메뉴 건너뛰기




Volumn 21, Issue 3, 2010, Pages 357-361

Percutaneous US-guided Renal Biopsy: A Retrospective Study Comparing the 16-gauge End-cut and 14-gauge Side-notch Needles

Author keywords

[No Author keywords available]

Indexed keywords

14 GAUGE NEEDLE; 16 GAUGE NEEDLE; ADULT; ARTICLE; BLEEDING; CLINICAL ASSESSMENT; FEMALE; GLOMERULUS; HUMAN; HUMAN TISSUE; KIDNEY BIOPSY; MAJOR CLINICAL STUDY; MALE; NEEDLE; PATIENT SAFETY; PRIORITY JOURNAL; ULTRASOUND;

EID: 76449097927     PISSN: 10510443     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvir.2009.11.005     Document Type: Article
Times cited : (36)

References (11)
  • 1
    • 0036090280 scopus 로고    scopus 로고
    • Percutaneous renal biopsy
    • Korbet S.M. Percutaneous renal biopsy. Semin Nephrol 22 (2002) 254-267
    • (2002) Semin Nephrol , vol.22 , pp. 254-267
    • Korbet, S.M.1
  • 2
    • 0025055458 scopus 로고
    • Needle biopsy of renal allografts: comparison of two techniques
    • Bogan M.L., Kopecky K.K., Kraft J.L., et al. Needle biopsy of renal allografts: comparison of two techniques. Radiology 174 (1990) 273-275
    • (1990) Radiology , vol.174 , pp. 273-275
    • Bogan, M.L.1    Kopecky, K.K.2    Kraft, J.L.3
  • 3
    • 0026734622 scopus 로고
    • Conventional 15 G needle technique for renal biopsy compared with ultrasound-guided spring-loaded 18 G needle biopsy
    • Cozens N.J., Murchison J.T., Allan P.L., and Winney R.J. Conventional 15 G needle technique for renal biopsy compared with ultrasound-guided spring-loaded 18 G needle biopsy. Br J Radiol 65 (1992) 594-597
    • (1992) Br J Radiol , vol.65 , pp. 594-597
    • Cozens, N.J.1    Murchison, J.T.2    Allan, P.L.3    Winney, R.J.4
  • 4
    • 0036729567 scopus 로고    scopus 로고
    • Using the automated biopsy gun with real-time ultrasound for native renal biopsy
    • Ori Y., Neuman H., Chagnac A., et al. Using the automated biopsy gun with real-time ultrasound for native renal biopsy. Isr Med Assoc J 4 (2002) 698-701
    • (2002) Isr Med Assoc J , vol.4 , pp. 698-701
    • Ori, Y.1    Neuman, H.2    Chagnac, A.3
  • 5
    • 33745962632 scopus 로고    scopus 로고
    • Application of a single needle type for all image-guided biopsies: results of 100 consecutive core biopsies in various organs using a novel tri-axial, end-cut needle
    • Diederich S., Padge B., Vossas U., Hake R., and Eidt S. Application of a single needle type for all image-guided biopsies: results of 100 consecutive core biopsies in various organs using a novel tri-axial, end-cut needle. Cancer Imaging 6 (2006) 43-50
    • (2006) Cancer Imaging , vol.6 , pp. 43-50
    • Diederich, S.1    Padge, B.2    Vossas, U.3    Hake, R.4    Eidt, S.5
  • 6
    • 0036062435 scopus 로고    scopus 로고
    • A new core-biopsy instrument with an end-cut technique provides prostate biopsies with increased tissue yield
    • Häggarth L., Ekman P., and Egevad L. A new core-biopsy instrument with an end-cut technique provides prostate biopsies with increased tissue yield. BJU Int 90 (2002) 51-55
    • (2002) BJU Int , vol.90 , pp. 51-55
    • Häggarth, L.1    Ekman, P.2    Egevad, L.3
  • 7
    • 0036159952 scopus 로고    scopus 로고
    • Improving glandular coverage during prostate biopsy using a long-core needle: technical performance of an end-cutting needle
    • Ubhayakar G.N., Li W.Y., Corbishley C.M., and Patel U. Improving glandular coverage during prostate biopsy using a long-core needle: technical performance of an end-cutting needle. BJU Int 89 (2002) 40-43
    • (2002) BJU Int , vol.89 , pp. 40-43
    • Ubhayakar, G.N.1    Li, W.Y.2    Corbishley, C.M.3    Patel, U.4
  • 8
    • 3242877827 scopus 로고    scopus 로고
    • Society of Interventional Radiology clinical practice guidelines
    • Sacks D., McClenny T., Cardella J., and Lewis C. Society of Interventional Radiology clinical practice guidelines. J Vasc Interv Radiol 14 (2003) S199-S202
    • (2003) J Vasc Interv Radiol , vol.14
    • Sacks, D.1    McClenny, T.2    Cardella, J.3    Lewis, C.4
  • 10
    • 0033918056 scopus 로고    scopus 로고
    • A prospective randomized trial of three different sizes of core-cutting needle for renal transplant biopsy
    • Nicholson M.L., Wheatley T.J., Doughman T.M., et al. A prospective randomized trial of three different sizes of core-cutting needle for renal transplant biopsy. Kidney Int 58 (2000) 390-395
    • (2000) Kidney Int , vol.58 , pp. 390-395
    • Nicholson, M.L.1    Wheatley, T.J.2    Doughman, T.M.3
  • 11
    • 0027462329 scopus 로고
    • Safety and efficacy of kidney transplant biopsy: Tru-cut needle vs sonographically guided Biopty needle
    • Mahoney M.C., Racadio J.M., Merhar G.L., and First M.R. Safety and efficacy of kidney transplant biopsy: Tru-cut needle vs sonographically guided Biopty needle. AJR Am J Roentgenol 160 (1993) 325-326
    • (1993) AJR Am J Roentgenol , vol.160 , pp. 325-326
    • Mahoney, M.C.1    Racadio, J.M.2    Merhar, G.L.3    First, M.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.