
-
Y Morita 1992 A new computed tomography using imaging-plate and incomplete projection data Oral Radiol 8 119 126 10.1007/BF02347809 10.1007/BF02347809
-
(1992)
Oral Radiol
, vol.8
, pp. 119-126
-
-
Morita, Y.1
-
15
-
-
0030621857
-
Tuned-aperture computed tomography (TACT™). Theory and application for three-dimensional dento-alveolar imaging
-
RL Webber RA Horton DA Tyndall JB Ludlow 1997 Tuned-aperture computed tomography (TACT). Theory and application for three-dimensional dento-alveolar imaging Dentomaxillofac Radiol 1997 26 53 62 10.1038/sj.dmfr.4600201 (Pubitemid 127495006)
-
(1997)
Dentomaxillofacial Radiology
, vol.26
, Issue.1
, pp. 53-62
-
-
Webber, R.L.1
Horton, R.A.2
Tyndall, D.A.3
Ludlow, J.B.4
-
16
-
-
77953619570
-
Iterative correction applied to streak artifact reduction in an X-ray computed tomography image of the dento-alveolar region
-
10.1007/s11282-010-0037-6 10.1007/s11282-010-0037-6
-
A Kondo Y Hayakawa J Dong A Honda 2010 Iterative correction applied to streak artifact reduction in an X-ray computed tomography image of the dento-alveolar region Oral Radiol 26 61 65 10.1007/s11282-010-0037-6 10.1007/s11282-010-0037-6
-
(2010)
Oral Radiol
, vol.26
, pp. 61-65
-
-
Kondo, A.1
Hayakawa, Y.2
Dong, J.3
Honda, A.4
-
17
-
-
80052046246
-
Intensity-based Bayesian framework for image reconstruction from sparse projection data
-
EA Rashed H Kudo 2009 Intensity-based Bayesian framework for image reconstruction from sparse projection data Med Imaging Technol Jpn 27 243 251
-
(2009)
Med Imaging Technol Jpn
, vol.27
, pp. 243-251
-
-
Rashed, E.A.1
Kudo, H.2
|