메뉴 건너뛰기




Volumn 40, Issue 3, 2011, Pages 184-190

Dental CT metal artefact reduction based on sequential substitution

Author keywords

Artefacts; Computed tomography; X ray

Indexed keywords

METAL;

EID: 79952149676     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr/25260548     Document Type: Article
Times cited : (37)

References (18)
  • 2
    • 33645801797 scopus 로고    scopus 로고
    • Maximum intensity projection of cranial computed tomography data for dental identification
    • Jackowski C, Aghayev E, Sonnenschein M, Dirnhofer R, Thali MJ. Maximum intensity projection of cranial computed tomography data for dental identification. Int J Legal Med 2006; 120: 165-167.
    • (2006) Int J Legal Med , vol.120 , pp. 165-167
    • Jackowski, C.1    Aghayev, E.2    Sonnenschein, M.3    Dirnhofer, R.4    Thali, M.J.5
  • 5
    • 0033431430 scopus 로고    scopus 로고
    • Iterative X-ray cone-beam tomography for metal artifact reduction and local region reconstruction
    • Wang G, Vannier MW, Cheng P-C. Iterative x-ray cone-beam tomography for metal artifact reduction and local region reconstruction. Microsc Microanal 1999; 5: 58-65. (Pubitemid 129479946)
    • (1999) Microscopy and Microanalysis , vol.5 , Issue.1 , pp. 58-65
    • Wang, G.1    Vannier, M.W.2    Cheng, P.-C.3
  • 6
    • 0034206972 scopus 로고    scopus 로고
    • Reduction of metal steak artifacts in X-ray computed tomography using a transmission maximum a posteriori algorithm
    • Man BD, Nuyts J, Dupont P, Marchal G. Reduction of metal steak artifacts in X-ray computed tomography using a transmission maximum a posteriori algorithm. IEEE Trans Nucl Sci 2000; 47: 977-981.
    • (2000) IEEE Trans Nucl Sci , vol.47 , pp. 977-981
    • Man, B.D.1    Nuyts, J.2    Dupont, P.3    Marchal, G.4
  • 8
    • 33746633331 scopus 로고    scopus 로고
    • Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
    • DOI 10.1118/1.2218062
    • Bal M, Spies L. Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. Med Phys 2006; 33: 2852-2859. (Pubitemid 44154556)
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 2852-2859
    • Bal, M.1    Spies, L.2
  • 9
    • 0023224718 scopus 로고
    • Reduction of CT artifacts caused by metallic implants
    • Kalender WA, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants. Radiology 1987; 164: 567-577.
    • (1987) Radiology , vol.164 , pp. 567-577
    • Kalender, W.A.1    Hebel, R.2    Ebersberger, J.3
  • 12
    • 33645774093 scopus 로고    scopus 로고
    • Preliminary study of correction of original metal artifacts due to I-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy
    • Takahashi Y, Mori S, Kozuka T, Gomi K, Nose T, Tahara T, et al. Preliminary study of correction of original metal artifacts due to I-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy. Radiation Med 2006; 24: 133-138.
    • (2006) Radiation Med , vol.24 , pp. 133-138
    • Takahashi, Y.1    Mori, S.2    Kozuka, T.3    Gomi, K.4    Nose, T.5    Tahara, T.6
  • 13
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • Barrett JF, Keat N. Artifacts in CT: Recognition and avoidance. Radiographics 2004; 24: 1679-1691.
    • (2004) Radiographics , vol.24 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 14
    • 0019190043 scopus 로고
    • A simple computational method for reducing streak artefacts in CT images
    • Henrich G. A simple computational method for reducing streak artefacts in CT images. Comput Tomogr 1979; 4: 67-71.
    • (1979) Comput Tomogr , vol.4 , pp. 67-71
    • Henrich, G.1
  • 15
    • 23844443223 scopus 로고    scopus 로고
    • A radial adaptive filter for metal artifact reduction
    • DOI 10.1117/12.593095, 243, Medical Imaging 2005 - Image Processing
    • Bal M, Celik H, Subramanyan K, Eek K, Spies L. A radial adaptive filter for metal artifact reduction. In: Fitzpatrick JM, Reinhardt JM, editors. Proceedings of SPIE-The International Society for Optical Engineering, Medical Imaging: Image Processing; Feb 17, 2005; San Diego, CA, USA: SPIE-International Society for Optical Engineering 2005; 2075-2082. (Pubitemid 41146546)
    • (2005) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.5747 , Issue.3 , pp. 2075-2082
    • Bal, M.1    Celik, K.2    Subramanyan, K.3    Eck, K.4    Spies, L.5
  • 16
    • 2542496945 scopus 로고    scopus 로고
    • A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images
    • DOI 10.1007/s00330-004-2263-y
    • Watzke O, Kalender WA. A pragmatic approach to metal artifact reduction in CT: Merging of metal artifact reduced images. Eur Radiol 2004; 14: 849-856. (Pubitemid 38678906)
    • (2004) European Radiology , vol.14 , Issue.5 , pp. 849-856
    • Watzke, O.1    Kalender, W.A.2
  • 17
    • 36549052302 scopus 로고    scopus 로고
    • Synthesizing dental radiographs for human identification
    • Tohnak S, Mehnert AJH, Mahoney M, Crozier S. Synthesizing dental radiographs for human identification. J Dent Res 2007; 86: 1057-1062.
    • (2007) J Dent Res , vol.86 , pp. 1057-1062
    • Tohnak, S.1    Mehnert, A.J.H.2    Mahoney, M.3    Crozier, S.4
  • 18


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.