메뉴 건너뛰기




Volumn 71, Issue 2, 2009, Pages 275-282

Comparison of multislice computed tomography with intravascular ultrasound for detection and characterization of coronary artery plaques: A systematic review

Author keywords

Computed tomography; Coronary artery disease; Coronary atherosclerosis; Intravascular ultrasound

Indexed keywords

COMPUTED TOMOGRAPHY; CORONARY ARTERIES; CORONARY ARTERY DISEASE; CORONARY ATHEROSCLEROSIS; CROSS-SECTION ANALYSIS; INCOMPLETE DATA; INTRAVASCULAR ULTRASOUND; LITERATURE SEARCH; MEAN AGES; MEDLINE; MULTISLICE COMPUTED TOMOGRAPHY; NON-INVASIVE; ONLINE DATABASE; RADIATION EXPOSURE; REFERENCE STANDARD; SAMPLE SIZES; SENSITIVITY AND SPECIFICITY; SYSTEMATIC REVIEW;

EID: 67651236667     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejrad.2008.04.035     Document Type: Review
Times cited : (49)

References (42)
  • 1
    • 2942748335 scopus 로고    scopus 로고
    • Coronary artery disease: new insights and their implications for radiology
    • Dewey M., Borges A.C., Kivelitz D., et al. Coronary artery disease: new insights and their implications for radiology. Eur Radiol 14 (2004) 1048-1054
    • (2004) Eur Radiol , vol.14 , pp. 1048-1054
    • Dewey, M.1    Borges, A.C.2    Kivelitz, D.3
  • 2
    • 0035954283 scopus 로고    scopus 로고
    • Evaluation of the culprit plaque and the physiological significance of coronary atherosclerotic narrowings
    • Kern M.J., and Meier B. Evaluation of the culprit plaque and the physiological significance of coronary atherosclerotic narrowings. Circulation 103 (2001) 3142-3149
    • (2001) Circulation , vol.103 , pp. 3142-3149
    • Kern, M.J.1    Meier, B.2
  • 3
    • 0029090411 scopus 로고
    • Coronary plaque disruption
    • Falk E., Shah P.K., and Fuster V. Coronary plaque disruption. Circulation 92 (1995) 657-671
    • (1995) Circulation , vol.92 , pp. 657-671
    • Falk, E.1    Shah, P.K.2    Fuster, V.3
  • 5
    • 14544283354 scopus 로고    scopus 로고
    • Applikationen und Limitationen der Mehrschicht-Computertomographie in der kardialen Bildgebung: Erfahrungen aus der Praxis
    • Feuchtner G., and Friedrich G. Applikationen und Limitationen der Mehrschicht-Computertomographie in der kardialen Bildgebung: Erfahrungen aus der Praxis. J Kardiol 12 (2005) 1-2
    • (2005) J Kardiol , vol.12 , pp. 1-2
    • Feuchtner, G.1    Friedrich, G.2
  • 6
    • 0037368737 scopus 로고    scopus 로고
    • Angio-CT: heart and coronary arteries
    • Kopp A.F. Angio-CT: heart and coronary arteries. Eur J Radiol 45 Suppl 1 (2003) S32-S36
    • (2003) Eur J Radiol , vol.45 , Issue.SUPPL. 1
    • Kopp, A.F.1
  • 7
    • 11144354420 scopus 로고    scopus 로고
    • Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound
    • Leber A.W., Knez A., Becker A., et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol 43 (2004) 1241-1247
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1241-1247
    • Leber, A.W.1    Knez, A.2    Becker, A.3
  • 8
    • 0035312512 scopus 로고    scopus 로고
    • Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography
    • Schroeder S., Kopp A.F., Baumbach A., et al. Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol 37 (2001) 1430-1435
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1430-1435
    • Schroeder, S.1    Kopp, A.F.2    Baumbach, A.3
  • 9
    • 0034839070 scopus 로고    scopus 로고
    • Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound
    • Kopp A.F., Schroeder S., Baumbach A., et al. Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound. Eur Radiol 11 (2001) 1607-1611
    • (2001) Eur Radiol , vol.11 , pp. 1607-1611
    • Kopp, A.F.1    Schroeder, S.2    Baumbach, A.3
  • 10
    • 10744220384 scopus 로고    scopus 로고
    • Non-invasive assessment of plaque morphology and remodeling in mildly stenotic coronary segments: comparison of 16-slice computed tomography and intravascular ultrasound
    • Schoenhagen P., Tuzcu E.M., Stillman A.E., et al. Non-invasive assessment of plaque morphology and remodeling in mildly stenotic coronary segments: comparison of 16-slice computed tomography and intravascular ultrasound. Coron Artery Dis 14 (2003) 459-462
    • (2003) Coron Artery Dis , vol.14 , pp. 459-462
    • Schoenhagen, P.1    Tuzcu, E.M.2    Stillman, A.E.3
  • 11
    • 12344299169 scopus 로고    scopus 로고
    • Detection of coronary plaque by computed tomography with a novel plaque analysis system, 'Plaque Map', and comparison with intravascular ultrasound and angioscopy
    • Komatsu S., Hirayama A., Omori Y., et al. Detection of coronary plaque by computed tomography with a novel plaque analysis system, 'Plaque Map', and comparison with intravascular ultrasound and angioscopy. Circ J 69 (2005) 72-77
    • (2005) Circ J , vol.69 , pp. 72-77
    • Komatsu, S.1    Hirayama, A.2    Omori, Y.3
  • 12
    • 0141459321 scopus 로고    scopus 로고
    • Coronary plaque burden detected by multislice computed tomography after acute myocardial infarction with near-normal coronary arteries by angiography
    • Caussin C., Ohanessian A., Lancelin B., et al. Coronary plaque burden detected by multislice computed tomography after acute myocardial infarction with near-normal coronary arteries by angiography. Am J Cardiol 92 (2003) 849-852
    • (2003) Am J Cardiol , vol.92 , pp. 849-852
    • Caussin, C.1    Ohanessian, A.2    Lancelin, B.3
  • 13
    • 0037325761 scopus 로고    scopus 로고
    • General utilities of multislice tomography in the cardiac field
    • Carrascosa P.M., Capunay C.M., Parodi J.C., et al. General utilities of multislice tomography in the cardiac field. Herz 28 (2003) 44-51
    • (2003) Herz , vol.28 , pp. 44-51
    • Carrascosa, P.M.1    Capunay, C.M.2    Parodi, J.C.3
  • 15
    • 0347357884 scopus 로고    scopus 로고
    • Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound
    • Achenbach S., Moselewski F., Ropers D., et al. Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound. Circulation 109 (2004) 14-17
    • (2004) Circulation , vol.109 , pp. 14-17
    • Achenbach, S.1    Moselewski, F.2    Ropers, D.3
  • 16
    • 3042660302 scopus 로고    scopus 로고
    • Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular ultrasound
    • Caussin C., Ohanessian A., Ghostine S., et al. Characterization of vulnerable nonstenotic plaque with 16-slice computed tomography compared with intravascular ultrasound. Am J Cardiol 94 (2004) 99-104
    • (2004) Am J Cardiol , vol.94 , pp. 99-104
    • Caussin, C.1    Ohanessian, A.2    Ghostine, S.3
  • 17
    • 21344460533 scopus 로고    scopus 로고
    • Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound
    • Leber A.W., Knez A., von Ziegler F., et al. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46 (2005) 147-154
    • (2005) J Am Coll Cardiol , vol.46 , pp. 147-154
    • Leber, A.W.1    Knez, A.2    von Ziegler, F.3
  • 18
    • 31644449398 scopus 로고    scopus 로고
    • Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound
    • Leber A.W., Becker A., Knez A., et al. Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol 47 (2006) 672-677
    • (2006) J Am Coll Cardiol , vol.47 , pp. 672-677
    • Leber, A.W.1    Becker, A.2    Knez, A.3
  • 19
    • 7944224889 scopus 로고    scopus 로고
    • Comparison of measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multidetector computed tomography versus intravascular ultrasound
    • Moselewski F., Ropers D., Pohle K., et al. Comparison of measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multidetector computed tomography versus intravascular ultrasound. Am J Cardiol 94 (2004) 1294-1297
    • (2004) Am J Cardiol , vol.94 , pp. 1294-1297
    • Moselewski, F.1    Ropers, D.2    Pohle, K.3
  • 20
    • 33750855856 scopus 로고    scopus 로고
    • Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: comparison to IVUS
    • Pohle K., Achenbach S., Macneill B., et al. Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: comparison to IVUS. Atherosclerosis (2006)
    • (2006) Atherosclerosis
    • Pohle, K.1    Achenbach, S.2    Macneill, B.3
  • 21
    • 33644514624 scopus 로고    scopus 로고
    • New imaging techniques for diagnosing coronary artery disease
    • Escolar E., Weigold G., Fuisz A., and Weissman N.J. New imaging techniques for diagnosing coronary artery disease. CMAJ 174 (2006) 487-495
    • (2006) CMAJ , vol.174 , pp. 487-495
    • Escolar, E.1    Weigold, G.2    Fuisz, A.3    Weissman, N.J.4
  • 22
    • 33646047719 scopus 로고    scopus 로고
    • Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography
    • Hoffmann U., Moselewski F., Nieman K., et al. Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography. J Am Coll Cardiol 47 (2006) 1655-1662
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1655-1662
    • Hoffmann, U.1    Moselewski, F.2    Nieman, K.3
  • 23
    • 10744227532 scopus 로고    scopus 로고
    • Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography
    • Achenbach S., Ropers D., Hoffmann U., et al. Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography. J Am Coll Cardiol 43 (2004) 842-847
    • (2004) J Am Coll Cardiol , vol.43 , pp. 842-847
    • Achenbach, S.1    Ropers, D.2    Hoffmann, U.3
  • 24
    • 0028893411 scopus 로고
    • The safety of intracoronary ultrasound A multicenter survey of 2207 examinations
    • Hausmann D., Erbel R., Alibelli-Chemarin M.J., et al. The safety of intracoronary ultrasound A multicenter survey of 2207 examinations. Circulation 91 (1995) 623-630
    • (1995) Circulation , vol.91 , pp. 623-630
    • Hausmann, D.1    Erbel, R.2    Alibelli-Chemarin, M.J.3
  • 25
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • Einstein A.J., Henzlova M.J., and Rajagopalan S. Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. JAMA 298 (2007) 317-323
    • (2007) JAMA , vol.298 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 26
    • 0033133411 scopus 로고    scopus 로고
    • ACC/AHA guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography). Developed in collaboration with the Society for Cardiac Angiography and Interventions
    • Scanlon P.J., Faxon D.P., Audet A.M., et al. ACC/AHA guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography). Developed in collaboration with the Society for Cardiac Angiography and Interventions. J Am Coll Cardiol 33 (1999) 1756-1824
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1756-1824
    • Scanlon, P.J.1    Faxon, D.P.2    Audet, A.M.3
  • 27
    • 0037254248 scopus 로고    scopus 로고
    • Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT
    • Hunold P., Vogt F.M., Schmermund A., et al. Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. Radiology 226 (2003) 145-152
    • (2003) Radiology , vol.226 , pp. 145-152
    • Hunold, P.1    Vogt, F.M.2    Schmermund, A.3
  • 28
    • 0041322599 scopus 로고    scopus 로고
    • Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating
    • Trabold T., Buchgeister M., Kuettner A., et al. Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. Roefo 175 (2003) 1051-1055
    • (2003) Roefo , vol.175 , pp. 1051-1055
    • Trabold, T.1    Buchgeister, M.2    Kuettner, A.3
  • 29
    • 33646201890 scopus 로고    scopus 로고
    • Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography
    • Coles D.R., Smail M.A., Negus I.S., et al. Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography. J Am Coll Cardiol 47 (2006) 1840-1845
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1840-1845
    • Coles, D.R.1    Smail, M.A.2    Negus, I.S.3
  • 30
    • 33749174732 scopus 로고    scopus 로고
    • Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging
    • Dewey M., Teige F., Schnapauff D., et al. Noninvasive detection of coronary artery stenoses with multislice computed tomography or magnetic resonance imaging. Ann Intern Med 145 (2006) 407-415
    • (2006) Ann Intern Med , vol.145 , pp. 407-415
    • Dewey, M.1    Teige, F.2    Schnapauff, D.3
  • 31
    • 34447310641 scopus 로고    scopus 로고
    • CT coronary angiography using 16 and 64 simultaneous detector rows: intraindividual comparison
    • Dewey M., Hoffmann H., and Hamm B. CT coronary angiography using 16 and 64 simultaneous detector rows: intraindividual comparison. Rofo 179 (2007) 581-586
    • (2007) Rofo , vol.179 , pp. 581-586
    • Dewey, M.1    Hoffmann, H.2    Hamm, B.3
  • 32
    • 0242267947 scopus 로고    scopus 로고
    • Summarizing studies of diagnostic test performance
    • Montori V.M., and Guyatt G.H. Summarizing studies of diagnostic test performance. Clin Chem 49 (2003) 1783-1784
    • (2003) Clin Chem , vol.49 , pp. 1783-1784
    • Montori, V.M.1    Guyatt, G.H.2
  • 33
    • 17044373110 scopus 로고    scopus 로고
    • Meta-analysis and structured literature review in radiology
    • Doria A.S. Meta-analysis and structured literature review in radiology. Acad Radiol 12 (2005) 399-408
    • (2005) Acad Radiol , vol.12 , pp. 399-408
    • Doria, A.S.1
  • 34
    • 13244255249 scopus 로고    scopus 로고
    • Volumetric cine imaging for cardiovascular circulation using prototype 256-detector row computed tomography scanner (4-dimensional computed tomography): a preliminary study with a porcine model
    • Mori S., Kondo C., Suzuki N., et al. Volumetric cine imaging for cardiovascular circulation using prototype 256-detector row computed tomography scanner (4-dimensional computed tomography): a preliminary study with a porcine model. J Comput Assist Tomogr 29 (2005) 26-30
    • (2005) J Comput Assist Tomogr , vol.29 , pp. 26-30
    • Mori, S.1    Kondo, C.2    Suzuki, N.3
  • 35
    • 18544396616 scopus 로고    scopus 로고
    • Development of a 3D CT-scanner using a cone beam and video-fluoroscopic system
    • Endo M., Yoshida K., Kamagata N., et al. Development of a 3D CT-scanner using a cone beam and video-fluoroscopic system. Radiat Med 16 (1998) 7-12
    • (1998) Radiat Med , vol.16 , pp. 7-12
    • Endo, M.1    Yoshida, K.2    Kamagata, N.3
  • 36
    • 41049103903 scopus 로고    scopus 로고
    • Effective doses in subjects undergoing computed tomography cardiac imaging with the 256-multislice CT scanner
    • Mori S., Nishizawa K., Kondo C., Ohno M., Akahane K., and Endo M. Effective doses in subjects undergoing computed tomography cardiac imaging with the 256-multislice CT scanner. Eur J Radiol (2007)
    • (2007) Eur J Radiol
    • Mori, S.1    Nishizawa, K.2    Kondo, C.3    Ohno, M.4    Akahane, K.5    Endo, M.6
  • 37
    • 32844464236 scopus 로고    scopus 로고
    • Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience
    • Achenbach S., Ropers D., Kuettner A., et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience. Eur J Radiol 57 (2006) 331-335
    • (2006) Eur J Radiol , vol.57 , pp. 331-335
    • Achenbach, S.1    Ropers, D.2    Kuettner, A.3
  • 38
    • 35148867562 scopus 로고    scopus 로고
    • Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease
    • Leber A.W., Johnson T., Becker A., et al. Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease. Eur Heart J 28 (2007) 2354-2360
    • (2007) Eur Heart J , vol.28 , pp. 2354-2360
    • Leber, A.W.1    Johnson, T.2    Becker, A.3
  • 39
    • 34547783961 scopus 로고    scopus 로고
    • Usefulness of noninvasive cardiac imaging using dual-source computed tomography in an unselected population with high prevalence of coronary artery disease
    • Heuschmid M., Burgstahler C., Reimann A., et al. Usefulness of noninvasive cardiac imaging using dual-source computed tomography in an unselected population with high prevalence of coronary artery disease. Am J Cardiol 100 (2007) 587-592
    • (2007) Am J Cardiol , vol.100 , pp. 587-592
    • Heuschmid, M.1    Burgstahler, C.2    Reimann, A.3
  • 40
    • 1642351485 scopus 로고    scopus 로고
    • Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses
    • Dewey M., Laule M., Krug L., et al. Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses. Invest Radiol 39 (2004) 223-229
    • (2004) Invest Radiol , vol.39 , pp. 223-229
    • Dewey, M.1    Laule, M.2    Krug, L.3
  • 41
    • 0041826862 scopus 로고    scopus 로고
    • Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT
    • Becker C.R., Nikolaou K., Muders M., et al. Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT. Eur Radiol 13 (2003) 2094-2098
    • (2003) Eur Radiol , vol.13 , pp. 2094-2098
    • Becker, C.R.1    Nikolaou, K.2    Muders, M.3
  • 42
    • 41049096079 scopus 로고    scopus 로고
    • Three-vessel coronary artery disease examined with 320-slice computed tomography coronary angiography
    • epub
    • Dewey M, Zimmermann E, Laule M, Rutsch W, Hamm B. Three-vessel coronary artery disease examined with 320-slice computed tomography coronary angiography. Eur Heart J 2008; epub.
    • (2008) Eur Heart J
    • Dewey, M.1    Zimmermann, E.2    Laule, M.3    Rutsch, W.4    Hamm, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.