메뉴 건너뛰기




Volumn 27, Issue 4, 2011, Pages 255-268

Ultrasound-guided biopsies of the abdomen

Author keywords

biopsy; biopsy abdomen; biopsy pelvis; fine needle aspiration; ultrasound; ultrasound guided biopsies

Indexed keywords

ABDOMINAL DISEASE; ABDOMINAL WALL; ASPIRATION BIOPSY; BLOOD CLOTTING; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; HUMAN; IONIZING RADIATION; PELVIS; PERCUTANEOUS BIOPSY; PRIORITY JOURNAL; REAL TIME ECHOGRAPHY; RETROPERITONEUM; REVIEW; SAFETY; ULTRASOUND;

EID: 82455174545     PISSN: 08948771     EISSN: 15360253     Source Type: Journal    
DOI: 10.1097/RUQ.0b013e3182394101     Document Type: Review
Times cited : (34)

References (79)
  • 1
    • 0023907217 scopus 로고
    • Sonographically guided percutaneous biopsy of small (3 cm or less) masses
    • Reading CC, Charboneau JW, James EM, et al. Sonographically guided percutaneous biopsy of small (3 cm or less) masses. AJR Am J Roentgenol. 1988;151:189-192.
    • (1988) AJR Am J Roentgenol , vol.151 , pp. 189-192
    • Reading, C.C.1    Charboneau, J.W.2    James, E.M.3
  • 2
    • 0025261269 scopus 로고
    • Major complications and deaths due to interventional ultrasonography: A review of 8000 cases
    • NolsLe C, Nielsen L, Torp-Pedersen S, et al. Major complications and deaths due to interventional ultrasonography: a review of 8000 cases. J Clin Ultrasound. 1990;18:179-184. (Pubitemid 20097632)
    • (1990) Journal of Clinical Ultrasound , vol.18 , Issue.3 , pp. 179-184
    • Nolsoe, C.1    Nielsen, L.2    Torp-Pedersen, S.3    Holm, H.H.4
  • 3
    • 0035130934 scopus 로고    scopus 로고
    • US-guided percutaneous biopsy of small (≤1-cm) hepatic lesions
    • Yu SC, Liew CT, Lau WY, et al. US-guide percutaneous biopsy of small (G or = 1-cm) hepatic lesions. Radiology. 2001;218(1):195-199. (Pubitemid 32151294)
    • (2001) Radiology , vol.218 , Issue.1 , pp. 195-199
    • Yu, S.C.H.1    Liew, C.T.2    Lau, W.Y.3    Leung, T.W.4    Metreweli, C.5
  • 5
    • 67649823467 scopus 로고    scopus 로고
    • Consensus guidelines for periprocedural management of coagulation status and hemostasis risk in percutaneous image-guided interventions
    • Malloy PC, Grassi CJ, Kundu S, et al. Consensus guidelines for periprocedural management of coagulation status and hemostasis risk in percutaneous image-guided interventions. J Vasc Interv Radiol. 2009:20:S240-S249.
    • (2009) J Vasc Interv Radiol , vol.20
    • Malloy, P.C.1    Grassi, C.J.2    Kundu, S.3
  • 7
    • 77749298675 scopus 로고    scopus 로고
    • Incidence of bleeding after 15,181 percutaneous biopsies and the role of aspirin
    • Atwell TD, Smith RL, Hesley GK, et al. Incidence of bleeding after 15,181 percutaneous biopsies and the role of Aspirin. AJR Am J Roentgenol. 2010;194:784-789.
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 784-789
    • Atwell, T.D.1    Smith, R.L.2    Hesley, G.K.3
  • 9
    • 41849122254 scopus 로고    scopus 로고
    • Ultrasound-guided biopsies in the abdomen and pelvis
    • DOI 10.1097/RUQ.0b013e318168c869, PII 0001364420080300000026
    • Winter TC, Lee FT, Hinshaw JL. Ultrasound-guided biopsies in the abdomen and pelvis. Ultrasound Q. 2008;24:45-68. (Pubitemid 351499324)
    • (2008) Ultrasound Quarterly , vol.24 , Issue.1 , pp. 45-68
    • Winter, T.C.1    Lee Jr., F.T.2    Hinshaw, J.L.3
  • 10
    • 1842423453 scopus 로고    scopus 로고
    • Antiplatelet drug discontinuation is a risk factor for ischemic stroke
    • Sibon I, Orgogozo JM. Antiplatelet drug discontinuation is a risk factor for ischemic stroke. Neurology. 2004;62:1187-1189. (Pubitemid 38456516)
    • (2004) Neurology , vol.62 , Issue.7 , pp. 1187-1189
    • Sibon, I.1    Orgogozo, J.-M.2
  • 11
    • 23844481806 scopus 로고    scopus 로고
    • Effect of discontinuing aspirin therapy on the risk of brain ischemic stroke
    • DOI 10.1001/archneur.62.8.1217
    • Maulaz AB, Bezerra DC, Michael P, et al. Effect of discontinuing aspirin therapy on the risk of brain ischemic stroke. Arch Neurol. 2005;62:1217-1220. (Pubitemid 41168347)
    • (2005) Archives of Neurology , vol.62 , Issue.8 , pp. 1217-1220
    • Maulaz, A.B.1    Bezerra, D.C.2    Michel, P.3    Bogousslavsky, J.4
  • 12
  • 13
    • 0038649821 scopus 로고    scopus 로고
    • Role of fresh frozen plasma infusion in correction of coagulopathy of chronic liver disease: A dual phase study
    • DOI 10.1111/j.1572-0241.2003.07467.x
    • Youssef WI, Salazar F, Dasarathy S, et al. Role of fresh frozen plasma infusion in correction of coagulopathy of chronic liver disease: a dual-phase study. Am J Gastroenterol. 2003;98(6):1391-1394. (Pubitemid 36741539)
    • (2003) American Journal of Gastroenterology , vol.98 , Issue.6 , pp. 1391-1394
    • Youssef, W.I.1    Salazar, F.2    Dasarathy, S.3    Beddow, T.4    Mullen, K.D.5
  • 14
    • 33746356507 scopus 로고    scopus 로고
    • Effect of fresh-frozen plasma transfusion on prothrombin time and bleeding in patients with mild coagulation abnormalities
    • DOI 10.1111/j.1537-2995.2006.00891.x
    • Abdel-Wahab OI, Healy B, Dzik WH. Effects of fresh-frozen plasma transfusion on prothrombin time and bleeding in patients with mild coagulation abnormalities. Transfusion. 2006;46(8):1279-1285. (Pubitemid 44117952)
    • (2006) Transfusion , vol.46 , Issue.8 , pp. 1279-1285
    • Abdel-Wahab, O.I.1    Healy, B.2    Dzik, W.H.3
  • 16
    • 0034039480 scopus 로고    scopus 로고
    • Interventional radiologic procedures: Patient anxiety, perception of pain, understanding of procedure, and satisfaction with medication - A prospective study
    • Mueller PR, Biswal S, Halpern EF, et al. Interventional radiologic procedures: patient anxiety, perception of pain, understanding of procedure, and satisfaction with medicationVa prospective study. Radiology. 2000;215:684-688. (Pubitemid 30346000)
    • (2000) Radiology , vol.215 , Issue.3 , pp. 684-688
    • Mueller, P.R.1    Biswal, S.2    Halpern, E.F.3    Kaufman, J.A.4    Lee, M.J.5
  • 17
    • 77955219707 scopus 로고    scopus 로고
    • Minimizing wound contamination in a "clean" surgery: Comparison of chlorhexidine-ethanol and povidone-iodine
    • Sistla SC, Prabhu G, Sistla S, et al. Minimizing wound contamination in a "clean" surgery: comparison of chlorhexidine-ethanol and povidone-iodine. Chemotherapy. 2010;56:261-267.
    • (2010) Chemotherapy , vol.56 , pp. 261-267
    • Sistla, S.C.1    Prabhu, G.2    Sistla, S.3
  • 18
    • 78049385326 scopus 로고    scopus 로고
    • Systematic review and meta-analysis of preoperative antisepsis with chlorhexidine versus povidone-iodine in clean-contaminated surgery
    • Noorani A, Rabey N, Walsh SR, et al. Systematic review and meta-analysis of preoperative antisepsis with chlorhexidine versus povidone-iodine in clean-contaminated surgery. Br J Surg. 2010;97:1614-1620.
    • (2010) Br J Surg , vol.97 , pp. 1614-1620
    • Noorani, A.1    Rabey, N.2    Walsh, S.R.3
  • 19
    • 74049114688 scopus 로고    scopus 로고
    • Chlorhexidine-alcohol versus povidone-iodine for surgical-site antisepsis
    • Darouiche RO, Wall MJ, Itani KM, et al. Chlorhexidine-alcohol versus povidone-iodine for surgical-site antisepsis. N Engl J Med. 2010;362:18-26.
    • (2010) N Engl J Med , vol.362 , pp. 18-26
    • Darouiche, R.O.1    Wall, M.J.2    Itani, K.M.3
  • 20
    • 0031012395 scopus 로고    scopus 로고
    • Use of a needle-vibrating device and color Doppler imaging for sonographically guided invasive procedures
    • Feld R, Needleman L, Goldberg BB. Use of needle-vibrating device and color Doppler imaging for sonographically guided invasive procedures. AJR Am J Roentgenol. 1997;168:255-256. (Pubitemid 27014784)
    • (1997) American Journal of Roentgenology , vol.168 , Issue.1 , pp. 255-256
    • Feld, R.1    Needleman, L.2    Goldberg, B.B.3
  • 21
    • 0025179433 scopus 로고
    • The pump maneuver: An atraumatic adjunct to enhance US needle tip localization
    • Bisceglia M, Matalon TA, Silver B. The pump maneuver: an atraumatic adjunct to enhance US needle tip localization. Radiology. 1990;176:867-868. (Pubitemid 20266789)
    • (1990) Radiology , vol.176 , Issue.3 , pp. 867-868
    • Bisceglia, M.1    Matalon, T.A.S.2    Silver, B.3
  • 22
    • 0026090732 scopus 로고
    • Improved needle-tip visualization by color doppler sonography
    • Hamper UM, Svader BL, Sheth S. Improved needle-tip visualization by color Doppler sonography. AJR Am J Roentgenol. 1990;156:401-402.
    • (1990) AJR Am J Roentgenol , vol.156 , pp. 401-402
    • Hamper, U.M.1    Svader, B.L.2    Sheth, S.3
  • 26
    • 79952259454 scopus 로고    scopus 로고
    • Accuracy and safety of percutaneous us-guided needle biopsies liver metastasis and hemangiomas
    • Arabas KB, Dingil G, Ungul U, et al. Accuracy and safety of percutaneous US-guided needle biopsies liver metastasis and hemangiomas. Minerva Gastroenterol Dietol. 2010;56:377-382.
    • (2010) Minerva Gastroenterol Dietol , vol.56 , pp. 377-382
    • Arabas, K.B.1    Dingil, G.2    Ungul, U.3
  • 27
    • 0029080789 scopus 로고
    • Multiple fine-needle biopsies using a coaxial technique: Efficacy and a comparison of three methods
    • Hopper KD, Abendroth CS, TenHave TR, et al. Multiple fine-needle biopsies using a coaxial technique: efficacy and a comparison of three methods. Cardiovasc Intervent Radiol. 1995;18:307-311.
    • (1995) Cardiovasc Intervent Radiol , vol.18 , pp. 307-311
    • Hopper, K.D.1    Abendroth, C.S.2    Tenhave, T.R.3
  • 28
    • 22944440986 scopus 로고    scopus 로고
    • A comparative study of fine needle aspiration cytology versus non-aspiration technique in thyroid lesions
    • Rizvi SA, Husain M, Khan S, et al. A comparative study of fine needle aspiration cytology versus non-aspiration technique in thyroid lesions. Surgeon. 2005;3:273-276. (Pubitemid 41051556)
    • (2005) Surgeon , vol.3 , Issue.4 , pp. 273-276
    • Ali Rizvi, S.A.1    Husain, M.2    Khan, S.3    Mohsin, M.4
  • 29
    • 0025607879 scopus 로고
    • Non-aspiration fine-needle cytology of the liver: A new technique for obtaining diagnostic samples
    • Fagelman D, Chess Q. Non-aspiration fine-needle cytology of the liver: a new technique for obtaining diagnostic samples. AJR Am J Roentgenol. 1990;155:1217-1219.
    • (1990) AJR Am J Roentgenol , vol.155 , pp. 1217-1219
    • Fagelman, D.1    Chess, Q.2
  • 30
    • 65949111752 scopus 로고    scopus 로고
    • Percutaneous liver biopsy: Retrospective study over 15 years comparing 287 inpatients with 428 outpatients
    • Weigand K. Percutaneous liver biopsy: retrospective study over 15 years comparing 287 inpatients with 428 outpatients. J Gastroenterol Hepatol. 2009;792-799.
    • (2009) J Gastroenterol Hepatol , pp. 792-799
    • Weigand, K.1
  • 34
    • 38849107630 scopus 로고    scopus 로고
    • Percutaneous imaging-guided solid organ core needle biopsy: Coaxial versus noncoaxial method
    • DOI 10.2214/AJR.07.2676
    • Hatfield MK, Beres RA, Sane SS, et al. Percutaneous imaging-guided solid organ core needle biopsy: axial versus nonaxial method. AJR Am J Roentgenol. 2008;190:413-417. (Pubitemid 351196612)
    • (2008) American Journal of Roentgenology , vol.190 , Issue.2 , pp. 413-417
    • Hatfield, M.K.1    Beres, R.A.2    Sane, S.S.3    Zaleski, G.X.4
  • 35
    • 0036923692 scopus 로고    scopus 로고
    • Complications after percutaneous liver biopsy in diffuse hepatopathies
    • Sparchez Z. Complications after percutaneous liver biopsy in diffuse hepatopathies. Rom J Gastroenterol. 2002;11:335-341.
    • (2002) Rom J Gastroenterol , vol.11 , pp. 335-341
    • Sparchez, Z.1
  • 37
    • 75449116365 scopus 로고    scopus 로고
    • Percutaneous transgastric computed tomographyyguided biopsy of the pancreas using large needles
    • Tseng HS, Chen CY, Chan WP, et al. Percutaneous transgastric computed tomographyYguided biopsy of the pancreas using large needles. World J Gastroenterol. 2009;15:5972-5975.
    • (2009) World J Gastroenterol , vol.15 , pp. 5972-5975
    • Tseng, H.S.1    Chen, C.Y.2    Chan, W.P.3
  • 38
    • 0027403842 scopus 로고
    • CT-and us-guided biopsy of the pancreas
    • Brandt KR, Charboneau WJ, Stephens DH, et al. CT-and US-guided biopsy of the pancreas. Radiology. 1993;187(1):99-104.
    • (1993) Radiology , vol.187 , Issue.1 , pp. 99-104
    • Brandt, K.R.1    Charboneau, W.J.2    Stephens, D.H.3
  • 40
    • 41749106920 scopus 로고    scopus 로고
    • Ultrasound-guided percutaneous pancreatic tumor biopsy in pancreatic cancer: A comparison with metastatic liver tumor biopsy, including sensitivity, specificity, and complications
    • DOI 10.1007/s00535-007-2142-9
    • Matsubara J, Okusaka T, Morizane C, et al. Ultrasound-guided percutaneous pancreatic tumor biopsy in pancreatic cancer: a comparison with metastatic liver tumor biopsy, including sensitivity, specificity, and complications. J Gastroenterol. 2008;43:225-232. (Pubitemid 351486684)
    • (2008) Journal of Gastroenterology , vol.43 , Issue.3 , pp. 225-232
    • Matsubara, J.1    Okusaka, T.2    Morizane, C.3    Ikeda, M.4    Ueno, H.5
  • 41
    • 0025961782 scopus 로고
    • Pancreatic cancer versus chronic pancreatitis: Diagnosis with CA 19-9 assessment, us, CT and ct-guided fine-needle biopsy
    • DelMaschio A, Vanzulli A, Sironi S, et al. Pancreatic cancer versus chronic pancreatitis: diagnosis with CA 19-9 assessment, US, CT and CT-guided fine-needle biopsy. Radiology. 1991;178:95-99.
    • (1991) Radiology , vol.178 , pp. 95-99
    • Delmaschio, A.1    Vanzulli, A.2    Sironi, S.3
  • 42
    • 0025072552 scopus 로고
    • Biopsy of the pancreas with a biopsy gun
    • Elvin A, Anderson T, Scheibenpflug L, et al. Biopsy of the pancreas with a biopsy gun. Radiology. 1990;176:615-616.
    • (1990) Radiology , vol.176 , pp. 615-616
    • Elvin, A.1    Anderson, T.2    Scheibenpflug, L.3
  • 45
    • 73449124470 scopus 로고    scopus 로고
    • Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions
    • Zamboni GA, D'Onofrio M, Idili A, et al. Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions. AJR Am J Roentgenol. 2009;193:1691-1695.
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 1691-1695
    • Zamboni, G.A.1    D'Onofrio, M.2    Idili, A.3
  • 47
  • 48
    • 0036262291 scopus 로고    scopus 로고
    • Subcutaneous needle-tract seeding after fine needle aspiration biopsy of pancreatic liver metastasis
    • DOI 10.1016/S0929-8266(02)00008-3, PII S0929826602000083
    • de Sio I, Castellano L, Clandra M, et al. Subcutaneous needle-tract seeding after fine needle aspiration biopsy of pancreatic liver metastasis. Eur J Ultrasound. 2002;15:65-68. (Pubitemid 34578569)
    • (2002) European Journal of Ultrasound , vol.15 , Issue.1-2 , pp. 65-68
    • De Sio, I.1    Castellano, L.2    Calandra, M.3    Del Vecchio-Blanco, C.4
  • 49
    • 9144250995 scopus 로고    scopus 로고
    • Needle tract implantation of hepatocellular carcinoma and pancreatic carcinoma after ultrasound-guided percutaneous puncture: Clinical and pathologic characteristics and the treatment of needle tract implantation
    • DOI 10.1007/s00268-003-7003-y
    • Kosugi C, Furuse J, Ishii H, et al. Needle tract implantation of hepatocellular carcinoma and pancreatic carcinoma after ultrasound-guided percutaneous puncture: clinical and pathologic characteristics and the treatment of needle tract implantation. World J Surg. 2004;28:29-32. (Pubitemid 38095788)
    • (2004) World Journal of Surgery , vol.28 , Issue.1 , pp. 29-32
    • Kosugi, C.1    Furuse, J.2    Ishii, H.3    Maru, Y.4    Yoshino, M.5    Kinoshita, T.6    Konishi, M.7    Nakagohri, T.8    Inoue, K.9    Oda, T.10
  • 51
    • 33846571930 scopus 로고    scopus 로고
    • Percutaneous image-guided splenic procedures: Update on indications, technique, complications, and outcomes
    • DOI 10.1053/j.sult.2006.10.001, PII S0887217106000849
    • Lieberman S, Libson E, Sella T, et al. Percutaneous image-guided splenic procedures: update on indications, technique, complications, and outcomes. Semin Ultrasound CT MR. 2007;28:57-63. (Pubitemid 46176536)
    • (2007) Seminars in Ultrasound, CT and MRI , vol.28 , Issue.1 , pp. 57-63
    • Lieberman, S.1    Libson, E.2    Sella, T.3    Lebensart, P.4    Sosna, J.5
  • 52
    • 84860389872 scopus 로고    scopus 로고
    • Percutaneous image-guided biopsy of the spleen: Systematic review and meta-analysis of the complication rate and diagnostic accuracy
    • McInnes MD, Kielar AZ, Macdonald DB. Percutaneous image-guided biopsy of the spleen: systematic review and meta-analysis of the complication rate and diagnostic accuracy. Radiology. 2011;260(3): 699-708.
    • (2011) Radiology , vol.260 , Issue.3 , pp. 699-708
    • McInnes, M.D.1    Kielar, A.Z.2    MacDonald, D.B.3
  • 58
    • 76449097927 scopus 로고    scopus 로고
    • Percutaneous us-guided renal biopsy: A retrospective study comparing the 16-gauge end-cut and 14-gauge side-notch needles
    • Constantin A, brisson ML, Kwan J, et al. Percutaneous US-guided renal biopsy: a retrospective study comparing the 16-gauge end-cut and 14-gauge side-notch needles. J Vasc Interv Radiol. 2010;21:357-361.
    • (2010) J Vasc Interv Radiol , vol.21 , pp. 357-361
    • Constantin, A.1    Brisson, M.L.2    Kwan, J.3
  • 59
    • 69249120201 scopus 로고    scopus 로고
    • Percutaneous renal biopsy: Outpatient observation without hospitalization is safe
    • Maya ID, Allon M. Percutaneous renal biopsy: outpatient observation without hospitalization is safe. Semin Dial. 2009;22:458-461.
    • (2009) Semin Dial , vol.22 , pp. 458-461
    • Maya, I.D.1    Allon, M.2
  • 61
    • 43649087703 scopus 로고    scopus 로고
    • The incidental adrenal mass on CT: Prevalence of adrenal disease in 1,049 consecutive adrenal masses in patients with no known malignancy
    • DOI 10.2214/AJR.07.2799
    • Song JH, Chaudry FS, Mayo-Smith WW. The incidental adrenal mass on CT: prevalence of adrenal disease in 1049 consecutive adrenal masses in patients with known malignancy. AJR Am J Roentgenol. 2008;190: 1163-1168. (Pubitemid 351684914)
    • (2008) American Journal of Roentgenology , vol.190 , Issue.5 , pp. 1163-1168
    • Song, J.H.1    Chaudhry, F.S.2    Mayo-Smith, W.W.3
  • 62
    • 78649748878 scopus 로고    scopus 로고
    • Adrenal imaging: Why, when, what, and how? part 1. Why and when to image
    • Boland GW. Adrenal imaging: why, when, what, and how? Part 1. Why and when to image. AJR Am J Roentgenol. 2010;195:W377-W381.
    • (2010) AJR Am J Roentgenol , vol.195
    • Boland, G.W.1
  • 63
    • 78650812531 scopus 로고    scopus 로고
    • Adrenal imaging: Why, when, what, and how? part 2. What technique?
    • Boland GW. Adrenal imaging: why, when, what, and how? Part 2. What technique? AJR Am J Roentgenol. 2011;191:W1-W5.
    • (2011) AJR Am J Roentgenol , vol.191
    • Boland, G.W.1
  • 64
    • 79251527866 scopus 로고    scopus 로고
    • Adrenal imaging: Why, when, what, and how? part 3. The algorithmic approach to definitive characterization of the adrenal incidentaloma
    • Boland GW. Adrenal imaging: why, when, what, and how? Part 3. The algorithmic approach to definitive characterization of the adrenal incidentaloma. AJR Am J Roentgenol. 2011;195:W109-W111.
    • (2011) AJR Am J Roentgenol , vol.195
    • Boland, G.W.1
  • 65
    • 84928096355 scopus 로고    scopus 로고
    • Managing incidental findings on abdominal ct: White paper of the ACR incidental findings committee
    • Berland LL, Silverman SG, Gore RM, et al. Managing incidental findings on abdominal CT: white paper of the ACR incidental findings committee. J Am Coll Radiol. 2010;7:754-773.
    • (2010) J Am Coll Radiol , vol.7 , pp. 754-773
    • Berland, L.L.1    Silverman, S.G.2    Gore, R.M.3
  • 66
    • 82455223215 scopus 로고    scopus 로고
    • The incidentally discovered adrenal mass
    • Young WF. The incidentally discovered adrenal mass. N Engl J Med. 2007:356-601.
    • (2007) N Engl J Med , pp. 356-601
    • Young, W.F.1
  • 67
    • 0022458544 scopus 로고
    • Unsuspected pheochromocytoma: Risk of blood-pressure alterations during percutaneous adrenal biopsy
    • Casola G, Nicolet V, vanSonnenberg E, et al. Unsuspected pheochromocytoma: risk of blood-pressure alteration during percutaneous adrenal biopsy. Radiology. 1986;159:733-735. (Pubitemid 16040048)
    • (1986) Radiology , vol.159 , Issue.3 , pp. 733-735
    • Casola, G.1    Nicolet, V.2    VanSonnenberg, E.3
  • 68
    • 0021813926 scopus 로고
    • Fine-needle aspiration of catecholamine-producing adrenal masses: A possibly fatal mistake
    • McCorkell SJ, Nilesa NL. Fine needle aspiration of catecholamine- producing adrenal masses: a possible fatal mistake. AJR Am J Roentgenol. 1985;145:113-114. (Pubitemid 15022879)
    • (1985) American Journal of Roentgenology , vol.145 , Issue.1 , pp. 113-114
    • McCorkell, S.J.1    Niles, N.L.2
  • 70
    • 70549103321 scopus 로고    scopus 로고
    • Biopsy of pheochromocytomas and paragangliomas: Potential for disaster
    • Vanderveen KA, Thompson SM, Callstrom MR, et al. Biopsy of pheochromocytomas and paragangliomas: potential for disaster. Surgery. 2009;146:1158-1166.
    • (2009) Surgery , vol.146 , pp. 1158-1166
    • Vanderveen, K.A.1    Thompson, S.M.2    Callstrom, M.R.3
  • 71
    • 0030847423 scopus 로고    scopus 로고
    • Small lymph nodes of the abdomen, pelvis, and retroperitoneum: Usefulness of sonographically guided biopsy
    • Fisher AJ, Paulson EK, Sheafor DH, et al. Small lymph nodes of the abdomen, pelvis, and retroperitoneum: usefulness of sonographically guided biopsy. Radiology. 1997;205:185-190. (Pubitemid 27415146)
    • (1997) Radiology , vol.205 , Issue.1 , pp. 185-190
    • Fisher, A.J.1    Paulson, E.K.2    Sheafor, D.H.3    Simmons, C.M.4    Nelson, R.C.5
  • 72
    • 58149239942 scopus 로고    scopus 로고
    • Predictive value of percutaneous imaging-guided biopsy of peritoneal and omental masses: Results in 111 patients
    • Souza FF, Mortele KJ, Cibas ES, et al. Predictive value of percutaneous imaging-guided biopsy of peritoneal and omental masses: results in 111 patients. AJR Am J Roentgenol. 2009;192:131-136.
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 131-136
    • Souza, F.F.1    Mortele, K.J.2    Cibas, E.S.3
  • 73
    • 0038173436 scopus 로고    scopus 로고
    • Usefulness of sonographic guidance during percutaneous biopsy of mesenteric masses
    • Ho LM, Thomas J, Fine SA, et al. Usefulness of sonographic guidance during percutaneous biopsy of mesenteric masses. AJR Am J Roentgenol. 2003;180:1563-1566. (Pubitemid 36687086)
    • (2003) American Journal of Roentgenology , vol.180 , Issue.6 , pp. 1563-1566
    • Ho, L.M.1    Thomas, J.2    Fine, S.A.3    Paulson, E.K.4
  • 74
    • 78049463645 scopus 로고    scopus 로고
    • Clinical utility of image-guided peritoneal and omental biopsy
    • Spencer JA, Weston MJ, Saidi SA, et al. Clinical utility of image-guided peritoneal and omental biopsy. Nat Rev Clin Oncol. 2010;7:623-631.
    • (2010) Nat Rev Clin Oncol , vol.7 , pp. 623-631
    • Spencer, J.A.1    Weston, M.J.2    Saidi, S.A.3
  • 75
    • 0029769513 scopus 로고    scopus 로고
    • Efficacy of sonography as a guidance technique for biopsy of abdominal, pelvic, and retroperitoneal lymph nodes
    • Memel DS, Dodd GD, Esola CC. Efficacy of sonography as a guidance technique for biopsy of abdominal, pelvic, and retroperitoneal lymph nodes. AJR Am J Roentgenol. 1996;167:957-962. (Pubitemid 26322255)
    • (1996) American Journal of Roentgenology , vol.167 , Issue.4 , pp. 957-962
    • Memel, D.S.1    Dodd III, G.D.2    Esola, C.C.3
  • 77
    • 33745908234 scopus 로고    scopus 로고
    • Outpatient versus inpatient renal biopsy: A retrospective study
    • Lin WC, Yang Y, Wen YK, et al. Outpatient versus inpatient renal biopsy: a retrospective study. Clin Nephrol. 2006;66:17-24. (Pubitemid 44043728)
    • (2006) Clinical Nephrology , vol.66 , Issue.1 , pp. 17-24
    • Lin, W.C.1    Yang, Y.2    Wen, Y.K.3    Chang, C.C.4
  • 79
    • 0037148360 scopus 로고    scopus 로고
    • Short-stay, out-of-hospital, radiologically guided liver biopsy
    • Pokorny CS, Waterland M. Short-stay, out-of-hospital, radiologically guided liver biopsy. MJA. 2002;176:67-69. (Pubitemid 34116244)
    • (2002) Medical Journal of Australia , vol.176 , Issue.2 , pp. 67-69
    • Pokorny, C.S.1    Waterland, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.