메뉴 건너뛰기




Volumn 91, Issue 7, 1996, Pages 1318-1321

Percutaneous biopsy in diffuse liver disease: Increasing diagnostic yield and decreasing complication rate by routine ultrasound assessment of puncture site

Author keywords

[No Author keywords available]

Indexed keywords

ATROPINE;

EID: 0030040072     PISSN: 00029270     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (105)

References (29)
  • 1
    • 0001109584 scopus 로고
    • Liver biopsy: Methods, diagnostic value, and interpretation
    • Millward-Sadler GH, Wright R, Arthur MJP, eds. London: WB Saunders
    • Millward-Sadler GH, Whorwell PJ. Liver biopsy: Methods, diagnostic value, and interpretation. In: Millward-Sadler GH, Wright R, Arthur MJP, eds. Wright's liver and biliary disease, 3rd ed. London: WB Saunders, 1992:476-97.
    • (1992) Wright's Liver and Biliary Disease, 3rd Ed. , pp. 476-497
    • Millward-Sadler, G.H.1    Whorwell, P.J.2
  • 2
    • 0021247430 scopus 로고
    • Liver biopsy: Techniques, clinical applications, and complications
    • Hegarty JE, Williams R. Liver biopsy: Techniques, clinical applications, and complications. Br Med J 1984;284:1254-6.
    • (1984) Br Med J , vol.284 , pp. 1254-1256
    • Hegarty, J.E.1    Williams, R.2
  • 3
    • 0022647490 scopus 로고
    • Complications following percutaneous liver biopsy. A multicentre retrospective study on 68,276 biopsies
    • Piccinino F, Sagnelli E, Pasquale G, et al. Complications following percutaneous liver biopsy. A multicentre retrospective study on 68,276 biopsies. J Hepatol 1986;2:165-73.
    • (1986) J Hepatol , vol.2 , pp. 165-173
    • Piccinino, F.1    Sagnelli, E.2    Pasquale, G.3
  • 4
    • 0023067189 scopus 로고
    • Prospective study of the incidence of ultrasound-detected intrahepatic and subcapsular hematomas in patients randomized to 6 or 24 hours of bed rest after percutaneous liver biopsy
    • Minuk GY, Sutherland LR, Wiseman DA, et al. Prospective study of the incidence of ultrasound-detected intrahepatic and subcapsular hematomas in patients randomized to 6 or 24 hours of bed rest after percutaneous liver biopsy. Gastroenterology 1987;92:290-3.
    • (1987) Gastroenterology , vol.92 , pp. 290-293
    • Minuk, G.Y.1    Sutherland, L.R.2    Wiseman, D.A.3
  • 5
    • 0024590932 scopus 로고
    • Liver biopsy complications monitored by ultrasound
    • Hederstrom E, Forsberg L, Florén CH, et al. Liver biopsy complications monitored by ultrasound. J Hepatol 1989;8:94-8.
    • (1989) J Hepatol , vol.8 , pp. 94-98
    • Hederstrom, E.1    Forsberg, L.2    Florén, C.H.3
  • 6
    • 0021934310 scopus 로고
    • Liver biopsy today: The Royal Free Hospital experience
    • Sherlock S, Dick R, Van Leeuwen DJ. Liver biopsy today: The Royal Free Hospital experience. J Hepatol 1984;1:75-85.
    • (1984) J Hepatol , vol.1 , pp. 75-85
    • Sherlock, S.1    Dick, R.2    Van Leeuwen, D.J.3
  • 7
    • 0023215579 scopus 로고
    • Failure of percutaneous liver biopsy: Anatomical variation
    • Dixon AK, Nunez DJ, Bradley JR, et al. Failure of percutaneous liver biopsy: Anatomical variation. Lancet 1987;2:437-9.
    • (1987) Lancet , vol.2 , pp. 437-439
    • Dixon, A.K.1    Nunez, D.J.2    Bradley, J.R.3
  • 8
    • 0023727165 scopus 로고
    • Ultrasound-assisted percutaneous liver biopsy: Superiority of the Tru-cut over the Menghini needle for diagnosis of cirrhosis
    • Colombo M, Del Ninno E, De Franchis R, et al. Ultrasound-assisted percutaneous liver biopsy: Superiority of the Tru-cut over the Menghini needle for diagnosis of cirrhosis. Gastroenterology 1988; 95:487-9.
    • (1988) Gastroenterology , vol.95 , pp. 487-489
    • Colombo, M.1    Del Ninno, E.2    De Franchis, R.3
  • 9
    • 0026006172 scopus 로고
    • A randomized trial of ultrasound-guided anterior subcostal liver biopsy versus the conventional Menghini technique
    • Papini E, Pacella CM, Rossi Z, et al. A randomized trial of ultrasound-guided anterior subcostal liver biopsy versus the conventional Menghini technique. J Hepatol 1991;13:291-7.
    • (1991) J Hepatol , vol.13 , pp. 291-297
    • Papini, E.1    Pacella, C.M.2    Rossi, Z.3
  • 10
    • 0020702627 scopus 로고
    • Percutaneous blind biopsy versus laparoscopy with guided biopsy in diagnosis of cirrhosis: A prospective randomized trial
    • Pagliaro L, Rinaldi F, Craxì A, et al. Percutaneous blind biopsy versus laparoscopy with guided biopsy in diagnosis of cirrhosis: A prospective randomized trial. Dig Dis Sci 1983;28:39-43.
    • (1983) Dig Dis Sci , vol.28 , pp. 39-43
    • Pagliaro, L.1    Rinaldi, F.2    Craxì, A.3
  • 11
    • 0016156945 scopus 로고
    • A comparison of accuracy of peritoneoscopy and liver biopsy in the diagnosis of cirrhosis
    • Bruguera M, Borda JM, Mass P, et al. A comparison of accuracy of peritoneoscopy and liver biopsy in the diagnosis of cirrhosis. Gut 1974;15:799-800.
    • (1974) Gut , vol.15 , pp. 799-800
    • Bruguera, M.1    Borda, J.M.2    Mass, P.3
  • 12
    • 0020000749 scopus 로고
    • Transvenous liver biopsy. An experience based on 1000 hepatic tissue samplings with this procedure
    • Lebrec D, Goldfard G, Degott C, et al. Transvenous liver biopsy. An experience based on 1000 hepatic tissue samplings with this procedure. Gastroenterology 1982;83:338-40.
    • (1982) Gastroenterology , vol.83 , pp. 338-340
    • Lebrec, D.1    Goldfard, G.2    Degott, C.3
  • 13
    • 0027473378 scopus 로고
    • A comparison of transjugular and plugged-percutaneous liver biopsy in patients with impaired coagulation
    • Sawyerr AM, McCormick PA, Tennyson GS, et al. A comparison of transjugular and plugged-percutaneous liver biopsy in patients with impaired coagulation. J Hepatol 1993;17:81-5.
    • (1993) J Hepatol , vol.17 , pp. 81-85
    • Sawyerr, A.M.1    McCormick, P.A.2    Tennyson, G.S.3
  • 14
    • 0025224860 scopus 로고
    • Ultrasound-guided fine-needle biopsy of focal liver lesions: Techniques, diagnostic accuracy and complications
    • Buscarini L, Fornari F, Bolondi L, et al. Ultrasound-guided fine-needle biopsy of focal liver lesions: Techniques, diagnostic accuracy and complications. J Hepatol 1990;11:344-8.
    • (1990) J Hepatol , vol.11 , pp. 344-348
    • Buscarini, L.1    Fornari, F.2    Bolondi, L.3
  • 15
    • 0025202217 scopus 로고
    • Role of ultrasound guided fine needle aspiration biopsy in the diagnosis of hepatocellular carcinoma
    • Sbolli G, Fornari F, Civardi G, et al. Role of ultrasound guided fine needle aspiration biopsy in the diagnosis of hepatocellular carcinoma. Gut 1990;31:1303-5.
    • (1990) Gut , vol.31 , pp. 1303-1305
    • Sbolli, G.1    Fornari, F.2    Civardi, G.3
  • 16
    • 0024311372 scopus 로고
    • Image-directed percutaneous biopsies with a biopsy gun
    • Parker SH, Hopper KD, Yakes WF, et al. Image-directed percutaneous biopsies with a biopsy gun. Radiology 1989;171:663-9.
    • (1989) Radiology , vol.171 , pp. 663-669
    • Parker, S.H.1    Hopper, K.D.2    Yakes, W.F.3
  • 17
    • 0024421838 scopus 로고
    • Guided percutaneous biopsy of intrabdominal lesions
    • Scott Gazelle G, Haaga JR. Guided percutaneous biopsy of intrabdominal lesions. AJR 1989;153:929-35.
    • (1989) AJR , vol.153 , pp. 929-935
    • Scott Gazelle, G.1    Haaga, J.R.2
  • 18
    • 0018880041 scopus 로고
    • Reproducibility of liver biopsy diagnosis in relation to the size of the specimen
    • Holund B, Poulsen H, Schlichting P. Reproducibility of liver biopsy diagnosis in relation to the size of the specimen. Scand J Gastroenterol 1980;15:329-35.
    • (1980) Scand J Gastroenterol , vol.15 , pp. 329-335
    • Holund, B.1    Poulsen, H.2    Schlichting, P.3
  • 19
    • 0017927812 scopus 로고
    • Liver biopsy: Complications in 1000 inpatients and outpatients
    • Perrault J, McGill DB, Ott BJ, et al. Liver biopsy: Complications in 1000 inpatients and outpatients. Gastroenterology 1978;74:103-6.
    • (1978) Gastroenterology , vol.74 , pp. 103-106
    • Perrault, J.1    McGill, D.B.2    Ott, B.J.3
  • 20
    • 0025119535 scopus 로고
    • A 21-year experience with major hemorrhage after percutaneous liver biopsy
    • McGill DB, Rakela J, Zinsmeister AR, et al. A 21-year experience with major hemorrhage after percutaneous liver biopsy. Gastroenterology 1990;99:1396-400.
    • (1990) Gastroenterology , vol.99 , pp. 1396-1400
    • McGill, D.B.1    Rakela, J.2    Zinsmeister, A.R.3
  • 21
    • 0027174954 scopus 로고
    • Liver biopsy: Its safety and complications as seen at a liver transplant center
    • Van Thiel DH, Gavaler JS, Wright H, et al. Liver biopsy: Its safety and complications as seen at a liver transplant center. Transplantation 1993;55:1087-90.
    • (1993) Transplantation , vol.55 , pp. 1087-1090
    • Van Thiel, D.H.1    Gavaler, J.S.2    Wright, H.3
  • 22
    • 0027043081 scopus 로고
    • Outcome of patients hospitalized for complications after outpatient liver biopsy
    • Janes CH, Lindor KD. Outcome of patients hospitalized for complications after outpatient liver biopsy. Ann Intern Med 1993;118:96-8.
    • (1993) Ann Intern Med , vol.118 , pp. 96-98
    • Janes, C.H.1    Lindor, K.D.2
  • 23
    • 0027219876 scopus 로고
    • Practice and complications of liver biopsy: Results of a nationwide survey in Switzerland
    • Froehlich F, Lamy O, Fried M, et al. Practice and complications of liver biopsy: Results of a nationwide survey in Switzerland. Dig Dis Sci 1993;38:1480-4.
    • (1993) Dig Dis Sci , vol.38 , pp. 1480-1484
    • Froehlich, F.1    Lamy, O.2    Fried, M.3
  • 24
    • 0028346872 scopus 로고
    • A nationwide survey of liver biopsy: Is there a need to increase resources, manpower and training?
    • Chuah SY, Moody GA, Wicks ACB, et al. A nationwide survey of liver biopsy: Is there a need to increase resources, manpower and training? Hepatogastroenterology 1994;41:4-8.
    • (1994) Hepatogastroenterology , vol.41 , pp. 4-8
    • Chuah, S.Y.1    Moody, G.A.2    Wicks, A.C.B.3
  • 25
    • 0028913123 scopus 로고
    • Indications, methods and outcomes of percutaneous liver biopsy in England and Wales: An audit by the British Society of Gastroenterology and Royal College of Physicians of London
    • Gilmore IT, Burroughs A, Murray-Lyon IM, et al. Indications, methods and outcomes of percutaneous liver biopsy in England and Wales: An audit by the British Society of Gastroenterology and Royal College of Physicians of London. Gut 1995;36:437-41.
    • (1995) Gut , vol.36 , pp. 437-441
    • Gilmore, I.T.1    Burroughs, A.2    Murray-Lyon, I.M.3
  • 26
    • 0017920413 scopus 로고
    • Percutaneous biopsy of the liver as a procedure for outpatients
    • Knauer CM. Percutaneous biopsy of the liver as a procedure for outpatients. Gastroenterology 1978;74:101-2.
    • (1978) Gastroenterology , vol.74 , pp. 101-102
    • Knauer, C.M.1
  • 27
    • 0019959543 scopus 로고
    • The risk of bleeding after percutaneous liver biopsy: Relation to the platelet count
    • Sharma P, McDonald GB, Banaji M. The risk of bleeding after percutaneous liver biopsy: Relation to the platelet count. J Clin Gastroenterol 1982;4:451-3.
    • (1982) J Clin Gastroenterol , vol.4 , pp. 451-453
    • Sharma, P.1    McDonald, G.B.2    Banaji, M.3
  • 28
    • 0026690349 scopus 로고
    • Effect of needle gauge, level of anticoagulation, and target organ on bleeding associated with aspiration biopsy
    • Scott Gazelle G, Haaga JR, Rowland DY. Effect of needle gauge, level of anticoagulation, and target organ on bleeding associated with aspiration biopsy. Radiology 1992;183:509-13.
    • (1992) Radiology , vol.183 , pp. 509-513
    • Scott Gazelle, G.1    Haaga, J.R.2    Rowland, D.Y.3
  • 29
    • 0027482873 scopus 로고
    • Fine-needle liver biopsy in patients with severely impaired coagulation
    • Caturelli E, Squillante MM, Andriulli A, et al. Fine-needle liver biopsy in patients with severely impaired coagulation. Liver 1993;13:270-3.
    • (1993) Liver , vol.13 , pp. 270-273
    • Caturelli, E.1    Squillante, M.M.2    Andriulli, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.