메뉴 건너뛰기




Volumn 219, Issue 2, 2011, Pages 603-609

Computed tomography for detecting coronary artery plaques: A meta-analysis

Author keywords

Computed tomography; Intravascular ultrasound; Meta analysis; Plaque

Indexed keywords

ARTICLE; ATHEROSCLEROTIC PLAQUE; CARDIAC IMAGING; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CORONARY ARTERY ATHEROSCLEROSIS; CORONARY ARTERY PLAQUE; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; EMBASE; HUMAN; INTERMETHOD COMPARISON; INTRAVASCULAR ULTRASOUND; MEDICAL RESEARCH; MEDLINE; META ANALYSIS; PREDICTIVE VALUE; PRIORITY JOURNAL; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SYSTEMATIC REVIEW;

EID: 82955245417     PISSN: 00219150     EISSN: 18791484     Source Type: Journal    
DOI: 10.1016/j.atherosclerosis.2011.08.022     Document Type: Article
Times cited : (44)

References (33)
  • 1
    • 79751531393 scopus 로고    scopus 로고
    • Heart disease and stroke statistics-2011 update: a report from the American Heart Association
    • Roger V.L., Go A.S., Lloyd-Jones D.M., et al. Heart disease and stroke statistics-2011 update: a report from the American Heart Association. Circulation 2011, 123:e18-e209.
    • (2011) Circulation , vol.123
    • Roger, V.L.1    Go, A.S.2    Lloyd-Jones, D.M.3
  • 4
    • 70449481546 scopus 로고    scopus 로고
    • Incremental prognostic value of multi-slice computed tomography coronary angiography over coronary artery calcium scoring in patients with suspected coronary artery disease
    • van Werkhoven J.M., Schuijf J.D., Gaemperli O., et al. Incremental prognostic value of multi-slice computed tomography coronary angiography over coronary artery calcium scoring in patients with suspected coronary artery disease. Eur Heart J 2009, 30:2622-2629.
    • (2009) Eur Heart J , vol.30 , pp. 2622-2629
    • van Werkhoven, J.M.1    Schuijf, J.D.2    Gaemperli, O.3
  • 5
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    • Raff G.L., Gallagher M.J., O'Neill W.W., Goldstein J.A. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005, 46:552-557.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3    Goldstein, J.A.4
  • 6
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • Whiting P., Rutjes A.W., Reitsma J.B., Bossuyt P.M., Kleijnen J. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 2003, 3:25.
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25
    • Whiting, P.1    Rutjes, A.W.2    Reitsma, J.B.3    Bossuyt, P.M.4    Kleijnen, J.5
  • 8
    • 0037186429 scopus 로고    scopus 로고
    • Advanced methods in meta-analysis: multivariate approach and meta-regression
    • van Houwelingen H.C., Arends L.R., Stijnen T. Advanced methods in meta-analysis: multivariate approach and meta-regression. Stat Med 2002, 21:589-624.
    • (2002) Stat Med , vol.21 , pp. 589-624
    • van Houwelingen, H.C.1    Arends, L.R.2    Stijnen, T.3
  • 9
    • 24944498883 scopus 로고    scopus 로고
    • Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews
    • Reitsma J.B., Glas A.S., Rutjes A.W., Scholten R.J., Bossuyt P.M., Zwinderman A.H. Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews. J Clin Epidemiol 2005, 58:982-990.
    • (2005) J Clin Epidemiol , vol.58 , pp. 982-990
    • Reitsma, J.B.1    Glas, A.S.2    Rutjes, A.W.3    Scholten, R.J.4    Bossuyt, P.M.5    Zwinderman, A.H.6
  • 10
    • 82955198311 scopus 로고    scopus 로고
    • Evaluation of plaque morphology by 64-slice computed tomographic angiography compared to intravascular ultrasound in non-occlusive segments of coronary arteries
    • Kesarwani M., Choi T., Honoris L., Shavelle D.M., Budoff M.J. Evaluation of plaque morphology by 64-slice computed tomographic angiography compared to intravascular ultrasound in non-occlusive segments of coronary arteries. J Am Coll Cardiol 2010, 55:A75.E704.
    • (2010) J Am Coll Cardiol , vol.55
    • Kesarwani, M.1    Choi, T.2    Honoris, L.3    Shavelle, D.M.4    Budoff, M.J.5
  • 11
    • 35548991488 scopus 로고    scopus 로고
    • Noninvasive detection and evaluation of coronary atheroselerotic plaques with multi-slice spiral CT: a comparative study with intravascular ultrasonograhy
    • Wu W.H., Lu B., Jiang S.L., et al. Noninvasive detection and evaluation of coronary atheroselerotic plaques with multi-slice spiral CT: a comparative study with intravascular ultrasonograhy. Chin J Radiol 2007, 41:1027-1031.
    • (2007) Chin J Radiol , vol.41 , pp. 1027-1031
    • Wu, W.H.1    Lu, B.2    Jiang, S.L.3
  • 12
    • 35649025632 scopus 로고    scopus 로고
    • Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome: a comparative study with intravascular ultrasound
    • Iriart X., Brunot S., Coste P., et al. Early characterization of atherosclerotic coronary plaques with multidetector computed tomography in patients with acute coronary syndrome: a comparative study with intravascular ultrasound. Eur Radiol 2007, 17:2581-2588.
    • (2007) Eur Radiol , vol.17 , pp. 2581-2588
    • Iriart, X.1    Brunot, S.2    Coste, P.3
  • 13
    • 33644917419 scopus 로고    scopus 로고
    • Noninvasive detection of subclinical coronary atherosclerosis coupled with assessment of changes in plaque characteristics using novel invasive imaging modalities: the Integrated Biomarker and Imaging Study (IBIS)
    • Van Mieghem C.A., McFadden E.P., de Feyter P.J., et al. Noninvasive detection of subclinical coronary atherosclerosis coupled with assessment of changes in plaque characteristics using novel invasive imaging modalities: the Integrated Biomarker and Imaging Study (IBIS). J Am Coll Cardiol 2006, 47:1134-1142.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1134-1142
    • Van Mieghem, C.A.1    McFadden, E.P.2    de Feyter, P.J.3
  • 14
    • 7944224889 scopus 로고    scopus 로고
    • Comparison of measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multidetector computed tomography versus intravascular ultrasound
    • Moselewski F., Ropers D., Pohle K., et al. Comparison of measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multidetector computed tomography versus intravascular ultrasound. Am J Cardiol 2004, 94:1294-1297.
    • (2004) Am J Cardiol , vol.94 , pp. 1294-1297
    • Moselewski, F.1    Ropers, D.2    Pohle, K.3
  • 15
    • 11144354420 scopus 로고    scopus 로고
    • Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound
    • Leber A.W., Knez A., Becker A., et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol 2004, 43:1241-1247.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1241-1247
    • Leber, A.W.1    Knez, A.2    Becker, A.3
  • 16
    • 3042660302 scopus 로고    scopus 로고
    • Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular ultrasound
    • Caussin C., Ohanessian A., Ghostine S., et al. Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular ultrasound. Am J Cardiol 2004, 94:99-104.
    • (2004) Am J Cardiol , vol.94 , pp. 99-104
    • Caussin, C.1    Ohanessian, A.2    Ghostine, S.3
  • 17
    • 0347357884 scopus 로고    scopus 로고
    • Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound
    • Achenbach S., Moselewski F., Ropers D., et al. Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound. Circulation 2004, 109:14-17.
    • (2004) Circulation , vol.109 , pp. 14-17
    • Achenbach, S.1    Moselewski, F.2    Ropers, D.3
  • 18
    • 77950909484 scopus 로고    scopus 로고
    • Qualitative assessment of non-obstructive left main coronary artery plaques using 64-multislice computed tomography compared with intravascular ultrasound
    • Shen Y., Qian J.Y., Wang M.H., et al. qualitative assessment of non-obstructive left main coronary artery plaques using 64-multislice computed tomography compared with intravascular ultrasound. Chin Med J 2010, 123:827-833.
    • (2010) Chin Med J , vol.123 , pp. 827-833
    • Shen, Y.1    Qian, J.Y.2    Wang, M.H.3
  • 19
    • 59249086750 scopus 로고    scopus 로고
    • Assessment of nonstenotic coronary lesions by 64-slice multidetector computed tomography in comparison to intravascular ultrasound: evaluation of nonculprit coronary lesions
    • Petranovic M., Soni A., Bezzera H., et al. Assessment of nonstenotic coronary lesions by 64-slice multidetector computed tomography in comparison to intravascular ultrasound: evaluation of nonculprit coronary lesions. J Cardiovasc Comput Tomogr 2009, 3:24-31.
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 24-31
    • Petranovic, M.1    Soni, A.2    Bezzera, H.3
  • 20
    • 39749104658 scopus 로고    scopus 로고
    • Identification and quantification of coronary atherosclerotic plaques: a comparison of 64-MDCT and intravascular ultrasound
    • Sun J., Zhang Z., Lu B., et al. Identification and quantification of coronary atherosclerotic plaques: a comparison of 64-MDCT and intravascular ultrasound. Am J Roentgenol 2008, 190:748-754.
    • (2008) Am J Roentgenol , vol.190 , pp. 748-754
    • Sun, J.1    Zhang, Z.2    Lu, B.3
  • 21
    • 48449087800 scopus 로고    scopus 로고
    • Qualitative and quantitative evaluation of coronary plaques with 64-slice computed tomography in comparison with intravascular ultrasound
    • Ye H.H., Kaneda H., Saito S., et al. Qualitative and quantitative evaluation of coronary plaques with 64-slice computed tomography in comparison with intravascular ultrasound. Zhonghua Xin Xue Guan Bing Za Zhi 2007, 35:648-651.
    • (2007) Zhonghua Xin Xue Guan Bing Za Zhi , vol.35 , pp. 648-651
    • Ye, H.H.1    Kaneda, H.2    Saito, S.3
  • 22
    • 31644449398 scopus 로고    scopus 로고
    • Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound
    • Leber A.W., Becker A., Knez A., et al. Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol 2006, 47:672-677.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 672-677
    • Leber, A.W.1    Becker, A.2    Knez, A.3
  • 23
    • 21344460533 scopus 로고    scopus 로고
    • Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound
    • Leber A.W., Knez A., Von Ziegler F., et al. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 2005, 46:147-154.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 147-154
    • Leber, A.W.1    Knez, A.2    Von Ziegler, F.3
  • 24
    • 36849059128 scopus 로고    scopus 로고
    • A preliminary investigated report of utilizing 64 multi-slice CT coronary angiography in the evaluation of coronary atherosclerotic plaques
    • Wang Y.H., Zhang Z.Q., Lu B. A preliminary investigated report of utilizing 64 multi-slice CT coronary angiography in the evaluation of coronary atherosclerotic plaques. Chin J Radiol 2007, 41:1189-1193.
    • (2007) Chin J Radiol , vol.41 , pp. 1189-1193
    • Wang, Y.H.1    Zhang, Z.Q.2    Lu, B.3
  • 25
    • 82955235405 scopus 로고    scopus 로고
    • Assessment of coronary plaque morphology and arterial remodeling by dual-source computed tomography: comparison with in-travascular ultrasound
    • Yu wei W.Z., Zhang Jianjun, He Lang, Lang Lingfeng, Cheng Jianming, Feng Yue Assessment of coronary plaque morphology and arterial remodeling by dual-source computed tomography: comparison with in-travascular ultrasound. Diagn Imaging Interv Radiol 2010, 19:3.
    • (2010) Diagn Imaging Interv Radiol , vol.19 , pp. 3
    • Yu wei, W.Z.1    Zhang, J.2    He, L.3    Lang, L.4    Cheng, J.5    Feng, Y.6
  • 26
    • 82955235408 scopus 로고    scopus 로고
    • Diagnostic performance of non-invasive multidetector computed tomography coronary angiography to detect coronary artery disease using different endpoints: detection of significant stenosis vs detection of atherosclerosis
    • van Velzen J.E., Schuijf J.D., de Graaf F.R., et al. Diagnostic performance of non-invasive multidetector computed tomography coronary angiography to detect coronary artery disease using different endpoints: detection of significant stenosis vs detection of atherosclerosis. Eur Heart J 2010.
    • (2010) Eur Heart J
    • van Velzen, J.E.1    Schuijf, J.D.2    de Graaf, F.R.3
  • 27
    • 67651236667 scopus 로고    scopus 로고
    • Comparison of multislice computed tomography with intravascular ultrasound for detection and characterization of coronary artery plaques: a systematic review
    • Springer I., Dewey M. Comparison of multislice computed tomography with intravascular ultrasound for detection and characterization of coronary artery plaques: a systematic review. Eur J Radiol 2009, 71:275-282.
    • (2009) Eur J Radiol , vol.71 , pp. 275-282
    • Springer, I.1    Dewey, M.2
  • 28
    • 12344299169 scopus 로고    scopus 로고
    • Detection of coronary plaque by computed tomography with a novel plaque analysis system, 'plaque map', and comparison with intravascular ultrasound and angioscopy
    • Komatsu S., Hirayama A., Omori Y., et al. Detection of coronary plaque by computed tomography with a novel plaque analysis system, 'plaque map', and comparison with intravascular ultrasound and angioscopy. Circ J 2005, 69:72-77.
    • (2005) Circ J , vol.69 , pp. 72-77
    • Komatsu, S.1    Hirayama, A.2    Omori, Y.3
  • 30
    • 0141459321 scopus 로고    scopus 로고
    • Coronary plaque burden detected by multislice computed tomography after acute myocardial infarction with near-normal coronary arteries by angiography
    • Caussin C., Ohanessian A., Lancelin B., et al. Coronary plaque burden detected by multislice computed tomography after acute myocardial infarction with near-normal coronary arteries by angiography. Am J Cardiol 2003, 92:849-852.
    • (2003) Am J Cardiol , vol.92 , pp. 849-852
    • Caussin, C.1    Ohanessian, A.2    Lancelin, B.3
  • 31
    • 59749092047 scopus 로고    scopus 로고
    • Prognostic value of multislice computed tomography and gated single-photon emission computed tomography in patients with suspected coronary artery disease
    • van Werkhoven J.M., Schuijf J.D., Gaemperli O., et al. Prognostic value of multislice computed tomography and gated single-photon emission computed tomography in patients with suspected coronary artery disease. J Am Coll Cardiol 2009, 53:623-632.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 623-632
    • van Werkhoven, J.M.1    Schuijf, J.D.2    Gaemperli, O.3
  • 32
    • 33845879359 scopus 로고    scopus 로고
    • Prognostic value of multislice computed tomography coronary angiography in patients with known or suspected coronary artery disease
    • Pundziute G., Schuijf J.D., Jukema J.W., et al. Prognostic value of multislice computed tomography coronary angiography in patients with known or suspected coronary artery disease. J Am Coll Cardiol 2007, 49:62-70.
    • (2007) J Am Coll Cardiol , vol.49 , pp. 62-70
    • Pundziute, G.1    Schuijf, J.D.2    Jukema, J.W.3
  • 33
    • 70349774691 scopus 로고    scopus 로고
    • Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation
    • Dewey M., Zimmermann E., Deissenrieder F., et al. Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation 2009, 120:867-875.
    • (2009) Circulation , vol.120 , pp. 867-875
    • Dewey, M.1    Zimmermann, E.2    Deissenrieder, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.